-
1
-
-
0026254046
-
Optical coherence tomography
-
D. Huang, E. A. Swanson, C. P. Lin, J. S. Schuman, W. G. Stinson, W. Chang, M. R. Hee, T. Flotte, K. Gregory, C. A. Puliafito, and J. G. Fujimoto, "Optical coherence tomography," Science 254(5035) 1178-1181 (1991). (Pubitemid 21917444)
-
(1991)
Science
, vol.254
, Issue.5035
, pp. 1178-1181
-
-
Huang, D.1
Swanson, E.A.2
Lin, C.P.3
Schuman, J.S.4
Stinson, W.G.5
Chang, W.6
Hee, M.R.7
Flotte, T.8
Gregory, K.9
Puliafito, C.A.10
Fujimoto, J.G.11
-
4
-
-
84975568379
-
New measurement system for fault location in optical waveguide devices based on an interferometric technique
-
K. Takada, I. Yokohama, K. Chida, and J. Noda, "New measurement system for fault location in optical waveguide devices based on an interferometric technique," Appl. Opt. 26(9), 1603-1606 (1987).
-
(1987)
Appl. Opt.
, vol.26
, Issue.9
, pp. 1603-1606
-
-
Takada, K.1
Yokohama, I.2
Chida, K.3
Noda, J.4
-
5
-
-
0023136979
-
Optical coherence-domain reflectometry: A new optical evaluation technique
-
R. C. Youngquist, S. Carr, and D. E. N. Davies, "Optical coherencedomain reflectometry: a new optical evaluation technique," Opt. Lett. 12(3), 158-160 (1987). (Pubitemid 17035962)
-
(1987)
Optics Letters
, vol.12
, Issue.3
, pp. 158-160
-
-
Youngquist, R.C.1
Carr, S.2
Davies, D.E.N.3
-
6
-
-
84975538971
-
Eye-length measurement by interferometry with partially coherent light
-
A. F. Fercher, K. Mengedoht, and W. Werner, "Eye-length measurement by interferometry with partially coherent light," Opt. Lett. 13(3), 186-188 (1988).
-
(1988)
Opt. Lett.
, vol.13
, Issue.3
, pp. 186-188
-
-
Fercher, A.F.1
Mengedoht, K.2
Werner, W.3
-
8
-
-
84894153847
-
Hot technologies for 2007: OCT: Imaging of the future
-
M. Walz, "Hot technologies for 2007: OCT: imaging of the future," R&D Mag., 6(12) (2006).
-
(2006)
R&D Mag.
, vol.6
, Issue.12
-
-
Walz, M.1
-
9
-
-
33646875756
-
Retinal assessment using optical coherence tomography
-
DOI 10.1016/j.preteyeres.2006.03.001, PII S1350946206000048
-
R. A. Costa, M. Skaf, L. A. S. Melo, D. Calucci, J. A. Cardillo, J. C. Castro, D. Huang, and M. Wojtkowski, "Retinal assessment using optical coherence tomography," Prog. Retin Eye Res. 25(3), 325-353 (2006). (Pubitemid 43782816)
-
(2006)
Progress in Retinal and Eye Research
, vol.25
, Issue.3
, pp. 325-353
-
-
Costa, R.A.1
Skaf, M.2
Melo Jr., L.A.S.3
Calucci, D.4
Cardillo, J.A.5
Castro, J.C.6
Huang, D.7
Wojtkowski, M.8
-
11
-
-
0028875360
-
Quantitative assessment of macular edema with optical coherence tomography
-
M. R. Hee, C. A. Puliafito, C. Wong, J. S. Duker, E. Reichel, B. Rutledge, J. S. Schuman, E. A. Swanson, and J. G. Fujimoto, "Quantitative assessment of macular edema with optical coherence tomography," Arch. Ophthalmol. (Chicago) 113(8), 1019-1029 (1995).
