메뉴 건너뛰기




Volumn 90, Issue 5, 2008, Pages 556-561

The creep and wear of highly cross-linked polyethylene: A three-year randomised, controlled trial using radiostereometric analysis

Author keywords

[No Author keywords available]

Indexed keywords

CROSS LINKING REAGENT; POLYETHYLENE;

EID: 43649089638     PISSN: 0301620X     EISSN: None     Source Type: Journal    
DOI: 10.1302/0301-620X.90B5.20545     Document Type: Article
Times cited : (126)

References (42)
  • 3
    • 0032786064 scopus 로고    scopus 로고
    • Fixation, polyethylene wear, and pelvic osteolysis in primary total hip replacement
    • Maloney WJ, Galante JO, Anderson M, et al. Fixation, polyethylene wear, and pelvic osteolysis in primary total hip replacement. Clin Orthop 1999;369:157-64.
    • (1999) Clin Orthop , vol.369 , pp. 157-164
    • Maloney, W.J.1    Galante, J.O.2    Anderson, M.3
  • 4
    • 0345168808 scopus 로고    scopus 로고
    • The nature and dissemination of UHMWPE wear debris retrieved from periprosthetic tissue of THR
    • Elfick AP, Green SM, Krikler S, Unsworth A. The nature and dissemination of UHMWPE wear debris retrieved from periprosthetic tissue of THR. J Biomed Mater Res A 2003;65:95-108.
    • (2003) J Biomed Mater Res A , vol.65 , pp. 95-108
    • Elfick, A.P.1    Green, S.M.2    Krikler, S.3    Unsworth, A.4
  • 5
    • 0032804049 scopus 로고    scopus 로고
    • Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls
    • McKellop H, Shen FW, DiMaio W, Lancaster JG. Wear of gamma-crosslinked polyethylene acetabular cups against roughened femoral balls. Clin Orthop 1999;369:73-82.
    • (1999) Clin Orthop , vol.369 , pp. 73-82
    • McKellop, H.1    Shen, F.W.2    DiMaio, W.3    Lancaster, J.G.4
  • 6
    • 0035117295 scopus 로고    scopus 로고
    • A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties
    • Muratoglu OK, Bragdon CR, O'Connor DO, Jasty M, Harris WH. A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. J Arthroplasty 2001;16:149-60.
    • (2001) J Arthroplasty , vol.16 , pp. 149-160
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.O.3    Jasty, M.4    Harris, W.H.5
  • 7
    • 0032775639 scopus 로고    scopus 로고
    • Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty
    • Kurtz SM, Muratoglu OK, Evans M, Edidin AA. Advances in the processing, sterilization, and crosslinking of ultra-high molecular weight polyethylene for total joint arthroplasty. Biomaterials 1999;20:1659-88.
    • (1999) Biomaterials , vol.20 , pp. 1659-1688
    • Kurtz, S.M.1    Muratoglu, O.K.2    Evans, M.3    Edidin, A.A.4
  • 8
    • 0035217958 scopus 로고    scopus 로고
    • Study of retrieved acetabular sockets made from high-dose, cross-linked polyethylene
    • Oonishi H, Clarke IC, Masuda S, Amino H. Study of retrieved acetabular sockets made from high-dose, cross-linked polyethylene. J Arthroplasty 2001;16:129-33.
    • (2001) J Arthroplasty , vol.16 , pp. 129-133
    • Oonishi, H.1    Clarke, I.C.2    Masuda, S.3    Amino, H.4
  • 9
    • 0033922311 scopus 로고    scopus 로고
    • Wear of high-dose gamma-irradiated polyethylene in total hip replacements
    • Oonishi H, Kadoya Y. Wear of high-dose gamma-irradiated polyethylene in total hip replacements. J Orthop Sci 2000;5:223-8.
    • (2000) J Orthop Sci , vol.5 , pp. 223-228
    • Oonishi, H.1    Kadoya, Y.2
  • 11
    • 2642564678 scopus 로고    scopus 로고
    • Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners
    • Bradford L, Baker DA, Graham J, et al. Wear and surface cracking in early retrieved highly cross-linked polyethylene acetabular liners. J Bone Joint Surg [Am] 2004;86-A:1271-82.
    • (2004) J Bone Joint Surg [Am] , vol.86-A , pp. 1271-1282
