1
-
-
0003867545
-
-
Elsevier/Academic Press, San Diego
-
Ratner B.D., Hoffman A.S., Schoen F.J., and Lemons J.E. Biomaterials science: an introduction to materials in medicine (2004), Elsevier/Academic Press, San Diego
-
(2004)
Biomaterials science: an introduction to materials in medicine
-
-
Ratner, B.D.1
Hoffman, A.S.2
Schoen, F.J.3
Lemons, J.E.4
-
2
-
-
41549148624
-
-
Williams DF. Biofunctionality and Biocompatibility. In: Cahn RW, Haasen P, Kramer EJ, editors. Materials science and technology. A comprehensive treatment. vol. 14: Medical and dental materials. Weinheim: VCH; 1992. p. 2-26.
-
Williams DF. Biofunctionality and Biocompatibility. In: Cahn RW, Haasen P, Kramer EJ, editors. Materials science and technology. A comprehensive treatment. vol. 14: Medical and dental materials. Weinheim: VCH; 1992. p. 2-26.
-
-
-
-
3
-
-
0037051019
-
Biomedical surface science: foundations to frontiers
-
Castner D.G., and Ratner B.D. Biomedical surface science: foundations to frontiers. Surface Sci 500 (2002) 28-60
-
(2002)
Surface Sci
, vol.500
, pp. 28-60
-
-
Castner, D.G.1
Ratner, B.D.2
-
4
-
-
0037051037
-
Biological surface science
-
Kasemo B. Biological surface science. Surface Sci 500 (2002) 656-677
-
(2002)
Surface Sci
, vol.500
, pp. 656-677
-
-
Kasemo, B.1
-
5
-
-
41549146631
-
-
Fraker AC. Corrosion of metallic implants and prosthesis devices. In: ASTM metals handbook (9th ed.) vol. 13. Corrosion. Metals Park, OH: ASM International; 1987, p. 1324-35.
-
Fraker AC. Corrosion of metallic implants and prosthesis devices. In: ASTM metals handbook (9th ed.) vol. 13. Corrosion. Metals Park, OH: ASM International; 1987, p. 1324-35.
-
-
-
-
6
-
-
41549121422
-
-
Leclerc MF. Surgical implants. In: ASTM metals handbook (9th ed.) vol. 2. Metals Park, OH: ASM International; 1987, p. 164-80.
-
Leclerc MF. Surgical implants. In: ASTM metals handbook (9th ed.) vol. 2. Metals Park, OH: ASM International; 1987, p. 164-80.
-
-
-
-
8
-
-
0030339091
-
Metal implants and surface reactions
-
Steinemann S.G. Metal implants and surface reactions. Injury 27 (1996) SC16-SC22
-
(1996)
Injury
, vol.27
-
-
Steinemann, S.G.1
-
9
-
-
0000653880
-
Stability, reactivity and breakdown of passive films. Problems of recent and future research
-
Schultze J.W., and Lohrengel M.M. Stability, reactivity and breakdown of passive films. Problems of recent and future research. Electrochim Acta 45 (2000) 2499-2513
-
(2000)
Electrochim Acta
, vol.45
, pp. 2499-2513
-
-
Schultze, J.W.1
Lohrengel, M.M.2
-
10
-
-
0036002562
-
From Bacon to barriers: a review on the passivity of metals and alloys
-
Schmuki P. From Bacon to barriers: a review on the passivity of metals and alloys. J Solid State Electrochem 6 (2002) 145-164
-
(2002)
J Solid State Electrochem
, vol.6
, pp. 145-164
-
-
Schmuki, P.1
-
11
-
-
0038679478
-
Passive film on orthopaedic TiAlV alloy formed in physiological solution investigated by X-ray photoelectron spectroscopy
-
Milošev I., Metikoš-Huković M., and Strehblow H.-H. Passive film on orthopaedic TiAlV alloy formed in physiological solution investigated by X-ray photoelectron spectroscopy. Biomaterials 21 (2000) 2103-2113
-
(2000)
Biomaterials
, vol.21
, pp. 2103-2113
-
-
Milošev, I.1
Metikoš-Huković, M.2
Strehblow, H.-H.3
-
12
-
-
0034333617
-
The behavior of stainless steels in physiological solution containing complexing agent studied by X-ray photoelectron spectroscopy
-
Milošev I., and Strehblow H.-H. The behavior of stainless steels in physiological solution containing complexing agent studied by X-ray photoelectron spectroscopy. J Biomed Mater Res 52 (2000) 404-412
-
(2000)
J Biomed Mater Res
, vol.52
, pp. 404-412
-
-
