메뉴 건너뛰기




Volumn 42, Issue 11, 1997, Pages 2137-2145

Dosimetry studies with TLDs for stereotactic radiation techniques for intraocular tumours

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CONTROLLED STUDY; DOSIMETRY; HUMAN; INTRAOCULAR TUMOR; MAJOR CLINICAL STUDY; PRIORITY JOURNAL; RADIATION PHYSICS; RADIOSURGERY; STEREOTAXIC SURGERY;

EID: 0030731992     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/42/11/009     Document Type: Article
Times cited : (17)

References (24)
  • 3
    • 0027763280 scopus 로고
    • A tissue equivalent phantom for stereotactic radiosurgery localization and dose verification
    • Coffey C W, Sanders M, Cashon K, Miller R, Walsh J and Patel P 1993 A tissue equivalent phantom for stereotactic radiosurgery localization and dose verification Stereotact. Fund. Neurosurg. 61 (suppl 1) 130-41
    • (1993) Stereotact. Fund. Neurosurg. , vol.61 , Issue.SUPPL. 1 , pp. 130-141
    • Coffey, C.W.1    Sanders, M.2    Cashon, K.3    Miller, R.4    Walsh, J.5    Patel, P.6
  • 4
    • 0025495364 scopus 로고
    • Stereotactic radiosurgery using the 201 cobalt-60 source Gamma Knife
    • Coffey R J and Lunsford L D 1990 Stereotactic radiosurgery using the 201 cobalt-60 source Gamma Knife Neurosurg. Clin. N. Am. 1 933-54
    • (1990) Neurosurg. Clin. N. Am. , vol.1 , pp. 933-954
    • Coffey, R.J.1    Lunsford, L.D.2
  • 6
    • 0029823903 scopus 로고    scopus 로고
    • TLD array for precise dose measurements in stereotactic radiation techniques
    • Ertl A, Hartl R, Zehetmayer M, Kitz K and Griffitt W 1996 TLD array for precise dose measurements in stereotactic radiation techniques Phys. Med. Biol 41 2679-86
    • (1996) Phys. Med. Biol , vol.41 , pp. 2679-2686
    • Ertl, A.1    Hartl, R.2    Zehetmayer, M.3    Kitz, K.4    Griffitt, W.5
  • 7
    • 0023937331 scopus 로고
    • Influence of regenerating and evaluation procedures on the supralinear behavior of LiF thermoluminescent dosimeters
    • Feist H 1988 Influence of regenerating and evaluation procedures on the supralinear behavior of LiF thermoluminescent dosimeters Strahlenther. Onkol. 164 223-7
    • (1988) Strahlenther. Onkol. , vol.164 , pp. 223-227
    • Feist, H.1
  • 8
    • 0024327766 scopus 로고
    • Measurement and analysis of supralinearity in LiF TLD-100 irradiated by 1.5 keV x-rays
    • Folkard M, Roper M J and Michael B D 1989 Measurement and analysis of supralinearity in LiF TLD-100 irradiated by 1.5 keV x-rays Phys. Med. Biol. 34 707-15
    • (1989) Phys. Med. Biol. , vol.34 , pp. 707-715
    • Folkard, M.1    Roper, M.J.2    Michael, B.D.3
  • 9
    • 0026477745 scopus 로고
    • Linear accelerator radiosurgery
    • Friedman W A 1992 Linear accelerator radiosurgery Clin. Neurosurg. 38 445-71
    • (1992) Clin. Neurosurg. , vol.38 , pp. 445-471
    • Friedman, W.A.1
  • 11
    • 0030026160 scopus 로고    scopus 로고
    • A companion of dosimetry techniques in stereotactic radiosurgery
    • Heydarian M, Hoban P W and Beddoe A H 1996 A companion of dosimetry techniques in stereotactic radiosurgery Phys. Med. Biol. 41 93-110
    • (1996) Phys. Med. Biol. , vol.41 , pp. 93-110
    • Heydarian, M.1    Hoban, P.W.2    Beddoe, A.H.3
  • 13
    • 0023432874 scopus 로고
    • Supralinearity in thermoluminescence dose-response curves
    • _1987 Supralinearity in thermoluminescence dose-response curves Radiat. Res. 112 187-8
    • (1987) Radiat. Res. , vol.112 , pp. 187-188
  • 14
    • 0023237461 scopus 로고
    • Stereotactic radiosurgery
    • Leksell D G 1987 Stereotactic radiosurgery Neurol. Res. 9 60-8
    • (1987) Neurol. Res. , vol.9 , pp. 60-68
    • Leksell, D.G.1
  • 15
  • 17
    • 0028349847 scopus 로고
    • The use of radiochromic film in treatment verification of dynamic stereotactic radiosurgery
    • Ramani R, Lightstone A W, Mason D LD, O'Brien P F 1994 The use of radiochromic film in treatment verification of dynamic stereotactic radiosurgery Med. Phys. 21 389-92
    • (1994) Med. Phys. , vol.21 , pp. 389-392
    • Ramani, R.1    Lightstone, A.W.2    Mason, D.L.D.3    O'Brien, P.F.4
  • 18
    • 84907106851 scopus 로고
    • Selective shielding of a p-Si detector for quality independence
    • Rikner G and Grusell E 1985 Selective shielding of a p-Si detector for quality independence. Acta Radiol. Oncol. 24 65-9
    • (1985) Acta Radiol. Oncol. , vol.24 , pp. 65-69
    • Rikner, G.1    Grusell, E.2
  • 21
    • 0025005445 scopus 로고
    • The IAEA/WHO TL dosimetry service for radiotherapy centres 1969-87
    • Svensson H, Hanson G P and Zsdànszky K 1990 The IAEA/WHO TL dosimetry service for radiotherapy centres 1969-87 Acta Oncol. 29 461-7
    • (1990) Acta Oncol. , vol.29 , pp. 461-467
    • Svensson, H.1    Hanson, G.P.2    Zsdànszky, K.3
  • 23
    • 0026466465 scopus 로고
    • Physics and dosimetry of the Gamma Knife
    • Wu A 1992 Physics and dosimetry of the Gamma Knife Stereotact. Radiosurg. 3 35-50
    • (1992) Stereotact. Radiosurg. , vol.3 , pp. 35-50
    • Wu, A.1
  • 24
    • 1842412003 scopus 로고    scopus 로고
    • Stereotactic radiosurgery for uveal melanoma
    • ed D Kondziolka (Basel: Karger)
    • Zehetmayer M, Menapace R, Kitz K and Ertl A 1996 Stereotactic radiosurgery for uveal melanoma Radiosurgery 1995 ed D Kondziolka (Basel: Karger) pp 165-71
    • (1996) Radiosurgery 1995 , pp. 165-171
    • Zehetmayer, M.1    Menapace, R.2    Kitz, K.3    Ertl, A.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.