메뉴 건너뛰기




Volumn 43, Issue 4, 2008, Pages 358-388

Thermal lens spectrometric detection in flow injection analysis and separation techniques

Author keywords

Capillary electrophoresis; Flow injection analysis; Liquid chromatography; Thermal lens spectrometry

Indexed keywords

CAPILLARY ELECTROPHORESIS; CERIUM; CHEMICALS; CHROMATOGRAPHIC ANALYSIS; CHROMATOGRAPHY; ELECTROPHORESIS; HIGH PERFORMANCE LIQUID CHROMATOGRAPHY; HIGH PRESSURE LIQUID CHROMATOGRAPHY; INTEGRATED CIRCUITS; LENSES; LIQUID CHROMATOGRAPHY; OPTICAL INSTRUMENTS; SENSITIVITY ANALYSIS; SEPARATION; SPECTROMETRY; SURVEYING INSTRUMENTS;

EID: 45849103089     PISSN: 05704928     EISSN: 1520569X     Source Type: Journal    
DOI: 10.1080/05704920802108032     Document Type: Article
Times cited : (50)

References (128)
  • 1
    • 0003274509 scopus 로고    scopus 로고
    • Photothermal spectroscopy methods for chemical analysis
    • John Wiley & Sons, New York
    • Bialkowski, S. E. (1996) Photothermal spectroscopy methods for chemical analysis. Chemical Analysis, 134, John Wiley & Sons, New York
    • (1996) Chemical Analysis , vol.134
    • Bialkowski, S.E.1
  • 2
    • 0013481402 scopus 로고    scopus 로고
    • Analytical thermal lens instrumentation
    • Franko, M. and Tran, C. D. (1996) Analytical thermal lens instrumentation. Rev. Sci. Instrum., 67, pp. 1-18.
    • (1996) Rev. Sci. Instrum. , vol.67 , pp. 1-18
    • Franko, M.1    Tran, C.D.2
  • 3
    • 33845278779 scopus 로고
    • Development of a double-beam, dual-wavelength thermal-lens spectrometer for simultaneous measurement of absorption at two different wavelengths
    • Franko, M. and Tran, C. D. (1988) Development of a double-beam, dual-wavelength thermal-lens spectrometer for simultaneous measurement of absorption at two different wavelengths. Anal. Chem., 60, pp. 1925-1928.
    • (1988) Anal. Chem. , vol.60 , pp. 1925-1928
    • Franko, M.1    Tran, C.D.2
  • 4
    • 0024714997 scopus 로고
    • Dual-wavelength photothermal refraction spectrometry for small-volume samples
    • Tran, C. D. and Xu, M. (1989) Dual-wavelength photothermal refraction spectrometry for small-volume samples. Appl. Spectros., 43, pp. 1056-1061.
    • (1989) Appl. Spectros. , vol.43 , pp. 1056-1061
    • Tran, C.D.1    Xu, M.2
  • 5
    • 0025708770 scopus 로고
    • Thermal lens-circular dichroism detector for high-performance liquid chromatography
    • Xu, M. and Tran, C. D. (1990) Thermal lens-circular dichroism detector for high-performance liquid chromatography. Anal. Chem., 62, pp. 2467-2471.
    • (1990) Anal. Chem. , vol.62 , pp. 2467-2471
    • Xu, M.1    Tran, C.D.2
  • 6
    • 0025166924 scopus 로고
    • Multi-wavelength thermal lens spectrophotometer
    • Xu, M. and Tran, C. D. (1990) Multi-wavelength thermal lens spectrophotometer. Anal. Chim. Acta, 235, pp. 445-449.
    • (1990) Anal. Chim. Acta , vol.235 , pp. 445-449
    • Xu, M.1    Tran, C.D.2
  • 7
    • 0026886754 scopus 로고
    • Multiwavelength thermal lens spectrophotometer based on an acousto-optic tunable filter
    • Tran, C. D. and Simianu, V. (1992) Multiwavelength thermal lens spectrophotometer based on an acousto-optic tunable filter. Anal. Chem., 64, pp. 1419-1425.
    • (1992) Anal. Chem. , vol.64 , pp. 1419-1425
    • Tran, C.D.1    Simianu, V.2
  • 8
    • 0001673680 scopus 로고
    • Development of a multiwavelength thermal lens spectrophotometer based on an acousto-optic tuneable filter as a polychromator
    • Tran, C. D., Furlan, R. J. and Lu, J. (1994) Development of a multiwavelength thermal lens spectrophotometer based on an acousto-optic tuneable filter as a polychromator. Appl. Spectros., 48, pp. 101-106.
    • (1994) Appl. Spectros. , vol.48 , pp. 101-106
    • Tran, C.D.1    Furlan, R.J.2    Lu, J.3
  • 9
    • 17544405213 scopus 로고
    • Double beam thermal lens spectrometry for actinides detection and speciation
    • Moulin, C., Delorme, N., Berthoud, T. and Mouchien, P. (1988) Double beam thermal lens spectrometry for actinides detection and speciation. Radiochim. Acta, 4445, pp. 103-106.
    • (1988) Radiochim. Acta , vol.4445 , pp. 103-106
    • Moulin, C.1    Delorme, N.2    Berthoud, T.3    Mouchien, P.4
  • 10
    • 0005834415 scopus 로고
    • Thermal lensing spectrophotometry of uranium (VI) with pulsed laser excitation
    • Omenetto, N., Cavalli, P., Rossi, G., Bidoglio, G. and Turk, G. C. (1987) Thermal lensing spectrophotometry of uranium (VI) with pulsed laser excitation. J. Anal. Atom. Spectrom., 2, pp. 579-583.
    • (1987) J. Anal. Atom. Spectrom. , vol.2 , pp. 579-583
    • Omenetto, N.1    Cavalli, P.2    Rossi, G.3    Bidoglio, G.4    Turk, G.C.5
  • 11
    • 0001023926 scopus 로고    scopus 로고
    • Thermal lens spectrometry in food analysis and environmental research
    • Franko, M., Sikovec, M., Kozar-Logar, J. and Bicanic, D. (2001) Thermal lens spectrometry in food analysis and environmental research. Anal. Sci., 17, pp. S515-S518.
    • (2001) Anal. Sci. , vol.17
    • Franko, M.1    Sikovec, M.2    Kozar-Logar, J.3    Bicanic, D.4
  • 13
    • 0005829295 scopus 로고
    • Real-time thermal lens absorption measurements with application to flow-injection systems
    • Leach, R. A. and Harris, J. M. (1984) Real-time thermal lens absorption measurements with application to flow-injection systems. Anal. Chim. Acta, 164, pp. 91-101.
    • (1984) Anal. Chim. Acta , vol.164 , pp. 91-101
    • Leach, R.A.1    Harris, J.M.2
  • 14
    • 0020125567 scopus 로고
    • Laser induced thermal lens effect: A new theoretical model
    • Sheldon, S. J., Knight, L. V. and Thorne, J. M. (1982) Laser induced thermal lens effect: A new theoretical model. Appl. Optic., 21, pp. 1663-1669.
    • (1982) Appl. Optic. , vol.21 , pp. 1663-1669
    • Sheldon, S.J.1    Knight, L.V.2    Thorne, J.M.3
  • 15
    • 0017995629 scopus 로고
    • Analysis of the repetitively pulsed dual-beam thermo-optical absorption spectrometer
    • Swofford, R. L. and Morell, J. A. (1978) Analysis of the repetitively pulsed dual-beam thermo-optical absorption spectrometer. J. Appl. Phys., 49, pp. 3667-3674.
    • (1978) J. Appl. Phys. , vol.49 , pp. 3667-3674
    • Swofford, R.L.1    Morell, J.A.2
  • 16
    • 0021476541 scopus 로고
    • Theory of laser-induced photothermal refraction
    • Dovichi, N. J., Nolan, T. G. and Weimer, W. A. (1984) Theory of laser-induced photothermal refraction. Anal. Chem., 56, pp. 1700-1704.
    • (1984) Anal. Chem. , vol.56 , pp. 1700-1704
    • Dovichi, N.J.1    Nolan, T.G.2    Weimer, W.A.3
  • 17
    • 0000903695 scopus 로고
    • Photothermal lensing spectroscopy in a flowing medium: Theory
    • Vyas, R. and Gupta, R. (1988) Photothermal lensing spectroscopy in a flowing medium: Theory. Appl. Optic., 27, pp. 4701-4711.