-
(1995)
Arch. Ophthalmol. (Chicago)
, vol.113
, Issue.8
, pp. 1019-1029
-
-
Hee, M.R.1
Puliafito, C.A.2
Wong, C.3
Duker, J.S.4
Reichel, E.5
Rutledge, B.6
Schuman, J.S.7
Swanson, E.A.8
Fujimoto, J.G.9
-
12
-
-
17044368859
-
-
Slack, Inc., Thorofare, NJ
-
J. S. Schuman, C. A. Puliafito, and J. G. Fujimoto, Optical Coherence Tomography of Ocular Diseases, Slack, Inc., Thorofare, NJ (2004).
-
(2004)
Optical Coherence Tomography of Ocular Diseases
-
-
Schuman, J.S.1
Puliafito, C.A.2
Fujimoto, J.G.3
-
13
-
-
84887846153
-
Optical coherence tomography: Rewriting the standard of care in diagnosis, management and interventional assessment
-
L. Alexander and W. Choate, "Optical coherence tomography: rewriting the standard of care in diagnosis, management and interventional assessment," Rev. Optometry 141(9), 1CE-8CE (2004).
-
(2004)
Rev. Optometry
, vol.141
, Issue.9
-
-
Alexander, L.1
Choate, W.2
-
14
-
-
0034798385
-
Initial stages of posterior vitreous detachment in healthy eyes of older persons evaluated by optical coherence tomography
-
E. Uchino, A. Uemura, and N. Ohba, "Initial stages of posterior vitreous detachment in healthy eyes of older persons evaluated by optical coherence tomography," Arch. Ophthalmol. (Chicago) 119(10), 1475-1479 (2001). (Pubitemid 32963251)
-
(2001)
Archives of Ophthalmology
, vol.119
, Issue.10
, pp. 1475-1479
-
-
Uchino, E.1
Uemura, A.2
Ohba, N.3
-
15
-
-
0042737969
-
Macular hole: Improved understanding of pathogenesis, staging, and management based on optical coherence tomography
-
DOI 10.1076/soph.18.2.58.15858
-
M. Altaweel and M. Ip, "Macular hole: improved understanding of pathogenesis, staging, and management based on optical coherence tomography," Semin Ophthalmol. 18(2), 58-66 (2003). (Pubitemid 37108394)
-
(2003)
Seminars in Ophthalmology
, vol.18
, Issue.2
, pp. 58-66
-
-
Altaweel, M.1
Ip, M.2
-
16
-
-
0033031451
-
Macular hole formation: New data provided by optical coherence tomography
-
A. Gaudric, B. Haouchine, P. Massin, M. Paques, P. Blain, and A. Erginay, "Macular hole formation: new data provided by optical coherence tomography," Arch. Ophthalmol. (Chicago) 117(6), 744-751 (1999). (Pubitemid 29265033)
-
(1999)
Archives of Ophthalmology
, vol.117
, Issue.6
, pp. 744-751
-
-
Gaudric, A.1
Haouchine, B.2
Massin, P.3
Paques, M.4
Blain, P.5
Erginay, A.6
-
17
-
-
0029022423
-
Optical coherence tomography of macular holes
-
M. R. Hee, C. A. Puliafito, C. Wong, J. S. Duker, E. Reichel, J. S. Schuman, E. A. Swanson, and J. G. Fujimoto, "Optical coherence tomography of macular holes," Ophthalmology 102(5), 748-756 (1995).
-
(1995)
Ophthalmology
, vol.102
, Issue.5
, pp. 748-756
-
-
Hee, M.R.1
Puliafito, C.A.2
Wong, C.3
Duker, J.S.4
Reichel, E.5
Schuman, J.S.6
Swanson, E.A.7
Fujimoto, J.G.8
-
18
-
-
0028883206
-
Imaging of macular diseases with optical coherence tomography
-
C. A. Puliafito, M. R. Hee, C. P. Lin, E. Reichel, J. S. Schuman, J. S. Duker, J. A. Izatt, E. A. Swanson, and J. G. Fujimoto, "Imaging of macular diseases with optical coherence tomography," Ophthalmology 102(2), 217-229 (1995).
