메뉴 건너뛰기




Volumn 90, Issue 5, 2008, Pages 570-573

A ten-year follow-up of the Reflection cementless acetabular component

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; COHORT ANALYSIS; FEMALE; FOLLOW UP; HUMAN; KAPLAN MEIER METHOD; MAJOR CLINICAL STUDY; MALE; OSTEOLYSIS; PAIN; PRIORITY JOURNAL; PROSTHESIS FAILURE; PROSTHESIS FIXATION; PROSTHESIS LOOSENING; RANGE OF MOTION; REVIEW; SURVIVAL; TOTAL HIP PROSTHESIS; WALKING;

EID: 43649101430     PISSN: 0301620X     EISSN: None     Source Type: Journal    
DOI: 10.1302/0301-620X.90B5.20116     Document Type: Review
Times cited : (15)

References (32)
  • 1
    • 0028845162 scopus 로고
    • The impact of modularity in total hip arthroplasty
    • Chmell MJ, Rispler D, Poss R. The impact of modularity in total hip arthroplasty. Clin Orthop 1995;319:77-84.
    • (1995) Clin Orthop , vol.319 , pp. 77-84
    • Chmell, M.J.1    Rispler, D.2    Poss, R.3
  • 2
    • 0344198088 scopus 로고    scopus 로고
    • Results of uncemented cups: A critical appraisal at 15 years
    • Harris WH. Results of uncemented cups: a critical appraisal at 15 years. Clin Orthop 2003;417:121-5.
    • (2003) Clin Orthop , vol.417 , pp. 121-125
    • Harris, W.H.1
  • 4
    • 0028197478 scopus 로고
    • Severe polyethylene wear in total hip arthroplasty: Observations from retrieved AML PLUS hip implants with an ACS polyethylene liner
    • Bono JV, Sanford L, Toussaint JT. Severe polyethylene wear in total hip arthroplasty: observations from retrieved AML PLUS hip implants with an ACS polyethylene liner. J Arthroplasty 1994;9:119-25.
    • (1994) J Arthroplasty , vol.9 , pp. 119-125
    • Bono, J.V.1    Sanford, L.2    Toussaint, J.T.3
  • 5
    • 0035217507 scopus 로고    scopus 로고
    • Pattern of osteolysis around two different cementless metal-backed cups: Retrospective, radiographic analysis at minimum 10-year follow-up
    • Claus AM, Sychterz CJ, Hopper RH Jr, Engh CA. Pattern of osteolysis around two different cementless metal-backed cups: retrospective, radiographic analysis at minimum 10-year follow-up. J Arthroplasty 2001;16:177-82.
    • (2001) J Arthroplasty , vol.16 , pp. 177-182
    • Claus, A.M.1    Sychterz, C.J.2    Hopper Jr, R.H.3    Engh, C.A.4
  • 6
    • 0033869250 scopus 로고    scopus 로고
    • Characterization of long-term femoral-head-penetration rates: Association with and prediction of osteolysis
    • Dowd JE, Sychterz CJ, Young AM, Engh CA. Characterization of long-term femoral-head-penetration rates: association with and prediction of osteolysis. J Bone Joint Surg [Am] 2000;82-A:1102-7.
    • (2000) J Bone Joint Surg [Am] , vol.82-A , pp. 1102-1107
    • Dowd, J.E.1    Sychterz, C.J.2    Young, A.M.3    Engh, C.A.4
  • 7
    • 0036563404 scopus 로고    scopus 로고
    • Survival and polyethylene wear of porous-coated acetabular components in patients less than fifty years old: Results at nine to fourteen years
    • Crowther JD, Lachiewicz PF. Survival and polyethylene wear of porous-coated acetabular components in patients less than fifty years old: results at nine to fourteen years. J Bone Joint Surg [Am] 2002;84-A:729-35.
    • (2002) J Bone Joint Surg [Am] , vol.84-A , pp. 729-735
    • Crowther, J.D.1    Lachiewicz, P.F.2
  • 8
    • 0034089792 scopus 로고    scopus 로고
    • Clinical and radiographic evaluation of the Harris-Galante cup: Incidence of wear and osteolysis at 7 to 9 years followup
    • Soto MO, Rodriguez JA, Ranawat CS. Clinical and radiographic evaluation of the Harris-Galante cup: incidence of wear and osteolysis at 7 to 9 years followup. J Arthroplasty 2000;15:139-45.
    • (2000) J Arthroplasty , vol.15 , pp. 139-145
    • Soto, M.O.1    Rodriguez, J.A.2    Ranawat, C.S.3
  • 9
    • 0028245867 scopus 로고
    • Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components
    • Huk OL, Bansal M, Betts F, et al. Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components. J Bone Joint Surg [Br] 1994;76-B:568-74.
    • (1994) J Bone Joint Surg [Br] , vol.76-B , pp. 568-574
    • Huk, O.L.1    Bansal, M.2    Betts, F.3
  • 10
    • 0029829977 scopus 로고    scopus 로고
    • Wear of the polyethylene liner-metallic shell interface in modular acetabular components: An in vitro analysis
