Volumn 45, Issue 7, 2000, Pages 1851-1861

Dose measurement based on spectral chi-square minimization using GAFchromic MD-55 film

Author keywords

[No Author keywords available]

Indexed keywords

COBALT 60; PHOSPHORUS 32;

EID: 0033930191     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/45/7/310     Document Type: Article
Times cited : (4)

References (9)
  • 1
    • 0024141233 scopus 로고
    • Algorithm 667: Sigma - a stochastic-integration global minimization algorithm
    • New York: Association for Computing Machinery
    • Aluffi-Pentini F, Parisi V and Zirilli F 1988 Algorithm 667: sigma - a stochastic-integration global minimization algorithm Collected Algorithms from ACM vol 14 (New York: Association for Computing Machinery) pp 366-88
    • (1988) Collected Algorithms from ACM , vol.14 , pp. 366-388
    • Aluffi-Pentini, F.1    Parisi, V.2    Zirilli, F.3
  • 2
    • 0026820342 scopus 로고
    • Tables of beta-ray dose distributions in water
    • AECL-10521 (Chalk River, Ontario: Atomic Energy of Canada Limited)
    • Cross W G, Freedman N O and Wong P Y 1992 Tables of beta-ray dose distributions in water AECL Report AECL-10521 (Chalk River, Ontario: Atomic Energy of Canada Limited)
    • (1992) AECL Report
    • Cross, W.G.1    Freedman, N.O.2    Wong, P.Y.3
  • 3
    • 0033006484 scopus 로고    scopus 로고
    • The use of GAFchromic film to determine the absolute activity of beta emitters
    • Fox R A, Barker P and Smart G 1999 The use of GAFchromic film to determine the absolute activity of beta emitters Phys. Med. Biol. 44 833-42
    • (1999) Phys. Med. Biol. , vol.44 , pp. 833-842
    • Fox, R.A.1    Barker, P.2    Smart, G.3
  • 4
    • 0031466420 scopus 로고    scopus 로고
    • GafChromic MD-55: Investigated as a precision dosimeter
    • Klassen N V, van der Zwan L and Cygler J 1997 GafChromic MD-55: investigated as a precision dosimeter Med. Phys. 24 1924-34
    • (1997) Med. Phys. , vol.24 , pp. 1924-1934
    • Klassen, N.V.1    Van Der Zwan, L.2    Cygler, J.3
  • 8
    • 0029909070 scopus 로고    scopus 로고
    • High-resolution dosimetry using radiochromic film and a document scanner
    • Stevens M A, Turner J R, Hugtenburg R P and Bulter P H 1996 High-resolution dosimetry using radiochromic film and a document scanner Phys. Med. Biol. 41 2357-65
    • (1996) Phys. Med. Biol. , vol.41 , pp. 2357-2365
    • Stevens, M.A.1    Turner, J.R.2    Hugtenburg, R.P.3    Bulter, P.H.4
  • 9
    • 0031045089 scopus 로고    scopus 로고
    • Quantitative evaluation of radiochromic film response for two-dimensional dosimetry
    • Zhu Y, Kirov A S, Mishra V, Meigooni A S and Williamson J F 1997 Quantitative evaluation of radiochromic film response for two-dimensional dosimetry Med. Phys. 24 223-31
    • (1997) Med. Phys. , vol.24 , pp. 223-231
    • Zhu, Y.1    Kirov, A.S.2    Mishra, V.3    Meigooni, A.S.4    Williamson, J.F.5