-
(1995)
Ophthalmology
, vol.102
, Issue.2
, pp. 217-229
-
-
Puliafito, C.A.1
Hee, M.R.2
Lin, C.P.3
Reichel, E.4
Schuman, J.S.5
Duker, J.S.6
Izatt, J.A.7
Swanson, E.A.8
Fujimoto, J.G.9
-
19
-
-
0036846622
-
Evaluation of successful macular hole surgery by optical coherence tomography and multifocal electroretinography
-
DOI 10.1016/S0002-9394(02)01700-2, PII S0002939402017002
-
M. N. Apostolopoulos, C. N. Koutsandrea, M. N. Moschos, D. A. Alonistiotis, A. E. Papaspyrou, J. A. Mallias, T. E. Kyriaki, P. G. Theodossiadis, and G. P. Theodossiadis, "Evaluation of successful macular hole surgery by optical coherence tomography and multifocal electroretinography, " Am. J. Ophthalmol. 134(5), 667-674 (2002). (Pubitemid 35300384)
-
(2002)
American Journal of Ophthalmology
, vol.134
, Issue.5
, pp. 667-674
-
-
Apostolopoulos, M.N.1
Koutsandrea, C.N.2
Moschos, M.N.3
Alonistiotis, D.A.4
Papaspyrou, A.E.5
Mallias, J.A.6
Kyriaki, T.E.7
Theodossiadis, P.G.8
Theodossiadis, G.P.9
-
20
-
-
0033945688
-
Features of macular hole closure in the early postoperative period using optical coherence tomography
-
J. M. Jumper, R. P. Gallemore, B. W. McCuen, and C. A. Toth, "Features of macular hole closure in the early postoperative period using optical coherence tomography," Retina 20(3), 232-237 (2000). (Pubitemid 30436773)
-
(2000)
Retina
, vol.20
, Issue.3
, pp. 232-237
-
-
Jumper, J.M.1
Gallemore, R.P.2
McCuen II, B.W.3
Toth, C.A.4
-
21
-
-
0038353778
-
Observation of idiopathic full-thickness macular hole closure in early postoperative period as evaluated by optical coherence tomography
-
DOI 10.1016/S0002-9394(03)00094-1
-
H. Sato, R. Kawasaki, and H. Yamashita, "Observation of idiopathic full-thickness macular hole closure in early postoperative period as evaluated by optical coherence tomography," Am. J. Ophthalmol. 136(1), 185-187 (2003). (Pubitemid 36794516)
-
(2003)
American Journal of Ophthalmology
, vol.136
, Issue.1
, pp. 185-187
-
-
Sato, H.1
Kawasaki, R.2
Yamashita, H.3
-
22
-
-
0034108888
-
Comparison between optical coherence tomography and fundus fluorescein angiography for the detection of cystoid macular edema in patients with uveitis
-
DOI 10.1016/S0161-6420(99)00087-1, PII S0161642099000871
-
R. J. Antcliff, M. R. Stanford, D. S. Chauhan, E. M. Graham, D. J. Spalton, J. S. Shilling, T. J. ffytche, and J. Marshall, "Comparison between optical coherence tomography and fundus fluorescein angiography for the detection of cystoid macular edema in patients with uveitis," Ophthalmology 107(3), 593-599 (2000). (Pubitemid 30191384)
-
(2000)
Ophthalmology
, vol.107
, Issue.3
, pp. 593-599
-
-
Antcliff, R.J.1
Stanford, M.R.2
Chauhan, D.S.3
Graham, E.M.4
Spalton, D.J.5
Shilling, J.S.6
Ffytche, T.J.7
Marshall, J.8
-
23
-
-
0031952382
-
Topography of diabetic macular edema with optical coherence tomography
-
DOI 10.1016/S0161-6420(98)93601-6
-
