메뉴 건너뛰기




Volumn 57, Issue 3, 2008, Pages 101-112

Evaluation of a 2k CCD camera with an epitaxially grown CsI scintillator for recording energy-filtered electron cryo-micrographs

Author keywords

Catalase; CCD camera; Electron microscopy; Energy filtered imaging; Epitaxially grown CsI; Modulation transfer function

Indexed keywords

CATALASE;

EID: 44649107822     PISSN: 00220744     EISSN: 14779986     Source Type: Journal    
DOI: 10.1093/jmicro/dfn006     Document Type: Article
Times cited : (4)

References (26)
  • 1
    • 0032599786 scopus 로고    scopus 로고
    • Performance of a 2k CCD camera designed for electron crystallography at 400 kV
    • Downing K H and Hendrickson F M (1999) Performance of a 2k CCD camera designed for electron crystallography at 400 kV. Ultramicroscopy 75: 215-233.
    • (1999) Ultramicroscopy , vol.75 , pp. 215-233
    • Downing, K.H.1    Hendrickson, F.M.2
  • 2
    • 0032949908 scopus 로고    scopus 로고
    • Cooled CCD detector with tapered fibre optics for recording electron diffraction patterns S
    • Faruqi A R, Henderson R and Subramaniam (1999) Cooled CCD detector with tapered fibre optics for recording electron diffraction patterns S. Ultramicroscopy 75: 235-250.
    • (1999) Ultramicroscopy , vol.75 , pp. 235-250
    • Faruqi, A.R.1    Henderson, R.2    Subramaniam3
  • 3
    • 0033012041 scopus 로고    scopus 로고
    • Evaluation of gadolinium oxysulphide (P43) phosphor used in CCD detectors for electron microscopy
    • Faruqi A R and Tyrell G G (1999) Evaluation of gadolinium oxysulphide (P43) phosphor used in CCD detectors for electron microscopy Ultramicroscopy 76: 69-75.
    • (1999) Ultramicroscopy , vol.76 , pp. 69-75
    • Faruqi, A.R.1    Tyrell, G.G.2
  • 4
    • 0027669999 scopus 로고
    • Analysis of electron image detection efficiency of slow-scan CCD cameras
    • Ishizuka K (1993) Analysis of electron image detection efficiency of slow-scan CCD cameras. Ultramicroscopy 52: 7-20.
    • (1993) Ultramicroscopy , vol.52 , pp. 7-20
    • Ishizuka, K.1
  • 5
    • 0030221780 scopus 로고    scopus 로고
    • Measurement of the modulation transfer function of a slow-scan CCD camera on a TEM using a thin amorphous film as test signal
    • van Zwet E J and Zandberge H W (1996) Measurement of the modulation transfer function of a slow-scan CCD camera on a TEM using a thin amorphous film as test signal. Ultramicroscopy 64: 49-55.
    • (1996) Ultramicroscopy , vol.64 , pp. 49-55
    • van Zwet, E.J.1    Zandberge, H.W.2
  • 6
    • 0032190811 scopus 로고    scopus 로고
    • The effects of electron and photon scattering on signal and noise transfer properties of scintillators in CCD cameras used for electron detection
    • Meyer R R and Kirkland A (1998) The effects of electron and photon scattering on signal and noise transfer properties of scintillators in CCD cameras used for electron detection. Ultramicroscopy 75: 23-33.
    • (1998) Ultramicroscopy , vol.75 , pp. 23-33
    • Meyer, R.R.1    Kirkland, A.2
  • 7
    • 0033793451 scopus 로고    scopus 로고
    • CCD detectors in high-resolution biological electron microscopy
    • Faruqi A R and Subramaniam S (2000) CCD detectors in high-resolution biological electron microscopy. Q. Rev. Biophys. 33: 1-27.
    • (2000) Q. Rev. Biophys , vol.33 , pp. 1-27
    • Faruqi, A.R.1    Subramaniam, S.2
  • 9
    • 0024640511 scopus 로고
    • Optimization of imaging energy filters for high-resolution analytical electron microscopy
    • Rose H (1989) Optimization of imaging energy filters for high-resolution analytical electron microscopy. Ultramicroscopy 28: 184-189.
    • (1989) Ultramicroscopy , vol.28 , pp. 184-189
    • Rose, H.1
  • 11
    • 14844330221 scopus 로고    scopus 로고
    • Structural studies by electron tomography: From cells to molecules
    • Lucic V, Forster F, and Baumeister W (2005) Structural studies by electron tomography: from cells to molecules. Annu. Rev. Biochem. 74: 833-865.
    • (2005) Annu. Rev. Biochem , vol.74 , pp. 833-865
    • Lucic, V.1    Forster, F.2    Baumeister, W.3
  • 12
    • 20544469627 scopus 로고    scopus 로고
    • Advantages of CCD detectors for de novo three-dimensional structure determination in single-particle electron microscopy
    • Sander B, Golas M M, and Stark H (2005) Advantages of CCD detectors for de novo three-dimensional structure determination in single-particle electron microscopy. J. Struct. Biol. 151: 92-105.
    • (2005) J. Struct. Biol , vol.151 , pp. 92-105
    • Sander, B.1    Golas, M.M.2    Stark, H.3
  • 13
    • 0008230543 scopus 로고
    • CsI(Na) scintillation plate with high spatial resolution
