-
1
-
-
0023072056
-
Theoretical limits to sensitivity and resolution in impedance imaging
-
Seagar A.D., Barber D.C., and Brown B.H. Theoretical limits to sensitivity and resolution in impedance imaging. Clin Phys Physiol Meas 8 4A (1987) 13-31
-
(1987)
Clin Phys Physiol Meas
, vol.8
, Issue.4 A
, pp. 13-31
-
-
Seagar, A.D.1
Barber, D.C.2
Brown, B.H.3
-
2
-
-
0026221249
-
Measurement of nonuniform current density by magnetic resonance
-
Scott G.C., Joy M.L.G., Armstrong R.L., and Henkelman R.M. Measurement of nonuniform current density by magnetic resonance. IEEE Trans Med Imaging 10 3 (1991) 362-374
-
(1991)
IEEE Trans Med Imaging
, vol.10
, Issue.3
, pp. 362-374
-
-
Scott, G.C.1
Joy, M.L.G.2
Armstrong, R.L.3
Henkelman, R.M.4
-
3
-
-
0027081242
-
RF current density imaging in homogeneous media
-
Scott G.C., Joy M.L.G., Armstrong R.L., and Henkelman R.M. RF current density imaging in homogeneous media. Magn Reson Med 28 2 (1992) 186-201
-
(1992)
Magn Reson Med
, vol.28
, Issue.2
, pp. 186-201
-
-
Scott, G.C.1
Joy, M.L.G.2
Armstrong, R.L.3
Henkelman, R.M.4
-
4
-
-
0031240183
-
Measurement of AC magnetic field distribution using magnetic resonance imaging
-
Ider Y.Z., and Muftuler L.T. Measurement of AC magnetic field distribution using magnetic resonance imaging. IEEE Trans Med Imaging 16 5 (1997) 617-622
-
(1997)
IEEE Trans Med Imaging
, vol.16
, Issue.5
, pp. 617-622
-
-
Ider, Y.Z.1
Muftuler, L.T.2
-
5
-
-
0034848888
-
Magnetic resonance imaging of alternating electric currents
-
Mikac U., Demsar F., Beravs K., and Sersa I. Magnetic resonance imaging of alternating electric currents. Magn Reson Imaging 19 6 (2001) 845-856
-
(2001)
Magn Reson Imaging
, vol.19
, Issue.6
, pp. 845-856
-
-
Mikac, U.1
Demsar, F.2
Beravs, K.3
Sersa, I.4
-
6
-
-
0021392612
-
Magnetic field measurement by NMR imaging
-
Maudsley A.A., Simon H.E., and Hilal S.K. Magnetic field measurement by NMR imaging. J Phys [E] 17 3 (1984) 216-220
-
(1984)
J Phys [E]
, vol.17
, Issue.3
, pp. 216-220
-
-
Maudsley, A.A.1
Simon, H.E.2
Hilal, S.K.3
-
7
-
-
0000178261
-
Sensitivity of magnetic-resonance current-density imaging
-
Scott G.C., Joy M.L.G., Armstrong R.L., and Henkelman R.M. Sensitivity of magnetic-resonance current-density imaging. J Magn Reson 97 2 (1992) 235-254
-
(1992)
J Magn Reson
, vol.97
, Issue.2
, pp. 235-254
-
-
Scott, G.C.1
Joy, M.L.G.2
Armstrong, R.L.3
Henkelman, R.M.4
-
8
-
-
0030802130
-
Ghost artifact reduction for echo planar imaging using image phase correction
-
Buonocore M.H., and Gao L. Ghost artifact reduction for echo planar imaging using image phase correction. Magn Reson Med 38 1 (1997) 89-100
-
(1997)
Magn Reson Med
, vol.38
, Issue.1
, pp. 89-100
-
-
Buonocore, M.H.1
Gao, L.2
-
9
-
-
0038398642
-
A simple simultaneous geometric and intensity correction method for echo-planar imaging by EPI-based phase modulation
-
Chiou J.Y., Ahn C.B., Muftuler L.T., and Nalcioglu O. A simple simultaneous geometric and intensity correction method for echo-planar imaging by EPI-based phase modulation. IEEE Trans Med Imaging 22 2 (2003) 200-205