Milošev, I.1
Strehblow, H.-H.2
-
13
-
-
0042171490
-
The composition of the surface passive film formed on CoCrMo alloy in simulated physiological solution
-
Milošev I., and Strehblow H.-H. The composition of the surface passive film formed on CoCrMo alloy in simulated physiological solution. Electrochim Acta 48 (2003) 2767-2774
-
(2003)
Electrochim Acta
, vol.48
, pp. 2767-2774
-
-
Milošev, I.1
Strehblow, H.-H.2
-
14
-
-
0347545262
-
Preparation and assessment of revised simulated body fluids
-
Oyane A., Kim H.M., Furya T., Kokubo T., Miyazaki T., and Nakamura T. Preparation and assessment of revised simulated body fluids. J Biomed Mat Res 65A (2003) 188-195
-
(2003)
J Biomed Mat Res
, vol.65 A
, pp. 188-195
-
-
Oyane, A.1
Kim, H.M.2
Furya, T.3
Kokubo, T.4
Miyazaki, T.5
Nakamura, T.6
-
15
-
-
34548149660
-
Biotribocorrosion of CoCrMo orthopaedic implant materials: assessing the formation and effect of the biofilm
-
Yan Y., Neville A., and Dowson D. Biotribocorrosion of CoCrMo orthopaedic implant materials: assessing the formation and effect of the biofilm. Tribol Int 40 (2007) 1492-1499
-
(2007)
Tribol Int
, vol.40
, pp. 1492-1499
-
-
Yan, Y.1
Neville, A.2
Dowson, D.3
-
16
-
-
0037285769
-
The influence of complexing agent and proteins on the corrosion of stainless steels and their metallic components
-
Minovič A., Milošev I., and Pihlar B. The influence of complexing agent and proteins on the corrosion of stainless steels and their metallic components. J Mater Sci-Mater Med 14 (2003) 69-77
-
(2003)
J Mater Sci-Mater Med
, vol.14
, pp. 69-77
-
-
Minovič, A.1
Milošev, I.2
Pihlar, B.3
-
17
-
-
0036507910
-
-
Milošev I. The effect of complexing agents on the electrochemical behaviour of orthopaedic stainless steel in physiological solution. J Appl Electrochem 1002;32:311-20.
-
Milošev I. The effect of complexing agents on the electrochemical behaviour of orthopaedic stainless steel in physiological solution. J Appl Electrochem 1002;32:311-20.
-
-
-
-
18
-
-
0033324013
-
Electrochemical studies of the adsorption behavior of bovine serum albumin on stainless steel
-
Omanović S., and Roscoe S.G. Electrochemical studies of the adsorption behavior of bovine serum albumin on stainless steel. Langmuir 15 (1999) 8315-8321
-
(1999)
Langmuir
, vol.15
, pp. 8315-8321
-
-
Omanović, S.1
Roscoe, S.G.2
-
19
-
-
0028351802
-
Competitive binding to chromium, cobalt and nickel to serum proteins
-
Yang J., and Black J. Competitive binding to chromium, cobalt and nickel to serum proteins. Biomaterials 15 (1994) 262-268
-
(1994)
Biomaterials
, vol.15
, pp. 262-268
-
-
Yang, J.1
Black, J.2
-
20
-
-
0033120166
-
The corrosion behaviour of Ti-6Al-4V, Ti-6Al-7Nb and Ti-13Nb-13Zr in protein solution
-
Khan M.A., Williams R.L., and Williams D.F. The corrosion behaviour of Ti-6Al-4V, Ti-6Al-7Nb and Ti-13Nb-13Zr in protein solution. Biomaterials 20 (1999) 631-637
-
(1999)
Biomaterials
, vol.20
, pp. 631-637
-
-
Khan, M.A.1
Williams, R.L.2
Williams, D.F.3
-
21
-
-
0037114412
-
Characterization of implant materials in fetal bovine serum and sodium sulphate by electrochemical impedance spectroscopy. I. Mechanically polished samples
-
Contu F., Elsener B., and Böhni H. Characterization of implant materials in fetal bovine serum and sodium sulphate by electrochemical impedance spectroscopy. I. Mechanically polished samples. J Biomed Mater Res 62 (2002) 412-421
-
(2002)
J Biomed Mater Res
, vol.62
, pp. 412-421
-
-
Contu, F.1
Elsener, B.2
Böhni, H.3
-
22
-
-
3242725743
-
Electrochemical corrosion properties of Ti-6Al-4V implant alloy in biological environment
-