    • (1988) Appl. Optic. , vol.27 , pp. 4701-4711
    • Vyas, R.1    Gupta, R.2
  • 18
    • 0019550076 scopus 로고
    • Thermal lens calorimetry for flowing samples
    • Dovichi, N. J. and Harris, J. M. (1981) Thermal lens calorimetry for flowing samples. Anal. Chem., 53, pp. 689-692.
    • (1981) Anal. Chem. , vol.53 , pp. 689-692
    • Dovichi, N.J.1    Harris, J.M.2
  • 19
    • 0022162549 scopus 로고
    • Time-resolved thermal lens measurements in flowing samples
    • Weimer, W. A. and Dovichi, N. J. (1985) Time-resolved thermal lens measurements in flowing samples. Anal.Chem., 57, pp. 2436-2441.
    • (1985) Anal.Chem. , vol.57 , pp. 2436-2441
    • Weimer, W.A.1    Dovichi, N.J.2
  • 20
    • 24944507579 scopus 로고    scopus 로고
    • Signal optimization in CW-laser crossed-beam photothermal spectrometry: Influence of the chopping frequency, sample size and flow rate
    • Ghaleb, K. A. and Gerges, J. (2005) Signal optimization in CW-laser crossed-beam photothermal spectrometry: Influence of the chopping frequency, sample size and flow rate. Spectrochim. Acta A, 61, pp. 2849-2855.
    • (2005) Spectrochim. Acta A , vol.61 , pp. 2849-2855
    • Ghaleb, K.A.1    Gerges, J.2
  • 21
    • 30344437249 scopus 로고    scopus 로고
    • Optimization of instrumental parameters of a near-field thermal lens detector for capillary electrophoresis
    • Proskurnin, M. A., Bendrysheva, S. N., Ragozina, N., Heissler, S., Faubel, W. and Pyell, U. (2005) Optimization of instrumental parameters of a near-field thermal lens detector for capillary electrophoresis. Appl. Spectros., 59, pp. 1470-1479.
    • (2005) Appl. Spectros. , vol.59 , pp. 1470-1479
    • Proskurnin, M.A.1    Bendrysheva, S.N.2    Ragozina, N.3    Heissler, S.4    Faubel, W.5    Pyell, U.6
  • 22
    • 0022557917 scopus 로고
    • Pulsed laser thermal lens spectrophotometry for flowing liquid detection
    • Nickolaisen, S. L. and Bialkowski, S. E. (1986) Pulsed laser thermal lens spectrophotometry for flowing liquid detection. Anal. Chem., 58, pp. 215-220.
    • (1986) Anal. Chem. , vol.58 , pp. 215-220
    • Nickolaisen, S.L.1    Bialkowski, S.E.2
  • 23
    • 0036016936 scopus 로고    scopus 로고
    • Pulsed-laser mode-mismatched crossed-beam thermal lens spectrometry within a small capillary tube: Effect of flow rate and beam offset on the photothermal signal
    • Chanlon, S. and Georges, J. (2002) Pulsed-laser mode-mismatched crossed-beam thermal lens spectrometry within a small capillary tube: Effect of flow rate and beam offset on the photothermal signal. Spectrochim. Acta A, 58, pp. 1607-1613.
    • (2002) Spectrochim. Acta A , vol.58 , pp. 1607-1613
    • Chanlon, S.1    Georges, J.2
  • 24
    • 1242287090 scopus 로고    scopus 로고
    • Investigation of the optimum optical design for pulsed-laser crossed-beam thermal lens spectrometry in infinite and finite samples
    • Ghaleb, K. A. and Gerges, J. (2004) Investigation of the optimum optical design for pulsed-laser crossed-beam thermal lens spectrometry in infinite and finite samples. Spectrochim. Acta A, 60, pp. 863-872.
    • (2004) Spectrochim. Acta A , vol.60 , pp. 863-872
    • Ghaleb, K.A.1    Gerges, J.2
  • 25
    • 0022161282 scopus 로고
    • Optimization of photothermal refraction for flowing liquid samples
    • Weimer, W. A. and Dovichi, N. J. (1985) Optimization of photothermal refraction for flowing liquid samples. Appl. Spectros., 39, pp. 1009-1013.
    • (1985) Appl. Spectros. , vol.39 , pp. 1009-1013
    • Weimer, W.A.1    Dovichi, N.J.2
  • 26
    • 0035970920 scopus 로고    scopus 로고
    • Recent applications of thermal lens spectrometry in food analysis and environmental research
    • Franko, M. (2001) Recent applications of thermal lens spectrometry in food analysis and environmental research. Talanta, 54, pp. 1-13.
    • (2001) Talanta , vol.54 , pp. 1-13
    • Franko, M.1
  • 27
    • 0037144179 scopus 로고    scopus 로고
    • Laser-based non-fluorescence detection techniques for liquid separation systems
    • de Beer, T., Velthorst, N. H., Brinkman, U. A.Th. and Gooijer, C. (2002) Laser-based non-fluorescence detection techniques for liquid separation systems. J. Chrom. A, 971, pp. 1-35.
    • (2002) J. Chrom. A , vol.971 , pp. 1-35
    • de Beer, T.1    Velthorst, N.H.2    Brinkman, U.A.Th.3    Gooijer, C.4
  • 28
    • 0030578870 scopus 로고    scopus 로고
    • Thermal lens spectrometric determination of hexavalent chromium
    • Sikovec, M., Franko, M., Cruz, F. G. and Katz, S. A. (1996) Thermal lens spectrometric determination of hexavalent chromium. Anal. Chim. Acta, 330, pp. 245-250.
    • (1996) Anal. Chim. Acta , vol.330 , pp. 245-250
    • Sikovec, M.1    Franko, M.2    Cruz, F.G.3    Katz, S.A.4
  • 29
    • 0031751178 scopus 로고    scopus 로고
    • Determination of trans-β-carotene and other carotenoids in blood plasma using high-preformance liquid chromatography and thermal lens detection
    • Franko, M., Van De Bovenkamp, P. and Bicanic, D. (1998) Determination of trans-β-carotene and other carotenoids in blood plasma using high-preformance liquid chromatography and thermal lens detection. J. Chrom. B Biomed. Sci. Appl., 718, pp. 47-54.
    • (1998) J. Chrom. B Biomed. Sci. Appl. , vol.718 , pp. 47-54
    • Franko, M.1    Van De Bovenkamp, P.2    Bicanic, D.3
  • 30
    • 0037802167 scopus 로고    scopus 로고
    • Determination of hexavalent chromium in drinking water by thermal lens spectrometry
    • Sikovec, M., Novic, Mi. and Franko, M. (2000) Determination of hexavalent chromium in drinking water by thermal lens spectrometry. Ann. Chim., 90, pp. 163-168.
    • (2000) Ann. Chim. , vol.90 , pp. 163-168
    • Sikovec, M.1    Novic, Mi.2    Franko, M.3
  • 31
    • 0034597362 scopus 로고    scopus 로고
    • Ultrasensitive determination of trans-β-carotene in rat and beef livers by means of high-performance liquid chromatography coupled with thermal lens detection
    • Luterotti, S., Sikovec, M. and Bicanic, D. (2000) Ultrasensitive determination of trans-β-carotene in rat and beef livers by means of high-performance liquid chromatography coupled with thermal lens detection. Talanta, 53, pp. 103-113.
    • (2000) Talanta , vol.53 , pp. 103-113
    • Luterotti, S.1    Sikovec, M.2    Bicanic, D.3
  • 32
    • 0032694409 scopus 로고    scopus 로고
    • Ultrasensitive determination of β-carotene in fish oil-based supplementary drugs by HPLC-TLS
    • Luterotti, S., Franko, M. and Bicanic, D. (1999) Ultrasensitive determination of β-carotene in fish oil-based supplementary drugs by HPLC-TLS. J. Pharm. Biomed. Anal., 21, pp. 901-909.
