메뉴 건너뛰기




Volumn 31, Issue 1, 2008, Pages 18-23

Stereotactic dose perturbation from an aneurysm clip measured by Gafchromic®EBT film

Author keywords

Gafchromic film; Radiochromic film dosimetry; Stereotactic radiosurgery

Indexed keywords

OPTICAL RESOLVING POWER; RADIOTHERAPY; SCANNING; TITANIUM ALLOYS;

EID: 42249106389     PISSN: 01589938     EISSN: None     Source Type: Journal    
DOI: 10.1007/BF03178449     Document Type: Article
Times cited : (7)

References (22)
  • 2
    • 34447103490 scopus 로고    scopus 로고
    • Intravesical markers for delineation of target volume during external focal irradiation of bladder carcinomas
    • P
    • Hulshof, M., van Andel, G., Bel, A. et al., Intravesical markers for delineation of target volume during external focal irradiation of bladder carcinomas. Radiotherapy and Oncology, 84(1): P. 49-51, 2007.
    • (2007) Radiotherapy and Oncology , vol.84 , Issue.1 , pp. 49-51
    • Hulshof, M.1    van Andel, G.2    Bel, A.3
  • 3
    • 0030731992 scopus 로고    scopus 로고
    • Dosimetry studies with TLDs for stereotactic radiation techniques for intraocular tumours
    • P
    • Ertl, A., Zehetmayer, M., Schoggl, A. et al., Dosimetry studies with TLDs for stereotactic radiation techniques for intraocular tumours. Phys. Med. Biol, 42: P. 2137-2145, 1997.
    • (1997) Phys. Med. Biol , vol.42 , pp. 2137-2145
    • Ertl, A.1    Zehetmayer, M.2    Schoggl, A.3
  • 4
    • 33744809043 scopus 로고    scopus 로고
    • Peripheral doses in CyberKnife radiosurgery
    • Petti, P.L., Chuang, C.F., Smith, V., et al., Peripheral doses in CyberKnife radiosurgery. Medical Physics, 33 (6):p.1770-1779, 2006.
    • (2006) Medical Physics , vol.33 , Issue.6 , pp. 1770-1779
    • Petti, P.L.1    Chuang, C.F.2    Smith, V.3
  • 5
    • 0032727433 scopus 로고    scopus 로고
    • The use of radiographic film for linear accelerator stereotactic radiosurgical dosimetry
    • Robar, J.L. and Clark, B.G., The use of radiographic film for linear accelerator stereotactic radiosurgical dosimetry. Medical Physics, 26(10):p.2144-2150, 1999.
    • (1999) Medical Physics , vol.26 , Issue.10 , pp. 2144-2150
    • Robar, J.L.1    Clark, B.G.2
  • 6
    • 33947417069 scopus 로고    scopus 로고
    • Verification of dose volume histograms in stereotactic radiosurgery andradiotherapy using polymer gel and MRI
    • Journal of Physics
    • Semnická, J., J. Novotný Jr, Spevácek, V. et al., Verification of dose volume histograms in stereotactic radiosurgery andradiotherapy using polymer gel and MRI. Journal of Physics: Conference Series, 56:p.296-299, 2006.
    • (2006) Conference Series , vol.56 , pp. 296-299
    • Semnická, J.1    Novotný Jr, J.2    Spevácek, V.3
  • 7
    • 34247641764 scopus 로고    scopus 로고
    • Application of polymer-gel dosimetry in stereotactic radiosurgery
    • P
    • Novotny, J., Spevacek, V., Dvorak, P. et al., Application of polymer-gel dosimetry in stereotactic radiosurgery. Journal of Physics Conference Series, 3: P. 288-292, 2004.
    • (2004) Journal of Physics Conference Series , vol.3 , pp. 288-292
    • Novotny, J.1    Spevacek, V.2    Dvorak, P.3
  • 8
    • 34247616869 scopus 로고    scopus 로고
    • Gamma Knife 3-D dose distribution near the area of tissue inhomogeneities by normoxic gel dosimetry
    • Isbakan, F., Ülgen, Y., Bilge, H. et al., Gamma Knife 3-D dose distribution near the area of tissue inhomogeneities by normoxic gel dosimetry. Medical Physics, 34(5):p.1623-1630, 2007.
    • (2007) Medical Physics , vol.34 , Issue.5 , pp. 1623-1630
    • Isbakan, F.1    Ülgen, Y.2    Bilge, H.3
  • 9
    • 2442701589 scopus 로고    scopus 로고
    • GAFChromic film dosimetry with a flatbed color scanner for Leksell Gamma Knife therapy
    • P
    • Yamauchi, M., Tominaga, T., Nakamura, O. et al., GAFChromic film dosimetry with a flatbed color scanner for Leksell Gamma Knife therapy. Med Phys, 31(5): P. 1243-1248, 2004.
    • (2004) Med Phys , vol.31 , Issue.5 , pp. 1243-1248
    • Yamauchi, M.1    Tominaga, T.2    Nakamura, O.3
  • 10
    • 34447321620 scopus 로고    scopus 로고
    • Evaluation of GAFCHROMIC EBT film for CyberKnife dosimetry
    • P
    • Wilcox, E. and Daskalov, G., Evaluation of GAFCHROMIC EBT film for CyberKnife dosimetry. Medical Physics, 34(6): P. 1967-1974, 2007.
    • (2007) Medical Physics , vol.34 , Issue.6 , pp. 1967-1974