Hsu R.W.-W., Yang C.-C., Huang C.-A., and Chen Y.-S. Electrochemical corrosion properties of Ti-6Al-4V implant alloy in biological environment. Mater Sci Eng A 380 (2004) 100-109
-
(2004)
Mater Sci Eng
, vol.A 380
, pp. 100-109
-
-
Hsu, R.W.-W.1
Yang, C.-C.2
Huang, C.-A.3
Chen, Y.-S.4
-
23
-
-
0016623853
-
Biomaterials: the interfacial problem
-
Hench L.L., and Ethridge E.C. Biomaterials: the interfacial problem. Adv Biomed Eng 5 (1975) 35-150
-
(1975)
Adv Biomed Eng
, vol.5
, pp. 35-150
-
-
Hench, L.L.1
Ethridge, E.C.2
-
24
-
-
0030453223
-
Crevice corrosion of cemented titanium alloy stems in total hip replacements
-
Willert H.-G., Brobäck L.-G., Buchhorn G.H., Jensen P.H., Köster G., Lang I., et al. Crevice corrosion of cemented titanium alloy stems in total hip replacements. Clin Orthop Related Res 333 (1996) 51-75
-
(1996)
Clin Orthop Related Res
, vol.333
, pp. 51-75
-
-
Willert, H.-G.1
Brobäck, L.-G.2
Buchhorn, G.H.3
Jensen, P.H.4
Köster, G.5
Lang, I.6
-
25
-
-
0034808709
-
Acid attack and cathepsin K in bone resorption around total hip replacement prosthesis
-
Konttinen Y.T., Takagi M., Mandelin J., Lassus J., Salo J., Ainola M., et al. Acid attack and cathepsin K in bone resorption around total hip replacement prosthesis. J Bone Miner Res 16 (2001) 1780-1786
-
(2001)
J Bone Miner Res
, vol.16
, pp. 1780-1786
-
-
Konttinen, Y.T.1
Takagi, M.2
Mandelin, J.3
Lassus, J.4
Salo, J.5
Ainola, M.6
-
26
-
-
0006026476
-
Wear: osteolysis related to metallic debris
-
Sedel L., and Cabanela M.E. (Eds), Martin Dunitz, London
-
Salvati E.A., and Gomez-Barrena E. Wear: osteolysis related to metallic debris. In: Sedel L., and Cabanela M.E. (Eds). Hip surgery: materials and developments (1998), Martin Dunitz, London 333-340
-
(1998)
Hip surgery: materials and developments
, pp. 333-340
-
-
Salvati, E.A.1
Gomez-Barrena, E.2
-
27
-
-
33645090218
-
Metallic shedding, surface finish changes, and extensive femoral osteolysis in the loose Spectron EF stem
-
Gonzalez Della Valle A., Rana A., Nestor B., Bostrom M., Westrich G., and Salvati E.A. Metallic shedding, surface finish changes, and extensive femoral osteolysis in the loose Spectron EF stem. Clin Orthop Related Res 442 (2006) 165-170
-
(2006)
Clin Orthop Related Res
, vol.442
, pp. 165-170
-
-
Gonzalez Della Valle, A.1
Rana, A.2
Nestor, B.3
Bostrom, M.4
Westrich, G.5
Salvati, E.A.6
-
28
-
-
0026534146
-
Metal levels in cemented total hip arthroplasty. A comparison of well-fixed and loose implants
-
Brien W.W., Salvati E.A., Betts F., Bullough P., Wright T., Rimnac C., et al. Metal levels in cemented total hip arthroplasty. A comparison of well-fixed and loose implants. Clin Orthop Related Res 276 (1992) 66-74
-
(1992)
Clin Orthop Related Res
, vol.276
, pp. 66-74
-
-
Brien, W.W.1
Salvati, E.A.2
Betts, F.3
Bullough, P.4
Wright, T.5
Rimnac, C.6
-
30
-
-
0035259085
-
Cutaneous metal sensitivity in patients with orthopaedic injuries
-
Swiontkowski M.F., Agel J., Schwappach J., McNair P., and Welch M. Cutaneous metal sensitivity in patients with orthopaedic injuries. J Orthop Trauma 15 (2001) 86-89
-
(2001)
J Orthop Trauma
, vol.15
, pp. 86-89
-
-
Swiontkowski, M.F.1
Agel, J.2
Schwappach, J.3
McNair, P.4
Welch, M.5
-
31
-
-
0005059996
-
The properties and clinical uses of cobalt-chromium alloys
-
CRC Press, Boca Raton, FL
-
Williams D.F. The properties and clinical uses of cobalt-chromium alloys. Biocompatibility of Clinical Materials vol. I (1981), CRC Press, Boca Raton, FL 99-123
-
(1981)
Biocompatibility of Clinical Materials
, vol.I
, pp. 99-123
-
-
Williams, D.F.1
-
32
-
-
41549161504
-
-
Asphahani AI. Corrosion of cobalt base alloys. In: ASM Metals Handbook. (9th ed.) vol. 13. Corrosion. Metals Park, OH: ASM International; 1987. p. 658-68.