    • (1999) J. Pharm. Biomed. Anal. , vol.21 , pp. 901-909
    • Luterotti, S.1    Franko, M.2    Bicanic, D.3
  • 33
    • 0037024239 scopus 로고    scopus 로고
    • Ultrasensitive assays of trans- and cis-β-carotenes in vegetable oils by high-performance liquid chromatography-thermal lens detection
    • Luterotti, S., Franko, M., Sikovec, M. and Bicanic, D. (2002) Ultrasensitive assays of trans- and cis-β-carotenes in vegetable oils by high-performance liquid chromatography-thermal lens detection. Anal. Chim. Acta, 460, pp. 193-200.
    • (2002) Anal. Chim. Acta , vol.460 , pp. 193-200
    • Luterotti, S.1    Franko, M.2    Sikovec, M.3    Bicanic, D.4
  • 34
    • 0036806478 scopus 로고    scopus 로고
    • Fast quality screening of vegetable oils by HPLC-thermal lens spectrometric detection
    • Luterotti, S., Franko, M. and Bicanic, D. (2002) Fast quality screening of vegetable oils by HPLC-thermal lens spectrometric detection. J. Am. Oil Chem. Soc., 79, pp. 1027-1031.
    • (2002) J. Am. Oil Chem. Soc. , vol.79 , pp. 1027-1031
    • Luterotti, S.1    Franko, M.2    Bicanic, D.3
  • 35
    • 0026544374 scopus 로고
    • Optimization of an isocratic high-performance liquid chromatographic separation of carotenoids
    • Craft, N. E., Wise, S. A. and Soares Jr., J. H. (1992) Optimization of an isocratic high-performance liquid chromatographic separation of carotenoids. J. Chrom., 589, pp. 171-176.
    • (1992) J. Chrom. , vol.589 , pp. 171-176
    • Craft, N.E.1    Wise, S.A.2    Soares Jr., J.H.3
  • 36
    • 0025800021 scopus 로고
    • Determination of several retinoids, carotenoids and E vitamers by high-performance liquid chromatography: Application to plasma and tissues of rats fed a diet rich in either β-carotene or canthaxanthin
    • Van Fliet, T., van Schaak, F., van Schoonhoven, J. and Schrijver, J. (1991) Determination of several retinoids, carotenoids and E vitamers by high-performance liquid chromatography: Application to plasma and tissues of rats fed a diet rich in either β-carotene or canthaxanthin. J. Chrom., 553, pp. 179-186.
    • (1991) J. Chrom. , vol.553 , pp. 179-186
    • Van Fliet, T.1    van Schaak, F.2    van Schoonhoven, J.3    Schrijver, J.4
  • 40
    • 4243800344 scopus 로고    scopus 로고
    • Assessing the extent of oxidation in thermally stressed vegetable oils. Part I: Optical characterization by photothermal and some conventional physical methods
    • Bicanic, D., Doka, O., Luterotti, S., Bohren, A., Sikovec, M., van Veldhuizen, B., Berkessy, O., Chirtoc, M., Franko, M., Szabo, G. and Sigrist, M. (2001) Assessing the extent of oxidation in thermally stressed vegetable oils. Part I: Optical characterization by photothermal and some conventional physical methods. Anal. Sci., 17, pp. S547-S550.
    • (2001) Anal. Sci. , vol.17
    • Bicanic, D.1    Doka, O.2    Luterotti, S.3    Bohren, A.4    Sikovec, M.5    van Veldhuizen, B.6    Berkessy, O.7    Chirtoc, M.8    Franko, M.9    Szabo, G.10    Sigrist, M.11
  • 41
    • 31444443919 scopus 로고    scopus 로고
    • Double dual beam thermal lens spectrometer for monitoring of phytoplankton cell lysis
    • Kozar-Logar, J., Malej, A. and Franko, M. (2006) Double dual beam thermal lens spectrometer for monitoring of phytoplankton cell lysis. Instrum. Sci. Tech., 34, pp. 23-31.
    • (2006) Instrum. Sci. Tech. , vol.34 , pp. 23-31
    • Kozar-Logar, J.1    Malej, A.2    Franko, M.3
  • 43
    • 24444466986 scopus 로고    scopus 로고
    • Development of Laser Spectroscopic Techniques for Characterization and Studies of Phytoplankton Pigments
    • Nova Gorica Polytechnic
    • Kozar Logar, J. (2003) Development of Laser Spectroscopic Techniques for Characterization and Studies of Phytoplankton Pigments, Nova Gorica Polytechnic
    • (2003)
    • Kozar Logar, J.1
  • 44
    • 0037283349 scopus 로고    scopus 로고
    • Hyphenated high performance liquid chromatography-thermal lens spectrometry technique as a tool for investigations of xanthophyll cycle pigments in different taxonomic groups of marine phytoplankton
    • Kozar Logar, J., Malej, A. and Franko, M. (2003) Hyphenated high performance liquid chromatography-thermal lens spectrometry technique as a tool for investigations of xanthophyll cycle pigments in different taxonomic groups of marine phytoplankton. Rev. Sci. Instrum., 74, pp. 776-778.
    • (2003) Rev. Sci. Instrum. , vol.74 , pp. 776-778
    • Kozar Logar, J.1    Malej, A.2    Franko, M.3
  • 45
    • 0036387397 scopus 로고    scopus 로고
    • The effects of eluent mixing on TLS detection in gradient elution HPLC
    • Kozar Logar, J., Sikovec, M., Malej, A. and Franko, M. (2002) The effects of eluent mixing on TLS detection in gradient elution HPLC. Anal. Bioanal. Chem., 374, pp. 323-328.
    • (2002) Anal. Bioanal. Chem. , vol.374 , pp. 323-328
    • Kozar Logar, J.1    Sikovec, M.2    Malej, A.3    Franko, M.4
  • 46
    • 0037286148 scopus 로고    scopus 로고
    • The effects of eluent's optothermal parameters on TLS detection in gradient HPLC
    • Kozar Logar, J. and Franko, M. (2003) The effects of eluent's optothermal parameters on TLS detection in gradient HPLC. Rev. Sci. Instrum., 74, pp. 300-302.
    • (2003) Rev. Sci. Instrum. , vol.74 , pp. 300-302
    • Kozar Logar, J.1    Franko, M.2
  • 47
    • 0030777909 scopus 로고    scopus 로고
    • Near field thermal lens detector for gradient elution liquid chromatography
    • Steinle, E., Faubel, W. and Ache, H. J. (1997) Near field thermal lens detector for gradient elution liquid chromatography. Anal. Chim. Acta, 353, pp. 207-213.
    • (1997) Anal. Chim. Acta , vol.353 , pp. 207-213
    • Steinle, E.1    Faubel, W.2    Ache, H.J.3
  • 48
    • 35649014225 scopus 로고    scopus 로고
    • Determination of some neonicotinoid insecticides by liquid chromatography with thermal lens spectrometric detection
    • Guzsvany, V., Madzgalj, A., Trebse, P., Gaal, F. and Franko, M. (2007) Determination of some neonicotinoid insecticides by liquid chromatography with thermal lens spectrometric detection. Environ. Chem. Lett., 5, pp. 203-208.
    • (2007) Environ. Chem. Lett. , vol.5 , pp. 203-208
    • Guzsvany, V.1    Madzgalj, A.2    Trebse, P.3    Gaal, F.4    Franko, M.5
  • 50
    • 31444445159 scopus 로고    scopus 로고
    • Separation and direct detection of long chain fatty acids and their methylesters by the non-aqueous reversed phase HPLC and silver ion chromatography, combined with CO laser pumped thermal lens spectrometry
    • Bicanic, D., Mocnik, G., Franko, M., Niederlander, H. A. G., Van de Bovenkamp, P., Cozijnsen, J. and Van der Klift, E. (2006) Separation and direct detection of long chain fatty acids and their methylesters by the non-aqueous reversed phase HPLC and silver ion chromatography, combined with CO laser pumped thermal lens spectrometry. Instrum. Sci. Tech., 34, pp. 129-150.
