메뉴 건너뛰기




Volumn 145, Issue 1, 2008, Pages 135-141

Repeat Microsphere Delivery for Serial Measurement of Regional Blood Perfusion in the Chronically Instrumented, Conscious Canine

Author keywords

chronic arterial catheter; fluorescent polystyrene microspheres; perfusion; subcutaneous vascular access port

Indexed keywords

MICROSPHERE;

EID: 38949184231     PISSN: 00224804     EISSN: 10958673     Source Type: Journal    
DOI: 10.1016/j.jss.2007.04.012     Document Type: Article
Times cited : (21)

References (26)
  • 1
    • 0014114779 scopus 로고
    • The circulation of the fetus in utero. Methods for studying distribution of blood flow, cardiac output and organ blood flow
    • Rudolph A.M., and Heymann M.A. The circulation of the fetus in utero. Methods for studying distribution of blood flow, cardiac output and organ blood flow. Circ Res 21 (1967) 163
    • (1967) Circ Res , vol.21 , pp. 163
    • Rudolph, A.M.1    Heymann, M.A.2
  • 2
    • 0014360360 scopus 로고
    • Measurement of umbilical arterial blood flow to the sheep placenta and fetus in utero. Distribution to cotyledons and the intercotyledonary chorion
    • Makowski E.L., Meschia G., Droegemueller W., et al. Measurement of umbilical arterial blood flow to the sheep placenta and fetus in utero. Distribution to cotyledons and the intercotyledonary chorion. Circ Res 23 (1968) 623
    • (1968) Circ Res , vol.23 , pp. 623
    • Makowski, E.L.1    Meschia, G.2    Droegemueller, W.3
  • 3
    • 0023805223 scopus 로고
    • Evaluation of nonradioactive, colored microspheres for measurement of regional myocardial blood flow in dogs
    • Hale S.L., Alker K.J., and Kloner R.A. Evaluation of nonradioactive, colored microspheres for measurement of regional myocardial blood flow in dogs. Circulation 78 (1988) 428
    • (1988) Circulation , vol.78 , pp. 428
    • Hale, S.L.1    Alker, K.J.2    Kloner, R.A.3
  • 4
    • 38949141063 scopus 로고    scopus 로고
    • Glenny RW, Bernard S, Brinkley M. Validation of fluorescent-labeled microspheres for measurement of regional organ perfusion.
    • Glenny RW, Bernard S, Brinkley M. Validation of fluorescent-labeled microspheres for measurement of regional organ perfusion.
  • 5
    • 85047678005 scopus 로고
    • Developments in non-radioactive microsphere techniques for blood flow measurement
    • Prinzen F.W., and Glenny R.W. Developments in non-radioactive microsphere techniques for blood flow measurement. Cardiovasc Res 28 (1994) 1467
    • (1994) Cardiovasc Res , vol.28 , pp. 1467
    • Prinzen, F.W.1    Glenny, R.W.2
  • 6
    • 33750870304 scopus 로고    scopus 로고
    • Fluorescent microspheres are superior to radioactive microspheres in chronic blood flow measurements
    • Van Oosterhout M.F., Prinzen F.W., Sakurada S., et al. Fluorescent microspheres are superior to radioactive microspheres in chronic blood flow measurements. Am J Physiol 275 (1998) H110
    • (1998) Am J Physiol , vol.275
    • Van Oosterhout, M.F.1    Prinzen, F.W.2    Sakurada, S.3
  • 7
    • 0036354739 scopus 로고    scopus 로고
    • Chronic left heart catheterization for microvascular blood flow determination in the rabbit: A minimally invasive technique using specially designed port devices
    • Hoffmann J.N., Steinhagen S., Kast C., et al. Chronic left heart catheterization for microvascular blood flow determination in the rabbit: A minimally invasive technique using specially designed port devices. J Surg Res 102 (2002) 119
    • (2002) J Surg Res , vol.102 , pp. 119
    • Hoffmann, J.N.1    Steinhagen, S.2    Kast, C.3
  • 8
    • 0035001034 scopus 로고    scopus 로고
    • Myocardial stunning in exercise-induced ischemia in dogs: Lack of late preconditioning