-
Asphahani AI. Corrosion of cobalt base alloys. In: ASM Metals Handbook. (9th ed.) vol. 13. Corrosion. Metals Park, OH: ASM International; 1987. p. 658-68.
-
-
-
-
33
-
-
84863796131
-
Cobalt alloys
-
Revie R.W. (Ed), Wiley Interscience, New York
-
Crook P., and Silence W.L. Cobalt alloys. In: Revie R.W. (Ed). Uhlig's corrosion handbook (2000), Wiley Interscience, New York 717-728
-
(2000)
Uhlig's corrosion handbook
, pp. 717-728
-
-
Crook, P.1
Silence, W.L.2
-
34
-
-
29244474600
-
Late fatigue fracture of a modern cemented forged cobalt chrome stem for total hip arthroplasty: a report of 10 cases
-
Della Valle A.G., Becksac B., Anderson J., Wright T., Nestor B., Pellicci P.M., et al. Late fatigue fracture of a modern cemented forged cobalt chrome stem for total hip arthroplasty: a report of 10 cases. J Arthroplasty 20 (2005) 1084-1088
-
(2005)
J Arthroplasty
, vol.20
, pp. 1084-1088
-
-
Della Valle, A.G.1
Becksac, B.2
Anderson, J.3
Wright, T.4
Nestor, B.5
Pellicci, P.M.6
-
35
-
-
3543014272
-
The corrosion properties of titanium and titanium alloys
-
Brunette D.M., Tengvall P., Textor M., and Thoms P. (Eds), Springer-Verlag, Berlin
-
Schenk R. The corrosion properties of titanium and titanium alloys. In: Brunette D.M., Tengvall P., Textor M., and Thoms P. (Eds). Titanium in Medicine (2001), Springer-Verlag, Berlin 145-170
-
(2001)
Titanium in Medicine
, pp. 145-170
-
-
Schenk, R.1
-
36
-
-
0028118588
-
Electrochemical and XPS studies of titanium for biomaterial applications with respect to the effect of hydrogen-peroxide
-
Pan J., Thierry D., and Leygraf C. Electrochemical and XPS studies of titanium for biomaterial applications with respect to the effect of hydrogen-peroxide. J Biomed Mater Res 28 (1994) 113-122
-
(1994)
J Biomed Mater Res
, vol.28
, pp. 113-122
-
-
Pan, J.1
Thierry, D.2
Leygraf, C.3
-
37
-
-
0030141235
-
Electrochemcial impedance spectroscopy study of the passive oxide film on titanium for implant application
-
Pan J., Thierry D., and Leygraf C. Electrochemcial impedance spectroscopy study of the passive oxide film on titanium for implant application. Electrochim Acta 41 (1996) 1143-1153
-
(1996)
Electrochim Acta
, vol.41
, pp. 1143-1153
-
-
Pan, J.1
Thierry, D.2
Leygraf, C.3
-
38
-
-
28544446416
-
-
Ruzickova M, Hildebrand, H, Virtanen S. Z Phys Chem 2005;219:1447-59.
