Polyethylene debris-induced osteolysis and loosening in uncemented total hip arthroplasty: A cause of late failure
-
Cooper RA, McAllister CM, Borden LS, et al: Polyethylene debris-induced osteolysis and loosening in uncemented total hip arthroplasty: a cause of late failure. J Arthroplasty 7:285, 1992
-
(1992)
J Arthroplasty
, vol.7
, pp. 285
-
-
Cooper, R.A.1
McAllister, C.M.2
Borden, L.S.3
-
2
-
-
0026550544
-
The mechanism of loosening of cemented acetabular components in total hip arthroplasty: Analysis of specimens retrieved at autopsy
-
Schmalzried TP, Kwong LM, Jasty M, et al: The mechanism of loosening of cemented acetabular components in total hip arthroplasty: analysis of specimens retrieved at autopsy. Clin Orthop 274:60, 1992
-
(1992)
Clin Orthop
, vol.274
, pp. 60
-
-
Schmalzried, T.P.1
Kwong, L.M.2
Jasty, M.3
-
3
-
-
0022219799
-
Direction and rate of socket wear in Charnley low-friction arthroplasty
-
Wroblewski BM: Direction and rate of socket wear in Charnley low-friction arthroplasty. J Bone Joint Surg Br 67:757, 1985
-
(1985)
J Bone Joint Surg Br
, vol.67
, pp. 757
-
-
Wroblewski, B.M.1
-
4
-
-
0025222261
-
Osteolysis in alloarthroplasty of the hip: The role of ultra-high molecular weight polyethylene wear particles
-
Willert HG, Bertram H, Buchhorn GH: Osteolysis in alloarthroplasty of the hip: the role of ultra-high molecular weight polyethylene wear particles. Clin Orthop 258:95, 1990
-
(1990)
Clin Orthop
, vol.258
, pp. 95
-
-
Willert, H.G.1
Bertram, H.2
Buchhorn, G.H.3
-
5
-
-
0028325196
-
Osteolysis and particle disease in hip replacement: A review
-
Harris WH: Osteolysis and particle disease in hip replacement: a review. Acta Orthop Scand 65:113, 1994
-
(1994)
Acta Orthop Scand
, vol.65
, pp. 113
-
-
Harris, W.H.1
-
6
-
-
0026605414
-
Mechanism and clinical significance of wear debris-induced osteolysis
-
Amstutz HC, Campbell P, Kossovsky N, et al: Mechanism and clinical significance of wear debris-induced osteolysis. Clin Orthop 276:7, 1992
-
(1992)
Clin Orthop
, vol.276
, pp. 7
-
-
Amstutz, H.C.1
Campbell, P.2
Kossovsky, N.3
-
7
-
-
0025343488
-
Effect of femoral head size on wear of the polyethylene acetabular component
-
Livermore J, Ilstrup D, Morrey B: Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am 72:518, 1990
-
(1990)
J Bone Joint Surg Am
, vol.72
, pp. 518
-
-
Livermore, J.1
Ilstrup, D.2
Morrey, B.3
-
8
-
-
0028092171
-
Measurement of polyethylene thickness in total hip arthroplasty: A technique analysis
-
Bankston AB, Ritter MA, Keating EM, et al: Measurement of polyethylene thickness in total hip arthroplasty: a technique analysis. J Arthroplasty 9:533, 1994
-
(1994)
J Arthroplasty
, vol.9
, pp. 533
-
-
Bankston, A.B.1
Ritter, M.A.2
Keating, E.M.3
-
9
-
-
0027201038
-
Socket wear assessment: A comparison of three different radiographic methods
-
Ohlin A, Selvik G: Socket wear assessment: a comparison of three different radiographic methods. J Arthroplasty 8:427, 1993
-
(1993)
J Arthroplasty
, vol.8
, pp. 427
-
-
Ohlin, A.1
Selvik, G.2
-
10
-
-
0023007566
-
The effect of conformity, thickness, and material on stresses in ultrahigh molecular weight components for total joint replacement
-
Bartel DL, Bicknell VL, Wright TM: The effect of conformity, thickness, and material on stresses in ultrahigh molecular weight components for total joint replacement. J Bone Joint Surg Am 68:1041, 1986
-
(1986)
J Bone Joint Surg Am
, vol.68
, pp. 1041
-
-
Bartel, D.L.1
Bicknell, V.L.2
Wright, T.M.3
-
11
-
-
0030064144
-
Polyethylene wear in the Charnley offset bore acetabular cup: A radiological analysis
-
Izquierdo-Avino RJ, Siney AR, Siney PD, Wroblewski BM: Polyethylene wear in the Charnley offset bore acetabular cup: a radiological analysis. J Bone Joint Surg Br 78:82, 1996
-
(1996)
J Bone Joint Surg Br
, vol.78
, pp. 82
-
-
Izquierdo-Avino, R.J.1
Siney, A.R.2
Siney, P.D.3