    • De Curzon O.P., Ghaleh B., Tissier R., et al. Myocardial stunning in exercise-induced ischemia in dogs: Lack of late preconditioning. Am J Physiol Heart Circ Physiol 280 (2001) H302
    • (2001) Am J Physiol Heart Circ Physiol , vol.280
    • De Curzon, O.P.1    Ghaleh, B.2    Tissier, R.3
  • 9
    • 0032029153 scopus 로고    scopus 로고
    • Flow-function relations during graded coronary occlusions in the dog: Effects of transmural location and segment orientation
    • McCulloch A.D., Sung D., Wilson J.M., et al. Flow-function relations during graded coronary occlusions in the dog: Effects of transmural location and segment orientation. Cardiovasc Res 37 (1998) 636
    • (1998) Cardiovasc Res , vol.37 , pp. 636
    • McCulloch, A.D.1    Sung, D.2    Wilson, J.M.3
  • 10
    • 15844415940 scopus 로고    scopus 로고
    • Vascular endothelial growth factor administration in chronic myocardial ischemia
    • Harada K., Friedman M., Lopez J.J., et al. Vascular endothelial growth factor administration in chronic myocardial ischemia. Am J Physiol 270 (1996) H1791
    • (1996) Am J Physiol , vol.270
    • Harada, K.1    Friedman, M.2    Lopez, J.J.3
  • 11
    • 0029978701 scopus 로고    scopus 로고
    • Ischemic event characteristics determine the extent of myocardial stunning in conscious dogs
    • Wouters P.F., Van de Velde M., Van Aken H., et al. Ischemic event characteristics determine the extent of myocardial stunning in conscious dogs. Basic Res Cardiol 91 (1996) 140
    • (1996) Basic Res Cardiol , vol.91 , pp. 140
    • Wouters, P.F.1    Van de Velde, M.2    Van Aken, H.3
  • 12
    • 0030691144 scopus 로고    scopus 로고
    • Myocardial, skeletal muscle, and renal blood flow during exercise in conscious dogs with heart failure
    • Neumann T., and Heusch G. Myocardial, skeletal muscle, and renal blood flow during exercise in conscious dogs with heart failure. Am J Physiol 273 (1997) H2452
    • (1997) Am J Physiol , vol.273
    • Neumann, T.1    Heusch, G.2
  • 13
    • 0026681510 scopus 로고
    • Three-dimensional analysis of regional mechanical function, blood flow and electrophysiological parameters during early myocardial ischemia in dogs
    • Kowallik P., Baumgart D., Skyschally A., et al. Three-dimensional analysis of regional mechanical function, blood flow and electrophysiological parameters during early myocardial ischemia in dogs. Basic Res Cardiol 87 (1992) 215
    • (1992) Basic Res Cardiol , vol.87 , pp. 215
    • Kowallik, P.1    Baumgart, D.2    Skyschally, A.3
  • 14
    • 0021402031 scopus 로고
    • Increased number of myocardial blood flow measurements with radionuclide-labeled microspheres
    • Baer R.W., Payne B.D., Verrier E.D., et al. Increased number of myocardial blood flow measurements with radionuclide-labeled microspheres. Am J Physiol 246 (1984) H418
    • (1984) Am J Physiol , vol.246
    • Baer, R.W.1    Payne, B.D.2    Verrier, E.D.3
  • 15
    • 0022115279 scopus 로고
    • New implanted chronic catheter device for determining blood pressure and cardiac output in conscious dog
    • Garner D., and Laks M.M. New implanted chronic catheter device for determining blood pressure and cardiac output in conscious dog. Am J Physiol 249 (1985) H681
    • (1985) Am J Physiol , vol.249
    • Garner, D.1    Laks, M.M.2
  • 16
    • 0016194245 scopus 로고
    • Cardiopulmonary function of awake, sedated, and anesthetized beagle dogs
    • Muggenburg B.A., and Mauderly J.L. Cardiopulmonary function of awake, sedated, and anesthetized beagle dogs. J Appl Physiol 37 (1974) 152
    • (1974) J Appl Physiol , vol.37 , pp. 152
    • Muggenburg, B.A.1    Mauderly, J.L.2
  • 17
    • 33751094809 scopus 로고    scopus 로고
    • Technique for implantation of chronic indwelling aortic access catheters
    • Bartoli C.R., Okabe K., Akiyama I., et al. Technique for implantation of chronic indwelling aortic access catheters. J Invest Surg 19 (2006) 397
