메뉴 건너뛰기




Volumn 1, Issue 3, 2007, Pages 185-196

In vitro quantification of guidewire flow-obstruction effect in model coronary stenoses for interventional diagnostic procedure

Author keywords

Guidewire diagnostic; Hemodynamics; Intermediate stenosis; Lesion flow coefficient (LFC); Transstenotic pressure drop

Indexed keywords

CORRELATION METHODS; DIAGNOSIS; MATHEMATICAL MODELS; PRESSURE DROP; PULSATILE FLOW;

EID: 44849099193     PISSN: 19326181     EISSN: None     Source Type: Journal    
DOI: 10.1115/1.2776336     Document Type: Article
Times cited : (20)

References (38)
  • 1
    • 84889234768 scopus 로고    scopus 로고
    • Measurement of Fractional Flow Reserve to Assess the Functional Severity of Coronary-Artery Stenoses
    • Pijls, N. H., De Bruyne, B., Peels, K., Van der Voort, P. H., Bonnier, H. J., Bartunek, J., and Koolen, J. J., 1996, "Measurement of Fractional Flow Reserve to Assess the Functional Severity of Coronary-Artery Stenoses," N. Engl. J. Med., 334(26), pp. 1703-1708.
    • (1996) N. Engl. J. Med , vol.334 , Issue.26 , pp. 1703-1708
    • Pijls, N.H.1    De Bruyne, B.2    Peels, K.3    Van der Voort, P.H.4    Bonnier, H.J.5    Bartunek, J.6    Koolen, J.J.7
  • 2
    • 0015966216 scopus 로고
    • Physiologic Basis for Assessing Critical Coronary Stenosis. Instantaneous Flow Response and Regional Distribution During Coronary Hyperemia as Measures of Coronary Flow Reserve
    • Pp
    • Gould, K. L., Lipscomb, K., and Hamilton, G. W., 1974, "Physiologic Basis for Assessing Critical Coronary Stenosis. Instantaneous Flow Response and Regional Distribution During Coronary Hyperemia as Measures of Coronary Flow Reserve," Am. J. Cardiol., 33(1), Pp. 87-94.
    • (1974) Am. J. Cardiol , vol.33 , Issue.1 , pp. 87-94
    • Gould, K.L.1    Lipscomb, K.2    Hamilton, G.W.3
  • 3
    • 1242336789 scopus 로고    scopus 로고
    • Single-Wire Pressure and Flow Velocity Measurement to Quantify Coronary Stenosis Hemodynamics and Effects of Percutaneous Interventions
    • Siebes, M., Verhoeff, B. J., Meuwisaen, M., de Winter, R. J., Spaan, J. A., and Pick, J. J., 2004. "Single-Wire Pressure and Flow Velocity Measurement to Quantify Coronary Stenosis Hemodynamics and Effects of Percutaneous Interventions," Circulation, 109(6), pp. 756-762.
    • (2004) Circulation , vol.109 , Issue.6 , pp. 756-762
    • Siebes, M.1    Verhoeff, B.J.2    Meuwisaen, M.3    de Winter, R.J.4    Spaan, J.A.5    Pick, J.J.6
  • 4
    • 0028806554 scopus 로고
    • Fractional Flow Reserve. A Useful Index to Evaluate the Influence of an Epicardial Coronary Stenosis on Myocardial Blood Flow
    • Pijls, N. H., Van Gelder, B., Van der Voort, P., Peels, K., Bracke, F., Bonnier, H. J., and el Gamal, M. I., 1995, "Fractional Flow Reserve. A Useful Index to Evaluate the Influence of an Epicardial Coronary Stenosis on Myocardial Blood Flow," Circulation, 92(11), pp. 3183-3193.
