메뉴 건너뛰기




Volumn 11, Issue 2, 1996, Pages 157-162

Corrosion at the interface: A possible solution to cobalt-chrome heads on titanium alloy stems

Author keywords

cobalt chrome; corrosion; modular head; titanium; total hip arthroplasty

Indexed keywords

ALLOY; CHROMIUM; COBALT; TITANIUM;

EID: 0030048534     PISSN: 08835403     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0883-5403(05)80010-5     Document Type: Article
Times cited : (9)

References (11)
  • 1
    • 0026326833 scopus 로고
    • Corrosion at the interface of cobalt-alloy heads on titanium-alloy stems
    • Collier JP, Surprenant VA, Jensen RE, Mayor MB: Corrosion at the interface of cobalt-alloy heads on titanium-alloy stems. Clin Orthop 271:305, 1991
    • (1991) Clin Orthop , vol.271 , pp. 305
    • Collier, J.P.1    Surprenant, V.A.2    Jensen, R.E.3    Mayor, M.B.4
  • 2
    • 0026773329 scopus 로고
    • Corrosion between the components of modular femoral hip prostheses
    • Collier JP, Surprenant VA, Jensen RE et al: Corrosion between the components of modular femoral hip prostheses. J Bone Joint Surg 74B:511, 1992
    • (1992) J Bone Joint Surg , vol.74 B , pp. 511
    • Collier, J.P.1    Surprenant, V.A.2    Jensen, R.E.3
  • 3
    • 0028063951 scopus 로고
    • Corrosion and wear at the modular interface of uncemented femoral stems
    • Cook SD, Barrak RL, Clemow AJT: Corrosion and wear at the modular interface of uncemented femoral stems. J Bone Joint Surg 76B:68, 1994
    • (1994) J Bone Joint Surg , vol.76 B , pp. 68
    • Cook, S.D.1    Barrak, R.L.2    Clemow, A.J.T.3
  • 6
    • 0016533455 scopus 로고
    • 3 ceramic joint replacement: Experimental results and design considerations for human endoprostheses
    • 3 ceramic joint replacement: experimental results and design considerations for human endoprostheses. J Biomed Mater Res 9:177, 1975
    • (1975) J Biomed Mater Res , vol.9 , pp. 177
    • Griss, P.1    Heimke, G.2    Von Andiran-Werburg, H.3
  • 7
    • 0017642464 scopus 로고
    • Assorted aluminum-oxide ceramic heads for prostheses of the hip-joint: A preliminary communication
    • Weber BG, Frey O, Semlitsch M, Dorre E: Assorted aluminum-oxide ceramic heads for prostheses of the hip-joint: a preliminary communication. Z Orthop 115:305, 1977
    • (1977) Z Orthop , vol.115 , pp. 305
    • Weber, B.G.1    Frey, O.2    Semlitsch, M.3    Dorre, E.4
  • 8
    • 0017644605 scopus 로고
    • A metal-ceramic composite endoprosthesis for total hip replacement
    • Zweymuller K, Zhuber K, Locke H: A metal-ceramic composite endoprosthesis for total hip replacement. Wien Klin Wochenschr 89:548, 1977
    • (1977) Wien Klin Wochenschr , vol.89 , pp. 548
    • Zweymuller, K.1    Zhuber, K.2    Locke, H.3
  • 9
    • 0018034892 scopus 로고
    • Evaluation of couple/crevice corrosion by prosthetic alloys under in vivo conditions
    • Rostoker W, Galante JO, Lereim P: Evaluation of couple/crevice corrosion by prosthetic alloys under in vivo conditions. J Biomed Mater Res 12:823, 1978
    • (1978) J Biomed Mater Res , vol.12 , pp. 823
    • Rostoker, W.1    Galante, J.O.2    Lereim, P.3
  • 10
    • 0028001457 scopus 로고
    • Widespread dissemination of metal debris from implants
    • Case CP, Langkamer VG, James C et al: Widespread dissemination of metal debris from implants. J Bone Joint Surg 76B:701, 1994
    • (1994) J Bone Joint Surg , vol.76 B , pp. 701
    • Case, C.P.1    Langkamer, V.G.2    James, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.