-
1
-
-
0005351827
-
-
Hemisphere Publ. Co., New York, Chap. 4
-
A.J. Baker, Finite Element Computational Fluid Mechanics, Hemisphere Publ. Co., New York, 1983, Chap. 4, pp. 153-230.
-
(1983)
Finite Element Computational Fluid Mechanics
, pp. 153-230
-
-
Baker, A.J.1
-
2
-
-
0038085472
-
-
Fluent Inc., 10 Cavandish Court, Lebanon, NH 03766, USA
-
FIDAP Manual, Fluent Inc., 10 Cavandish Court, Lebanon, NH 03766, USA, 1998.
-
(1998)
FIDAP Manual
-
-
-
3
-
-
0022469787
-
Measurement of transstenotic pressure gradient during percutaneous transluminal coronary angioplasty
-
H.V. Anderson, G.S. Roubin, P.P. Leimgruber, W.R. Cox, J.S. Douglas Jr., S.B. King III and A.R. Gruentzig, Measurement of transstenotic pressure gradient during percutaneous transluminal coronary angioplasty, Circulation 73 (1986), 1223-1230.
-
(1986)
Circulation
, vol.73
, pp. 1223-1230
-
-
Anderson, H.V.1
Roubin, G.S.2
Leimgruber, P.P.3
Cox, W.R.4
Douglas Jr., J.S.5
King III, S.B.6
Gruentzig, A.R.7
-
4
-
-
0017096726
-
Flow patterns in stenotic blood vessel models
-
T. Azuma and T. Fukushima, Flow patterns in stenotic blood vessel models, Biorheology 13 (1976), 337-355.
-
(1976)
Biorheology
, vol.13
, pp. 337-355
-
-
Azuma, T.1
Fukushima, T.2
-
5
-
-
0028370672
-
Estimated mean flow resistance increase during coronary artery catheterization
-
L.H. Back, Estimated mean flow resistance increase during coronary artery catheterization, J. Biomech. 27 (1994), 169-175.
-
(1994)
J. Biomech.
, vol.27
, pp. 169-175
-
-
Back, L.H.1
-
6
-
-
0026966799
-
Some arterial wall shear stress estimates in coronary angioplasty
-
L.H. Back and T.A. Denton, Some arterial wall shear stress estimates in coronary angioplasty, Advances in Bioengineering, ASME BED. 22 (1992), 337-340.
-
(1992)
Advances in Bioengineering, ASME BED
, vol.22
, pp. 337-340
-
-
Back, L.H.1
Denton, T.A.2
-
7
-
-
0030087668
-
Flow rate-pressure drop relation in coronary angioplasty: Catheter obstruction effect
-
L.H. Back, E.Y. Kwack and M.R. Back, Flow rate-pressure drop relation in coronary angioplasty: catheter obstruction effect, ASME J. Biomech. Eng. 118 (1996), 83-89.
-
(1996)
ASME J. Biomech. Eng.
, vol.118
, pp. 83-89
-
-
Back, L.H.1
Kwack, E.Y.2
Back, M.R.3
-
8
-
-
0017447481
-
Analysis of pulsatile viscous blood flow through diseased coronary arteries of man
-
L.H. Back, J.R. Radbill and D.W. Crawford, Analysis of pulsatile viscous blood flow through diseased coronary arteries of man, J. Biomech. 10 (1977), 339-353.
-
(1977)
J. Biomech.
, vol.10
, pp. 339-353
-
-
Back, L.H.1
Radbill, J.R.2
Crawford, D.W.3
-
9
-
-
0015396531
-
Shear layer flow regimes and wave instabilities and reattachment lengths downstream of an abrupt circular channel expansion
-
L.H. Back and E.J. Roschke, Shear layer flow regimes and wave instabilities and reattachment lengths downstream of an abrupt circular channel expansion, ASME J. Appl. Mech. 39 (1972), 677-681.