    • (2006) Instrum. Sci. Tech. , vol.34 , pp. 129-150
    • Bicanic, D.1    Mocnik, G.2    Franko, M.3    Niederlander, H.A.G.4    Van de Bovenkamp, P.5    Cozijnsen, J.6    Van der Klift, E.7
  • 51
    • 0029049392 scopus 로고
    • On-line thermal lens spectrometric detection of Cr(III) and Cr(VI) after separation by ion chromatography
    • Sikovec, M., Novic, Mi., Hudnik, V. and Franko, M. (1995) On-line thermal lens spectrometric detection of Cr(III) and Cr(VI) after separation by ion chromatography. J. Chrom. A, 706, pp. 121-126.
    • (1995) J. Chrom. A , vol.706 , pp. 121-126
    • Sikovec, M.1    Novic, Mi.2    Hudnik, V.3    Franko, M.4
  • 52
    • 0030593368 scopus 로고    scopus 로고
    • Application of thermal lens spectrometric detection to the determination of heavy metals by ion chromatography
    • Sikovec, M., Novic, Mi. and Franko, M. (1996) Application of thermal lens spectrometric detection to the determination of heavy metals by ion chromatography. J. Chrom. A, 739, pp. 111-117.
    • (1996) J. Chrom. A , vol.739 , pp. 111-117
    • Sikovec, M.1    Novic, Mi.2    Franko, M.3
  • 53
    • 0032426076 scopus 로고    scopus 로고
    • Determination of iron complex matrices by ion chromatography with UV-Vis, thermal lens and amperometric detection using post-column reagents
    • Divjak, B., Franko, M. and Novic, Mi. (1998) Determination of iron complex matrices by ion chromatography with UV-Vis, thermal lens and amperometric detection using post-column reagents. J. Chrom. A, 829, pp. 167-174.
    • (1998) J. Chrom. A , vol.829 , pp. 167-174
    • Divjak, B.1    Franko, M.2    Novic, Mi.3
  • 54
    • 0035958367 scopus 로고    scopus 로고
    • Effect of organic solvents in the on-line thermal lens spectrometric detection of chromium(III) and chromium(VI) after ion chromatographic separation
    • Sikovec, M., Franko, M., Novic, Mi. and Veber, M. (2001) Effect of organic solvents in the on-line thermal lens spectrometric detection of chromium(III) and chromium(VI) after ion chromatographic separation. J. Chrom. A, 920, pp. 119-125.
    • (2001) J. Chrom. A , vol.920 , pp. 119-125
    • Sikovec, M.1    Franko, M.2    Novic, Mi.3    Veber, M.4
  • 55
    • 0024501083 scopus 로고
    • Attomole amino acid determination by capillary zone electrophoresis with thermooptical absorbance detection
    • Yu, M. and Dovichi, N. J. (1989) Attomole amino acid determination by capillary zone electrophoresis with thermooptical absorbance detection. Anal. Chem., 61, pp. 37-40.
    • (1989) Anal. Chem. , vol.61 , pp. 37-40
    • Yu, M.1    Dovichi, N.J.2
  • 56
    • 0024607450 scopus 로고
    • Attomole amino acid analysis: Capillary-zone electrophoresis with laser based thermo-optical detection
    • Yu, M. and Dovichi, N. J. (1989) Attomole amino acid analysis: Capillary-zone electrophoresis with laser based thermo-optical detection. Appl. Spectros., 43, pp. 196-201.
    • (1989) Appl. Spectros. , vol.43 , pp. 196-201
    • Yu, M.1    Dovichi, N.J.2
  • 57
    • 0032555767 scopus 로고    scopus 로고
    • Fiber optic modified thermal lens detector system for the determination of amino acids
    • Seidel, B. S. and Faubel, W. (1998) Fiber optic modified thermal lens detector system for the determination of amino acids. J. Chrom. A, 817, pp. 223-226.
    • (1998) J. Chrom. A , vol.817 , pp. 223-226
    • Seidel, B.S.1    Faubel, W.2
  • 58
    • 0031185716 scopus 로고    scopus 로고
    • Thermal lens detector system for capillary electrophoresis
    • Seidel, B. S., Faubel, W. and Ache, H. J. (1997) Thermal lens detector system for capillary electrophoresis. J. Biomed. Optic., 2, pp. 326-331.
    • (1997) J. Biomed. Optic. , vol.2 , pp. 326-331
    • Seidel, B.S.1    Faubel, W.2    Ache, H.J.3
  • 59
    • 0031776889 scopus 로고    scopus 로고
    • Miniaturized thermal lens device for capillary electrophoresis
    • Seidel, B. S. and Faubel, W. (1998) Miniaturized thermal lens device for capillary electrophoresis. Biomed. Chrom., 12, pp. 155-157.
    • (1998) Biomed. Chrom. , vol.12 , pp. 155-157
    • Seidel, B.S.1    Faubel, W.2
  • 60
    • 0034693355 scopus 로고    scopus 로고
    • Non-aqueous capillary electrophoresis of tamoxifen and its acid hydrolysis products
    • Li, X. F., Carter, S. J. and Dovichi, N. J. (2000) Non-aqueous capillary electrophoresis of tamoxifen and its acid hydrolysis products. J. Chrom. A, 895, pp. 81-85.
    • (2000) J. Chrom. A , vol.895 , pp. 81-85
    • Li, X.F.1    Carter, S.J.2    Dovichi, N.J.3
  • 61
    • 3042823271 scopus 로고    scopus 로고
    • Quantification of etoposide and etoposide phosphate in human plasma by micellar electrokinetic chromatography and near field thermal lens detection
    • Ragozina, N. Y., Putz, M., Heissler, S., Faubel, W. and Pyell, U. (2004) Quantification of etoposide and etoposide phosphate in human plasma by micellar electrokinetic chromatography and near field thermal lens detection. Anal. Chem., 76, pp. 3804-3809.
    • (2004) Anal. Chem. , vol.76 , pp. 3804-3809
    • Ragozina, N.Y.1    Putz, M.2    Heissler, S.3    Faubel, W.4    Pyell, U.5
  • 62
    • 0032782490 scopus 로고    scopus 로고
    • Capillary electrochromatography with thermo-optical absorbance detection for the analysis of phenylthiohydantoin-amino acids
    • Qi, M., Li, X. F., Stathakis, C. and Dovichi, N. J. (1999) Capillary electrochromatography with thermo-optical absorbance detection for the analysis of phenylthiohydantoin-amino acids. J. Chrom. A, 853, pp. 131-140.
    • (1999) J. Chrom. A , vol.853 , pp. 131-140
    • Qi, M.1    Li, X.F.2    Stathakis, C.3    Dovichi, N.J.4
  • 63
    • 30344437249 scopus 로고    scopus 로고
    • Optimization of instrumental parameters of a near-field thermal-lens detector for capillary electrophoresis
    • Proskurnin, M. A., Bendrysheva, S. N., Ragozina, N., Heissler, S., Faubel, W. and Pyell, U. (2005) Optimization of instrumental parameters of a near-field thermal-lens detector for capillary electrophoresis. Appl. Spectros., 59, pp. 1470-1479.
    • (2005) Appl. Spectros. , vol.59 , pp. 1470-1479
    • Proskurnin, M.A.1    Bendrysheva, S.N.2    Ragozina, N.3    Heissler, S.4    Faubel, W.5    Pyell, U.6
  • 65
    • 0037269140 scopus 로고    scopus 로고
    • An interface chip connection between capillary electrophoresis and thermal lens microscope
    • Uchiyama, K., Hibara, A., Sato, K., Hisamoto, H., Tokeshi, M. and Kitamori, T. (2003) An interface chip connection between capillary electrophoresis and thermal lens microscope. Electrophoresis, 24, pp. 179-184.
    • (2003) Electrophoresis , vol.24 , pp. 179-184
    • Uchiyama, K.1    Hibara, A.2    Sato, K.3    Hisamoto, H.4    Tokeshi, M.5    Kitamori, T.6
  • 66
    • 13444256172 scopus 로고    scopus 로고
    • Optimization of an interface chip for coupling capillary electrophoresis with thermal lens microscopic detection
    • Uchiyama, K., Tokeshi, M., Kikutani, Y., Hattori, A. and Kitamori, T. (2005) Optimization of an interface chip for coupling capillary electrophoresis with thermal lens microscopic detection. Anal. Sci., 21, pp. 49-52.
