메뉴 건너뛰기




Volumn 335, Issue , 1997, Pages 190-201

Hip joint forces during load carrying

Author keywords

[No Author keywords available]

Indexed keywords

ACETABULUM; ARTICLE; ENDOPROSTHESIS; FEMUR HEAD; GAIT; HIP; HIP DISEASE; PRIORITY JOURNAL; WEIGHT BEARING;

EID: 0031016166     PISSN: 0009921X     EISSN: 15281132     Source Type: Journal    
DOI: 10.1097/00003086-199702000-00018     Document Type: Article
Times cited : (65)

References (14)
  • 2
    • 0342707320 scopus 로고
    • In vivo Messung der Belastung von Hüftimplantaten
    • Berlin, Freie Universität
    • Bergmann G: In vivo Messung der Belastung von Hüftimplantaten. Habilitationsschrift, Berlin, Freie Universität 1994.
    • (1994) Habilitationsschrift
    • Bergmann, G.1
  • 3
    • 0028472588 scopus 로고
    • Evaluation of ischial weight bearing orthoses, based on in vivo hip joint force measurement
    • Bergmann G, Correa da Silva M, Neff G, Rohlmann A, Graichen F: Evaluation of ischial weight bearing orthoses, based on in vivo hip joint force measurement. Clin Biomech 9:225-234, 1994.
    • (1994) Clin Biomech , vol.9 , pp. 225-234
    • Bergmann, G.1    Correa da Silva, M.2    Neff, G.3    Rohlmann, A.4    Graichen, F.5
  • 4
    • 0027641060 scopus 로고
    • Hip joint forces during walking and running, measured in two patients
    • Bergmann G, Graichen F, Rohlmann A: Hip joint forces during walking and running, measured in two patients. J Biomech 26:969-990, 1993.
    • (1993) J Biomech , vol.26 , pp. 969-990
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3
  • 6
    • 0029294152 scopus 로고
    • Is staircase walking a risk for the fixation of hip implants?
    • Bergmann G, Graichen F, Rohlmann A: Is staircase walking a risk for the fixation of hip implants? J Biomech 28:535-553, 1995.
    • (1995) J Biomech , vol.28 , pp. 535-553
    • Bergmann, G.1    Graichen, F.2    Rohlmann, A.3
  • 8
    • 0029329098 scopus 로고
    • Influence of shoes and heel strike on the loading of hip implants
    • Bergmann G, Kniggendorf H, Graichen F, Rohl- mann A: Influence of shoes and heel strike on the loading of hip implants. J Biomech 28:817-827, 1995.
    • (1995) J Biomech , vol.28 , pp. 817-827
    • Bergmann, G.1    Kniggendorf, H.2    Graichen, F.3    Rohl-mann, A.4
  • 9
    • 0016618910 scopus 로고
    • Studien zur Biomechanik des Hüftgelenks, Teil I
    • Debrunner HU.: Studien zur Biomechanik des Hüftgelenks, Teil I. Z Orthop 113:377-388, 1975.
    • (1975) Z Orthop , vol.113 , pp. 377-388
    • Debrunner, H.U.1
  • 10
    • 0004058126 scopus 로고
    • Space Requirements of the Seated Operator: Geometrical, Kinematic and Mechanical Aspects of the Body with Special Reference to the Limbs
    • Dayton. Wright Patterson Air Force Base
    • Dempster WT: Space Requirements of the Seated Operator: Geometrical, Kinematic and Mechanical Aspects of the Body with Special Reference to the Limbs. Technical Report. Dayton. Wright Patterson Air Force Base 55-159, 1955.
    • (1955) Technical Report , pp. 55-159
    • Dempster, W.T.1
  • 12
    • 0026221442 scopus 로고
    • Four-channel telemetry system for in vivo measurement of hip joint forces
    • Graichen F, Bergmann G: Four-channel telemetry system for in vivo measurement of hip joint forces. J Biomed Eng 1:370-374, 1991.
    • (1991) J Biomed Eng , vol.1 , pp. 370-374
    • Graichen, F.1    Bergmann, G.2
  • 14
    • 0002939744 scopus 로고
    • Der Schenkelhalsbruch, ein mechanisches Problem
    • Pauwels F: Der Schenkelhalsbruch, ein mechanisches Problem. Beilage Z Orthop Chir 63, 1935.
    • (1935) Beilage Z Orthop Chir , vol.63
    • Pauwels, F.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.