1
-
-
0031427940
-
Pedicle screw fixation for nontraumatic lesions of the cervical spine
-
Abumi K, Kaneda K. Pedicle screw fixation for nontraumatic lesions of the cervical spine. Spine 1997; 22(16): 1853-1863.
-
(1997)
Spine
, vol.22
, Issue.16
, pp. 1853-1863
-
-
Abumi, K.1
Kaneda, K.2
-
2
-
-
0030814925
-
Early complications of spinal pedicle screw
-
Faraj AA, Webb JK. Early complications of spinal pedicle screw. Eur Spine J 1997; 6(5):324-326.
-
(1997)
Eur Spine J
, vol.6
, Issue.5
, pp. 324-326
-
-
Faraj, A.A.1
Webb, J.K.2
-
3
-
-
0033794424
-
The use of pedicle-screw internal fixation for the operative treatment of spinal disorders
-
Gaines RW Jr. The use of pedicle-screw internal fixation for the operative treatment of spinal disorders. J Bone Joint Surg Am 2000; 82(10):1458-1476.
-
(2000)
J Bone Joint Surg Am
, vol.82
, Issue.10
, pp. 1458-1476
-
-
Gaines Jr., R.W.1
-
4
-
-
0031416028
-
Carbonated apatite cement augmentation of pedicle screw fixation in the lumbar spine
-
Lotz JC, Hu SS, Chin DF, et al. Carbonated apatite cement augmentation of pedicle screw fixation in the lumbar spine. Spine 1997; 22(23):2716-2723.
-
(1997)
Spine
, vol.22
, Issue.23
, pp. 2716-2723
-
-
Lotz, J.C.1
Hu, S.S.2
Chin, D.F.3
-
5
-
-
0035884966
-
Thoracic pedicle screw fixation in spinal deformities: Are they really safe?
-
Suk SI, Kim WJ, Lee SM, et al. Thoracic pedicle screw fixation in spinal deformities: are they really safe? Spine 2001; 26(18):2049-2057.
-
(2001)
Spine
, vol.26
, Issue.18
, pp. 2049-2057
-
-
Suk, S.I.1
Kim, W.J.2
Lee, S.M.3
-
6
-
-
0025153831
-
Influence of bone mineral density on the fixation of thoracolumbar implants. A comparative study of transpedicular screws, laminar hooks, and spinous process wires
-
Coe JD, Warden KE, Herzig MA, et al. Influence of bone mineral density on the fixation of thoracolumbar implants. A comparative study of transpedicular screws, laminar hooks, and spinous process wires. Spine 1990; 15(9):902-907.
-
(1990)
Spine
, vol.15
, Issue.9
, pp. 902-907
-
-
Coe, J.D.1
Warden, K.E.2
Herzig, M.A.3
-
7
-
-
33644841640
-
Influence of screw positioning in a new anterior spine fixator on implant loosening in osteoporotic vertebrae
-
Reinhold M, Schwieger K, Goldhahn J, et al. Influence of screw positioning in a new anterior spine fixator on implant loosening in osteoporotic vertebrae. Spine 2006; 31(4):406-413.
-
(2006)
Spine
, vol.31
, Issue.4
, pp. 406-413
-
-
Reinhold, M.1
Schwieger, K.2
Goldhahn, J.3
-
8
-
-
4043175645
-
Biomechanical evaluation of relationship of screw pullout strength, insertional torque, and bone mineral density in the cervical spine
-
Reitman CA, Nguyen L, Fogel GR. Biomechanical evaluation of relationship of screw pullout strength, insertional torque, and bone mineral density in the cervical spine. J Spinal Disord Tech 2004; 17(4):306-311.
-
(2004)
J Spinal Disord Tech
, vol.17
, Issue.4
, pp. 306-311
-
-
Reitman, C.A.1
Nguyen, L.2
Fogel, G.R.3
-
9
-
-
0025903474
-
Importance of bone mineral density in instrumented spine fusions
-
Wittenberg RH, Shea M, Swartz DE, et al. Importance of bone mineral density in instrumented spine fusions. Spine 1991; 16(6):647-652.
-
(1991)
Spine
, vol.16
, Issue.6
, pp. 647-652
-
-
Wittenberg, R.H.1
Shea, M.2
Swartz, D.E.3
-
10
-
-
21844480606
-
Increase of pullout strength of spinal pedicle screws with conical core: Biomechanical tests and finite element analyses
-
Hsu CC, Chao CK, Wang JL, et al. Increase of pullout strength of spinal pedicle screws with conical core: biomechanical tests and finite element analyses. J Orthop Res 2005;23(4): 788-794.