-
(1972)
ASME J. Appl. Mech.
, vol.39
, pp. 677-681
-
-
Back, L.H.1
Roschke, E.J.2
-
10
-
-
0033052421
-
Catheter obstruction effect on pulsatile flow rate-pressure drop during coronary angioplasty
-
R.K. Banerjee, L.H. Back, M.R. Back and Y.I. Cho, Catheter obstruction effect on pulsatile flow rate-pressure drop during coronary angioplasty, ASME J. Biomech. Eng. 121 (1999), 281-289.
-
(1999)
ASME J. Biomech. Eng.
, vol.121
, pp. 281-289
-
-
Banerjee, R.K.1
Back, L.H.2
Back, M.R.3
Cho, Y.I.4
-
11
-
-
0038621476
-
Physiological flow analysis in significant human coronary artery stenoses
-
R.K. Banerjee, L.H. Back, M.R. Back and Y.I. Cho, Physiological flow analysis in significant human coronary artery stenoses, Biorheology 40(4) (2003), 451-476.
-
(2003)
Biorheology
, vol.40
, Issue.4
, pp. 451-476
-
-
Banerjee, R.K.1
Back, L.H.2
Back, M.R.3
Cho, Y.I.4
-
12
-
-
0021677258
-
Dynamic mechanisms in human coronary stenosis
-
B.G. Brown, E.L. Bolson and H.T. Dodge, Dynamic mechanisms in human coronary stenosis, Circulation 170 (1984), 917-922.
-
(1984)
Circulation
, vol.170
, pp. 917-922
-
-
Brown, B.G.1
Bolson, E.L.2
Dodge, H.T.3
-
13
-
-
0018145874
-
Disorder distal to modeled stenoses in steady and pulsatile flow
-
R.A. Cassanova and D.P. Giddens, Disorder distal to modeled stenoses in steady and pulsatile flow, J. Biomech. 11 (1978), 441-453.
-
(1978)
J. Biomech.
, vol.11
, pp. 441-453
-
-
Cassanova, R.A.1
Giddens, D.P.2
-
14
-
-
0021026662
-
Experimental study of pulsatile and steady flow through a smooth tube and an atherosclerotic coronary artery casting of man
-
Y.I. Cho, L.H. Back, D.W. Crawford and R.F. Cuffel, Experimental study of pulsatile and steady flow through a smooth tube and an atherosclerotic coronary artery casting of man, J. Biomech. 16 (1983), 933-946.
-
(1983)
J. Biomech.
, vol.16
, pp. 933-946
-
-
Cho, Y.I.1
Back, L.H.2
Crawford, D.W.3
Cuffel, R.F.4
-
15
-
-
0025768839
-
Effects of the non-Newtonian viscosity of blood on flows in a diseased arterial vessel: Part 1, steady flows
-
Y.I. Cho and K.R. Kensey, Effects of the non-Newtonian viscosity of blood on flows in a diseased arterial vessel: Part 1, steady flows, Biorheology 28 (1991), 241-262.
-
(1991)
Biorheology
, vol.28
, pp. 241-262
-
-
Cho, Y.I.1
Kensey, K.R.2
-
16
-
-
0027176093
-
Transstenotic coronary pressure gradient measurements in humans: In vitro and in vivo evaluation of a new pressure monitoring angioplasty guide wire
-
B. DeBruyne, N.H.J. Pijls, W.J. Paulus, P.J. Vantrimpont, S.U. Sys and G.R. Hendricks, Transstenotic coronary pressure gradient measurements in humans: in vitro and in vivo evaluation of a new pressure monitoring angioplasty guide wire, J. Am. Coll. Cardiol. 22 (1993), 119-126.