-
Ruzickova M, Hildebrand, H, Virtanen S. Z Phys Chem 2005;219:1447-59.
-
-
-
-
39
-
-
0026641070
-
Titanium wear debris in failed cemented total hip arthroplasty. An analysis of 71 cases
-
Buly R.L., Huo M.H., Salvati E., Brien W., and Bansal M. Titanium wear debris in failed cemented total hip arthroplasty. An analysis of 71 cases. J Arthroplasty 7 (1992) 315-323
-
(1992)
J Arthroplasty
, vol.7
, pp. 315-323
-
-
Buly, R.L.1
Huo, M.H.2
Salvati, E.3
Brien, W.4
Bansal, M.5
-
40
-
-
0028321408
-
Particulate titanium and cobalt-chrome metallic debris in failed total knee arthroplasty. A quantitative histologic analysis
-
La Budde J.K., Orosz J.F., Bonfiglio T.A., and Pellegrini Jr. V.D. Particulate titanium and cobalt-chrome metallic debris in failed total knee arthroplasty. A quantitative histologic analysis. J Arthroplasty 9 (1994) 291-304
-
(1994)
J Arthroplasty
, vol.9
, pp. 291-304
-
-
La Budde, J.K.1
Orosz, J.F.2
Bonfiglio, T.A.3
Pellegrini Jr., V.D.4
-
42
-
-
41549130761
-
-
Zsklarska-Smialowska Z. Pitting corrosion of metals. Houston, TX: National Association of Corrosion Engineers; 1986.
-
Zsklarska-Smialowska Z. Pitting corrosion of metals. Houston, TX: National Association of Corrosion Engineers; 1986.
-
-
-
-
43
-
-
1342264209
-
Passive and transpassive behaviour of CoCrMo in simulated biological solutions
-
Hodgson A.W.E., Kurz S., Virtanen S., Fervel V., Olsson C.O.A., and Mischler S. Passive and transpassive behaviour of CoCrMo in simulated biological solutions. Electrochim Acta 49 (2004) 2167-2178
-
(2004)
Electrochim Acta
, vol.49
, pp. 2167-2178
-
-
Hodgson, A.W.E.1
Kurz, S.2
Virtanen, S.3
Fervel, V.4
Olsson, C.O.A.5
Mischler, S.6
-
44
-
-
3242706859
-
The effect of temperature on the nucleation of corrosion pits on titanium in Ringer's physiological solution
-
Burstein G.T., Liu C., and Souto R.M. The effect of temperature on the nucleation of corrosion pits on titanium in Ringer's physiological solution. Biomaterials 26 (2005) 245-256
-
(2005)
Biomaterials
, vol.26
, pp. 245-256
-
-
Burstein, G.T.1
Liu, C.2
Souto, R.M.3
-
45
-
-
4043144486
-
Metastable and stable pitting corrosion of titanium in halide solutions
-
Virtanen S., and Curty C. Metastable and stable pitting corrosion of titanium in halide solutions. Corrosion (2004) 60643-60649
-
(2004)
Corrosion
, pp. 60643-60649
-
-
Virtanen, S.1
Curty, C.2
-
46
-
-
0000839574
-
Observations of localized instability of passive titanium in chloride solution
-
Burstein G.T., and Souto R.M. Observations of localized instability of passive titanium in chloride solution. Electrochim Acta 40 (1995) 1881-1888
-
(1995)
Electrochim Acta
, vol.40
, pp. 1881-1888
-
-
Burstein, G.T.1
Souto, R.M.2
-
47
-
-
0030175875
-
A preliminary investigation into the microscopic depassivation of passive titanium implant materials in vitro
-
Souto R.M., and Burstein G.T. A preliminary investigation into the microscopic depassivation of passive titanium implant materials in vitro. J Mater Sci Mater Medicine 7 (1996) 337-343
-
(1996)
J Mater Sci Mater Medicine
, vol.7
, pp. 337-343
-
-
Souto, R.M.1
Burstein, G.T.2
-
49
-
-
0021817608
-
An electrochemical investigation of localized corrosion on titanium in chloride environments
-
Mickay P., and Mitton D.B. An electrochemical investigation of localized corrosion on titanium in chloride environments. Corrosion 41 (1985) 52-62
-
(1985)
Corrosion
, vol.41
, pp. 52-62
-
-
Mickay, P.1
Mitton, D.B.2
-
50
-
-
41549120984
-
-
Schutz RW, Thomas DE. Corrosion of titanium and titanium alloys. In: Metals handbook (9th ed.) vol. 13. Metals Park, OH: ASM International; 1987. p. 669-706.