    • Lieberman JR, Kay RM, Hamlet WP, Park SH, Kabo JM. Wear of the polyethylene liner-metallic shell interface in modular acetabular components: an in vitro analysis. J Arthroplasty 1996;11:602-8.
    • (1996) J Arthroplasty , vol.11 , pp. 602-608
    • Lieberman, J.R.1    Kay, R.M.2    Hamlet, W.P.3    Park, S.H.4    Kabo, J.M.5
  • 11
    • 0032843180 scopus 로고    scopus 로고
    • Ultra-high-molecular weight polyethylene wear: An in vitro comparison of acetabular metal types and polished surfaces
    • Shepard MF, Lieberman JR, Kabo JM. Ultra-high-molecular weight polyethylene wear: an in vitro comparison of acetabular metal types and polished surfaces. J Arthroplasty 1999;14:860-6.
    • (1999) J Arthroplasty , vol.14 , pp. 860-866
    • Shepard, M.F.1    Lieberman, J.R.2    Kabo, J.M.3
  • 12
    • 0032071068 scopus 로고    scopus 로고
    • Backside nonconformity and locking restraints affect liner/shell load transfer mechanisms and relative motion in modular acetabular components for total hip replacement
    • Kurtz SM, Ochoa JA, White CV, Srivastav S, Cournoyer J. Backside nonconformity and locking restraints affect liner/shell load transfer mechanisms and relative motion in modular acetabular components for total hip replacement. J Biomech 1998;31:431-7.
    • (1998) J Biomech , vol.31 , pp. 431-437
    • Kurtz, S.M.1    Ochoa, J.A.2    White, C.V.3    Srivastav, S.4    Cournoyer, J.5
  • 13
    • 0027380702 scopus 로고
    • A comparison of the disassociation strength of modular acetabular components
    • Tradonsky S, Postak PD, Froimson AI, Greenwald AS. A comparison of the disassociation strength of modular acetabular components. Clin Orthop 1993;296:154-60.
    • (1993) Clin Orthop , vol.296 , pp. 154-160
    • Tradonsky, S.1    Postak, P.D.2    Froimson, A.I.3    Greenwald, A.S.4
  • 14
    • 0032801070 scopus 로고    scopus 로고
    • Simulation of initial frontside and backside wear rates in a modular acetabular component with multiple screw holes
    • Kurtz SM, Ochoa JA, Hovey CB, White CV. Simulation of initial frontside and backside wear rates in a modular acetabular component with multiple screw holes. J Biomech 1999;32:967-76.
    • (1999) J Biomech , vol.32 , pp. 967-976
    • Kurtz, S.M.1    Ochoa, J.A.2    Hovey, C.B.3    White, C.V.4
  • 15
    • 0024441094 scopus 로고
    • Evaluation of cementless acetabular component migration: An experimental study
    • Massin P, Schmidt L, Engh CA. Evaluation of cementless acetabular component migration: an experimental study. J Arthroplasty 1989;4:245-51.
    • (1989) J Arthroplasty , vol.4 , pp. 245-251
    • Massin, P.1    Schmidt, L.2    Engh, C.A.3
  • 16
    • 0017047304 scopus 로고
    • Radiological demarcation of cemented sockets in total hip replacement
    • DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop 1976;121:20-32.
    • (1976) Clin Orthop , vol.121 , pp. 20-32
    • DeLee, J.G.1    Charnley, J.2
  • 19
    • 0032741236 scopus 로고    scopus 로고
    • Motion at the modular acetabular shell and liner interface: A comparative study
    • Fehring TK, Smith SE, Braun ER, et al. Motion at the modular acetabular shell and liner interface: a comparative study. Clin Orthop 1999;367:306-14.
    • (1999) Clin Orthop , vol.367 , pp. 306-314
    • Fehring, T.K.1    Smith, S.E.2    Braun, E.R.3
  • 21
    • 26844522305 scopus 로고    scopus 로고
    • The acetabular insert-metal backing interface: An additional source of polyethylene wear debris
    • Wasielewski RC, Jacobs JJ, Arthurs B, Rubash HE. The acetabular insert-metal backing interface: an additional source of polyethylene wear debris. J Arthroplasty 2005;20:914-22.
    • (2005) J Arthroplasty , vol.20 , pp. 914-922
    • Wasielewski, R.C.1    Jacobs, J.J.2    Arthurs, B.3    Rubash, H.E.4
  • 23
    • 0031059184 scopus 로고    scopus 로고
    • Fixation of ultrahigh molecular-weight polyethylene liners to metal-backed acetabular cups
    • Williams VG 2nd, Whiteside LA, White SE, McCarthy DS. Fixation of ultrahigh molecular-weight polyethylene liners to metal-backed acetabular cups. J Arthroplasty 1997;12:25-31.
    • (1997) J Arthroplasty , vol.12 , pp. 25-31
    • Williams 2nd, V.G.1    Whiteside, L.A.2    White, S.E.3    McCarthy, D.S.4
  • 24
    • 27644475315 scopus 로고    scopus 로고
