메뉴 건너뛰기




Volumn 120, Issue 7-8, 2008, Pages 217-223

Using a laryngeal tube during cardiac arrest reduces "no flow time" in a manikin study: A comparison between laryngeal tube and endotracheal tube

Author keywords

Advanced life support; Airway management; Cardiopulmonary resuscitation; Emergency physician; Laryngeal tube; Tracheal intubation

Indexed keywords

AIRWAY; ANESTHETIC EQUIPMENT; ARTICLE; AUDIOVISUAL EQUIPMENT; CLINICAL PRACTICE; DEFIBRILLATION; EMERGENCY CARE; EMERGENCY PHYSICIAN; ENDOTRACHEAL INTUBATION; ENDOTRACHEAL TUBE; HEART ARREST; INTERMETHOD COMPARISON; LARYNGEAL TUBE; LARYNX; MEDICAL INSTRUMENTATION; PRACTICE GUIDELINE; RESUSCITATION; TRACHEA;

EID: 44649149017     PISSN: 00435325     EISSN: None     Source Type: Journal    
DOI: 10.1007/s00508-008-0953-1     Document Type: Article
Times cited : (20)

References (34)
  • 1
    • 28544440129 scopus 로고    scopus 로고
    • European Resuscitation Council Guidelines for Resuscitation 2005
    • European Resuscitation Council. S1
    • European Resuscitation Council (2005) European Resuscitation Council Guidelines for Resuscitation 2005. Resuscitation 67 (S1): S1-S189
    • (2005) Resuscitation , vol.67
  • 2
    • 0037076435 scopus 로고    scopus 로고
    • Effects of interrupting precordial compressions on the calculated probability of defibrillation success during out-of-hospital cardiac arrest
    • Eftestol T, Sunde K, Steen PA (2002) Effects of interrupting precordial compressions on the calculated probability of defibrillation success during out-of-hospital cardiac arrest. Circulation 105: 2270-2273
    • (2002) Circulation , vol.105 , pp. 2270-2273
    • Eftestol, T.1    Sunde, K.2    Steen, P.A.3
  • 3
    • 0035868578 scopus 로고    scopus 로고
    • Emergency airway management - Comparison of various strategies in an unsecured airway
    • Dörges V, Ocker H, Neubert E, Schumann T, Wenzel V (2001) Emergency airway management - comparison of various strategies in an unsecured airway. Wien Klin Wochenschr 113: 186-193
    • (2001) Wien Klin Wochenschr , vol.113 , pp. 186-193
    • Dörges, V.1    Ocker, H.2    Neubert, E.3    Schumann, T.4    Wenzel, V.5
  • 5
    • 0032881248 scopus 로고    scopus 로고
    • A new prototype for airway management in an emergency: The laryngeal tube
    • Agro F, Cataldo R, Alfano A, Galli B (1999) A new prototype for airway management in an emergency: the laryngeal tube. Resuscitation 41: 284-286
    • (1999) Resuscitation , vol.41 , pp. 284-286
    • Agro, F.1    Cataldo, R.2    Alfano, A.3    Galli, B.4
  • 7
    • 28844478477 scopus 로고    scopus 로고
    • The laryngeal tube
    • Asai T, Shingu K (2005) The laryngeal tube. Br J Anaesth 95: 729-736
    • (2005) Br J Anaesth , vol.95 , pp. 729-736
    • Asai, T.1    Shingu, K.2
  • 10
    • 0035192091 scopus 로고    scopus 로고
    • Intubating laryngeal mask airway, laryngeal tube, 1100 ml self-inflating bag - Alternatives for basic life support?
    • Doerges V, Wenzel V, Schumann T, Neubert E, Ocker H, Gerlach K (2001) Intubating laryngeal mask airway, laryngeal tube, 1100 ml self-inflating bag - alternatives for basic life support? Resuscitation 51: 185-191
    • (2001) Resuscitation , vol.51 , pp. 185-191
    • Doerges, V.1    Wenzel, V.2    Schumann, T.3    Neubert, E.4    Ocker, H.5    Gerlach, K.6
  • 11
    • 33746956859 scopus 로고    scopus 로고
    • The declaration of Helsinki 2000: Ethical principles and the dignity of difference
    • Salako SE (2006) The declaration of Helsinki 2000: Ethical principles and the dignity of difference. Med Law 25: 341-354
    • (2006) Med Law , vol.25 , pp. 341-354
    • Salako, S.E.1
  • 13
    • 0342804325 scopus 로고    scopus 로고
    • The laryngeal tube: A new simple airway device
    • Doerges V, Ocker H, Wenzel V (2000) The laryngeal tube: a new simple airway device. Anaesth Analg 90: 1220-1222
    • (2000) Anaesth Analg , vol.90 , pp. 1220-1222
    • Doerges, V.1    Ocker, H.2    Wenzel, V.3
  • 14
    • 0036591380 scopus 로고    scopus 로고
    • Use of the laryngeal tube in a patient with unstable neck
    • Asai T (2002) Use of the laryngeal tube in a patient with unstable neck. Can J Anaesth 49: 642-643