-
Schutz RW, Thomas DE. Corrosion of titanium and titanium alloys. In: Metals handbook (9th ed.) vol. 13. Metals Park, OH: ASM International; 1987. p. 669-706.
-
-
-
-
51
-
-
0029257098
-
Fretting corrosion accelerates crevice corrosion of modular hip tapers
-
Brown S.A., Flemming C.A., Kawalec J.S., Placko H.E., Vassaux C., Merritt K., et al. Fretting corrosion accelerates crevice corrosion of modular hip tapers. J Appl Biomater 6 (1995) 19-26
-
(1995)
J Appl Biomater
, vol.6
, pp. 19-26
-
-
Brown, S.A.1
Flemming, C.A.2
Kawalec, J.S.3
Placko, H.E.4
Vassaux, C.5
Merritt, K.6
-
52
-
-
0027897650
-
In vivo corrosion of modular hip prosthesis components in mixed and similar metal combination. The effect of crevice, stress, motion and alloy coupling
-
Gilbert J.L., Buckley C.A., and Jacobs J.J. In vivo corrosion of modular hip prosthesis components in mixed and similar metal combination. The effect of crevice, stress, motion and alloy coupling. J Biomed Mat Res 27 (1993) 1533-1544
-
(1993)
J Biomed Mat Res
, vol.27
, pp. 1533-1544
-
-
Gilbert, J.L.1
Buckley, C.A.2
Jacobs, J.J.3
-
53
-
-
0033118784
-
Conjoint corrosion and wear in titanium alloys
-
Khan M.A., Williams R.L., and Williams D.F. Conjoint corrosion and wear in titanium alloys. Biomaterials 20 (1999) 765-772
-
(1999)
Biomaterials
, vol.20
, pp. 765-772
-
-
Khan, M.A.1
Williams, R.L.2
Williams, D.F.3
-
54
-
-
0037499588
-
Investigation into wear-induced corrosion of orthopedic implant materials
-
Winters G.L., and Nutt M.J. (Eds), ASTM International, West Conschohocken
-
Windler M., MacDougall J.E., and Schenk R. Investigation into wear-induced corrosion of orthopedic implant materials. In: Winters G.L., and Nutt M.J. (Eds). Stainless steels for medical and surgical applications (2003), ASTM International, West Conschohocken 211-221
-
(2003)
Stainless steels for medical and surgical applications
, pp. 211-221
-
-
Windler, M.1
MacDougall, J.E.2
Schenk, R.3
-
55
-
-
1842787388
-
Environmental effect on fretting of metallic materials for orthopaedic implants
-
Duisabeau L., Combrade P., and Forest B. Environmental effect on fretting of metallic materials for orthopaedic implants. Wear 256 (2004) 805-816
-
(2004)
Wear
, vol.256
, pp. 805-816
-
-
Duisabeau, L.1
Combrade, P.2
Forest, B.3
-
56
-
-
23044455858
-
Electrochemical effects on the fretting corrosion behaviour of Ti6Al4V in 0.9% sodium chloride solution
-
Barril S., Mischler S., and Landolt D. Electrochemical effects on the fretting corrosion behaviour of Ti6Al4V in 0.9% sodium chloride solution. Wear 259 (2005) 282-291
-
(2005)
Wear
, vol.259
, pp. 282-291
-
-
Barril, S.1
Mischler, S.2
Landolt, D.3
-
57
-
-
0030298058
-
In-vitro corrosion and wear of titanium alloys in the biological environment
-
Khan M.A., Williams R.L., and Williams D.F. In-vitro corrosion and wear of titanium alloys in the biological environment. Biomaterials 17 (1996) 2117-2126
-
(1996)
Biomaterials
, vol.17
, pp. 2117-2126
-
-
Khan, M.A.1
Williams, R.L.2
Williams, D.F.3
-
58
-
-
0031555492
-
Electrochemical response of CoCrMo to high-speed fracture of its metal oxide using an electrochemical scratch test method
-