    • (2005) Anal. Sci. , vol.21 , pp. 49-52
    • Uchiyama, K.1    Tokeshi, M.2    Kikutani, Y.3    Hattori, A.4    Kitamori, T.5
  • 67
    • 0000848041 scopus 로고
    • Sub-femtomole determination of phenylthiohydantion-amino acids: Capillary electrophoresis and thermooptical detection
    • Waldron, K. C. and Dovichi, N. J. (1992) Sub-femtomole determination of phenylthiohydantion-amino acids: Capillary electrophoresis and thermooptical detection. Anal. Chem., 64, pp. 1396-1399.
    • (1992) Anal. Chem. , vol.64 , pp. 1396-1399
    • Waldron, K.C.1    Dovichi, N.J.2
  • 68
    • 0032562634 scopus 로고    scopus 로고
    • Use of dyes as indirect detection probes for the high-sensitivity determination of anions by capillary electrophoresis
    • Doble, P., Macka, M. and Haddad, P. R. (1998) Use of dyes as indirect detection probes for the high-sensitivity determination of anions by capillary electrophoresis. J. Chrom. A, 804, pp. 327-336.
    • (1998) J. Chrom. A , vol.804 , pp. 327-336
    • Doble, P.1    Macka, M.2    Haddad, P.R.3
  • 69
    • 0036148032 scopus 로고    scopus 로고
    • Optimisation of probe concentration in indirect photometric detection in capillary electrophoresis using highly absorbing dyes
    • Johns, C., Macka, M. and Haddad, P. R. (2002) Optimisation of probe concentration in indirect photometric detection in capillary electrophoresis using highly absorbing dyes. Electrophoresis, 23, pp. 43-48.
    • (2002) Electrophoresis , vol.23 , pp. 43-48
    • Johns, C.1    Macka, M.2    Haddad, P.R.3
  • 70
    • 0005829294 scopus 로고    scopus 로고
    • Miniaturized capillary electrophoretic drug analysis with photothermal detection
    • American Institute of Physics, Rome, Italy
    • Seidel, B. S. and Faubel, W. (1999) Miniaturized capillary electrophoretic drug analysis with photothermal detection. Photoacoustic and Photothermal Phenomena, 10th International Conference, 463, pp. 576-578. American Institute of Physics, Rome, Italy
    • (1999) Photoacoustic and Photothermal Phenomena, 10th International Conference , vol.463 , pp. 576-578
    • Seidel, B.S.1    Faubel, W.2
  • 71
    • 0030665996 scopus 로고    scopus 로고
    • On-column indirect photothermal interference detection for capillary zone electrophoresis
    • 122
    • Hu, Y., Cheng, J. and Deng, Y. (1997) On-column indirect photothermal interference detection for capillary zone electrophoresis. Analyst, 122, 122, pp. 1089-1093.
    • (1997) Analyst , vol.122 , pp. 1089-1093
    • Hu, Y.1    Cheng, J.2    Deng, Y.3
  • 72
    • 0001622232 scopus 로고    scopus 로고
    • Determination of iron in real samples by high performance capillary electrophoresis in combination with thermal lensing
    • Seidel, B. S. and Faubel, W. (1998) Determination of iron in real samples by high performance capillary electrophoresis in combination with thermal lensing. Fresen. J. Anal. Chem., 360, pp. 795-797.
    • (1998) Fresen. J. Anal. Chem. , vol.360 , pp. 795-797
    • Seidel, B.S.1    Faubel, W.2
  • 73
    • 0000074468 scopus 로고
    • Indirect thermo-optical detection for capillary electrophoresis
    • Ren, J., Li, B., Deng, Y. and Cheng, J. (1995) Indirect thermo-optical detection for capillary electrophoresis. Talanta, 42, pp. 1891-1895.
    • (1995) Talanta , vol.42 , pp. 1891-1895
    • Ren, J.1    Li, B.2    Deng, Y.3    Cheng, J.4
  • 74
    • 0039293206 scopus 로고    scopus 로고
    • Determination of organophosphate and carbamate pesticides in spiked samples of tap water and fruit juices by a biosensor with photothermal detection
    • Pogacnik, L. and Franko, M. (1999) Determination of organophosphate and carbamate pesticides in spiked samples of tap water and fruit juices by a biosensor with photothermal detection. Biosens. Bioelectron., 14, pp. 569-578.
    • (1999) Biosens. Bioelectron. , vol.14 , pp. 569-578
    • Pogacnik, L.1    Franko, M.2
  • 75
    • 33644811612 scopus 로고
    • A new rapid colorimetric determination of acetylcholinesterase activity
    • Ellman, G. L., Courtney, K. D., Andres, V. and Featherstone, R. M. (1961) A new rapid colorimetric determination of acetylcholinesterase activity. Biochem. Pharmacol., 7, pp. 88-95.
    • (1961) Biochem. Pharmacol. , vol.7 , pp. 88-95
    • Ellman, G.L.1    Courtney, K.D.2    Andres, V.3    Featherstone, R.M.4
  • 76
    • 0036355158 scopus 로고    scopus 로고
    • Validation of different commercially available cholinesterases for pesticide toxicity test
    • Pogacnik, L. and Franko, M. (2002) Validation of different commercially available cholinesterases for pesticide toxicity test. Ann. Chim., 92, pp. 93-101.
    • (2002) Ann. Chim. , vol.92 , pp. 93-101
    • Pogacnik, L.1    Franko, M.2
  • 77
    • 0141617340 scopus 로고    scopus 로고
    • Optimised calibration procedure for bioanalytical determination of organophosphate pesticides in apple juices by immobilized AChE
    • Meznar, K., Pihlar, B., Pogacnik, L. and Franko, M. (2003) Optimised calibration procedure for bioanalytical determination of organophosphate pesticides in apple juices by immobilized AChE. Acta Chim. Slov., 50, pp. 383-394.
    • (2003) Acta Chim. Slov. , vol.50 , pp. 383-394
    • Meznar, K.1    Pihlar, B.2    Pogacnik, L.3    Franko, M.4
  • 78
    • 0037210445 scopus 로고    scopus 로고
    • Determination of organophosphate and carbamate pesticides in vegetable samples by a photothermal biosensor
    • Pogacnik, L. and Franko, M. (2003) Determination of organophosphate and carbamate pesticides in vegetable samples by a photothermal biosensor. Biosens. Bioelectron., 18, pp. 1-9.
    • (2003) Biosens. Bioelectron. , vol.18 , pp. 1-9
    • Pogacnik, L.1    Franko, M.2
  • 79
    • 1642489080 scopus 로고    scopus 로고
    • Laser-induced degradation of organophosphates and monitoring of their toxicity by cholinesterase biosensors
    • Franko, M., Trebse, P. and Pogacnik, L. (2003) Laser-induced degradation of organophosphates and monitoring of their toxicity by cholinesterase biosensors. Crit. Rev. Anal. Chem., 33, pp. 285-290.
    • (2003) Crit. Rev. Anal. Chem. , vol.33 , pp. 285-290
    • Franko, M.1    Trebse, P.2    Pogacnik, L.3
  • 80
    • 27644533269 scopus 로고    scopus 로고
    • Photodegradation of pesticides and application of bioanalytical methods for their detection
    • Franko, M., Sarakha, M., Cibej, A., Boskin, A., Bavcon, M. and Trebse, P. (2005) Photodegradation of pesticides and application of bioanalytical methods for their detection. Pure Appl. Chem., 77, pp. 1727-1736.
    • (2005) Pure Appl. Chem. , vol.77 , pp. 1727-1736
    • Franko, M.1    Sarakha, M.2    Cibej, A.3    Boskin, A.4    Bavcon, M.5    Trebse, P.6
  • 81
    • 33846368498 scopus 로고    scopus 로고
    • Photodegradation of organophosphorous insecticides-Investigation of products and their toxicity using gas chromatography-mass spectrometry and AChE-thermal lens spectrometric bioassay
    • Bavcon-Kralj, M., Franko, M. and Trebse, P. (2007) Photodegradation of organophosphorous insecticides-Investigation of products and their toxicity using gas chromatography-mass spectrometry and AChE-thermal lens spectrometric bioassay. Chemosphere, 67, pp. 99-107.