-
(1993)
J. Am. Coll. Cardiol.
, vol.22
, pp. 119-126
-
-
DeBruyne, B.1
Pijls, N.H.J.2
Paulus, W.J.3
Vantrimpont, P.J.4
Sys, S.U.5
Hendricks, G.R.6
-
17
-
-
0027420114
-
Intracoronary blood flow velocity and transstenotic pressure gradient using sensor-tip pressure and Doppler guidewires: A new technology for the assessment of stenosis severity in the catheterization laboratory
-
C. DiMario, P.J. de Feyter, C.J. Slager, P. de Jaegere, J.R.T.C. Roelandt and P.W. Serruys, Intracoronary blood flow velocity and transstenotic pressure gradient using sensor-tip pressure and Doppler guidewires: A new technology for the assessment of stenosis severity in the catheterization laboratory, Cathet. Cardiovasc. Diagn. 28 (1993), 311-319.
-
(1993)
Cathet. Cardiovasc. Diagn.
, vol.28
, pp. 311-319
-
-
DiMario, C.1
De Feyter, P.J.2
Slager, C.J.3
De Jaegere, P.4
Roelandt, J.R.T.C.5
Serruys, P.W.6
-
18
-
-
0026504959
-
Validation of a Doppler guidewire for intravascular measurements of coronary artery flow velocity
-
J.W. Doucette, P.D. Corl, H.M. Payne, A.E. Flynn, M.N. Goto, M. Nassi and J. Segal, Validation of a Doppler guidewire for intravascular measurements of coronary artery flow velocity, Circulation 85 (1992), 1899-1911.
-
(1992)
Circulation
, vol.85
, pp. 1899-1911
-
-
Doucette, J.W.1
Corl, P.D.2
Payne, H.M.3
Flynn, A.E.4
Goto, M.N.5
Nassi, M.6
Segal, J.7
-
19
-
-
0024456134
-
Flow dependent coronary artery dilation in humans
-
H. Drexler, A.M. Zeiher, H. Wollschlager, T. Meinertz, H. Just and T. Bonzel, Flow dependent coronary artery dilation in humans, Circulation 80 (1989), 466-474.
-
(1989)
Circulation
, vol.80
, pp. 466-474
-
-
Drexler, H.1
Zeiher, A.M.2
Wollschlager, H.3
Meinertz, T.4
Just, H.5
Bonzel, T.6
-
20
-
-
0007783337
-
High fidelity translesional pressure gradients during PTCA - Correlation with quantitative coronary angiography
-
H. Emanuelsson, C. Lamm, M. Dohnal and P.W. Serruys, High fidelity translesional pressure gradients during PTCA - Correlation with quantitative coronary angiography, J. Am. Coll. Cardiol. 21 (1993), 340A.
-
(1993)
J. Am. Coll. Cardiol.
, vol.21
-
-
Emanuelsson, H.1
Lamm, C.2
Dohnal, M.3
Serruys, P.W.4
-
21
-
-
0021811832
-
Usefulness of transstenotic coronary pressure gradient measurements during diagnostic catheterization
-
P. Ganz, R. Abben, P.L. Friedman, J.D. Garnic, W.H. Barry and D.C. Levin, Usefulness of transstenotic coronary pressure gradient measurements during diagnostic catheterization, Am. J. Cardiol. 55 (1985), 910-914.
-
(1985)
Am. J. Cardiol.
, vol.55
, pp. 910-914
-
-
Ganz, P.1
Abben, R.2
Friedman, P.L.3
Garnic, J.D.4
Barry, W.H.5
Levin, D.C.6
-
22
-
-
0021071207
-
Phasic pressure gradients across coronary and renal artery stenoses in humans
-
P. Ganz, D.P. Harrington, J. Gaspar and W.H. Barry, Phasic pressure gradients across coronary and renal artery stenoses in humans, Am. Heart J. 106 (1983), 1399-1406.
-
(1983)
Am. Heart J.