Goldberg J.R., and Gilbert J.L. Electrochemical response of CoCrMo to high-speed fracture of its metal oxide using an electrochemical scratch test method. J Biomed Mater Res 37 (1997) 421-431
-
(1997)
J Biomed Mater Res
, vol.37
, pp. 421-431
-
-
Goldberg, J.R.1
Gilbert, J.L.2
-
59
-
-
0032527072
-
Repassivation of titanium and surface oxide film regenerated in simulated bioliquid
-
Hanawa T., Asami K., and Asaoka K. Repassivation of titanium and surface oxide film regenerated in simulated bioliquid. J Biomed Mat Res 40 (1998) 530-538
-
(1998)
J Biomed Mat Res
, vol.40
, pp. 530-538
-
-
Hanawa, T.1
Asami, K.2
Asaoka, K.3
-
60
-
-
33750363656
-
Hip implants - paper VI - ion concentrations
-
Sargeant A., and Goswami T. Hip implants - paper VI - ion concentrations. Mater Design 28 (2007) 155-171
-
(2007)
Mater Design
, vol.28
, pp. 155-171
-
-
Sargeant, A.1
Goswami, T.2
-
61
-
-
9444243222
-
Metal ion release from metal implants
-
Hanawa T. Metal ion release from metal implants. Mater Sci Eng C24 (2004) 745-752
-
(2004)
Mater Sci Eng
, vol.C24
, pp. 745-752
-
-
Hanawa, T.1
-
62
-
-
2942613210
-
Comparison of metal release from various metallic biomaterials in vitro
-
Okazaki Y., and Gotoh E. Comparison of metal release from various metallic biomaterials in vitro. Biomaterials 26 (2005) 11-21
-
(2005)
Biomaterials
, vol.26
, pp. 11-21
-
-
Okazaki, Y.1
Gotoh, E.2
-
63
-
-
2942604622
-
Comparison of metal concentrations in rat tibia tissues with various metallic implants
-
Okazaki Y., Gotoh E., Manabe T., and Kobayashi K. Comparison of metal concentrations in rat tibia tissues with various metallic implants. Biomaterials 25 (2004) 5913-5920
-
(2004)
Biomaterials
, vol.25
, pp. 5913-5920
-
-
Okazaki, Y.1
Gotoh, E.2
Manabe, T.3
Kobayashi, K.4
-
64
-
-
0028999336
-
Release of hexavalent chromium from corrosion of stainless steel and cobalt-chromium alloys
-
Merritt K., and Brown S.A. Release of hexavalent chromium from corrosion of stainless steel and cobalt-chromium alloys. J Biomed Mat Res 29 (1995) 627-633
-
(1995)
J Biomed Mat Res
, vol.29
, pp. 627-633
-
-
Merritt, K.1
Brown, S.A.2
-
65
-
-
27244459144
-
Metal-specific differences in levels of DNA damage caused by synovial fluid recovered at revision arthroplasty
-
Davies A.P., Sood A., Lewis A.C., Newson R., Learmonth I.D., and Case C.P. Metal-specific differences in levels of DNA damage caused by synovial fluid recovered at revision arthroplasty. J Bone Joint Surg Br 87-B (2005) 1439-1444
-
(2005)
J Bone Joint Surg Br
, vol.87 -B
, pp. 1439-1444
-
-
Davies, A.P.1
Sood, A.2
Lewis, A.C.3
Newson, R.4
Learmonth, I.D.5
Case, C.P.6
-
66
-
-
0242490794
-
Serum cobalt levels after metal-on-metal total hip arthroplasty
-
Brodner W., Bitzan P., Meisinger V., Kaider A., Gottsauner-Wolf F., and Kotz R. Serum cobalt levels after metal-on-metal total hip arthroplasty. J Bone Joint Surg Am 85-A (2003) 2168-2173
-
(2003)
J Bone Joint Surg Am
, vol.85 -A
, pp. 2168-2173
-
-
Brodner, W.1
Bitzan, P.2
Meisinger, V.3
Kaider, A.4
Gottsauner-Wolf, F.5
Kotz, R.6
-
67
-
-
0037224605
-
Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements
-
Lhotka C., Szekeres T., Steffan I., Zhuber K., and Zweymuller K. Four-year study of cobalt and chromium blood levels in patients managed with two different metal-on-metal total hip replacements. J Orthop Res 21 (2003) 189-195
