메뉴 건너뛰기




Volumn 275, Issue 1 44-1, 1998, Pages

Fluorescent microspheres are superior to radioactive microspheres in chronic blood flow measurements

Author keywords

Cardiac output distribution; Chronic animal experiments; Fluorescence; Nonradioactive microspheres; Organ flow

Indexed keywords

MICROSPHERE;

EID: 33750870304     PISSN: 03636135     EISSN: None     Source Type: Journal    
DOI: 10.1152/ajpheart.1998.275.1.h110     Document Type: Article
Times cited : (50)

References (14)
  • 1
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland, J. M., and D. G. Altman. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1: 307-310, 1986.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 2
    • 0029115032 scopus 로고
    • Fluorescent vs. radioactive microsphere measurement of regional myocardial blood flow
    • Chien, G. L., C. G. Anselone, R. F. Davis, and D. M. Van Winkle. Fluorescent vs. radioactive microsphere measurement of regional myocardial blood flow. Cardiovasc. Res. 30: 405-412, 1995.
    • (1995) Cardiovasc. Res. , vol.30 , pp. 405-412
    • Chien, G.L.1    Anselone, C.G.2    Davis, R.F.3    Van Winkle, D.M.4
  • 4
    • 0027231021 scopus 로고
    • Validation of fluorescent-labeled microspheres for measurement of regional organ perfusion
    • Glenny, R. W., S. Bernard, and M. Brinkley. Validation of fluorescent-labeled microspheres for measurement of regional organ perfusion. J. Appl. Physiol. 74: 2585-2597, 1993.
    • (1993) J. Appl. Physiol. , vol.74 , pp. 2585-2597
    • Glenny, R.W.1    Bernard, S.2    Brinkley, M.3
  • 5
    • 2642702275 scopus 로고
    • Practical considerations in the use of microspheres for evaluation of cardiovascular and thermoregulatory interactions
    • Hales, J. R. S. Practical considerations in the use of microspheres for evaluation of cardiovascular and thermoregulatory interactions. Biomed. Thermol. 13: 127-145, 1994.
    • (1994) Biomed. Thermol. , vol.13 , pp. 127-145
    • Hales, J.R.S.1
  • 6
    • 0015794542 scopus 로고
    • Radioactive microsphere measurement of cardiac output and regional tissue blood flow in the sheep
    • Hales, J. R. S. Radioactive microsphere measurement of cardiac output and regional tissue blood flow in the sheep. Pflügers Arch. 344: 119-132, 1973.
    • (1973) Pflügers Arch. , vol.344 , pp. 119-132
    • Hales, J.R.S.1
  • 7
    • 0017190445 scopus 로고
    • Effects of acute cold exposure on the distribution of cardiac output in the sheep
    • Hales, J. R. S., J. W. Bennett, and A. A. Fawcett. Effects of acute cold exposure on the distribution of cardiac output in the sheep. Pflügers Arch. 366: 153-157, 1976.
    • (1976) Pflügers Arch. , vol.366 , pp. 153-157
    • Hales, J.R.S.1    Bennett, J.W.2    Fawcett, A.A.3
  • 8
    • 0017702448 scopus 로고
    • Direct observations of the behaviour of microspheres in microvasculature
    • Hales, J. R. S., and W. J. Cliff. Direct observations of the behaviour of microspheres in microvasculature. Bibl. Anat. 15: 87-91, 1977.
    • (1977) Bibl. Anat. , vol.15 , pp. 87-91
    • Hales, J.R.S.1    Cliff, W.J.2
  • 9
    • 0018770325 scopus 로고
    • Observations on the validity of using NEN-Trac microspheres for measuring organ blood flow
    • Hales, J. R. S., R. B. King, and A. A. Fawcett. Observations on the validity of using NEN-Trac microspheres for measuring organ blood flow. Pflügers Arch. 379: 295-296, 1979.
    • (1979) Pflügers Arch. , vol.379 , pp. 295-296
    • Hales, J.R.S.1    King, R.B.2    Fawcett, A.A.3
  • 13
    • 85047678005 scopus 로고
    • Developments in non-radioactive microsphere techniques for blood flow measurement
    • Prinzen, F. W., and R. W. Glenny. Developments in non-radioactive microsphere techniques for blood flow measurement. Cardiovasc. Res. 28: 1467-1475, 1994.
    • (1994) Cardiovasc. Res. , vol.28 , pp. 1467-1475
    • Prinzen, F.W.1    Glenny, R.W.2
  • 14
    • 0029097678 scopus 로고
    • Validation of fluorescent microsphere technique for measurement of organ perfusion with improved sample processing method
    • Heart Circ. Physiol. 38
    • Van Oosterhout, M. F. M., H. M. M. Willigers, R. S. Reneman, and F. W. Prinzen. Validation of fluorescent microsphere technique for measurement of organ perfusion with improved sample processing method. Am. J. Physiol. 269 (Heart Circ. Physiol. 38): H725-H733, 1995.
    • (1995) Am. J. Physiol. , vol.269
    • Van Oosterhout, M.F.M.1    Willigers, H.M.M.2    Reneman, R.S.3    Prinzen, F.W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.