    • (2007) Chemosphere , vol.67 , pp. 99-107
    • Bavcon-Kralj, M.1    Franko, M.2    Trebse, P.3
  • 82
    • 35348933748 scopus 로고    scopus 로고
    • Comparison of photocatalysis and photolysis of malathion, isomalathion, malaoxon, and commercial malathion-Products and toxicity studies
    • Bavcon-Kralj, M., Cernigoj, U., Franko, M. and Trebse, P. (2007) Comparison of photocatalysis and photolysis of malathion, isomalathion, malaoxon, and commercial malathion-Products and toxicity studies. Water Res., 41, pp. 4504-4514.
    • (2007) Water Res. , vol.41 , pp. 4504-4514
    • Bavcon-Kralj, M.1    Cernigoj, U.2    Franko, M.3    Trebse, P.4
  • 83
    • 36549023043 scopus 로고    scopus 로고
    • Applications of bioanalytical techniques in evaluating advanced oxidation processes in pesticide degradation
    • Bavcon-Kralj, M., Trebse, P. and Franko, M. (2007) Applications of bioanalytical techniques in evaluating advanced oxidation processes in pesticide degradation. Trends Anal. Chem., 26, pp. 1020-1031.
    • (2007) Trends Anal. Chem. , vol.26 , pp. 1020-1031
    • Bavcon-Kralj, M.1    Trebse, P.2    Franko, M.3
  • 84
    • 0036736986 scopus 로고    scopus 로고
    • A comparative photodegradation studies of methyl parathion by using Lumistox test and conductometric biosensor technique
    • Dzyadevych, S. V. and Chovelon, J. M. (2002) A comparative photodegradation studies of methyl parathion by using Lumistox test and conductometric biosensor technique. Mater. Sci. Eng. C, 21, pp. 55-60.
    • (2002) Mater. Sci. Eng. C , vol.21 , pp. 55-60
    • Dzyadevych, S.V.1    Chovelon, J.M.2
  • 85
    • 33645959870 scopus 로고    scopus 로고
    • Oxidation as a pre-step in determination of organophosphorus compounds by the AChE-TLS bioassay
    • Bavcon-Kralj, M., Trebse, P. and Franko, M. (2006) Oxidation as a pre-step in determination of organophosphorus compounds by the AChE-TLS bioassay. Acta Chim. Slov., 53, pp. 43-51.
    • (2006) Acta Chim. Slov. , vol.53 , pp. 43-51
    • Bavcon-Kralj, M.1    Trebse, P.2    Franko, M.3
  • 87
    • 45849090488 scopus 로고    scopus 로고
    • Oxidation of organophosphorus pesticides with chloroperoxidase enzyme in the presence of an ionic liquid as co-solvent
    • Boskin, A., Tran, C. D. and Franko, M. (2007) Oxidation of organophosphorus pesticides with chloroperoxidase enzyme in the presence of an ionic liquid as co-solvent. Environ. Chem. Lett.
    • (2007) Environ. Chem. Lett.
    • Boskin, A.1    Tran, C.D.2    Franko, M.3
  • 88
    • 85046242638 scopus 로고
    • The reactions of diphenylcarbazide and diphenylcarbazone with cations Part IV. Cations of Mn, Fe, Co, Ni, Cu, Zn, Cd, Sn and Pb
    • Balt, S. and van Elden, E. (1963) The reactions of diphenylcarbazide and diphenylcarbazone with cations Part IV. Cations of Mn, Fe, Co, Ni, Cu, Zn, Cd, Sn and Pb. Anal. Chim. Acta, 29, pp. 466-471.
    • (1963) Anal. Chim. Acta , vol.29 , pp. 466-471
    • Balt, S.1    van Elden, E.2
  • 91
    • 40949148671 scopus 로고    scopus 로고
    • Flow injection-thermal lens spectrometric determination of hexavalent chromium
    • Madzgalj, A., Baesso, M. L. and Franko, M. (2008) Flow injection-thermal lens spectrometric determination of hexavalent chromium. Eur. Phys. J., 153, pp. 503-506.
    • (2008) Eur. Phys. J. , vol.153 , pp. 503-506
    • Madzgalj, A.1    Baesso, M.L.2    Franko, M.3
  • 92
    • 33645083514 scopus 로고    scopus 로고
    • Determination of bilirubin by thermal lens spectrometry and studies of its transport into hepatic cells
    • Margon, A., Terdoslavich, M., Cocolo, A., Decorti, G., Passamonti, S. and Franko, M. (2005) Determination of bilirubin by thermal lens spectrometry and studies of its transport into hepatic cells. J. Phys. IV, 125, pp. 717-720.
    • (2005) J. Phys. IV , vol.125 , pp. 717-720
    • Margon, A.1    Terdoslavich, M.2    Cocolo, A.3    Decorti, G.4    Passamonti, S.5    Franko, M.6
  • 93
    • 27644599384 scopus 로고    scopus 로고
    • Uptake of bilirubin into HepG2 cells assayed by thermal lens spectroscopy: Function of bilitranslocase
    • Passamonti, S., Terdoslavich, M., Margon, A., Cocolo, A., Medic, N., Micali, F., Decorti, G. and Franko, M. (2005) Uptake of bilirubin into HepG2 cells assayed by thermal lens spectroscopy: Function of bilitranslocase. FEBS J., 272, pp. 5522-5535.
    • (2005) FEBS J. , vol.272 , pp. 5522-5535
    • Passamonti, S.1    Terdoslavich, M.2    Margon, A.3    Cocolo, A.4    Medic, N.5    Micali, F.6    Decorti, G.7    Franko, M.8
  • 94
    • 45849134642 scopus 로고    scopus 로고
    • Development and Application of New Laser Methods in Environmental and Biomedical Research
    • University of Nova Gorica, Nova Gorica, Slovenia
    • Madzgalj, A. (2007) Development and Application of New Laser Methods in Environmental and Biomedical Research, University of Nova Gorica, Nova Gorica, Slovenia
    • (2007)
    • Madzgalj, A.1
  • 95
    • 0000402744 scopus 로고
    • Photothermal microscopy with excitation and probe beams coaxial under the microscope and its application to microparticle analysis
    • Harada, M., Iwamoto, K., Kitamori, T. and Sawada, T. (1993) Photothermal microscopy with excitation and probe beams coaxial under the microscope and its application to microparticle analysis. Anal. Chem., 65, pp. 2938-2940.
    • (1993) Anal. Chem. , vol.65 , pp. 2938-2940
    • Harada, M.1    Iwamoto, K.2    Kitamori, T.3    Sawada, T.4
  • 96
    • 0842283952 scopus 로고    scopus 로고
    • Thermal lens microscopy and microchip chemistry
    • Kitamori, T., Tokeshi, M., Hibara, A. and Sato, K. (2004) Thermal lens microscopy and microchip chemistry. Anal. Chem., 76, pp. 52A-60A.
    • (2004) Anal. Chem. , vol.76
    • Kitamori, T.1    Tokeshi, M.2    Hibara, A.3    Sato, K.4
  • 97
    • 0033395546 scopus 로고    scopus 로고
    • Integration of flow injection analysis and zeptomole-level detection of the Fe(II)-o-phenanthroline complex
    • Sato, K., Tokeshi, M., Kitamori, T. and Sawada, T. (1999) Integration of flow injection analysis and zeptomole-level detection of the Fe(II)-o-phenanthroline complex. Anal. Sci., 15, pp. 641-645.
    • (1999) Anal. Sci. , vol.15 , pp. 641-645
    • Sato, K.1    Tokeshi, M.2    Kitamori, T.3    Sawada, T.4
  • 98
    • 4243365262 scopus 로고    scopus 로고
    • Optimization of the optical-scheme design for photothermal-lens microscopy in microchips
    • Proskrunin, M. A., Tokeshi, M., Slyadnev, M. N. and Kitamori, T. (2001) Optimization of the optical-scheme design for photothermal-lens microscopy in microchips. Anal. Sci., 17, pp. S454-S457.
    • (2001) Anal. Sci. , vol.17
    • Proskrunin, M.A.1    Tokeshi, M.2    Slyadnev, M.N.3    Kitamori, T.4
  • 99
    • 0037451606 scopus 로고    scopus 로고
    • Optimization of thermal lens microscopic measurements in a microchip
    • Proskrunin, M. A., Slyadnev, M. N., Tokeshi, M. and Kitamori, T. (2003) Optimization of thermal lens microscopic measurements in a microchip. Anal. Chim. Acta., 480, pp. 97-95.