    • Bradford, L.1    Baker, D.A.2    Graham, J.3
  • 12
    • 0344629811 scopus 로고    scopus 로고
    • Highly cross-linked polyethylene in cemented THA: Randomized study of 61 hips
    • Digas G, Kärrholm J, Thanner J, Malchau H, Herberts P. Highly cross-linked polyethylene in cemented THA: randomized study of 61 hips. Clin Orthop 2003;417:126-38.
    • (2003) Clin Orthop , vol.417 , pp. 126-138
    • Digas, G.1    Kärrholm, J.2    Thanner, J.3    Malchau, H.4    Herberts, P.5
  • 13
    • 9644254123 scopus 로고    scopus 로고
    • Highly cross-linked polyethylene in total hip arthroplasty: Randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis
    • Digas G, Kärrholm J, Thanner J, Malchau H, Herberts P. Highly cross-linked polyethylene in total hip arthroplasty: randomized evaluation of penetration rate in cemented and uncemented sockets using radiostereometric analysis. Clin Orthop 2004;429:6-16.
    • (2004) Clin Orthop , vol.429 , pp. 6-16
    • Digas, G.1    Kärrholm, J.2    Thanner, J.3    Malchau, H.4    Herberts, P.5
  • 14
    • 14844312072 scopus 로고    scopus 로고
    • The measurement of creep in ultra-high molecular weight polyethylene: A comparison of conventional versus highly cross-linked polyethylene
    • Estok DM 2nd, Bragdon CR, Plank GR, et al. The measurement of creep in ultra-high molecular weight polyethylene: a comparison of conventional versus highly cross-linked polyethylene. J Arthroplasty 2005;20:239-43.
    • (2005) J Arthroplasty , vol.20 , pp. 239-243
    • Estok 2nd, D.M.1    Bragdon, C.R.2    Plank, G.R.3
  • 15
    • 0034880751 scopus 로고    scopus 로고
    • The effect of activity levels of total hip arthroplasty patients on socket penetration
    • Goldsmith AA, Dowson D, Wroblewski BM, et al. The effect of activity levels of total hip arthroplasty patients on socket penetration. J Arthroplasty 2001;16:620-7.
    • (2001) J Arthroplasty , vol.16 , pp. 620-627
    • Goldsmith, A.A.1    Dowson, D.2    Wroblewski, B.M.3
  • 17
    • 33746056145 scopus 로고    scopus 로고
    • Large diameter femoral heads on highly cross-linked polyethylene: Minimum 3-year results
    • Geller JA, Malchau H, Bragdon C, et al. Large diameter femoral heads on highly cross-linked polyethylene: minimum 3-year results. Clin Orthop 2006;447:53-9.
    • (2006) Clin Orthop , vol.447 , pp. 53-59
    • Geller, J.A.1    Malchau, H.2    Bragdon, C.3
  • 18
    • 0141993638 scopus 로고    scopus 로고
    • Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: A randomized prospective trial
    • Martell JM, Verner JJ, Incavo SJ. Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: a randomized prospective trial. J Arthroplasty 2003;18:55-9.
    • (2003) J Arthroplasty , vol.18 , pp. 55-59
    • Martell, J.M.1    Verner, J.J.2    Incavo, S.J.3
  • 19
    • 0030669292 scopus 로고    scopus 로고
    • Determination of polyethylene wear in total hip replacements with use of digital radiographs
    • Martell JM, Berdia S. Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg [Am] 1997;79-A:1635-41.
    • (1997) J Bone Joint Surg [Am] , vol.79-A , pp. 1635-1641
    • Martell, J.M.1    Berdia, S.2
  • 20
    • 0033029624 scopus 로고    scopus 로고
    • Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty
    • Sochart DH. Relationship of acetabular wear to osteolysis and loosening in total hip arthroplasty. Clin Orthop 1999;363:135-50.
    • (1999) Clin Orthop , vol.363 , pp. 135-150
    • Sochart, D.H.1
  • 21
    • 43649088849 scopus 로고    scopus 로고
    • No authors listed. http://www.zimmer.com/z/ctl/global/action/1/id/ 1461/template/pc/prcat/p2/prod/y (date last accessed 10 December 2007).