    • (1995) Circulation , vol.92 , Issue.11 , pp. 3183-3193
    • Pijls, N.H.1    Van Gelder, B.2    Van der Voort, P.3    Peels, K.4    Bracke, F.5    Bonnier, H.J.6    el Gamal, M.I.7
  • 5
    • 0031774880 scopus 로고    scopus 로고
    • Coronary Pressure Measurement and Fractional Flow Reserve
    • Pijls, N. H., and De Bruyne, B., 1998, "Coronary Pressure Measurement and Fractional Flow Reserve," Heart, 80(6), pp. 539-542.
    • (1998) Heart , vol.80 , Issue.6 , pp. 539-542
    • Pijls, N.H.1    De Bruyne, B.2
  • 7
    • 0022469787 scopus 로고
    • Measurement of Transstenotic Pressure Gradient During Percutaneous Transluminal Coronary Angioplasty
    • Anderson, H. V., Roubin, G. S., Leimgruber, P. P, Cox, W. R., Douglas, J. S., King, S. B., and Gruentzig, A. R., 1986, "Measurement of Transstenotic Pressure Gradient During Percutaneous Transluminal Coronary Angioplasty," Circulation, 73(6), pp. 1223-1230.
    • (1986) Circulation , vol.73 , Issue.6 , pp. 1223-1230
    • Anderson, H.V.1    Roubin, G.S.2    Leimgruber, P.P.3    Cox, W.R.4    Douglas, J.S.5    King, S.B.6    Gruentzig, A.R.7
  • 8
    • 0027176093 scopus 로고
    • Transstenotic Coronary Pressure Gradient Measurement in Humans: In Vitro and In Vivo Evaluation of a New Pressure Monitoring Angioplasty Guide Wire
    • De Bruyne, B., Pijls, N. H., Paulus, W. J., Vantrimpont, P. J., Sys, S. U., and Heyndrickx, G. R., 1993, "Transstenotic Coronary Pressure Gradient Measurement in Humans: In Vitro and In Vivo Evaluation of a New Pressure Monitoring Angioplasty Guide Wire," J. Am. Coll. Cardiol., 22(1), pp. 119-126.
    • (1993) J. Am. Coll. Cardiol , vol.22 , Issue.1 , pp. 119-126
    • De Bruyne, B.1    Pijls, N.H.2    Paulus, W.J.3    Vantrimpont, P.J.4    Sys, S.U.5    Heyndrickx, G.R.6
  • 9
    • 0021071207 scopus 로고
    • Phasic Pressure Gradients Across Coronary and Renal Artery Stenoses in Humans
    • Ganz, P., Harrington, D. P., Gaspar, J., and Barry, W. H., 1983, "Phasic Pressure Gradients Across Coronary and Renal Artery Stenoses in Humans," Am. Heart J., 106(6), pp. 1399-1406.
    • (1983) Am. Heart J , vol.106 , Issue.6 , pp. 1399-1406
    • Ganz, P.1    Harrington, D.P.2    Gaspar, J.3    Barry, W.H.4
  • 10
    • 0026504959 scopus 로고
    • Validation of a Doppler Guide Wire for Intravascular Measurement of Coronary Artery Flow Velocity
    • Doucette, J. W., Corl, P. D., Payne, H., Flynn, A. E., Goto, M., Nassi, M., and Segal, J., 1992, "Validation of a Doppler Guide Wire for Intravascular Measurement of Coronary Artery Flow Velocity," Circulation, 85(5), pp. 1899-1911.
    • (1992) Circulation , vol.85 , Issue.5 , pp. 1899-1911
    • Doucette, J.W.1    Corl, P.D.2    Payne, H.3    Flynn, A.E.4    Goto, M.5    Nassi, M.6    Segal, J.7
  • 11
    • 0030087668 scopus 로고    scopus 로고
    • Flow Rate-Pressure Drop Relation in Coronary Angioplasty: Catheter Obstruction Effect
    • Back, L. H., Kwack, E. Y., and Back, M. R., 1996, "Flow Rate-Pressure Drop Relation in Coronary Angioplasty: Catheter Obstruction Effect," ASME J. Biomech. Eng., 118(1), pp. 83-89.