-
(2003)
IEEE Trans Med Imaging
, vol.22
, Issue.2
, pp. 200-205
-
-
Chiou, J.Y.1
Ahn, C.B.2
Muftuler, L.T.3
Nalcioglu, O.4
-
10
-
-
0000872921
-
Use of the magnetic field generated by the internal distribution of injected currents for electrical impedance tomography (MR-EIT)
-
Ider Y.Z., and Birgul O. Use of the magnetic field generated by the internal distribution of injected currents for electrical impedance tomography (MR-EIT). Elektrik 6 (1998) 215-225
-
(1998)
Elektrik
, vol.6
, pp. 215-225
-
-
Ider, Y.Z.1
Birgul, O.2
-
11
-
-
0345308508
-
Experimental results for 2D magnetic resonance electrical impedance tomography (MR-EIT) using magnetic flux density in one direction
-
Birgul O., Eyuboglu B.M., and Ider Y.Z. Experimental results for 2D magnetic resonance electrical impedance tomography (MR-EIT) using magnetic flux density in one direction. Phys Med Biol 48 21 (2003) 3485-3504
-
(2003)
Phys Med Biol
, vol.48
, Issue.21
, pp. 3485-3504
-
-
Birgul, O.1
Eyuboglu, B.M.2
Ider, Y.Z.3
-
12
-
-
0038644775
-
Reconstruction of conductivity and current density images using only one component of magnetic field measurements
-
Seo J.K., Yoon J.R., Woo E.J., and Kwon O. Reconstruction of conductivity and current density images using only one component of magnetic field measurements. IEEE Trans Biomed Eng 50 9 (2003) 1121-1124
-
(2003)
IEEE Trans Biomed Eng
, vol.50
, Issue.9
, pp. 1121-1124
-
-
Seo, J.K.1
Yoon, J.R.2
Woo, E.J.3
Kwon, O.4
-
13
-
-
1342311383
-
Algebraic reconstruction for 3D magnetic resonance-electrical impedance tomography (MREIT) using one component of magnetic flux density
-
Ider Y.Z., and Onart S. Algebraic reconstruction for 3D magnetic resonance-electrical impedance tomography (MREIT) using one component of magnetic flux density. Physiol Meas 25 1 (2004) 281-294
-
(2004)
Physiol Meas
, vol.25
, Issue.1
, pp. 281-294
-
-
Ider, Y.Z.1
Onart, S.2
-
14
-
-
1642362448
-
Electrical conductivity imaging using gradient BZ decomposition algorithm in magnetic resonance electrical impedance tomography (MREIT)
-
Park C., Kwon O., Woo E.J., and Seo J.K. Electrical conductivity imaging using gradient BZ decomposition algorithm in magnetic resonance electrical impedance tomography (MREIT). IEEE Trans Med Imaging 23 3 (2004) 388-394
-
(2004)
IEEE Trans Med Imaging
, vol.23
, Issue.3
, pp. 388-394
-
-
Park, C.1
Kwon, O.2
Woo, E.J.3
Seo, J.K.4
-
15
-
-
1342311392
-
Static conductivity imaging using variational gradient BZ algorithm in magnetic resonance electrical impedance tomography
-
Park C., Park E.J., Woo E.J., Kwon O., and Seo J.K. Static conductivity imaging using variational gradient BZ algorithm in magnetic resonance electrical impedance tomography. Physiol Meas 25 1 (2004) 257-269
-
(2004)
Physiol Meas
, vol.25
, Issue.1
, pp. 257-269
-
-
Park, C.1
Park, E.J.2
Woo, E.J.3
Kwon, O.4
Seo, J.K.5
-
17
-
-
11144291548
-
Resolution and contrast in magnetic resonance electrical impedance tomography (MREIT) and its application to cancer imaging