Wroblewski, B.M.4
-
12
-
-
0030666239
-
Three-dimensional analysis of multiple wear vectors in retrieved acetabular cups
-
Yamaguchi M, Bauer TW, Hashimoto Y: Three-dimensional analysis of multiple wear vectors in retrieved acetabular cups. J Bone Joint Surg Am 79:1539, 1997
-
(1997)
J Bone Joint Surg Am
, vol.79
, pp. 1539
-
-
Yamaguchi, M.1
Bauer, T.W.2
Hashimoto, Y.3
-
13
-
-
12944295702
-
The effects of localized regions of head roughening on variability of UHMWPE wear in THA
-
Nieman JC, Brown TD, Pedersen DR, et al: The effects of localized regions of head roughening on variability of UHMWPE wear in THA. Trans Orthop Res Soc 23:77, 1998
-
(1998)
Trans Orthop Res Soc
, vol.23
, pp. 77
-
-
Nieman, J.C.1
Brown, T.D.2
Pedersen, D.R.3
-
15
-
-
0032014520
-
Wear of polyethylene in artificial hip joints: Superolateral wear of the acetabulum
-
Fisher J: Wear of polyethylene in artificial hip joints: superolateral wear of the acetabulum. J Bone Joint Surg Br 80:190, 1998
-
(1998)
J Bone Joint Surg Br
, vol.80
, pp. 190
-
-
Fisher, J.1
-
16
-
-
0345705972
-
"In vivo" determination of hip joint separation that may lead to impulse loading conditions
-
Northcut EJ, Komistek RD, Dennis DA, et al: "In vivo" determination of hip joint separation that may lead to impulse loading conditions. Trans Orthop Res Soc 23:197, 1998
-
(1998)
Trans Orthop Res Soc
, vol.23
, pp. 197
-
-
Northcut, E.J.1
Komistek, R.D.2
Dennis, D.A.3
-
17
-
-
0028245867
-
Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components
-
Huk OL, Bansal M, Betts F, et al: Polyethylene and metal debris generated by non-articulating surfaces of modular acetabular components. J Bone Joint Surg Br 76:568, 1994
-
(1994)
J Bone Joint Surg Br
, vol.76
, pp. 568
-
-
Huk, O.L.1
Bansal, M.2
Betts, F.3
-
18
-
-
0029829977
-
Wear of the polyethylene liner-metallic shell interface in modular acetabular components: An in vitro analysis
-
Lieberman JR, Kay RM, Hamlet WP, et al: Wear of the polyethylene liner-metallic shell interface in modular acetabular components: an in vitro analysis. J Arthroplasty 11:602, 1996
-
(1996)
J Arthroplasty
, vol.11
, pp. 602
-
-
Lieberman, J.R.1
Kay, R.M.2
Hamlet, W.P.3
-
19
-
-
0028057541
-
Wear debris: An environmental issue in total joint replacement
-
Manley MT, Serekian P: Wear debris: an environmental issue in total joint replacement. Clin Orthop 298:137, 1994
-
(1994)
Clin Orthop
, vol.298
, pp. 137
-
-
Manley, M.T.1
Serekian, P.2
-
20
-
-
0022107624
-
The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants
-
Bartel DL, Burstein AH, Toda MD, et al: The effect of conformity and plastic thickness on contact stresses in metal-backed plastic implants. J Biomech Eng 107: 193, 1985
-
(1985)
J Biomech Eng
, vol.107
, pp. 193
-
-
Bartel, D.L.1
Burstein, A.H.2
Toda, M.D.3
-
21
-
-
0006465555
-
The effect of gaps on contact stress and relative motion in a metal-backed acetabular component for THR
-
Kurtz SM, Bartel DL, Edidin AA: The effect of gaps on contact stress and relative motion in a metal-backed acetabular component for THR. Trans Orthop Res Soc 19:243, 1994
-
(1994)
Trans Orthop Res Soc
, vol.19
, pp. 243
-
-
Kurtz, S.M.1
Bartel, D.L.2
Edidin, A.A.3
-
22
-
-
0029794815
-
Wear of polyethylene cups in total hip arthroplasty: A study of specimens retrieved post mortem
-
Sychterz CJ, Moon KH, Hashimoto Y, et al: Wear of polyethylene cups in total hip arthroplasty: a study of specimens retrieved post mortem. J Bone Joint Surg Am 78:1193, 1996
-
(1996)
J Bone Joint Surg Am
, vol.78
, pp. 1193
-
-
Sychterz, C.J.1
Moon, K.H.2
Hashimoto, Y.3
-
23
-
-
0012962157
-
Polyethylene wear in total hip arthroplasty: Volumetric wear measurement of retrieved acetabular components
-
Hashimoto Y, Bauer TW, Jiang M, et al: Polyethylene wear in total hip arthroplasty: volumetric wear measurement of retrieved acetabular components. Trans Orthop Res Soc 20:116, 1995
