-
1
-
-
0342510143
-
The revision problem
-
(Eds R. N. Villar, A. E. Gross and D. McMinn) Reed Educational and Professional Publishing Limited, Bath
-
Gross, A. E. The revision problem. In Revision Hip Arthroplasty: A Practical Approach to Bone Stock Loss (Eds R. N. Villar, A. E. Gross and D. McMinn), 1997 (Reed Educational and Professional Publishing Limited, Bath), pp. 1-3.
-
(1997)
Revision Hip Arthroplasty: A Practical Approach to Bone Stock Loss
, pp. 1-3
-
-
Gross, A.E.1
-
2
-
-
84871437218
-
Particle disease
-
(Eds R. N. Villar, A. E. Gross and D. McMinn) Reed Educational and Professional Publishing Limited, Bath
-
Howie, D. W. Particle disease. In Revision Hip Arthroplasty: A Practical Approach to Bone Stock Loss (Eds R. N. Villar, A. E. Gross and D. McMinn), 1997 (Reed Educational and Professional Publishing Limited, Bath), pp. 4-11.
-
(1997)
Revision Hip Arthroplasty: A Practical Approach to Bone Stock Loss
, pp. 4-11
-
-
Howie, D.W.1
-
3
-
-
0029050610
-
Loss of bone stock with cementless hip arthroplasty
-
Learmonth, I. D., Grobler, G. P., Dall, D. M. and Jandera, V. Loss of bone stock with cementless hip arthroplasty. J. Arthroplasty, 1995, 10(3), 257-263.
-
(1995)
J. Arthroplasty
, vol.10
, Issue.3
, pp. 257-263
-
-
Learmonth, I.D.1
Grobler, G.P.2
Dall, D.M.3
Jandera, V.4
-
4
-
-
0021734867
-
Bone grafting in total hip replacement
-
Slooff, T. J. J. H., Huiskes, R., van Horn, J. and Lemmens, A. J. Bone grafting in total hip replacement. Acta Orthop. Scand., 1984, 65, 593-596.
-
(1984)
Acta Orthop. Scand.
, vol.65
, pp. 593-596
-
-
Slooff, T.J.J.H.1
Huiskes, R.2
van Horn, J.3
Lemmens, A.J.4
-
5
-
-
0027382133
-
Contained morselized allograft in revision total hip arthroplasty. Surgical technique
-
Gie, G. A., Linder, L., Ling, R. S., Simon, J. P., Slooff, T. J. and Timperley, A. J. Contained morselized allograft in revision total hip arthroplasty. Surgical technique. Orthop. Clinics North Am., 1993, 24(4), 717-725.
-
(1993)
Orthop. Clinics North Am.
, vol.24
, Issue.4
, pp. 717-725
-
-
Gie, G.A.1
Linder, L.2
Ling, R.S.3
Simon, J.P.4
Slooff, T.J.5
Timperley, A.J.6
-
6
-
-
0028522192
-
Femoral reconstruction with morselized bone graft and cemented stem
-
Ling, R. S. Femoral reconstruction with morselized bone graft and cemented stem. Chir. Organi Movemento, 1994, 79(4), 305-311.
-
(1994)
Chir. Organi Movemento
, vol.79
, Issue.4
, pp. 305-311
-
-
Ling, R.S.1
-
7
-
-
0031961240
-
Acetabular reconstruction with impacted morsellised cancellous bone graft and cement. A 10 to 15 year follow up of 60 revision arthroplasties
-
Schreurs, B. W., Slooff, T. J., Buma, P., Gardeniers, J. W. and Huiskes, R. Acetabular reconstruction with impacted morsellised cancellous bone graft and cement. A 10 to 15 year follow up of 60 revision arthroplasties. J. Bone Jt Surg., 1998, 80B(3), 391-395.
