-
1
-
-
0030453223
-
Crevice corrosion of cemented titanium alloy stems in total hip replacements
-
Willert, H.-G., Brobäck, L.-G., Buchhorn, G.H., Jensen, P.H., Köster, G., Lang, I., Ochsner, P., and Schenk, R., "Crevice Corrosion of Cemented Titanium Alloy Stems in Total Hip Replacements," Clinical Orthopaedics and Related Research, No. 333, 1996, pp. 51-75.
-
(1996)
Clinical Orthopaedics and Related Research
, vol.333
, pp. 51-75
-
-
Willert, H.-G.1
Brobäck, L.-G.2
Buchhorn, G.H.3
Jensen, P.H.4
Köster, G.5
Lang, I.6
Ochsner, P.7
Schenk, R.8
-
2
-
-
0027897650
-
In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling
-
Gilbert, J.L., Buckley, C.A., and Jacobs J.J., "In Vivo Corrosion of Modular Hip Prosthesis Components in Mixed and Similar Metal Combinations. The Effect of Crevice, Stress, Motion, and Alloy Coupling," J. Biomedical Materials Research, Vol. 27, 1993, pp.1533-1544.
-
(1993)
J. Biomedical Materials Research
, vol.27
, pp. 1533-1544
-
-
Gilbert, J.L.1
Buckley, C.A.2
Jacobs, J.J.3
-
3
-
-
0029257098
-
Fretting corrosion accelerates crevice corrosion of modular hip tapers
-
Brown, S.A., Flemming, C.A.C., Kawalec, J.S., Placko, H.E., Vassaux, C., Merritt, K., Payer, J.H., and Kraay, M.J., "Fretting Corrosion Accelerates Crevice Corrosion of Modular Hip Tapers," J. Applied Biomaterials, Vol. 6, 1995, pp. 19-26.
-
(1995)
J. Applied Biomaterials
, vol.6
, pp. 19-26
-
-
Brown, S.A.1
Flemming, C.A.C.2
Kawalec, J.S.3
Placko, H.E.4
Vassaux, C.5
Merritt, K.6
Payer, J.H.7
Kraay, M.J.8
-
4
-
-
0026671808
-
Interface corrosion of a modular head total hip prosthesis
-
McKellop, H.A., Sarmiento, A., Brien, W., Park, S.H., "Interface Corrosion of a Modular Head Total Hip Prosthesis," J. Arthroplasty, Vol. 7, 1992, pp. 291-294.
-
(1992)
J. Arthroplasty
, vol.7
, pp. 291-294
-
-
McKellop, H.A.1
Sarmiento, A.2
Brien, W.3
Park, S.H.4
-
5
-
-
0029790390
-
Mechanical effects of stem cement interface characteristics in total hip replacement
-
Verdonschot, N., and Huiskes, R., "Mechanical Effects of Stem Cement Interface Characteristics in Total Hip Replacement," Clinical Orthopaedics and Related Research, No. 329, 1996, pp. 326-336.
-
(1996)
Clinical Orthopaedics and Related Research
, vol.329
, pp. 326-336
-
-
Verdonschot, N.1
Huiskes, R.2
-
6
-
-
0038787510
-
Fretting wear of titanium and cobalt-chromium alloys against bone-cement
-
New Orleans, March
-
Wimmer, M.A., Bluhm, A., Kunze, J., Heckel, L., Morlock, M.M., and Schneider, E., "Fretting Wear of Titanium and Cobalt-Chromium Alloys against Bone-Cement," Proceedings of 44th Annual Meeting of the Orthopaedic Research Society, New Orleans, March 1998, p. 353.