-
Muftuler L.T., Hamamura M., Birgul O., and Nalcioglu O. Resolution and contrast in magnetic resonance electrical impedance tomography (MREIT) and its application to cancer imaging. Technol Cancer Res Treat 3 6 (2004) 599-609
-
(2004)
Technol Cancer Res Treat
, vol.3
, Issue.6
, pp. 599-609
-
-
Muftuler, L.T.1
Hamamura, M.2
Birgul, O.3
Nalcioglu, O.4
-
18
-
-
33744824075
-
Measurement of ion diffusion using magnetic resonance electrical impedance tomography
-
Hamamura M.J., Muftuler L.T., Birgul O., and Nalcioglu O. Measurement of ion diffusion using magnetic resonance electrical impedance tomography. Phys Med Bio 51 11 (2006) 2753-2762
-
(2006)
Phys Med Bio
, vol.51
, Issue.11
, pp. 2753-2762
-
-
Hamamura, M.J.1
Muftuler, L.T.2
Birgul, O.3
Nalcioglu, O.4
-
19
-
-
33748036068
-
In vivo MRI electrical impedance tomography (MREIT) of tumors
-
Muftuler L.T., Hamamura M.J., Birgul O., and Nalcioglu O. In vivo MRI electrical impedance tomography (MREIT) of tumors. Technol Cancer Res Treat 5 4 (2006) 381-387
-
(2006)
Technol Cancer Res Treat
, vol.5
, Issue.4
, pp. 381-387
-
-
Muftuler, L.T.1
Hamamura, M.J.2
Birgul, O.3
Nalcioglu, O.4
-
20
-
-
33748932489
-
Contrast and spatial resolution in MREIT using low amplitude current
-
Birgul O., Hamamura M.J., Muftuler L.T., and Nalcioglu O. Contrast and spatial resolution in MREIT using low amplitude current. Phys Med Biol 51 19 (2006) 5035-5049
-
(2006)
Phys Med Biol
, vol.51
, Issue.19
, pp. 5035-5049
-
-
Birgul, O.1
Hamamura, M.J.2
Muftuler, L.T.3
Nalcioglu, O.4
-
22
-
-
0031106685
-
The electrical conductivity of human cerebrospinal fluid at body temperature
-
Baumann S.B., Wozny D.R., Kelly S.K., and Meno F.M. The electrical conductivity of human cerebrospinal fluid at body temperature. IEEE Trans Biomed Eng 44 3 (1997) 220-223
-
(1997)
IEEE Trans Biomed Eng
, vol.44
, Issue.3
, pp. 220-223
-
-
Baumann, S.B.1
Wozny, D.R.2
Kelly, S.K.3
Meno, F.M.4
-
23
-
-
0036157954
-
Magnetic resonance electrical impedance tomography (MREIT): simulation study of J-substitution algorithm
-
Kwon O., Woo E.J., Yoon J.R., and Seo J.K. Magnetic resonance electrical impedance tomography (MREIT): simulation study of J-substitution algorithm. IEEE Trans Biomed Eng 49 2 (2002) 160-167
-
(2002)
IEEE Trans Biomed Eng
, vol.49
, Issue.2
, pp. 160-167
-
-
Kwon, O.1
Woo, E.J.2
Yoon, J.R.3
Seo, J.K.4
-
24
-
-
23044508481
-
Electrical conductivity images of biological tissue phantoms in MREIT
-
Oh S.H., Lee B.I., Woo E.J., Lee S.Y., Kim T.-S., Kwon O., et al. Electrical conductivity images of biological tissue phantoms in MREIT. Phys Meas 26 2 (2005) S279-S288
-
(2005)
Phys Meas
, vol.26
, Issue.2
-
-
Oh, S.H.1
Lee, B.I.2
Woo, E.J.3
Lee, S.Y.4
Kim, T.-S.5
Kwon, O.6
-
25
-
-
0021187361
-
Limits to signal-to-noise improvement by FID averaging in NMR imaging
-
Nalcioglu O., and Cho Z.H. Limits to signal-to-noise improvement by FID averaging in NMR imaging. Phys Med Biol 29 8 (1984) 969-978
-
(1984)
Phys Med Biol
, vol.29
, Issue.8
, pp. 969-978
-
-
Nalcioglu, O.1
Cho, Z.H.2
|