    • (2003) Anal. Chim. Acta. , vol.480 , pp. 95-97
    • Proskrunin, M.A.1    Slyadnev, M.N.2    Tokeshi, M.3    Kitamori, T.4
  • 100
    • 0033755807 scopus 로고    scopus 로고
    • Integrated FIA for the determination of ascorbic acid and dehydroascorbic acid in a microfabricated glass-channel by thermal-lens microscopy
    • Sorouraddin, H. M., Hibara, A., Proskrunin, M. A. and Kitamori, T. (2000) Integrated FIA for the determination of ascorbic acid and dehydroascorbic acid in a microfabricated glass-channel by thermal-lens microscopy. Anal. Sci., 16, pp. 1033-1037.
    • (2000) Anal. Sci. , vol.16 , pp. 1033-1037
    • Sorouraddin, H.M.1    Hibara, A.2    Proskrunin, M.A.3    Kitamori, T.4
  • 101
    • 0034828710 scopus 로고    scopus 로고
    • Use of a thermal lens microscope in integrated catecholamine determination on a microchip
    • Sorouraddin, H. M., Hibara, A. and Kitamori, T. (2001) Use of a thermal lens microscope in integrated catecholamine determination on a microchip. Fresen. J. Anal. Chem., 371, pp. 91-96.
    • (2001) Fresen. J. Anal. Chem. , vol.371 , pp. 91-96
    • Sorouraddin, H.M.1    Hibara, A.2    Kitamori, T.3
  • 102
    • 28544447622 scopus 로고    scopus 로고
    • Development of the innovative nuclide separation system for high-level radioactive waste using microchannel chip-extraction behavior of metal ions from aqueous phase to organic phase in microchannel
    • Hotokezaka, H., Tokeshi, M., Harada, M., Kitamori, T. and Ikeda, Y. (2005) Development of the innovative nuclide separation system for high-level radioactive waste using microchannel chip-extraction behavior of metal ions from aqueous phase to organic phase in microchannel. Progr. Nucl. Energ., 47, pp. 439-447.
    • (2005) Progr. Nucl. Energ. , vol.47 , pp. 439-447
    • Hotokezaka, H.1    Tokeshi, M.2    Harada, M.3    Kitamori, T.4    Ikeda, Y.5
  • 103
    • 0033853180 scopus 로고    scopus 로고
    • Molecular transport between two phases in a microchannel
    • Sato, K., Tokeshi, M., Sawada, T. and Kitamori, T. (2000) Molecular transport between two phases in a microchannel. Anal. Sci., 16, pp. 455-456.
    • (2000) Anal. Sci. , vol.16 , pp. 455-456
    • Sato, K.1    Tokeshi, M.2    Sawada, T.3    Kitamori, T.4
  • 104
    • 0034644857 scopus 로고    scopus 로고
    • Integration of a microextraction system: Solvent extraction of co-2-nitroso-5-dimethylaminophenol complex on a microchip
    • Tokeshi, M., Minagawa, T. and Kitamori, T. (2000) Integration of a microextraction system: Solvent extraction of co-2-nitroso-5-dimethylaminophenol complex on a microchip. J. Chrom. A, 894, pp. 19-23.
    • (2000) J. Chrom. A , vol.894 , pp. 19-23
    • Tokeshi, M.1    Minagawa, T.2    Kitamori, T.3
  • 106
    • 0141886229 scopus 로고    scopus 로고
    • Integration of a wet analysis system on a glass chip: Determination of Co(II) as 2-nitroso-1-naphtol chelates by solvent extraction and thermal lens microscope
    • Minagawa, T., Tokeshi, M. and Kitamori, T. (2001) Integration of a wet analysis system on a glass chip: Determination of Co(II) as 2-nitroso-1-naphtol chelates by solvent extraction and thermal lens microscope. Lab on a Chip, 1, pp. 72-75.
    • (2001) Lab on a Chip , vol.1 , pp. 72-75
    • Minagawa, T.1    Tokeshi, M.2    Kitamori, T.3
  • 107
    • 0035326234 scopus 로고    scopus 로고
    • Determination of sub-yoctomole amounts of non-fluorescent molecules using a thermal lens microscope: Sub-single molecule determination
    • Tokeshi, M., Uchida, M., Hibara, A., Sawada, T. and Kitamori, T. (2001) Determination of sub-yoctomole amounts of non-fluorescent molecules using a thermal lens microscope: Sub-single molecule determination. Anal. Chem., 73, pp. 2112-2116.
    • (2001) Anal. Chem. , vol.73 , pp. 2112-2116
    • Tokeshi, M.1    Uchida, M.2    Hibara, A.3    Sawada, T.4    Kitamori, T.5
  • 108
    • 0034079719 scopus 로고    scopus 로고
    • Integration of a microextraction system on a glass chip: Ion-pair solvent extraction on Fe(II) with 4,7-diphenyl-1,10-phenanthrolinedisulfonic acid and tri-n-octylmethylammonium chloride
    • Tokeshi, M., Minagawa, T. and Kitamori, T. (2000) Integration of a microextraction system on a glass chip: Ion-pair solvent extraction on Fe(II) with 4,7-diphenyl-1,10-phenanthrolinedisulfonic acid and tri-n-octylmethylammonium chloride. Anal. Chem., 72, pp. 1711-1714.
    • (2000) Anal. Chem. , vol.72 , pp. 1711-1714
    • Tokeshi, M.1    Minagawa, T.2    Kitamori, T.3
  • 109
    • 0035891145 scopus 로고    scopus 로고
    • On-chip integration of sequential ion sensing system based on intermittent reagent pumping and formation of two-layer flow
    • Hisamoto, H., Horiuchi, T., Uchiyama, K., Tokeshi, M., Hibara, A. and Kitamori, T. (2001) On-chip integration of sequential ion sensing system based on intermittent reagent pumping and formation of two-layer flow. Anal. Chem., 73, pp. 5551-5556.
    • (2001) Anal. Chem. , vol.73 , pp. 5551-5556
    • Hisamoto, H.1    Horiuchi, T.2    Uchiyama, K.3    Tokeshi, M.4    Hibara, A.5    Kitamori, T.6
  • 110
    • 0035866679 scopus 로고    scopus 로고
    • On-chip integration of neutral ionophore-based ion pair extraction reaction
    • Hisamoto, H., Horiuchi, T., Tokeshi, M., Hibara, A. and Kitamori, T. (2001) On-chip integration of neutral ionophore-based ion pair extraction reaction. Anal. Chem., 73, pp. 1382-1386.
    • (2001) Anal. Chem. , vol.73 , pp. 1382-1386
    • Hisamoto, H.1    Horiuchi, T.2    Tokeshi, M.3    Hibara, A.4    Kitamori, T.5
  • 111
    • 0036534976 scopus 로고    scopus 로고
    • Continuous flow chemical processing on a microchip by combining micro unit operations and a multiphase flow network
    • Tokeshi, M., Minagawa, T., Uchiyama, K., Hibara, A., Sato, K., Hisamoto, H. and Kitamori, T. (2002) Continuous flow chemical processing on a microchip by combining micro unit operations and a multiphase flow network. Anal. Chem., 74, pp. 1565-1571.
    • (2002) Anal. Chem. , vol.74 , pp. 1565-1571
    • Tokeshi, M.1    Minagawa, T.2    Uchiyama, K.3    Hibara, A.4    Sato, K.5    Hisamoto, H.6    Kitamori, T.7
  • 112
    • 31044434528 scopus 로고    scopus 로고
    • Micro-multiphase laminar flows for the extraction and detection of carbaryl derivative
    • Smirnova, A., Mawatari, K., Hibara, A., Proskurnin, M. A. and Kitamori, T. (2006) Micro-multiphase laminar flows for the extraction and detection of carbaryl derivative. Anal. Chim. Acta, 558, pp. 69-74.