-
(1998)
J. Bone Jt Surg.
, vol.80 B
, Issue.3
, pp. 391-395
-
-
Schreurs, B.W.1
Slooff, T.J.2
Buma, P.3
Gardeniers, J.W.4
Huiskes, R.5
-
8
-
-
0034067230
-
Cemented total hip arthroplasty with acetabular bone graft for developmental dysplasia. Long term results and survivorship analysis
-
Iida, H., Matsusue, Y., Kawanabe, K., Okumura, H., Yamamuro, T. and Nakamura, T. Cemented total hip arthroplasty with acetabular bone graft for developmental dysplasia. Long term results and survivorship analysis. J. Bone Jt Surg., 2000, 82B(2), 176-184.
-
(2000)
J. Bone Jt Surg.
, vol.82 B
, Issue.2
, pp. 176-184
-
-
Iida, H.1
Matsusue, Y.2
Kawanabe, K.3
Okumura, H.4
Yamamuro, T.5
Nakamura, T.6
-
9
-
-
0034097722
-
Cemented total hip arthroplasty with autogenous acetabular bone grafting for hips with acetabular bone graft for developmental dysplasia in adults: The results at a minimum of ten years
-
Inao, S. and Matsuno, T. Cemented total hip arthroplasty with autogenous acetabular bone grafting for hips with acetabular bone graft for developmental dysplasia in adults: the results at a minimum of ten years. J. Bone Jt Surg., 2000, 82B(3), 375-377.
-
(2000)
J. Bone Jt Surg.
, vol.82 B
, Issue.3
, pp. 375-377
-
-
Inao, S.1
Matsuno, T.2
-
11
-
-
0032895219
-
Mechanical considerations in impaction bone grafting
-
Brewster, N. T., Gillespie, W. J., Howie, C. R., Madabhushi, S. P. G., Usmani, A. S. and Fairbairn, D. R. Mechanical considerations in impaction bone grafting. J. Bone Jt Surg., 1999, 81B, 118-124.
-
(1999)
J. Bone Jt Surg.
, vol.81 B
, pp. 118-124
-
-
Brewster, N.T.1
Gillespie, W.J.2
Howie, C.R.3
Madabhushi, S.P.G.4
Usmani, A.S.5
Fairbairn, D.R.6
-
12
-
-
4043132534
-
Mechanical aspects of impaction grafting in THR: The effect of particle size distribution, additives and washing
-
Brussels, Belgium, 3-8 June
-
Dunlop, D. G., Howie, C. R., Pankaj, P., Madabhushi, S. P. G. and Usmani, A. S. Mechanical aspects of impaction grafting in THR: the effect of particle size distribution, additives and washing. Abstracts of Poster, EFORT (European Federation of National Associations of Orthopaedics and Traumatology), Brussels, Belgium, 3-8 June, 1999.
-
(1999)
Abstracts of Poster, EFORT (European Federation of National Associations of Orthopaedics and Traumatology)
-
-
Dunlop, D.G.1
Howie, C.R.2
Pankaj, P.3
Madabhushi, S.P.G.4
Usmani, A.S.5
-
13
-
-
0037697854
-
Mechanical strength of impaction bone grafting: The effect of washing the graft
-
Dunlop, D. G., Brewster, N. T., Madabhushi, S. P. G., Usmani, A. S., Pankaj, P. and Howie, C. R. Mechanical strength of impaction bone grafting: the effect of washing the graft. J. Bone Jt Surg., 2003, 85A, 639-646.
-
(2003)
J. Bone Jt Surg.
, vol.85 A
, pp. 639-646
-
-
Dunlop, D.G.1
Brewster, N.T.2
Madabhushi, S.P.G.3
Usmani, A.S.4
Pankaj, P.5
Howie, C.R.6
-
15
-
-
0023547272
-
Finite element analysis of acetabular reconstruction: Non cemented threaded cup
-
Huiskes, R. Finite element analysis of acetabular reconstruction: non cemented threaded cup. Acta Orthop. Scand., 1987, 58, 620-625.
-
(1987)
Acta Orthop. Scand.
, vol.58
, pp. 620-625
-
-
Huiskes, R.1
-
16
-
-
0027641060
-
Hip joint loading during walking and running measured in two patients
-
Bergmann, G., Graichen, F. and Rohlmann, A. Hip joint loading during walking and running measured in two patients. J. Biomechanics, 1993, 26, 969-990.