    • (2006) J Invest Surg , vol.19 , pp. 397
    • Bartoli, C.R.1    Okabe, K.2    Akiyama, I.3
  • 18
    • 0348159253 scopus 로고
    • A technique for continuous measurement of arterial blood pressure in unanesthatized monkeys
    • Werdegar D., Johnson D.G., and Mason J.W. A technique for continuous measurement of arterial blood pressure in unanesthatized monkeys. J Appl Physiol 19 (1964) 519
    • (1964) J Appl Physiol , vol.19 , pp. 519
    • Werdegar, D.1    Johnson, D.G.2    Mason, J.W.3
  • 19
    • 0001436864 scopus 로고
    • Simplified technique for chronic catheterization of blood vessels
    • Herd J.A., and Barger A.C. Simplified technique for chronic catheterization of blood vessels. J Appl Physiol 19 (1964) 791
    • (1964) J Appl Physiol , vol.19 , pp. 791
    • Herd, J.A.1    Barger, A.C.2
  • 20
    • 38949150261 scopus 로고    scopus 로고
    • Bartoli CR, Akiyama I, Godleski JJ, et al. Long-term pericardial catheterization is associated with minimum foreign body response. Catheter Cardiovasc Interv (In Press).
    • Bartoli CR, Akiyama I, Godleski JJ, et al. Long-term pericardial catheterization is associated with minimum foreign body response. Catheter Cardiovasc Interv (In Press).
  • 21
    • 0023236930 scopus 로고
    • Validity of microsphere depositions for regional myocardial flows
    • Bassingthwaighte J.B., Malone M.A., Moffett T.C., et al. Validity of microsphere depositions for regional myocardial flows. Am J Physiol 253 (1987) H184
    • (1987) Am J Physiol , vol.253
    • Bassingthwaighte, J.B.1    Malone, M.A.2    Moffett, T.C.3
  • 22
    • 0025959655 scopus 로고    scopus 로고
    • Kowallik P, Schulz R, Guth BD, et al. Measurement of regional myocardial blood flow with multiple colored microspheres. Circulation 19914;83:974.
    • Kowallik P, Schulz R, Guth BD, et al. Measurement of regional myocardial blood flow with multiple colored microspheres. Circulation 19914;83:974.
  • 23
    • 0033886823 scopus 로고    scopus 로고
    • Hemodynamic effects of 15-microm-diameter microspheres on the rat pulmonary circulation
    • Glenny R.W., Bernard S.L., and Lamm W.J. Hemodynamic effects of 15-microm-diameter microspheres on the rat pulmonary circulation. J Appl Physiol 89 (2000) 499
    • (2000) J Appl Physiol , vol.89 , pp. 499
    • Glenny, R.W.1    Bernard, S.L.2    Lamm, W.J.3
  • 24
    • 2342486106 scopus 로고    scopus 로고
    • Fluorescent microsphere method is suitable for chronic bone blood flow measurement: A long-term study after meniscectomy in rabbits
    • Anetzberger H., Thein E., Loffler G., et al. Fluorescent microsphere method is suitable for chronic bone blood flow measurement: A long-term study after meniscectomy in rabbits. J Appl Physiol 96 (2004) 1928
    • (2004) J Appl Physiol , vol.96 , pp. 1928
    • Anetzberger, H.1    Thein, E.2    Loffler, G.3
  • 25
    • 0034984758 scopus 로고    scopus 로고
    • Extending fluorescent microsphere methods for regional organ blood flow to 13 simultaneous colors
    • Schimmel C., Frazer D., and Glenny R.W. Extending fluorescent microsphere methods for regional organ blood flow to 13 simultaneous colors. Am J Physiol Heart Circ Physiol 280 (2001) H2496
    • (2001) Am J Physiol Heart Circ Physiol , vol.280
    • Schimmel, C.1    Frazer, D.2    Glenny, R.W.3
  • 26
    • 0029098915 scopus 로고
    • Polystyrene microspheres decrease bronchial artery resistance in anesthetized sheep
    • Pearse D.B., Fessler H.E., and Wagner E.M. Polystyrene microspheres decrease bronchial artery resistance in anesthetized sheep. Am J Physiol 269 (1995) H1037
    • (1995) Am J Physiol , vol.269
    • Pearse, D.B.1    Fessler, H.E.2    Wagner, E.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.