    • Backside wear is low in retrieved modern, modular, and nonmodular acetabular liners
    • Della Valle AG, Rana A, Furman B, Sculco TP, Salvati EA. Backside wear is low in retrieved modern, modular, and nonmodular acetabular liners. Clin Orthop 2005;440:184-91.
    • (2005) Clin Orthop , vol.440 , pp. 184-191
    • Della Valle, A.G.1    Rana, A.2    Furman, B.3    Sculco, T.P.4    Salvati, E.A.5
  • 25
    • 4544290225 scopus 로고    scopus 로고
    • Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty
    • Della Valle AG, Zoppi A, Peterson MGE, Salvati EA. Clinical and radiographic results associated with a modern, cementless modular cup design in total hip arthroplasty. J Bone Joint Surg [Am] 2004;86-A:1998-2003.
    • (2004) J Bone Joint Surg [Am] , vol.86-A , pp. 1998-2003
    • Della Valle, A.G.1    Zoppi, A.2    Peterson, M.G.E.3    Salvati, E.A.4
  • 26
    • 16644375334 scopus 로고    scopus 로고
    • Wear and periprosthetic osteolysis in a match-paired study of modular and nonmodular uncemented acetabular cups
    • Della Valle AG, Su E, Zoppi A, Sculco TP, Salvati EA. Wear and periprosthetic osteolysis in a match-paired study of modular and nonmodular uncemented acetabular cups. J Arthroplasty 2004;19:972-7.
    • (2004) J Arthroplasty , vol.19 , pp. 972-977
    • Della Valle, A.G.1    Su, E.2    Zoppi, A.3    Sculco, T.P.4    Salvati, E.A.5
  • 27
    • 33749449807 scopus 로고    scopus 로고
    • Second-generation porous-coated cementless total hip arthroplasties have high survival
    • Chen CJ, Zenos JS, McAuley JP, Young A, Engh CA Sr. Second-generation porous-coated cementless total hip arthroplasties have high survival. Clin Orthop 2006;451:121-7.
    • (2006) Clin Orthop , vol.451 , pp. 121-127
    • Chen, C.J.1    Zenos, J.S.2    McAuley, J.P.3    Young, A.4    Engh Sr., C.A.5
  • 28
    • 33845434178 scopus 로고    scopus 로고
    • The value of anteroposterior pelvic radiographs for evaluating pelvic osteolysis
    • Kitamura N, Pappedemos PC, Duffy PR 3rd, et al. The value of anteroposterior pelvic radiographs for evaluating pelvic osteolysis. Clin Orthop 2006;453:239-45.
    • (2006) Clin Orthop , vol.453 , pp. 239-245
    • Kitamura, N.1    Pappedemos, P.C.2    Duffy 3rd, P.R.3
  • 29
    • 0031018638 scopus 로고    scopus 로고
    • Primary total hip arthroplasty with a porous-coated acetabular component: Seven-to-ten-year results
    • Tompkins GS, Jacobs JJ, Kull LR, Rosenberg AG, Galante JO. Primary total hip arthroplasty with a porous-coated acetabular component: seven-to-ten-year results. J Bone Joint Surg [Am] 1997;79-A:169-76.
    • (1997) J Bone Joint Surg [Am] , vol.79-A , pp. 169-176
    • Tompkins, G.S.1    Jacobs, J.J.2    Kull, L.R.3    Rosenberg, A.G.4    Galante, J.O.5
  • 30
    • 0033009808 scopus 로고    scopus 로고
    • Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement: An average ten-year follow-up study
    • Clohisy JC, Harris WH. Primary hybrid total hip replacement, performed with insertion of the acetabular component without cement and a precoat femoral component with cement: an average ten-year follow-up study. J Bone Joint Surg [Am] 1999;81-A:247-55.
    • (1999) J Bone Joint Surg [Am] , vol.81-A , pp. 247-255
    • Clohisy, J.C.1    Harris, W.H.2
  • 31
    • 0036633022 scopus 로고    scopus 로고
    • Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws: Average ten-year follow-up
    • Udomkiat P, Dorr LD, Wan Z. Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws: average ten-year follow-up. J Bone Joint Surg [Am] 2002;84-A:1195-200.
    • (2002) J Bone Joint Surg [Am] , vol.84-A , pp. 1195-1200
    • Udomkiat, P.1    Dorr, L.D.2    Wan, Z.3
  • 32
    • 0942301374 scopus 로고    scopus 로고
    • Cementless acetabular fixation at fifteen years: A comparison with the same surgeon's results following acetabular fixation with cement
    • Gaffey JL, Callaghan JJ, Pedersen DR, et al. Cementless acetabular fixation at fifteen years: a comparison with the same surgeon's results following acetabular fixation with cement. J Bone Joint Surg [Am] 2004;86-A:257-61.
    • (2004) J Bone Joint Surg [Am] , vol.86-A , pp. 257-261
    • Gaffey, J.L.1    Callaghan, J.J.2    Pedersen, D.R.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.