-
(1993)
J. Biomechanics
, vol.26
, pp. 969-990
-
-
Bergmann, G.1
Graichen, F.2
Rohlmann, A.3
-
17
-
-
0034984126
-
Hip forces and gait patterns from routine activities
-
Bergmann, G., Deuretzbacher, G., Heller, M., Graichen, F., Rohlmann, A., Strauss, J. and Duda, G. N. Hip forces and gait patterns from routine activities. J. Biomechanics, 2001, 34, 859-871.
-
(2001)
J. Biomechanics
, vol.34
, pp. 859-871
-
-
Bergmann, G.1
Deuretzbacher, G.2
Heller, M.3
Graichen, F.4
Rohlmann, A.5
Strauss, J.6
Duda, G.N.7
-
18
-
-
4043090004
-
Stresses in a highly crosslinked acetabular component for total hip replacement
-
Session 37
-
Kurtz, S., Giddings, V., Muratoglu, O., O'Connor, D., Harris, W. and Krevolin, J. Stresses in a highly crosslinked acetabular component for total hip replacement. In Hip Arthroplasty, Transactions of the 46th Annual Orthopaedic Research Society Meeting, 2000, Session 37, p. 222.
-
(2000)
Hip Arthroplasty, Transactions of the 46th Annual Orthopaedic Research Society Meeting
, pp. 222
-
-
Kurtz, S.1
Giddings, V.2
Muratoglu, O.3
O'Connor, D.4
Harris, W.5
Krevolin, J.6
-
19
-
-
4043183478
-
Mechanical behaviour of UHMWPE when mixed with vitamin E
-
Poster Session
-
Mori, A., Sakuramoto, I., Tomita, N., Kawano, S., Nagata, K., Utsumi, M., Moriya, H. and Kuramoto, K. Mechanical behaviour of UHMWPE when mixed with vitamin E. In Polyethylene, Transactions of the 47th Annual Orthopaedic Research Society Meeting, 2001, Poster Session, p. 1017.
-
(2001)
Polyethylene, Transactions of the 47th Annual Orthopaedic Research Society Meeting
, pp. 1017
-
-
Mori, A.1
Sakuramoto, I.2
Tomita, N.3
Kawano, S.4
Nagata, K.5
Utsumi, M.6
Moriya, H.7
Kuramoto, K.8
-
20
-
-
4043077150
-
A small punch test technique for characterising PMMA used in total joint replacement
-
Poster Session
-
Giddings, V., Kurtz, S., Jewett, C., Foulds, J. and Edidin, A. A small punch test technique for characterising PMMA used in total joint replacement. In Hip Arthroplasty, Transactions of the 46th Annual Orthopaedic Research Society Meeting, 2000, Poster Session, P. 509.
-
(2000)
Hip Arthroplasty, Transactions of the 46th Annual Orthopaedic Research Society Meeting
, pp. 509
-
-
Giddings, V.1
Kurtz, S.2
Jewett, C.3
Foulds, J.4
Edidin, A.5
-
21
-
-
4043139493
-
Time and storage dependent changes in mechanical properties of bone cement
-
Session 37
-
Gomoll, A. H. and Thornhill, T. S. Time and storage dependent changes in mechanical properties of bone cement. In Hip Arthroplasty, Transactions of the 46th Annual Orthopaedic Research Society Meeting, 2000, Session 37, p. 220.
-
(2000)
Hip Arthroplasty, Transactions of the 46th Annual Orthopaedic Research Society Meeting
, pp. 220
-
-
Gomoll, A.H.1
Thornhill, T.S.2
-
22
-
-
0033213751
-
Glenoid cancellous bone strength and modulus
-
Anglin, C., Tolhurst, P., Wyss, U. P. and Pichora, D. Glenoid cancellous bone strength and modulus. J. Biomechanics, 1999, 32, 1091-1097.