-
(2005)
J Orthop Res
, vol.23
, Issue.4
, pp. 788-794
-
-
Hsu, C.C.1
Chao, C.K.2
Wang, J.L.3
-
11
-
-
0036166754
-
Biomechanical evaluation of a double-threaded pedicle screw in elderly vertebrae
-
Mummaneni PV, Haddock SM, Liebschner MA, et al. Biomechanical evaluation of a double-threaded pedicle screw in elderly vertebrae. J Spinal Disord Tech 2002; 15(1):64-68.
-
(2002)
J Spinal Disord Tech
, vol.15
, Issue.1
, pp. 64-68
-
-
Mummaneni, P.V.1
Haddock, S.M.2
Liebschner, M.A.3
-
12
-
-
0033082890
-
Biomechanical evaluation of a newly developed monocortical expansion screw for use in anterior internal fixation of the cervical spine. In vitro comparison with two established internal fixation systems
-
Richter M, Wilke HJ, Kluger P, et al. Biomechanical evaluation of a newly developed monocortical expansion screw for use in anterior internal fixation of the cervical spine. In vitro comparison with two established internal fixation systems. Spine 1999; 24(3):207-212.
-
(1999)
Spine
, vol.24
, Issue.3
, pp. 207-212
-
-
Richter, M.1
Wilke, H.J.2
Kluger, P.3
-
13
-
-
0034463634
-
Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design
-
Cook SD, Salkeld SL, Whitecloud TS 3rd, et al. Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design. J Spinal Disord 2000; 13(3): 230-236.
-
(2000)
J Spinal Disord
, vol.13
, Issue.3
, pp. 230-236
-
-
Cook, S.D.1
Salkeld, S.L.2
Whitecloud 3rd, T.S.3
-
14
-
-
0035893832
-
Augmentation of anterior vertebral body screw fixation by an injectable, biodegradable calcium phosphate bone substitute
-
Bai B, Kummer FJ, Spivak J. Augmentation of anterior vertebral body screw fixation by an injectable, biodegradable calcium phosphate bone substitute. Spine 2001; 26(24):2679-2683.
-
(2001)
Spine
, vol.26
, Issue.24
, pp. 2679-2683
-
-
Bai, B.1
Kummer, F.J.2
Spivak, J.3
-
15
-
-
0028314201
-
Repair of failed transpedicle screw fixation. A biomechanical study comparing polymethylmethacrylate, milled bone, and matchstick bone reconstruction
-
Pfeifer BA, Krag MH, Johnson C. Repair of failed transpedicle screw fixation. A biomechanical study comparing polymethylmethacrylate, milled bone, and matchstick bone reconstruction. Spine 1994; 19(3):350-353.
-
(1994)
Spine
, vol.19
, Issue.3
, pp. 350-353
-
-
Pfeifer, B.A.1
Krag, M.H.2
Johnson, C.3
-
16
-
-
3042742564
-
Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method
-
Renner SM, Lim TH, Kim WJ, et al. Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method. Spine 2004; 29(11):212-216.
-
(2004)
Spine
, vol.29
, Issue.11
, pp. 212-216
-
-
Renner, S.M.1
Lim, T.H.2
Kim, W.J.3
-
17
-
-
0038120842
-
Enhancement of pedicle screw stability using calcium phosphate cement in osteoporotic vertebrae: In vivo biomechanical study
-
Taniwaki Y, Takemasa R, Tani T, et al. Enhancement of pedicle screw stability using calcium phosphate cement in osteoporotic vertebrae: in vivo biomechanical study. J Orthop Sci 2003; 8(3):408-414.
-
(2003)
J Orthop Sci
, vol.8
, Issue.3
, pp. 408-414
-
-
Taniwaki, Y.1
Takemasa, R.2
Tani, T.3
-
18
-
-
0032143033
-
Revision of failed pedicle screws using hydroxyapatite cement. A biomechanical analysis
-
Yerby SA, Toh E, McLain RF. Revision of failed pedicle screws using hydroxyapatite cement. A biomechanical analysis. Spine 1998; 23(15):1657-1661.
-
(1998)
Spine
, vol.23
, Issue.15
, pp. 1657-1661
-
-
Yerby, S.A.1
Toh, E.2
McLain, R.F.3
-
19
-
-
0032729089
-
Complications associated with pedicle screws
-
Lonstein JE, Denis F, Perra JH, et al. Complications associated with pedicle screws. J Bone Joint Surg Am 1999; 81 (11):1519-1528.
-
(1999)
J Bone Joint Surg Am
, vol.81
, Issue.11
, pp. 1519-1528
-
-
Lonstein, J.E.1
Denis, F.2
Perra, J.H.3
-
20
-
-
0025988460
-
An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine
-
Soshi S, Shiba S, Kondo H, et al. An experimental study on transpedicular screw fixation in relation to osteoporosis of the lumbar spine. Spine 1991; 16(11):1335-1341.