    • Wilcox, E.1    Daskalov, G.2
  • 11
    • 0038710309 scopus 로고    scopus 로고
    • Dose distribution close to metal implants in Gamma Knife Radiosurgery: A Monte Carlo study
    • Cheung, J., Yu, K., Chan, J. et al., Dose distribution close to metal implants in Gamma Knife Radiosurgery: A Monte Carlo study. Medical Physics, 30(7):1812-1815, 2003.
    • (2003) Medical Physics , vol.30 , Issue.7 , pp. 1812-1815
    • Cheung, J.1    Yu, K.2    Chan, J.3
  • 12
    • 7244226232 scopus 로고    scopus 로고
    • Dose enhancement close to platinum implants for the 4, 6, and 10 MV stereotactic radiosurgery
    • Cheung, J., Ng, B. and Yu, K., Dose enhancement close to platinum implants for the 4, 6, and 10 MV stereotactic radiosurgery. Medical Physics, 31(10):p.2787-2791, 2004.
    • (2004) Medical Physics , vol.31 , Issue.10 , pp. 2787-2791
    • Cheung, J.1    Ng, B.2    Yu, K.3
  • 14
    • 27644471150 scopus 로고    scopus 로고
    • Weak energy dependence of EBT gafchromic film dose response in the 50 kVp-10 MVp X-ray range
    • P
    • Butson, M.J., Cheung, T. and Yu, P.K., Weak energy dependence of EBT gafchromic film dose response in the 50 kVp-10 MVp X-ray range. Appl Radiat Isot, 64(1): P. 60-62, 2006.
    • (2006) Appl Radiat Isot , vol.64 , Issue.1 , pp. 60-62
    • Butson, M.J.1    Cheung, T.2    Yu, P.K.3
  • 15
    • 23944525811 scopus 로고    scopus 로고
    • Palm and LoSasso, T., Influence of phantom material and phantom size on radiographic film response in therapy photon beams. Medical Physics, 32(8): P. 2434-2442, 2005.
    • Palm and LoSasso, T., Influence of phantom material and phantom size on radiographic film response in therapy photon beams. Medical Physics, 32(8): P. 2434-2442, 2005.
  • 16
    • 33749829646 scopus 로고    scopus 로고
    • New developments in radiochromic film dosimetry
    • P
    • Soares, C., New developments in radiochromic film dosimetry. Radiation Protection Dosimetry, 120(1-4): P. 100-106, 2006.
    • (2006) Radiation Protection Dosimetry , vol.120 , Issue.1-4 , pp. 100-106
    • Soares, C.1
  • 17
    • 33845229491 scopus 로고    scopus 로고
    • High density dental materials and radiotherapy planning: Comparison of the dose predictions using superposition algorithm and fluence map Monte Carlo method with radiochromic film measurements
    • P
    • Spirydovich, S., Papiez, L., Langer, M. et al., High density dental materials and radiotherapy planning: Comparison of the dose predictions using superposition algorithm and fluence map Monte Carlo method with radiochromic film measurements. Radiotherapy and Oncology, 81(3): P. 309-314, 2006.
    • (2006) Radiotherapy and Oncology , vol.81 , Issue.3 , pp. 309-314
    • Spirydovich, S.1    Papiez, L.2    Langer, M.3
  • 18
    • 33750197979 scopus 로고    scopus 로고
    • Scanning orientation effects on Gafchromic EBT film dosimetry
    • Butson, M.J., Cheung, T. and Yu, P.K., Scanning orientation effects on Gafchromic EBT film dosimetry. Australas Phys Eng Sci Med, 29(3): p. 281-284, 2006.
    • (2006) Australas Phys Eng Sci Med , vol.29 , Issue.3 , pp. 281-284
    • Butson, M.J.1    Cheung, T.2    Yu, P.K.3
  • 20
    • 22544440841 scopus 로고    scopus 로고
    • Precise radiochromic film dosimetry using a flat-bed document scanner
    • P
    • Devic, S., Seuntjens, J., Sham, E. et al., Precise radiochromic film dosimetry using a flat-bed document scanner. Med Phys, 32(7): P. 2245-2253, 2005.
    • (2005) Med Phys , vol.32 , Issue.7 , pp. 2245-2253
    • Devic, S.1    Seuntjens, J.2    Sham, E.3
  • 21
    • 33750544711 scopus 로고    scopus 로고
    • Clinical use of EBT model Gafchromic film in radiotherapy
    • P
    • Fiandra, C., Ricardi, U., Ragona, R. et al., Clinical use of EBT model Gafchromic film in radiotherapy. Med Phys, 33(11): P. 4314-4319, 2006.
    • (2006) Med Phys , vol.33 , Issue.11 , pp. 4314-4319
    • Fiandra, C.1    Ricardi, U.2    Ragona, R.3
  • 22
    • 0033930191 scopus 로고    scopus 로고
    • Dose measurement based on spectral chi-square minimization using GAFchromic MD-55 film
    • P
    • Chan, G.H. and Prestwich, W.V., Dose measurement based on spectral chi-square minimization using GAFchromic MD-55 film. Phys Med Biol, 45(7): P. 1851-1861, 2000.
    • (2000) Phys Med Biol , vol.45 , Issue.7 , pp. 1851-1861
    • Chan, G.H.1    Prestwich, W.V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.