-
(1999)
J. Biomechanics
, vol.32
, pp. 1091-1097
-
-
Anglin, C.1
Tolhurst, P.2
Wyss, U.P.3
Pichora, D.4
-
23
-
-
0034308380
-
Critical evaluation of known bone material properties to realize anisotropic FE simulation of the proximal femur
-
Wirtz, D. C., Schiffers, N., Pandorf, T., Radermacher, K., Weichert, D. and Frost, R. Critical evaluation of known bone material properties to realize anisotropic FE simulation of the proximal femur. J. Biomechanics, 2000, 33, 1325-1330.
-
(2000)
J. Biomechanics
, vol.33
, pp. 1325-1330
-
-
Wirtz, D.C.1
Schiffers, N.2
Pandorf, T.3
Radermacher, K.4
Weichert, D.5
Frost, R.6
-
24
-
-
0033119356
-
The elastic properties of trabecular and cortical bone tissues are similar: Results from two microscopic measurement techniques
-
Turner, C. H., Rho, J., Takano, Y., Tsui, T. Y. and Pharr, G. M. The elastic properties of trabecular and cortical bone tissues are similar: results from two microscopic measurement techniques. J. Biomechanics, 1999, 32, 437-441.
-
(1999)
J. Biomechanics
, vol.32
, pp. 437-441
-
-
Turner, C.H.1
Rho, J.2
Takano, Y.3
Tsui, T.Y.4
Pharr, G.M.5
-
25
-
-
0024947002
-
Mathematical shape optimization of hip prosthesis design
-
Huiskes, R. and Boeklagen, R. Mathematical shape optimization of hip prosthesis design. J. Biomechanics, 1989, 22, 793-804.
-
(1989)
J. Biomechanics
, vol.22
, pp. 793-804
-
-
Huiskes, R.1
Boeklagen, R.2
-
26
-
-
0031970134
-
Mechanical behaviour of human morselized cancellous bone in triaxial testing
-
Brodt, M. D., Swan, C. C. and Brown, T. D. Mechanical behaviour of human morselized cancellous bone in triaxial testing. J. Orthop. Res., 1997, 16, 43-49.
-
(1997)
J. Orthop. Res.
, vol.16
, pp. 43-49
-
-
Brodt, M.D.1
Swan, C.C.2
Brown, T.D.3
-
27
-
-
0032700440
-
Mechanical characteristics of impacted morsellised bone grafts used in revision of total hip arthroplasty
-
Giesen, E. B. W., Lamerigts, N. M. P., Verdonschot, N., Buma, P., Schreurs, B. W. and Huiskes, R. Mechanical characteristics of impacted morsellised bone grafts used in revision of total hip arthroplasty. J. Bone Jt Surg., 1999, 81B(6), 1052-1057.
-
(1999)
J. Bone Jt Surg.
, vol.81 B
, Issue.6
, pp. 1052-1057
-
-
Giesen, E.B.W.1
Lamerigts, N.M.P.2
Verdonschot, N.3
Buma, P.4
Schreurs, B.W.5
Huiskes, R.6
-
28
-
-
0033371891
-
Impacted corticocancellous allografts: Recoil and strength
-
Ullmark, G. and Nilsson, O. Impacted corticocancellous allografts: recoil and strength. J. Arthroplasty, 1999, 14(8), 1019-1023.
-
(1999)
J. Arthroplasty
, vol.14
, Issue.8
, pp. 1019-1023
-
-
Ullmark, G.1
Nilsson, O.2
-
29
-
-
0033816259
-
Mechanical properties of compacted morselized cancellous bone graft using one dimensional consolidation testing
-
Voor, M. J., Nawab, A., Malkini, A. L. and Ullrich, C. R. Mechanical properties of compacted morselized cancellous bone graft using one dimensional consolidation testing. J. Biomechanics, 2000, 33, 1683-1688.