-
(1998)
Proceedings of 44th Annual Meeting of the Orthopaedic Research Society
, pp. 353
-
-
Wimmer, M.A.1
Bluhm, A.2
Kunze, J.3
Heckel, L.4
Morlock, M.M.5
Schneider, E.6
-
7
-
-
0028329588
-
Fretting deterioration of orthopaedic implant materials: Search for solutions
-
Rabbe, L.M., Rieu, J., Lopez, A., and Combrade, P., "Fretting Deterioration of Orthopaedic Implant Materials: Search for solutions," Clinical Materials, 15, 1994, pp. 221-226.
-
(1994)
Clinical Materials
, vol.15
, pp. 221-226
-
-
Rabbe, L.M.1
Rieu, J.2
Lopez, A.3
Combrade, P.4
-
8
-
-
0029839935
-
Characterisation and comparison of wear debris from failed total hip implants of different types
-
Hirakawa, K., Bauer, T.W., Stulberg, B.N., Wilde, A.H., and Secic, M, "Characterisation and Comparison of Wear Debris from Failed Total Hip Implants of Different Types," J. Bone and Joint Surgery, Vol. 78A, 1996, pp. 1235-1243.
-
(1996)
J. Bone and Joint Surgery
, vol.78 A
, pp. 1235-1243
-
-
Hirakawa, K.1
Bauer, T.W.2
Stulberg, B.N.3
Wilde, A.H.4
Secic, M.5
-
9
-
-
0003251758
-
In-Vivo tribological performance of 177 metal-on-metal hip articulations
-
C. Rieker, S. Oberholzer and U. Wyss, Eds., Huber Verlag, Bern
-
Rieker, C., Shen, M., and Köttig, P., "In-Vivo Tribological Performance of 177 Metal-on-Metal Hip Articulations," World Tribology Forum in Arthroplasty, C. Rieker, S. Oberholzer and U. Wyss, Eds., Huber Verlag, Bern, 2001, pp. 137-142.
-
(2001)
World Tribology Forum in Arthroplasty
, pp. 137-142
-
-
Rieker, C.1
Shen, M.2
Köttig, P.3
-
10
-
-
0002848362
-
Fretting corrosion of plates and screws: An in vitro test method
-
ASTM STP 859, A.C. Fraker and C.D. Griffin, Eds., ASTM International, West Conshohocken, PA
-
Brown, S.A., and Merritt, K., "Fretting Corrosion of Plates and Screws: An In Vitro Test Method," Corrosion and Degradation of Implant Materials, ASTM STP 859, A.C. Fraker and C.D. Griffin, Eds., ASTM International, West Conshohocken, PA, 1985, pp. 117-135.
-
(1985)
Corrosion and Degradation of Implant Materials
, pp. 117-135
-
-
Brown, S.A.1
Merritt, K.2
-
11
-
-
0008413617
-
Corrosion of implant alloys
-
G.H. Buchhom and H.G. Willert, Eds., Hogrefe & Huber Publishers
-
Steinemann, S.G., "Corrosion of Implant Alloys," Technical Principles, Design and Safety of Joint Implants, G.H. Buchhom and H.G. Willert, Eds., Hogrefe & Huber Publishers, 1994, pp. 168-179.
-
(1994)
Technical Principles, Design and Safety of Joint Implants
, pp. 168-179
-
-
Steinemann, S.G.1
-
12
-
-
0030143195
-
Titanium oxide film fracture and repassivation: The effect of potential, pH and aeration
-
ASTM STP 1272, S.A. Brown and I.E. Lemons, Eds., Philadelphia
-
Gilbert, J.L., Buckley, C.A., and Lautenschlager, E.P., "Titanium Oxide Film Fracture and Repassivation: The Effect of Potential, pH and Aeration," Medical Applications of Titanium and Its Alloys: The Material and Biological Issues, ASTM STP 1272, S.A. Brown and I.E. Lemons, Eds., Philadelphia, 1996, pp. 199-215.
-
(1996)
Medical Applications of Titanium and Its Alloys: The Material and Biological Issues
, pp. 199-215
-
-
Gilbert, J.L.1
Buckley, C.A.2
Lautenschlager, E.P.3
|