-
(1991)
Spine
, vol.16
, Issue.11
, pp. 1335-1341
-
-
Soshi, S.1
Shiba, S.2
Kondo, H.3
-
21
-
-
0028012866
-
Neurological deterioration after cement injection into a vertebral body
-
Wilkes RA, Mackinnon J, Thomas W. Neurological deterioration after cement injection into a vertebral body. J Bone Joint Surg Br 1994; 76(1):155.
-
(1994)
J Bone Joint Surg Br
, vol.76
, Issue.1
, pp. 155
-
-
Wilkes, R.A.1
Mackinnon, J.2
Thomas, W.3
-
22
-
-
33644641656
-
Biomechanical evaluation of an expansive pedicle screw in calf vertebrae
-
Lei W, Wu ZX. Biomechanical evaluation of an expansive pedicle screw in calf vertebrae. Eur Spine J 2006; 15(3):321-326.
-
(2006)
Eur Spine J
, vol.15
, Issue.3
, pp. 321-326
-
-
Lei, W.1
Wu, Z.X.2
-
23
-
-
0036285021
-
Bone changes due to glucocorticoid application in an ovariectomized animal model for fracture treatment in osteoporosis
-
Lill CA, Gerlach UV, Eckhardt C, et al. Bone changes due to glucocorticoid application in an ovariectomized animal model for fracture treatment in osteoporosis. Osteoporos Int 2002; 13 (5):407-414.
-
(2002)
Osteoporos Int
, vol.13
, Issue.5
, pp. 407-414
-
-
Lill, C.A.1
Gerlach, U.V.2
Eckhardt, C.3
-
24
-
-
0034327227
-
Sheep model for fracture treatment in osteoporotic bone: A pilot study about different induction regimens
-
Lill CA, Fluegel AK, Schneider E. Sheep model for fracture treatment in osteoporotic bone: a pilot study about different induction regimens. J Orthop Trauma 2000; 14(8):559-566.
-
(2000)
J Orthop Trauma
, vol.14
, Issue.8
, pp. 559-566
-
-
Lill, C.A.1
Fluegel, A.K.2
Schneider, E.3
-
25
-
-
0036861713
-
Effects of short-term alendronate treatment on the three-dimensional microstructural, physical, and mechanical properties of dog trabecular bone
-
Hu JH, Ding M, Soballe K, et al. Effects of short-term alendronate treatment on the three-dimensional microstructural, physical, and mechanical properties of dog trabecular bone. Bone 2002; 31(5):591-597.
-
(2002)
Bone
, vol.31
, Issue.5
, pp. 591-597
-
-
Hu, J.H.1
Ding, M.2
Soballe, K.3
-
26
-
-
0346319024
-
Micro CT evaluation of normal and osteoarthritic bone structure in human knee specimens
-
Patel V, Issever AS, Burghardt A. Micro CT evaluation of normal and osteoarthritic bone structure in human knee specimens. J Orthop Res 2003; 21(1):6-13.
-
(2003)
J Orthop Res
, vol.21
, Issue.1
, pp. 6-13
-
-
Patel, V.1
Issever, A.S.2
Burghardt, A.3
-
27
-
-
0347356609
-
Bone loss induced by dietary magnesium reduction to 10% of the nutrient requirement in rats is associated with increased release of substance P and tumor necrosis factor-alpha
-
Rude RK, Gruber HE, Norton HJ, et al. Bone loss induced by dietary magnesium reduction to 10% of the nutrient requirement in rats is associated with increased release of substance P and tumor necrosis factor-alpha. J Nutr 2004; 134(1): 79-85.
-
(2004)
J Nutr
, vol.134
, Issue.1
, pp. 79-85
-
-
Rude, R.K.1
Gruber, H.E.2
Norton, H.J.3
-
28
-
-
0028800124
-
Skeletal adaptations to mechanical usage: Results from tibial loading studies in rats
-
Forwood MR, Turner CH. Skeletal adaptations to mechanical usage: results from tibial loading studies in rats. Bone 1995; 17(4):197-205.
-
(1995)
Bone
, vol.17
, Issue.4
, pp. 197-205
-
-
Forwood, M.R.1
Turner, C.H.2
-
29
-
-
42449139358
-
Biomechanical model of vertebra based on bone remodeling
-
Jovanovie JD, Jovanovie MLJ. Biomechanical model of vertebra based on bone remodeling. Med Biol 2004; 11(1):35-39.
-
(2004)
Med Biol
, vol.11
, Issue.1
, pp. 35-39
-
-
Jovanovie, J.D.1
Jovanovie, M.L.J.2
|