    • (1996) ASME J. Biomech. Eng , vol.118 , Issue.1 , pp. 83-89
    • Back, L.H.1    Kwack, E.Y.2    Back, M.R.3
  • 12
    • 0026231965 scopus 로고
    • Initial Experiences with a Miniaturized Pressure Transducer During Coronary Angioplasty
    • Emanuelsson, H., Dohnal, M., Lamm, C., and Tenerz, L., 1991, "Initial Experiences with a Miniaturized Pressure Transducer During Coronary Angioplasty." Cathet Cardiovasc. Diagn., 24(2), pp. 137-143.
    • (1991) Cathet Cardiovasc. Diagn , vol.24 , Issue.2 , pp. 137-143
    • Emanuelsson, H.1    Dohnal, M.2    Lamm, C.3    Tenerz, L.4
  • 13
    • 0028370672 scopus 로고    scopus 로고
    • Back, L. H., 1994, Estimated Mean Flow Resistance Increase During Coronary Artery Catheterization,' J. Biomech., 27(2), pp. 169-175.
    • Back, L. H., 1994, "Estimated Mean Flow Resistance Increase During Coronary Artery Catheterization,' J. Biomech., 27(2), pp. 169-175.
  • 14
    • 0344878870 scopus 로고    scopus 로고
    • Impact of Doppler Guidewire Size and Flow Rates on Intravascular Velocity Profiles
    • Jenni, R., Buchi, M., Zweifel, H. J., and Ritter, M., 1998, "Impact of Doppler Guidewire Size and Flow Rates on Intravascular Velocity Profiles," Cathet Cardiovasc. Diagn., 45(1), pp. 96-100.
    • (1998) Cathet Cardiovasc. Diagn , vol.45 , Issue.1 , pp. 96-100
    • Jenni, R.1    Buchi, M.2    Zweifel, H.J.3    Ritter, M.4
  • 15
    • 0037414079 scopus 로고    scopus 로고
    • Is It Time to Measure Fractional Flow Reserve in All Patients?
    • Pijls, N. H. J., 2003, "Is It Time to Measure Fractional Flow Reserve in All Patients?, J. Am. Coll. Cardiol., 41(7), pp. 1122-1124.
    • (2003) J. Am. Coll. Cardiol , vol.41 , Issue.7 , pp. 1122-1124
    • Pijls, N.H.J.1
  • 16
    • 33846196264 scopus 로고    scopus 로고
    • Characterizing Momentum Change and Viscous Loss of a Hemodynamic Endpoint in Assessment of Coronary Lesions
    • Banerjee, R. K., Sinha Roy, A., Back, L. H., Back, M. R., Khoury, S. F., and Millard, R. W., 2007. "Characterizing Momentum Change and Viscous Loss of a Hemodynamic Endpoint in Assessment of Coronary Lesions," J. Biomech., 40(3), pp. 652-663.
    • (2007) J. Biomech , vol.40 , Issue.3 , pp. 652-663
    • Banerjee, R.K.1    Sinha Roy, A.2    Back, L.H.3    Back, M.R.4    Khoury, S.F.5    Millard, R.W.6
  • 17
    • 0021026662 scopus 로고
    • Experimental Study of Pulsatile and Steady Flow Through a Smooth Tube and an Atherosclerotic Coronary Artery Casting of Man
    • Cho, Y. I., Back, L. H., Crawford, D. W., and Cuffel, R. F., 1983, "Experimental Study of Pulsatile and Steady Flow Through a Smooth Tube and an Atherosclerotic Coronary Artery Casting of Man," J. Biomech., 16(11), pp. 933-946.
    • (1983) J. Biomech , vol.16 , Issue.11 , pp. 933-946
    • Cho, Y.I.1    Back, L.H.2    Crawford, D.W.3    Cuffel, R.F.4
  • 18
    • 0027199146 scopus 로고
    • Evaluation of a Transparent Blood Analog Fluid: Aqueous Xanthan Gum/Glycerin
    • Brookshier, K. A., and Tarbell, J. M., 1993, "Evaluation of a Transparent Blood Analog Fluid: Aqueous Xanthan Gum/Glycerin," Biorheology, 30(2), pp. 107-116.