, vol.106
, pp. 1399-1406
-
-
Ganz, P.1
Harrington, D.P.2
Gaspar, J.3
Barry, W.H.4
-
23
-
-
0023276691
-
Compensatory enlargement of human atherosclerotic coronary arteries
-
S. Glagov, E. Weisenberg, C.K. Zarins, R. Stankunavicius and G.J. Kolettis, Compensatory enlargement of human atherosclerotic coronary arteries, New Engl. J. Med. 316(22) (1987), 1371-1375.
-
(1987)
New Engl. J. Med.
, vol.316
, Issue.22
, pp. 1371-1375
-
-
Glagov, S.1
Weisenberg, E.2
Zarins, C.K.3
Stankunavicius, R.4
Kolettis, G.J.5
-
24
-
-
0018760094
-
Nonoperative dilation of coronary artery stenosis: Percutaneous transluminal coronary angioplasty
-
A.R. Gruentzig, A. Senning and W.E. Siegenthaler, Nonoperative dilation of coronary artery stenosis: percutaneous transluminal coronary angioplasty, New Engl. J. Med. 301 (1979), 61-68.
-
(1979)
New Engl. J. Med.
, vol.301
, pp. 61-68
-
-
Gruentzig, A.R.1
Senning, A.2
Siegenthaler, W.E.3
-
25
-
-
0023205101
-
Analysis of flow characteristics in post-stenotic regions of the human coronary artery during bypass graft surgery
-
F. Kajiya, K. Tsujioka, Y. Ogasawara, Y. Wada, S. Matsouka, S. Kanazawa, O. Hiramatsu, S.I. Tadaoka, M. Goto and T. Fujiwara, Analysis of flow characteristics in post-stenotic regions of the human coronary artery during bypass graft surgery, Circulation 76 (1987), 1092-1100.
-
(1987)
Circulation
, vol.76
, pp. 1092-1100
-
-
Kajiya, F.1
Tsujioka, K.2
Ogasawara, Y.3
Wada, Y.4
Matsouka, S.5
Kanazawa, S.6
Hiramatsu, O.7
Tadaoka, S.I.8
Goto, M.9
Fujiwara, T.10
-
26
-
-
0027955111
-
Translesional pressure - Flow velocity assessment in patients: Part I
-
M.J. Kern, E.V. Aguirre, R.G. Bach, E.A. Caracciolo and T.J. Donohue, Translesional pressure - flow velocity assessment in patients: Part I, Cathet. Cardiovasc. Diagn. 31 (1994), 49-60.
-
(1994)
Cathet. Cardiovasc. Diagn.
, vol.31
, pp. 49-60
-
-
Kern, M.J.1
Aguirre, E.V.2
Bach, R.G.3
Caracciolo, E.A.4
Donohue, T.J.5
-
27
-
-
0021927733
-
Influence of intimal dissection on restenosis after successful coronary angioplasty
-
P.P. Leimgruber, G.S. Roubin, H.V. Anderson, C.E. Bredlau, H.B. Whitworth, J.S. Douglas, Jr., S.B. King III and A.R. Gruentzig, Influence of intimal dissection on restenosis after successful coronary angioplasty, Circulation 72 (1985), 530-535.
-
(1985)
Circulation
, vol.72
, pp. 530-535
-
-
Leimgruber, P.P.1
Roubin, G.S.2
Anderson, H.V.3
Bredlau, C.E.4
Whitworth, H.B.5
Douglas Jr., J.S.6
King III, S.B.7
Gruentzig, A.R.8
-
28
-
-
0023200926
-
The transstenotic pressure gradient trend as a predictor of acute complications after percutaneous transluminal coronary angioplasty
-
D.C.B. Redd, G.S. Roubin, P.P. Leimgruber, P. Abi-Mansour, J.S. Douglas, Jr. and S.B. King III, The transstenotic pressure gradient trend as a predictor of acute complications after percutaneous transluminal coronary angioplasty, Circulation 76 (1987), 792-801.