    • Oba K, Ito M, and Yamaguchi M, Tanaka, M. (1988) CsI(Na) scintillation plate with high spatial resolution. Adv. Electron El. Phys. 74: 247-255.
    • (1988) Adv. Electron El. Phys , vol.74 , pp. 247-255
    • Oba, K.1    Ito, M.2    Yamaguchi, M.3    Tanaka, M.4
  • 16
    • 0025292355 scopus 로고
    • Model for the structure of bacteriorhodopsin based on high-resolution electron cryo-microscopy
    • Henderson R, Baldwin J M, Ceska T A, Zemlin F, Beckmann E, and Dowing K H (1990) Model for the structure of bacteriorhodopsin based on high-resolution electron cryo-microscopy. J. Mol. Biol. 213: 899-929.
    • (1990) J. Mol. Biol , vol.213 , pp. 899-929
    • Henderson, R.1    Baldwin, J.M.2    Ceska, T.A.3    Zemlin, F.4    Beckmann, E.5    Dowing, K.H.6
  • 17
    • 0029881549 scopus 로고    scopus 로고
    • Extensible and object-oriented system Eos supplies a new environment for image analysis of electron micrographs of macromolecules
    • Yasunaga T and Wakabayashi T (1996) Extensible and object-oriented system Eos supplies a new environment for image analysis of electron micrographs of macromolecules. J. Struct. Biol. 116: 155-160.
    • (1996) J. Struct. Biol , vol.116 , pp. 155-160
    • Yasunaga, T.1    Wakabayashi, T.2
  • 18
    • 0030292247 scopus 로고    scopus 로고
    • Optimization of thin-foil based phosphor screens for CCD imaging in TEM in the voltage range of 80-400 kV
    • Fan G Y and Ellisman M H (1996) Optimization of thin-foil based phosphor screens for CCD imaging in TEM in the voltage range of 80-400 kV. Ultramicroscopy 66: 11-19.
    • (1996) Ultramicroscopy , vol.66 , pp. 11-19
    • Fan, G.Y.1    Ellisman, M.H.2
  • 19
    • 0030291911 scopus 로고    scopus 로고
    • Electron detection characteristics of slow-scan CCD camera
    • Zuo J M (1996) Electron detection characteristics of slow-scan CCD camera. Ultramicroscopy 66: 21-33.
    • (1996) Ultramicroscopy , vol.66 , pp. 21-33
    • Zuo, J.M.1
  • 20
    • 0034193465 scopus 로고    scopus 로고
    • Characterization of the signal and noise transfer of CCD cameras for electron detection
    • Meyer R R and Kerkland A I (2000) Characterization of the signal and noise transfer of CCD cameras for electron detection. Microsc. Res. Tech. 49: 269-280.
    • (2000) Microsc. Res. Tech , vol.49 , pp. 269-280
    • Meyer, R.R.1    Kerkland, A.I.2
  • 21
    • 20444450897 scopus 로고    scopus 로고
    • Noiseless direct detection of electrons in Medipix2 for electron microscopy
    • Faruqi A R, Henderson R, and Tlustos L (2005) Noiseless direct detection of electrons in Medipix2 for electron microscopy. Nucl. Instr. Methods A 546: 160-163.
    • (2005) Nucl. Instr. Methods A , vol.546 , pp. 160-163
    • Faruqi, A.R.1    Henderson, R.2    Tlustos, L.3
  • 22
    • 33847667600 scopus 로고    scopus 로고
    • Direct electron detectors for electron microscopy
    • Faruqi A R (2007) Direct electron detectors for electron microscopy. Adv. Imaging Electron Phys. 145: 55-93.
    • (2007) Adv. Imaging Electron Phys , vol.145 , pp. 55-93
    • Faruqi, A.R.1
  • 24
    • 34247145420 scopus 로고    scopus 로고
    • Direct electron imaging in electron microscopy with monolithic active pixel sensors
    • Deptuch G, Besson A, Rehak P, Szelezniak M, Winter M, and Zhu Y (2007) Direct electron imaging in electron microscopy with monolithic active pixel sensors. Ultramicroscopy 107: 674-684.
    • (2007) Ultramicroscopy , vol.107 , pp. 674-684
    • Deptuch, G.1    Besson, A.2    Rehak, P.3    Szelezniak, M.4    Winter, M.5    Zhu, Y.6
  • 25
    • 0039507411 scopus 로고
    • Structure of purple membrane from halobacterium halobium: Recording, measurement and evaluation of electron micrographs at 3.5 Å resolution
    • Henderson R, Baldwin J M, Downing K H, Lepault J, and Zemlin F (1986) Structure of purple membrane from halobacterium halobium: recording, measurement and evaluation of electron micrographs at 3.5 Å resolution. Ultramicroscopy 19: 147-178.
    • (1986) Ultramicroscopy , vol.19 , pp. 147-178
    • Henderson, R.1    Baldwin, J.M.2    Downing, K.H.3    Lepault, J.4    Zemlin, F.5
  • 26
    • 0036229990 scopus 로고    scopus 로고
    • Quantitative comparison of zero-loss and conventional electron diffraction from two-dimensional and thin three-dimensional protein crystals
    • Yonekura K, Maki S, and Namba K (2002) Quantitative comparison of zero-loss and conventional electron diffraction from two-dimensional and thin three-dimensional protein crystals. Biophys. J. 82: 2784-2797.
    • (2002) Biophys. J , vol.82 , pp. 2784-2797
    • Yonekura, K.1    Maki, S.2    Namba, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.