    • (1993) Biorheology , vol.30 , Issue.2 , pp. 107-116
    • Brookshier, K.A.1    Tarbell, J.M.2
  • 19
    • 0025768839 scopus 로고
    • Effects of the Non-Newtonian Viscosity of Blood on Flows in a Diseased Arterial Vessel. Part I: Steady Flows
    • Cho, Y. I., and Kensey, K. R., 1991, "Effects of the Non-Newtonian Viscosity of Blood on Flows in a Diseased Arterial Vessel. Part I: Steady Flows," Biorheology, 28(3-4), pp. 241-262.
    • (1991) Biorheology , vol.28 , Issue.3-4 , pp. 241-262
    • Cho, Y.I.1    Kensey, K.R.2
  • 20
    • 0344234274 scopus 로고    scopus 로고
    • Effects of Diagnostic Guidewire Catheter Presence on Translesional Hemodynamic Measurements Across Significant Coronary Artery Stenoses
    • Banerjee, R. K., Back, L. H., and Back, M. R., 2003, "Effects of Diagnostic Guidewire Catheter Presence on Translesional Hemodynamic Measurements Across Significant Coronary Artery Stenoses," Biorheology, 40(6), pp. 613-635.
    • (2003) Biorheology , vol.40 , Issue.6 , pp. 613-635
    • Banerjee, R.K.1    Back, L.H.2    Back, M.R.3
  • 21
    • 0038621476 scopus 로고    scopus 로고
    • Physiological Flow Analysis in Significant Human Coronary Artery Stenoses
    • Banerjee, R. K., Back, L. H., Back, M. R., and Cho, Y. I., 2003, "Physiological Flow Analysis in Significant Human Coronary Artery Stenoses," Biorheology, 40(4), pp. 451-476.
    • (2003) Biorheology , vol.40 , Issue.4 , pp. 451-476
    • Banerjee, R.K.1    Back, L.H.2    Back, M.R.3    Cho, Y.I.4
  • 22
    • 0033805141 scopus 로고    scopus 로고
    • Physiological Flow Simulation in Residual Human Stenoses After Coronary Angioplasty
    • Banerjee, R. K., Back, L. H., Back, M. R., and Cho, Y. I., 2000. "Physiological Flow Simulation in Residual Human Stenoses After Coronary Angioplasty," ASME J. Biomech. Eng., 122(4), pp. 310-320.
    • (2000) ASME J. Biomech. Eng , vol.122 , Issue.4 , pp. 310-320
    • Banerjee, R.K.1    Back, L.H.2    Back, M.R.3    Cho, Y.I.4
  • 23
    • 0015650235 scopus 로고    scopus 로고
    • Young, D. F., and Tsai, F. Y., 1973, Flow Characteristics in Models of Arterial Stenoses-I Steady Flow; II Unsteady Flow, J. Biomech., 6(4), pp. 395-410;, 6(5), pp. 547-559.
    • Young, D. F., and Tsai, F. Y., 1973, "Flow Characteristics in Models of Arterial Stenoses-I Steady Flow; II Unsteady Flow," J. Biomech., 6(4), pp. 395-410;, 6(5), pp. 547-559.
  • 24
    • 0023726561 scopus 로고
    • Identifying and Measuring Severity of Coronary Artery Stenosis. Quantitative Coronary Arteriography and Positron Emission Tomography
    • Gould, K. L., 1988, "Identifying and Measuring Severity of Coronary Artery Stenosis. Quantitative Coronary Arteriography and Positron Emission Tomography," Circulation, 78(2), pp. 237-245.