    • No authors listed. http://www.zimmer.com/z/ctl/global/action/1/id/ 1461/template/pc/prcat/p2/prod/y (date last accessed 10 December 2007).
  • 22
    • 40749130415 scopus 로고    scopus 로고
    • Does highly cross linked polyethylene wear less than conventional polyethylene in total hip arthroplasty?: A double blind randomised controlled trial using RSA
    • in press
    • Glyn-Jones S, Isaac S, Hauptfleisch J, et al. Does highly cross linked polyethylene wear less than conventional polyethylene in total hip arthroplasty?: a double blind randomised controlled trial using RSA. J Arthroplasty 2008; in press.
    • (2008) J Arthroplasty
    • Glyn-Jones, S.1    Isaac, S.2    Hauptfleisch, J.3
  • 23
    • 43649094518 scopus 로고    scopus 로고
    • Evans S, Royston P, Day S. Minim: allocation by minimisation in clinical trials. http://www-users.york.ac.uk/~mb55/guide/minim.htm (date last accessed 23 May 2003).
    • Evans S, Royston P, Day S. Minim: allocation by minimisation in clinical trials. http://www-users.york.ac.uk/~mb55/guide/minim.htm (date last accessed 23 May 2003).
  • 24
    • 0034886433 scopus 로고    scopus 로고
    • Should total hip arthroplasty femoral components be designed to subside: A radiostereometric analysis study of the Charnley Elite and Exeter stems
    • Alfaro-Adrián J, Gill HS, Murray DW. Should total hip arthroplasty femoral components be designed to subside: a radiostereometric analysis study of the Charnley Elite and Exeter stems. J Arthroplasty 2001;16:598-606.
    • (2001) J Arthroplasty , vol.16 , pp. 598-606
    • Alfaro-Adrián, J.1    Gill, H.S.2    Murray, D.W.3
  • 26
    • 0032843180 scopus 로고    scopus 로고
    • Ultra-high-molecular weight polyethylene wear: An in vitro comparison of acetabular metal types and polished surfaces
    • Shepard MF, Lieberman JR, Kabo JM. Ultra-high-molecular weight polyethylene wear: an in vitro comparison of acetabular metal types and polished surfaces. J Arthroplasty 1999;14:860-6.
    • (1999) J Arthroplasty , vol.14 , pp. 860-866
    • Shepard, M.F.1    Lieberman, J.R.2    Kabo, J.M.3
  • 28
    • 0022219799 scopus 로고
    • Direction and rate of socket wear in Charnley low-friction arthroplasty
    • Wroblewski BM. Direction and rate of socket wear in Charnley low-friction arthroplasty. J Bone Joint Surg [Br] 1985;67-B:757-61.
    • (1985) J Bone Joint Surg [Br] , vol.67-B , pp. 757-761
    • Wroblewski, B.M.1
  • 30
    • 0033388578 scopus 로고    scopus 로고
    • Multidirectional deformation in fully congruent acetabular components
    • Akisue T, Bauer TW, Yamaguchi M, et al. Multidirectional deformation in fully congruent acetabular components. J Arthroplasty 1999;14:1011-18.
    • (1999) J Arthroplasty , vol.14 , pp. 1011-1018
    • Akisue, T.1    Bauer, T.W.2    Yamaguchi, M.3
  • 31
    • 0030331025 scopus 로고    scopus 로고
    • An investigation into the origins of time-dependent variation in penetration rates with Charnley acetabular cups: Wear, creep or degradation?
    • Isaac GH, Dowson D, Wroblewski BM. An investigation into the origins of time-dependent variation in penetration rates with Charnley acetabular cups: wear, creep or degradation? Proc Inst Mech Eng [H] 1996;210:209-16.
    • (1996) Proc Inst Mech Eng [H] , vol.210 , pp. 209-216
    • Isaac, G.H.1    Dowson, D.2    Wroblewski, B.M.3
  • 33
    • 0035217940 scopus 로고    scopus 로고
    • Large diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: A new concept
    • Muratoglu OK, Bragdon CR, O'Connor D, et al. Large diameter femoral heads used in conjunction with a highly cross-linked ultra-high molecular weight polyethylene: a new concept. J Arthroplasty 2001;16(Suppl 1):24-30.