    • (2006) Anal. Chim. Acta , vol.558 , pp. 69-74
    • Smirnova, A.1    Mawatari, K.2    Hibara, A.3    Proskurnin, M.A.4    Kitamori, T.5
  • 113
    • 42049086521 scopus 로고    scopus 로고
    • Application of a micro multiphase laminar flow on a microchip for extraction and determination of derivatized carbamate pesticides
    • Smirnova, A., Shimura, K., Hibara, A., Proskurnin, M. A. and Kitamori, T. (2007) Application of a micro multiphase laminar flow on a microchip for extraction and determination of derivatized carbamate pesticides. Anal. Sci., 23, pp. 103-107.
    • (2007) Anal. Sci. , vol.23 , pp. 103-107
    • Smirnova, A.1    Shimura, K.2    Hibara, A.3    Proskurnin, M.A.4    Kitamori, T.5
  • 114
    • 10644256733 scopus 로고    scopus 로고
    • Microchip-based enzyme-linked immunosorbent assay (microELISA) system with thermal lens detection
    • Sato, K., Yamanaka, M., Hagino, T., Tokeshi, M., Kimura, H. and Kitamori, T. (2004) Microchip-based enzyme-linked immunosorbent assay (microELISA) system with thermal lens detection. Lab on a Chip, 4, pp. 570-575.
    • (2004) Lab on a Chip , vol.4 , pp. 570-575
    • Sato, K.1    Yamanaka, M.2    Hagino, T.3    Tokeshi, M.4    Kimura, H.5    Kitamori, T.6
  • 115
    • 33645242523 scopus 로고    scopus 로고
    • Monitoring of intercellular messengers released from neuron networks cultured in a microchip
    • Sato, K., Egami, A., Odake, T., Tokeshi, M., Aihara, M. and Kitamori, T. (2006) Monitoring of intercellular messengers released from neuron networks cultured in a microchip. J. Chrom. A, 1111, pp. 228-232.
    • (2006) J. Chrom. A , vol.1111 , pp. 228-232
    • Sato, K.1    Egami, A.2    Odake, T.3    Tokeshi, M.4    Aihara, M.5    Kitamori, T.6
  • 116
    • 0034644858 scopus 로고    scopus 로고
    • Non-contact photothermal control of enzyme reaction on a microchip by using a compact diode laser
    • Tanaka, Y., Slyadnev, M. N., Hibara, A., Tokeshi, M. and Kitamori, T. (2000) Non-contact photothermal control of enzyme reaction on a microchip by using a compact diode laser. J. Chrom. A, 894, pp. 45-51.
    • (2000) J. Chrom. A , vol.894 , pp. 45-51
    • Tanaka, Y.1    Slyadnev, M.N.2    Hibara, A.3    Tokeshi, M.4    Kitamori, T.5
  • 118
    • 0034654422 scopus 로고    scopus 로고
    • Integration of an immunosorbent assay system: Analysis of secretory human immunoglobulin a on polystyrene beads in a microchip
    • Sato, K., Tokeshi, M., Odake, T., Kimura, H., Ooi, T., Nakao, M. and Kitamori, T. (2000) Integration of an immunosorbent assay system: analysis of secretory human immunoglobulin a on polystyrene beads in a microchip. Anal. Chem., 72, pp. 1144-1147.
    • (2000) Anal. Chem. , vol.72 , pp. 1144-1147
    • Sato, K.1    Tokeshi, M.2    Odake, T.3    Kimura, H.4    Ooi, T.5    Nakao, M.6    Kitamori, T.7
  • 119
    • 0035866668 scopus 로고    scopus 로고
    • Determination of carcinoembryonic antigen in human sera by integrated bead-bed immunoassay in a microchip for cancer diagnosis
    • Sato, K., Tokeshi, M., Kimura, H. and Kitamori, T. (2001) Determination of carcinoembryonic antigen in human sera by integrated bead-bed immunoassay in a microchip for cancer diagnosis. Anal. Chem., 73, pp. 1213-1218.
    • (2001) Anal. Chem. , vol.73 , pp. 1213-1218
    • Sato, K.1    Tokeshi, M.2    Kimura, H.3    Kitamori, T.4
  • 121
    • 14544285903 scopus 로고    scopus 로고
    • Spectroelectrochemical detection using thermal lens microscopy with a glass-substrate microelectrode-microchannel chip
    • Kim, H. -B., Hagino, T., Sasaki, N., Watanabe, N. and Kitamori, T. (2005) Spectroelectrochemical detection using thermal lens microscopy with a glass-substrate microelectrode-microchannel chip. J. Electroanal. Chem., 577, pp. 47-53.
    • (2005) J. Electroanal. Chem. , vol.577 , pp. 47-53
    • Kim, H.-B.1    Hagino, T.2    Sasaki, N.3    Watanabe, N.4    Kitamori, T.5
  • 123
    • 33646140543 scopus 로고    scopus 로고
    • Circular dichroism thermal lens microscope for sensitive chiral analysis on microchip
    • Yamauchi, M., Mawatari, K., Hibara, A., Tokeshi, M. and Kitamori, T. (2006) Circular dichroism thermal lens microscope for sensitive chiral analysis on microchip. Anal. Chem., 78, pp. 2646-2650.
    • (2006) Anal. Chem. , vol.78 , pp. 2646-2650
    • Yamauchi, M.1    Mawatari, K.2    Hibara, A.3    Tokeshi, M.4    Kitamori, T.5
  • 124
    • 33646154021 scopus 로고    scopus 로고
    • UV-excitation thermal lens microscope for non-labeled and ultrasensitive detection of non-fluorescent molecules
    • Hiki, S., Mawatari, K., Hibara, A., Tokeshi, M. and Kitamori, T. (2006) UV-excitation thermal lens microscope for non-labeled and ultrasensitive detection of non-fluorescent molecules. Anal. Chem., 78, pp. 2859-2863.
    • (2006) Anal. Chem. , vol.78 , pp. 2859-2863
    • Hiki, S.1    Mawatari, K.2    Hibara, A.3    Tokeshi, M.4    Kitamori, T.5
  • 125
    • 0037435956 scopus 로고    scopus 로고
    • Microchannel-asssisted thermal-lens spectrometry for microchip analysis
    • Tamaki, E., Hibara, A., Tokeshi, M. and Kitamori, T. (2003) Microchannel-asssisted thermal-lens spectrometry for microchip analysis. J. Chrom. A, 987, pp. 197-204.
    • (2003) J. Chrom. A , vol.987 , pp. 197-204
    • Tamaki, E.1    Hibara, A.2    Tokeshi, M.3    Kitamori, T.4
  • 126
    • 45849110794 scopus 로고    scopus 로고
    • Using sub-microliter cylindrical sample cells for photothermal lens spectrometry of stable and photo-labile species
    • American Institute of Physics, Rome, Italy
    • Bialkowski, S. E. and Chartier, A. (1999) Using sub-microliter cylindrical sample cells for photothermal lens spectrometry of stable and photo-labile species. Photoacoustic and Photothermal Phenomena, 10th International Conference, 463, pp. 226-228. American Institute of Physics, Rome, Italy
    • (1999) Photoacoustic and Photothermal Phenomena, 10th International Conference , vol.463 , pp. 226-228
    • Bialkowski, S.E.1    Chartier, A.2
  • 127
    • 45849114149 scopus 로고    scopus 로고
    • Photothermal spectrometry in small liquid channels
    • Chartier, A. and Bialkowski, S. E. (2002) Photothermal spectrometry in small liquid channels. Anal. Sci., 17, pp. i99-i101.
    • (2002) Anal. Sci. , vol.17
    • Chartier, A.1    Bialkowski, S.E.2
  • 128
    • 31344475022 scopus 로고    scopus 로고
    • Toward million-fold sensitivity enhancement by sweeping in capillary electrophoresis combined with thermal lens microscopic detection using an interface chip
    • Kitagawa, F., Tsuneka, T., Akimoto, Y., Sueyoshi, K., Uchijama, K., Hattori, A. and Otsuka, K. (2006) Toward million-fold sensitivity enhancement by sweeping in capillary electrophoresis combined with thermal lens microscopic detection using an interface chip. J. Chrom. A, 1106, pp. 36-42.
    • (2006) J. Chrom. A , vol.1106 , pp. 36-42
    • Kitagawa, F.1    Tsuneka, T.2    Akimoto, Y.3    Sueyoshi, K.4    Uchijama, K.5    Hattori, A.6    Otsuka, K.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.