-
(2000)
J. Biomechanics
, vol.33
, pp. 1683-1688
-
-
Voor, M.J.1
Nawab, A.2
Malkini, A.L.3
Ullrich, C.R.4
-
30
-
-
0034806932
-
Time dependent mechanical properties of HA/TCP particles in relation to morsellized bone grafts for use in impaction grafting
-
Verdonschot, N., van Hal, C. T. H., Schreurs, B. W., Buma, P., Huiskes, R. and Slooff, T. J. J. H. Time dependent mechanical properties of HA/TCP particles in relation to morsellized bone grafts for use in impaction grafting. J. Biomed. Mater. Res., 2001, 58, 599-604.
-
(2001)
J. Biomed. Mater. Res.
, vol.58
, pp. 599-604
-
-
Verdonschot, N.1
van Hal, C.T.H.2
Schreurs, B.W.3
Buma, P.4
Huiskes, R.5
Slooff, T.J.J.H.6
-
33
-
-
0031550209
-
Detection of multiple active yield conditions for Mohr Coulomb elasto-plasticity
-
Pankaj and Bicanic, N. Detection of multiple active yield conditions for Mohr Coulomb elasto-plasticity. Computers Structs, 1997, 62, 51-61.
-
(1997)
Computers Structs
, vol.62
, pp. 51-61
-
-
Pankaj1
Bicanic, N.2
-
34
-
-
0008824197
-
A note on singularity indicators for Mohr Coulomb type yield criteria
-
de Borst, R., Pankaj and Bicanic, N. A note on singularity indicators for Mohr Coulomb type yield criteria. Computers Structs, 1991, 39, 219-220.
-
(1991)
Computers Structs
, vol.39
, pp. 219-220
-
-
de Borst, R.1
Pankaj2
Bicanic, N.3
-
35
-
-
0347113402
-
Tests in von Mises and isotropic Hoffmann elastoplasticity
-
Pankaj and Moin, K. Tests in von Mises and isotropic Hoffmann elastoplasticity. Engng Computations, 2000, 17, 506-540.
-
(2000)
Engng Computations
, vol.17
, pp. 506-540
-
-
Pankaj1
Moin, K.2
-
36
-
-
0021634377
-
Non-associated plasticity for soils, concrete and rock
-
Heron
-
Vermeer, P. A. and de Borst, R. Non-associated plasticity for soils, concrete and rock. Heron, 1984, 29(3), 1-64.
-
(1984)
, vol.29
, Issue.3
, pp. 1-64
-
-
Vermeer, P.A.1
de Borst, R.2
-
37
-
-
0003474658
-
-
Pineridge Press, Swansea
-
Naylor D. J., Pande, G. N., Simpson, B. and Tabb, R. Finite Elements in Geotechnical Engineering, 1981 (Pineridge Press, Swansea).
-
(1981)
Finite Elements in Geotechnical Engineering
-
-
Naylor, D.J.1
Pande, G.N.2
Simpson, B.3
Tabb, R.4
-
38
-
-
0023838466
-
Multichannel strain gauge telemetry for orthopaedic implants
-
Bergmann, G., Graichen, F., Siraky, J., Jendrzynski, H. and Rohlmann, A. Multichannel strain gauge telemetry for orthopaedic implants. J. Biomechanics, 1988, 21, 169-176.
-
(1988)
J. Biomechanics
, vol.21
, pp. 169-176
-
-
Bergmann, G.1
Graichen, F.2
Siraky, J.3
Jendrzynski, H.4
Rohlmann, A.5
-
39
-
-
0029294152
-
Is staircase walking a risk for the fixation of hip implants?
-
Bergmann, G., Graichen, F. and Rohlmann, A. Is staircase walking a risk for the fixation of hip implants? J. Biomechanics, 1995, 28, 535-553.
-
(1995)
J. Biomechanics
, vol.28
, pp. 535-553
-
-
Bergmann, G.1
Graichen, F.2
Rohlmann, A.3
-
40
-
-
0029329098
-
Influence of shoes and heel strike on the loading of the hip joint
-
Bergmann, G., Kniggendorf, H., Graichen, F. and Rohlmann, A. Influence of shoes and heel strike on the loading of the hip joint. J. Biomechanics, 1995, 28, 817-827.