    • (2002) Can J Anaesth , vol.49 , pp. 642-643
    • Asai, T.1
  • 15
    • 0033719585 scopus 로고    scopus 로고
    • Efficacy of the laryngeal tube during intermittent positive-pressure ventilation
    • Asai T, Murao K, Shingu K (2000) Efficacy of the laryngeal tube during intermittent positive-pressure ventilation. Anaesthesia 55: 1099-1102
    • (2000) Anaesthesia , vol.55 , pp. 1099-1102
    • Asai, T.1    Murao, K.2    Shingu, K.3
  • 16
  • 17
    • 0033635719 scopus 로고    scopus 로고
    • Emergency airway management by intensive care nurses with the intubating laryngeal mask airway and the laryngeal tube
    • Doerges V, Wenzel V, Neubert E, Schmucker P (2000) Emergency airway management by intensive care nurses with the intubating laryngeal mask airway and the laryngeal tube. Crit Care 4: 369-375
    • (2000) Crit Care , vol.4 , pp. 369-375
    • Doerges, V.1    Wenzel, V.2    Neubert, E.3    Schmucker, P.4
  • 18
    • 0036176297 scopus 로고    scopus 로고
    • Use of the laryngeal tube for out-of-hospital resuscitation
    • Genzwuerker HV, Dhonau S, Ellinger K (2002) Use of the laryngeal tube for out-of-hospital resuscitation. Resuscitation 52: 221-224
    • (2002) Resuscitation , vol.52 , pp. 221-224
    • Genzwuerker, H.V.1    Dhonau, S.2    Ellinger, K.3
  • 19
    • 0035662387 scopus 로고    scopus 로고
    • Assessment of the use of the laryngeal tube for cardiopulmonary resuscitation in a manikin
    • Genzwuerker HV, Finteis T, Slabshi D, Groeschel J, Ellinger K (2001) Assessment of the use of the laryngeal tube for cardiopulmonary resuscitation in a manikin. Resuscitation 51: 291-294
    • (2001) Resuscitation , vol.51 , pp. 291-294
    • Genzwuerker, H.V.1    Finteis, T.2    Slabshi, D.3    Groeschel, J.4    Ellinger, K.5
  • 21
    • 21544445586 scopus 로고    scopus 로고
    • The use of laryngeal tube by nurses in out-of-hospital emergencies: Preliminary experience
    • Kette F, Reffo I, Giordani G, Buzzi F, Borean V, Cimarosti R, et al (2005) The use of laryngeal tube by nurses in out-of-hospital emergencies: preliminary experience. Resuscitation 66: 21-25
    • (2005) Resuscitation , vol.66 , pp. 21-25
    • Kette, F.1    Reffo, I.2    Giordani, G.3    Buzzi, F.4    Borean, V.5    Cimarosti, R.6
  • 22
    • 23844503650 scopus 로고    scopus 로고
    • Randomized crossover comparison of the ProSeal laryngeal mask airway with the Laryngeal Tube Sonda during anaesthesia with controlled ventilation
    • Cook TM, Cranshaw J (2005) Randomized crossover comparison of the ProSeal laryngeal mask airway with the Laryngeal Tube Sonda during anaesthesia with controlled ventilation. Br J Anaesth 95: 261-266
    • (2005) Br J Anaesth , vol.95 , pp. 261-266
    • Cook, T.M.1    Cranshaw, J.2
  • 23
    • 0033635719 scopus 로고    scopus 로고
    • Emergency airway management by intensive care nurses with the intubating laryngeal mask airway and the laryngeal tube
    • Doerges V, Wenzel V, Neubert E, Schmucker P (2000) Emergency airway management by intensive care nurses with the intubating laryngeal mask airway and the laryngeal tube. Crit Care 4: 369-375
    • (2000) Crit Care , vol.4 , pp. 369-375
    • Doerges, V.1    Wenzel, V.2    Neubert, E.3    Schmucker, P.4
  • 24
    • 0036784844 scopus 로고    scopus 로고
    • A comparison of the laryngeal tube with the laryngeal mask airway during routine surgical procedures
    • Ocker H, Wenzel V, Schmucker P, Steinfath M, Doerges V (2002) A comparison of the laryngeal tube with the laryngeal mask airway during routine surgical procedures. Anaest Analg 95: 1094-1097
    • (2002) Anaest Analg , vol.95 , pp. 1094-1097
    • Ocker, H.1    Wenzel, V.2    Schmucker, P.3    Steinfath, M.4    Doerges, V.5
  • 25
    • 33344471086 scopus 로고    scopus 로고
    • Comparison between the laryngeal tube S and endotracheal intubation. Simulation of securing the airway in an emergency situation
    • Thierbach A, Piepho T, Kleine-Weischede B, Haag G, Maybauer M, Werner C (2006) Comparison between the laryngeal tube S and endotracheal intubation. Simulation of securing the airway in an emergency situation. Anaesthesist 55: 154-159