    • (1988) Circulation , vol.78 , Issue.2 , pp. 237-245
    • Gould, K.L.1
  • 25
    • 21644479506 scopus 로고    scopus 로고
    • Delineating the Guide-Wire Flow Obstruction Effect in Assessment of Fractional Flow Reserve and Coronary Flow Reserve Measurements
    • Sinha Roy, A., Banerlee, R. K., Back, L. H., Back, M. R., Khoury, S., and Millard, R. W., 2005, "Delineating the Guide-Wire Flow Obstruction Effect in Assessment of Fractional Flow Reserve and Coronary Flow Reserve Measurements," Am. J. Physiol. Heart Circ. Physiol., 289(1), pp. H392-H397.
    • (2005) Am. J. Physiol. Heart Circ. Physiol , vol.289 , Issue.1
    • Sinha Roy, A.1    Banerlee, R.K.2    Back, L.H.3    Back, M.R.4    Khoury, S.5    Millard, R.W.6
  • 26
    • 0021677258 scopus 로고
    • Dynamic Mechanisms in Human Coronary Stenosis
    • Brown, B. G., Bolson, E. L., and Dodge, H. T., 1984, "Dynamic Mechanisms in Human Coronary Stenosis," Circulation, 70(6), pp. 917-922.
    • (1984) Circulation , vol.70 , Issue.6 , pp. 917-922
    • Brown, B.G.1    Bolson, E.L.2    Dodge, H.T.3
  • 27
    • 0035042425 scopus 로고    scopus 로고
    • Prediction of the Physiologic Severity of Coronary Lesions Using 3D IVUS: Validation by Direct Coronary Pressure Measurements
    • Takayama, T., and Hodgson, J. M., 2001, "Prediction of the Physiologic Severity of Coronary Lesions Using 3D IVUS: Validation by Direct Coronary Pressure Measurements," Catheter Cardiovasc. Interv., 53(1), pp. 48-55.
    • (2001) Catheter Cardiovasc. Interv , vol.53 , Issue.1 , pp. 48-55
    • Takayama, T.1    Hodgson, J.M.2
  • 30
    • 0034696537 scopus 로고    scopus 로고
    • Coronary Physiology Revisited: Practical Insights from the Cardiac Catheterization Laboratory
    • Kern, M. J., 2000, "Coronary Physiology Revisited: Practical Insights from the Cardiac Catheterization Laboratory," Circulation, 101(11), pp. 1344-1351.
    • (2000) Circulation , vol.101 , Issue.11 , pp. 1344-1351
    • Kern, M.J.1
  • 31
    • 0033987555 scopus 로고    scopus 로고
    • Practice and Potential Pitfalls of Coronary Pressure Measurement
    • Pijls, N. H., Kern, M. J., Yock, P. G., and De Bruyne, B., 2000, "Practice and Potential Pitfalls of Coronary Pressure Measurement," Catheter Cardiovasc. Interv., 49(1), pp. 1-16.
    • (2000) Catheter Cardiovasc. Interv , vol.49 , Issue.1 , pp. 1-16
    • Pijls, N.H.1    Kern, M.J.2    Yock, P.G.3    De Bruyne, B.4
  • 32
    • 0037408135 scopus 로고    scopus 로고
    • Measuring Pressure-Derived Fractional Flow Reserve Through Four French Diagnostic Catheters
    • Legalery, P., Seronde, M., Meneveau, N., Schiele, F., and Bassand, J. P., 2003, "Measuring Pressure-Derived Fractional Flow Reserve Through Four French Diagnostic Catheters," Am. J. Cardiol., 91(9), pp. 1075-1078.
    • (2003) Am. J. Cardiol , vol.91 , Issue.9 , pp. 1075-1078
    • Legalery, P.1    Seronde, M.2    Meneveau, N.3    Schiele, F.4    Bassand, J.P.5
  • 33
    • 0034511975 scopus 로고    scopus 로고
    • Intermediate Coronary Artery Stenosis: Evidence-Based Decisions in Interventions to Avoid the Oculostenotic Reflex
    • Patil, C. V., and Beyar, R., 2000, "Intermediate Coronary Artery Stenosis: Evidence-Based Decisions in Interventions to Avoid the Oculostenotic Reflex," Int. J. Cardiovasc Intervent, 3(4), pp. 195-206.