-
(1995)
Trans Orthop Res Soc
, vol.20
, pp. 116
-
-
Hashimoto, Y.1
Bauer, T.W.2
Jiang, M.3
-
24
-
-
0028999144
-
Radiographic calculation of anteversion in acetabular prostheses
-
Hassan DM, Johnston GH, Dust WN, et al: Radiographic calculation of anteversion in acetabular prostheses. J Arthroplasty 10:369, 1995
-
(1995)
J Arthroplasty
, vol.10
, pp. 369
-
-
Hassan, D.M.1
Johnston, G.H.2
Dust, W.N.3
-
25
-
-
0014457406
-
The optimum size of prosthetic heads in relation to the wear of plastic sockets in total replacement of the hip
-
Charnley J, Kamangar A, Longfield MD: The optimum size of prosthetic heads in relation to the wear of plastic sockets in total replacement of the hip. Med Biol Eng 7:31, 1969
-
(1969)
Med Biol Eng
, vol.7
, pp. 31
-
-
Charnley, J.1
Kamangar, A.2
Longfield, M.D.3
-
26
-
-
0016823891
-
Rate of wear in total hip replacement
-
Charnley J, Halley DK: Rate of wear in total hip replacement. Clin Orthop 112:170, 1975
-
(1975)
Clin Orthop
, vol.112
, pp. 170
-
-
Charnley, J.1
Halley, D.K.2
-
28
-
-
0008909176
-
Presence of multiple wear directions in autopsy retrieved acetabular components
-
Wimmer MA, Berzins A, Kuhn H, et al: Presence of multiple wear directions in autopsy retrieved acetabular components. Trans Orthop Res Soc 23:78, 1998
-
(1998)
Trans Orthop Res Soc
, vol.23
, pp. 78
-
-
Wimmer, M.A.1
Berzins, A.2
Kuhn, H.3
-
29
-
-
0031172144
-
The role of backside polishing, cup angle, and polyethylene thickness on the contact stresses in metal-backed acetabular components
-
Kurtz SM, Edidin AA, Bartel DL: The role of backside polishing, cup angle, and polyethylene thickness on the contact stresses in metal-backed acetabular components. J Biomech 30:639, 1997
-
(1997)
J Biomech
, vol.30
, pp. 639
-
-
Kurtz, S.M.1
Edidin, A.A.2
Bartel, D.L.3
-
30
-
-
0032071068
-
Backside nonconformity and locking restrains affect liner/shell load transfer mechanisms and relative motion in modular acetabular components for total hip replacement
-
Kurtz SM, Ochoa JA, White CV, et al: Backside nonconformity and locking restrains affect liner/shell load transfer mechanisms and relative motion in modular acetabular components for total hip replacement. J Biomech 31:431, 1998
-
(1998)
J Biomech
, vol.31
, pp. 431
-
-
Kurtz, S.M.1
Ochoa, J.A.2
White, C.V.3
-
31
-
-
0018875099
-
On the true wear rate of ultra high-molecular-weight polyethylene in the total hip prosthesis
-
Rose RM, Nusbaum HJ, Schneider H, et al: On the true wear rate of ultra high-molecular-weight polyethylene in the total hip prosthesis. J Bone Joint Surg Am 62:537, 1980
-
(1980)
J Bone Joint Surg Am
, vol.62
, pp. 537
-
-
Rose, R.M.1
Nusbaum, H.J.2
Schneider, H.3
-
32
-
-
0030903723
-
Wear of polyethylene acetabular components in total hip arthroplasty: An analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations
-
Jasty M, Goetz DD, Bragdon CR, et al: Wear of polyethylene acetabular components in total hip arthroplasty: an analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations. J Bone Joint Surg Am 79:349, 1997
-
(1997)
J Bone Joint Surg Am
, vol.79
, pp. 349
-
-
Jasty, M.1
Goetz, D.D.2
Bragdon, C.R.3
-
33
-
-
0030726816
-
Complications of total hip arthroplasty associated with the use of an acetabular component with a Hylamer liner
-
Livingston BJ, Chmell MJ, Spector M, et al: Complications of total hip arthroplasty associated with the use of an acetabular component with a Hylamer liner. J Bone Joint Surg Am 79:1529, 1997
-
(1997)
J Bone Joint Surg Am
, vol.79
, pp. 1529
-
-
Livingston, B.J.1
Chmell, M.J.2
Spector, M.3
-
34
-
-
0029989624
-
Early failure of Hylamer acetabular inserts due to eccentric wear
-
Chmell MJ, Poss R, Thomas WH, et al: Early failure of Hylamer acetabular inserts due to eccentric wear. J Arthroplasty 11:351, 1996
-
(1996)
J Arthroplasty
, vol.11
, pp. 351
-
-
Chmell, M.J.1
Poss, R.2
Thomas, W.H.3
|