    • (2001) J Arthroplasty , vol.16 , Issue.SUPPL. 1 , pp. 24-30
    • Muratoglu, O.K.1    Bragdon, C.R.2    O'Connor, D.3
  • 35
    • 0031811155 scopus 로고    scopus 로고
    • Early osteolysis with Hylamer acetabular liners
    • Graeter JH, Nevins R. Early osteolysis with Hylamer acetabular liners. J Arthroplasty 1998;13:464-6.
    • (1998) J Arthroplasty , vol.13 , pp. 464-466
    • Graeter, J.H.1    Nevins, R.2
  • 36
    • 26844448524 scopus 로고    scopus 로고
    • In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty
    • Manning DW, Chiang PP, Martell JM, Galante JO, Harris WH. In vivo comparative wear study of traditional and highly cross-linked polyethylene in total hip arthroplasty. J Arthroplasty 2005;20:880-6.
    • (2005) J Arthroplasty , vol.20 , pp. 880-886
    • Manning, D.W.1    Chiang, P.P.2    Martell, J.M.3    Galante, J.O.4    Harris, W.H.5
  • 37
    • 33747887186 scopus 로고    scopus 로고
    • A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked marathon and non-cross-linked Enduron polyethylene liners
    • Engh CA Jr, Stepniewski AS, Ginn SD, et al. A randomized prospective evaluation of outcomes after total hip arthroplasty using cross-linked marathon and non-cross-linked Enduron polyethylene liners. J Arthroplasty 2006;21:17-25.
    • (2006) J Arthroplasty , vol.21 , pp. 17-25
    • Engh Jr, C.A.1    Stepniewski, A.S.2    Ginn, S.D.3
  • 38
    • 0038351040 scopus 로고    scopus 로고
    • Comparison of two and three-dimensional computerized polyethylene wear analysis after total hip arthroplasty
    • Martell JM, Berkson E, Berger R, Jacobs J. Comparison of two and three-dimensional computerized polyethylene wear analysis after total hip arthroplasty. J Bone Joint Surg [Am] 2003;85-A:1111-17.
    • (2003) J Bone Joint Surg [Am] , vol.85-A , pp. 1111-1117
    • Martell, J.M.1    Berkson, E.2    Berger, R.3    Jacobs, J.4
  • 39
    • 0141447819 scopus 로고    scopus 로고
    • The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene
    • Baker DA, Bellare A, Pruitt L. The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene. J Biomed Mater Res A 2003;66:146-54.
    • (2003) J Biomed Mater Res A , vol.66 , pp. 146-154
    • Baker, D.A.1    Bellare, A.2    Pruitt, L.3
  • 40
    • 0033567865 scopus 로고    scopus 로고
    • Study of fatigue resistance of chemical and radiation crosslinked medical grade ultrahigh molecular weight polyethylene
    • Baker DA, Hastings RS, Pruitt L. Study of fatigue resistance of chemical and radiation crosslinked medical grade ultrahigh molecular weight polyethylene. J Biomed Mater Res 1999;46:573-81.
    • (1999) J Biomed Mater Res , vol.46 , pp. 573-581
    • Baker, D.A.1    Hastings, R.S.2    Pruitt, L.3
  • 41
    • 0035124730 scopus 로고    scopus 로고
    • Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene
    • Endo MM, Barbour PS, Barton DC, et al. Comparative wear and wear debris under three different counterface conditions of crosslinked and non-crosslinked ultra high molecular weight polyethylene. Biomed Mater Eng 2001;11:23-35.
    • (2001) Biomed Mater Eng , vol.11 , pp. 23-35
    • Endo, M.M.1    Barbour, P.S.2    Barton, D.C.3
  • 42
    • 8644239396 scopus 로고    scopus 로고
    • Wear, debris, and biologic activity of cross-linked polyethylene in the knee: Benefits and potential concerns
    • Fisher J, McEwen HM, Tipper JL, et al. Wear, debris, and biologic activity of cross-linked polyethylene in the knee: benefits and potential concerns. Clin Orthop 2004;428:114-19.
    • (2004) Clin Orthop , vol.428 , pp. 114-119
    • Fisher, J.1    McEwen, H.M.2    Tipper, J.L.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.