    • (2000) Int. J. Cardiovasc Intervent , vol.3 , Issue.4 , pp. 195-206
    • Patil, C.V.1    Beyar, R.2
  • 34
    • 0036158508 scopus 로고    scopus 로고
    • Simultaneous Intracoronary Pressure and Doppler Guidewires to Assess Coronary Stenosis: If One is Enough, Are Two Too Much?
    • Ruiz-Salmeron, R. J., Goicolea, J., Sanmartin, M., Mantilla, R., Sterling, J., and Romeo, D., 2002, "Simultaneous Intracoronary Pressure and Doppler Guidewires to Assess Coronary Stenosis: If One is Enough, Are Two Too Much?," Catheter Cardiovasc. Interv., 55(2), pp. 255-259.
    • (2002) Catheter Cardiovasc. Interv , vol.55 , Issue.2 , pp. 255-259
    • Ruiz-Salmeron, R.J.1    Goicolea, J.2    Sanmartin, M.3    Mantilla, R.4    Sterling, J.5    Romeo, D.6
  • 36
    • 0028182651 scopus 로고
    • Correlation of Pharmacological 99mTc-Sestamibi Myocardial Perfusion Imaging with Poststenotic Coronary Flow Reserve in Patients With Angiographically Intermediate Coronary Artery Stenoses
    • Miller, D. D., Donohue, T. J., Younis, L. T., Bach, R. G., Aguirre, F. V., Wittry, M. D., Goodgold, H. M., Chaitman, B. R., and Kern, M. J., 1994, "Correlation of Pharmacological 99mTc-Sestamibi Myocardial Perfusion Imaging with Poststenotic Coronary Flow Reserve in Patients With Angiographically Intermediate Coronary Artery Stenoses," Circulation, 89(5), pp. 2150-2160.
    • (1994) Circulation , vol.89 , Issue.5 , pp. 2150-2160
    • Miller, D.D.1    Donohue, T.J.2    Younis, L.T.3    Bach, R.G.4    Aguirre, F.V.5    Wittry, M.D.6    Goodgold, H.M.7    Chaitman, B.R.8    Kern, M.J.9
  • 37
    • 0029041671 scopus 로고
    • Relation Between Myocardial Fractional Flow Reserve Calculated from Coronary Pressure Measurements and Exercise-Induced Myocardial Ischemia
    • De Bruyne, B., Bartunek, J., Sys, S. U., and Heyndrickx, G. R., 1995, "Relation Between Myocardial Fractional Flow Reserve Calculated from Coronary Pressure Measurements and Exercise-Induced Myocardial Ischemia," Circulation, 92(1), pp. 39-46.
    • (1995) Circulation , vol.92 , Issue.1 , pp. 39-46
    • De Bruyne, B.1    Bartunek, J.2    Sys, S.U.3    Heyndrickx, G.R.4
  • 38
    • 0031568438 scopus 로고    scopus 로고
    • Comparison of Exercise Electrocardiography and Dobutamine Echocardiography with Invasively Assessed Myocardial Fractional Flow Reserve in Evaluation of Severity of Coronary Arterial Narrowing
    • Bartunek, J., Van Schuerbeeck, E., and De Bruyne, B., 1997, "Comparison of Exercise Electrocardiography and Dobutamine Echocardiography with Invasively Assessed Myocardial Fractional Flow Reserve in Evaluation of Severity of Coronary Arterial Narrowing," Am. J. Cardiol., 79(4), pp. 478-481.
    • (1997) Am. J. Cardiol , vol.79 , Issue.4 , pp. 478-481
    • Bartunek, J.1    Van Schuerbeeck, E.2    De Bruyne, B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.