-
(2003)
J Orthop Res
, vol.21
, pp. 189-195
-
-
Lhotka, C.1
Szekeres, T.2
Steffan, I.3
Zhuber, K.4
Zweymuller, K.5
-
68
-
-
3343005244
-
Massive wear of an incompatible metal-on-metal articulation in total hip arthroplasty
-
Keel J.B., and Kuster M.S. Massive wear of an incompatible metal-on-metal articulation in total hip arthroplasty. J Arthroplasty 19 (2004) 638-642
-
(2004)
J Arthroplasty
, vol.19
, pp. 638-642
-
-
Keel, J.B.1
Kuster, M.S.2
-
69
-
-
0016533311
-
The use of dissimilar metals in surgery
-
Mears D.C. The use of dissimilar metals in surgery. J Biomed Mat Res 6 (1975) 133-148
-
(1975)
J Biomed Mat Res
, vol.6
, pp. 133-148
-
-
Mears, D.C.1
-
70
-
-
41549147227
-
-
Mansfeld F, Lee CC, Kovacs P. Application of electrochemical impedance spectroscopy (EIS) to the evaluation of the corrosion behavior of implant materials. In: Kovacs P, Istephanous NS, editors. Compatibility of biomedical implants, Pennington, NJ: The Electrochemical Society; 1994. p. 59-72.
-
Mansfeld F, Lee CC, Kovacs P. Application of electrochemical impedance spectroscopy (EIS) to the evaluation of the corrosion behavior of implant materials. In: Kovacs P, Istephanous NS, editors. Compatibility of biomedical implants, Pennington, NJ: The Electrochemical Society; 1994. p. 59-72.
-
-
-
-
71
-
-
0028030881
-
The contribution of metallic debris to osteolysis
-
Salvati E.A., and Gomez Barrena E. The contribution of metallic debris to osteolysis. Orthopedics 17 (1994) 763-765
-
(1994)
Orthopedics
, vol.17
, pp. 763-765
-
-
Salvati, E.A.1
Gomez Barrena, E.2
-
72
-
-
0028197402
-
An analysis of the head-neck taper interface in retrieved hip prostheses
-
Lieberman J.R., Rimnac C.M., Garvin K.L., Klein R.W., and Salvati E.A. An analysis of the head-neck taper interface in retrieved hip prostheses. Clin Orthop Related Res 300 (1994) 162-167
-
(1994)
Clin Orthop Related Res
, vol.300
, pp. 162-167
-
-
Lieberman, J.R.1
Rimnac, C.M.2
Garvin, K.L.3
Klein, R.W.4
Salvati, E.A.5
-
73
-
-
0030048534
-
Corrosion at the interface. A possible solution to cobalt-chrome heads on titanium alloy stems
-
Yerby S.A., Taylor J.K., Park J., and Shackelford J.F. Corrosion at the interface. A possible solution to cobalt-chrome heads on titanium alloy stems. J Arthroplasty 11 (1996) 157-162
-
(1996)
J Arthroplasty
, vol.11
, pp. 157-162
-
-
Yerby, S.A.1
Taylor, J.K.2
Park, J.3
Shackelford, J.F.4
-
74
-
-
0035989725
-
Pitting, crevice and galvanic corrosion of REX stainless-steel/CoCr orthopedic implant material
-
Reclaru L., Lerf R., Eschler P.-Y., Blatter A., and Meyer J.-M. Pitting, crevice and galvanic corrosion of REX stainless-steel/CoCr orthopedic implant material. Biomaterials 23 (2002) 3479-3485
-
(2002)
Biomaterials
, vol.23
, pp. 3479-3485
-
-
Reclaru, L.1
Lerf, R.2
Eschler, P.-Y.3
Blatter, A.4
Meyer, J.-M.5
-
75
-
-
3342989317
-
Is galvanic corrosion between titanium alloy and stainless steel spinal implant a clinical concern?
-
Serhan H., Slivka M., Albert T., and Kwak S.D. Is galvanic corrosion between titanium alloy and stainless steel spinal implant a clinical concern?. The Spine Journal 4 (2004) 379-387
-
(2004)
The Spine Journal
, vol.4
, pp. 379-387
-
-
Serhan, H.1
Slivka, M.2
Albert, T.3
Kwak, S.D.4
|