    • (2006) Anaesthesist , vol.55 , pp. 154-159
    • Thierbach, A.1    Piepho, T.2    Kleine-Weischede, B.3    Haag, G.4    Maybauer, M.5    Werner, C.6
  • 26
    • 0042329318 scopus 로고    scopus 로고
    • Randomized comparison of laryngeal tube with classic laryngeal mask airway for anaesthesia with controlled ventilation
    • Cook TM, Mc Cormick B, Asai T (2003) Randomized comparison of laryngeal tube with classic laryngeal mask airway for anaesthesia with controlled ventilation. Br J Anaesth 91: 373-378
    • (2003) Br J Anaesth , vol.91 , pp. 373-378
    • Cook, T.M.1    Mc Cormick, B.2    Asai, T.3
  • 27
    • 0242467651 scopus 로고    scopus 로고
    • Randomized crossover comparison of the ProSeal laryngeal mask airway with the Laryngeal Tube during anaesthesia with controlled ventilation
    • Cook TM, Mc Kinstry C, Hardy R, Twigg S (2003) Randomized crossover comparison of the ProSeal laryngeal mask airway with the Laryngeal Tube during anaesthesia with controlled ventilation. Br J Anaesth 91: 678-83
    • (2003) Br J Anaesth , vol.91 , pp. 678-83
    • Cook, T.M.1    Mc Kinstry, C.2    Hardy, R.3    Twigg, S.4
  • 28
    • 35648930866 scopus 로고    scopus 로고
    • Management of the difficult airway - An evaluation of alternative devices in the German emergency medical services
    • Weilbach C, Skorzik J, Ruschulte H, Callies A, Bund M, Piepenbrock S, et al (2007) Management of the difficult airway - An evaluation of alternative devices in the German emergency medical services. Anesth Intensivmed 48: 438-447
    • (2007) Anesth Intensivmed , vol.48 , pp. 438-447
    • Weilbach, C.1    Skorzik, J.2    Ruschulte, H.3    Callies, A.4    Bund, M.5    Piepenbrock, S.6
  • 29
    • 23844492898 scopus 로고    scopus 로고
    • Recommendation of the minimal volume technique to avoid tongue engorgement with prolonged use of the esophageal-tracheal combitube
    • Rabitsch W, Kostler WJ, Burgmann H, Krafft P, Frass M (2005) Recommendation of the minimal volume technique to avoid tongue engorgement with prolonged use of the esophageal-tracheal combitube. Ann Emerg Med 45: 565-566
    • (2005) Ann Emerg Med , vol.45 , pp. 565-566
    • Rabitsch, W.1    Kostler, W.J.2    Burgmann, H.3    Krafft, P.4    Frass, M.5
  • 30
    • 0037382375 scopus 로고    scopus 로고
    • Comparison of a conventional tracheal airway with the Combitube in an urban emergency medical services system run by physicians
    • Rabitsch W, Schellongowski P, Staudinger T, Hofbauer R, Dufek V, Eder B, et al (2003) Comparison of a conventional tracheal airway with the Combitube in an urban emergency medical services system run by physicians. Resuscitation 57: 27-32
    • (2003) Resuscitation , vol.57 , pp. 27-32
    • Rabitsch, W.1    Schellongowski, P.2    Staudinger, T.3    Hofbauer, R.4    Dufek, V.5    Eder, B.6
  • 31
    • 0347359223 scopus 로고    scopus 로고
    • Endotracheal intubation and esophageal tracheal Combitube insertion by regular ambulance attendants: A comparative trial
    • Rumball C, Macdonald D, Barber P, Wong H, Schmecher C (2004) Endotracheal intubation and esophageal tracheal Combitube insertion by regular ambulance attendants: a comparative trial. Prehosp Emerg Care 8: 15-22
    • (2004) Prehosp Emerg Care , vol.8 , pp. 15-22
    • Rumball, C.1    MacDonald, D.2    Barber, P.3    Wong, H.4    Schmecher, C.5
  • 33
    • 42549123756 scopus 로고    scopus 로고
    • A comparison of four different advanced airway mannequins for training DAS guidelines
    • Cook TM, Bayley G, Jordan G, Silsby J (2007) A comparison of four different advanced airway mannequins for training DAS guidelines. Anaesthesia 62: 708-712
    • (2007) Anaesthesia , vol.62 , pp. 708-712
    • Cook, T.M.1    Bayley, G.2    Jordan, G.3    Silsby, J.4
  • 34
    • 33947654834 scopus 로고    scopus 로고
    • A comparison of four different advanced airway mannequins for training SAD insertion
    • Jackson KM, Cook TM (2007) A comparison of four different advanced airway mannequins for training SAD insertion. Anaesthesia 62: 388-393
    • (2007) Anaesthesia , vol.62 , pp. 388-393
    • Jackson, K.M.1    Cook, T.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.