-
(1995)
J. Biomechanics
, vol.28
, pp. 817-827
-
-
Bergmann, G.1
Kniggendorf, H.2
Graichen, F.3
Rohlmann, A.4
-
41
-
-
0031016166
-
Hip joint forces during load carrying
-
Bergmann, G., Graichen, F., Rohlmann, A. and Holger, L. Hip joint forces during load carrying. Clin. Orthop. Related Res., 1997, 335, 190-201.
-
(1997)
Clin. Orthop. Related Res.
, vol.335
, pp. 190-201
-
-
Bergmann, G.1
Graichen, F.2
Rohlmann, A.3
Holger, L.4
-
42
-
-
0033213747
-
Hip endoprothesis for in vivo measurement of hip joint force and temperature
-
Graichen, F., Bergmann, G. and Rohlmann, A. Hip endoprothesis for in vivo measurement of hip joint force and temperature. J. Biomechanics, 1999, 33, 1113-1117.
-
(1999)
J. Biomechanics
, vol.33
, pp. 1113-1117
-
-
Graichen, F.1
Bergmann, G.2
Rohlmann, A.3
-
43
-
-
0032857451
-
Mathematical modelling of stress in the hip during gait
-
Ipavec, M., Brand, R. A., Pedersen, D. R., Mavcic, B., Kralj-Iglic, V. and Iglic, A. Mathematical modelling of stress in the hip during gait. J. Biomechanics, 1999, 32, 1229-1235.
-
(1999)
J. Biomechanics
, vol.32
, pp. 1229-1235
-
-
Ipavec, M.1
Brand, R.A.2
Pedersen, D.R.3
Mavcic, B.4
Kralj-Iglic, V.5
Iglic, A.6
-
44
-
-
0024351308
-
Contact pressures from an instrumented hip endoprothesis
-
Hodge, W. A., Carlson, K. L., Fijan, R. S., Burgess, R. G., Riley, P. O., Harris, W. H. and Mann, R. W. Contact pressures from an instrumented hip endoprothesis. J. Bone Jt Surg., 1989, 71A(9), 1378-1386.
-
(1989)
J. Bone Jt Surg.
, vol.71 A
, Issue.9
, pp. 1378-1386
-
-
Hodge, W.A.1
Carlson, K.L.2
Fijan, R.S.3
Burgess, R.G.4
Riley, P.O.5
Harris, W.H.6
Mann, R.W.7
-
45
-
-
0032705073
-
Migration of the acetabular component after revision with impacted morselized allografts
-
A radiostereometric 2-year follow-up analysis of 21 cases
-
Ornstein, E., Franzen, H., Johnsson, R., Sandquist, P., Stefansdottir, A. and Sundberg, M. Migration of the acetabular component after revision with impacted morselized allografts. A radiostereometric 2-year follow-up analysis of 21 cases. Acta Orthop. Scand., 1999, 70(4), 338-342.
-
(1999)
Acta Orthop. Scand.
, vol.70
, Issue.4
, pp. 338-342
-
-
Ornstein, E.1
Franzen, H.2
Johnsson, R.3
Sandquist, P.4
Stefansdottir, A.5
Sundberg, M.6
-
46
-
-
2442652273
-
-
Thesis Lund University, Lund, Sweden
-
Ornstein, E. Hip revisions with impacted morselized allograft bone and cement: patient outcome, prosthetic fixation and risks. Thesis, Lund University, Lund, Sweden, 2002.
-
(2002)
Hip Revisions With Impacted Morselized Allograft Bone and Cement: Patient Outcome, Prosthetic Fixation and Risks
-
-
Ornstein, E.1
-
48
-
-
0033949591
-
Bigger size and defatting of bone chips will increase cup stability
-
Ullmark, G. Bigger size and defatting of bone chips will increase cup stability. Arch. Orthop. Trauma Surg., 2000, 120, 445-447.
-
(2000)
Arch. Orthop. Trauma Surg.
, vol.120
, pp. 445-447
-
-
Ullmark, G.1
|