-
(1987)
Circulation
, vol.76
, pp. 792-801
-
-
Redd, D.C.B.1
Roubin, G.S.2
Leimgruber, P.P.3
Abi-Mansour, P.4
Douglas Jr., J.S.5
King III, S.B.6
-
29
-
-
0038762035
-
Return of diastolic predominant flow post-PTCA flow wire doppler guide wire case study
-
Mountain View, California
-
J. Segal, Return of diastolic predominant flow post-PTCA flow wire doppler guide wire case study, in: Cardiometrics, Mountain View, California, 1992.
-
(1992)
Cardiometrics
-
-
Segal, J.1
-
30
-
-
0026637436
-
Alterations of phasic coronary artery flow velocity in humans during percautaneous coronary angioplasty
-
J. Segal, M.J. Kern, N.A. Scott, S.B. King III, J.W. Doucette, R.R. Heuser, E. Ofili and R. Siegel, Alterations of phasic coronary artery flow velocity in humans during percautaneous coronary angioplasty, J. Am. Coll. Cardiol. 20 (1992), 276-286.
-
(1992)
J. Am. Coll. Cardiol.
, vol.20
, pp. 276-286
-
-
Segal, J.1
Kern, M.J.2
Scott, N.A.3
King III, S.B.4
Doucette, J.W.5
Heuser, R.R.6
Ofili, E.7
Siegel, R.8
-
31
-
-
0024439701
-
Control of shear stress in the epicardial coronary arteries of humans: Impairment by atherosclerosis
-
J.A. Vita, C.B. Treasure, P. Ganz, D.A. Cox, R.D. Fish and A.P. Selwyn, Control of shear stress in the epicardial coronary arteries of humans: impairment by atherosclerosis, J. Am. Coll. Cardiol. 14 (1989), 1193-1199.
-
(1989)
J. Am. Coll. Cardiol.
, vol.14
, pp. 1193-1199
-
-
Vita, J.A.1
Treasure, C.B.2
Ganz, P.3
Cox, D.A.4
Fish, R.D.5
Selwyn, A.P.6
-
32
-
-
0023875978
-
The effect of coronary angioplasty on coronary flow reserve
-
R.F. Wilson, M.R. Johnson, M.L. Marcus, P.E.G. Aylward, D.J. Skorton, S. Collins and C.W. White, The effect of coronary angioplasty on coronary flow reserve, Circulation 77 (1988), 873-885.
-
(1988)
Circulation
, vol.77
, pp. 873-885
-
-
Wilson, R.F.1
Johnson, M.R.2
Marcus, M.L.3
Aylward, P.E.G.4
Skorton, D.J.5
Collins, S.6
White, C.W.7
-
33
-
-
0027612802
-
Caveat emptor, A clinician's guide to assessing the physiologic significance of arterial stenoses
-
R.F. Wilson and D.D. Laxson, Caveat emptor, A clinician's guide to assessing the physiologic significance of arterial stenoses, Cathet. Cardiovasc. Diagn. 29 (1993), 93-98.
-
(1993)
Cathet. Cardiovasc. Diagn.
, vol.29
, pp. 93-98
-
-
Wilson, R.F.1
Laxson, D.D.2
-
34
-
-
0018340074
-
Initiation of turbulence in models of arterial stenoses
-
W. Yongchareon and D.F. Young, Initiation of turbulence in models of arterial stenoses, J. Biomech. 12 (1979), 185-196.
-
(1979)
J. Biomech.
, vol.12
, pp. 185-196
-
-
Yongchareon, W.1
Young, D.F.2
-
35
-
-
0015650235
-
Flow characteristics in models of arterial stenosis -1 steady flow and -II unsteady flow
-
D.F. Young and F.Y. Tsai, Flow characteristics in models of arterial stenosis -1 steady flow and -II unsteady flow, J. Biomech. 6 (1973), 395-410, 547-559.
-
(1973)
J. Biomech.
, vol.6
, pp. 395-410
-
-
Young, D.F.1
Tsai, F.Y.2
|