M. R. Hee, C. A. Puliafito, J. S. Duker, E. Reichel, J. G. Coker, J. R. Wilkins, J. S. Schuman, E. A. Swanson, and J. G. Fujimoto, "Topography of diabetic macular edema with optical coherence tomography," Ophthalmology 105(2), 360-370 (1998). (Pubitemid 28090845)
-
(1998)
Ophthalmology
, vol.105
, Issue.2
, pp. 360-370
-
-
Hee, M.R.1
Puliafito, C.A.2
Duker, J.S.3
Reichel, E.4
Coker, J.G.5
Wilkins, J.R.6
Schuman, J.S.7
Swanson, E.A.8
Fujimoto, J.G.9
-
24
-
-
0034535776
-
Optical coherence tomography of idiopathic macular epiretinal membranes before and after surgery
-
DOI 10.1016/S0002-9394(00)00574-2, PII S0002939400005742
-
P. Massin, C. Allouch, B. Haouchine, F. Metge, M. Paques, L. Tangui, A. Erginay, and A. Gaudric, "Optical coherence tomography of idiopathic macular epiretinal membranes before and after surgery," Am. J. Ophthalmol. 130(6), 732-739 (2000). (Pubitemid 32004653)
-
(2000)
American Journal of Ophthalmology
, vol.130
, Issue.6
, pp. 732-739
-
-
Massin, P.1
Allouch, C.2
Haouchine, B.3
Metge, F.4
Paques, M.5
Tangui, L.6
Erginay, A.7
Gaudric, A.8
-
25
-
-
0032997035
-
Patterns of diabetic macular edema with optical coherence tomography
-
DOI 10.1016/S0002-9394(99)00033-1, PII S0002939499000331
-
T. Otani, S. Kishi, and Y. Maruyama, "Patterns of diabetic macular edema with optical coherence tomography," Am. J. Ophthalmol. 127(6), 688-693 (1999). (Pubitemid 29266745)
-
(1999)
American Journal of Ophthalmology
, vol.127
, Issue.6
, pp. 688-693
-
-
Otani, T.1
Kishi, S.2
Maruyama, Y.3
-
26
-
-
0029787327
-
Optical coherence tomography of age-related macular degeneration and choroidal neovascularization
-
M. R. Hee, C. R. Baumal, C. A. Puliafito, J. S. Duker, E. Reichel, J. R. Wilkins, J. G. Coker, J. S. Schuman, E. A. Swanson, and J. G. Fujimoto, "Optical coherence tomography of age-related macular degeneration and choroidal neovascularization," Ophthalmology 103(8), 1260-1270 (1996). (Pubitemid 26282510)
-
(1996)
Ophthalmology
, vol.103
, Issue.8
, pp. 1260-1270
-
-
Hee, M.R.1
Baumal, C.R.2
Puliafito, C.A.3
Duker, J.S.4
Reichel, E.5
Wilkins, J.R.6
Coker, J.G.7
Schuman, J.S.8
Swanson, E.A.9
Fujimoto, J.G.10
-
27
-
-
11844270529
-
Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography
-
DOI 10.1016/j.ajo.2004.08.069, PII S0002939404010815
-
F. A. Medeiros, L. M. Zangwill, C. Bowd, R. M. Vessani, R. Susanna, and R. N. Weinreb, "Evaluation of retinal nerve fiber layer, optic nerve head, and macular thickness measurements for glaucoma detection using optical coherence tomography," Am. J. Ophthalmol. 139(1), 44-55 (2005). (Pubitemid 40094839)
-
(2005)
American Journal of Ophthalmology
, vol.139
, Issue.1
, pp. 44-55
-
-
Medeiros, F.A.1
Zangwill, L.M.2
Bowd, C.3
Vessani, R.M.4
Susanna Jr., R.5
Weinreb, R.N.6
-
28
-
-
27744580130
-
Retinal nerve fiber layer thickness map determined from optical coherence tomography images
-
DOI 10.1364/OPEX.13.009480
-
M. Mujat, R. C. Chan, B. Cense, B. H. Park, C. Joo, T. Akkin, T. C. Chen, and J. F. de Boer, "Retinal nerve fiber layer thickness map determined from optical coherence tomography images," Opt. Express 13(23), 9480-9491 (2005). (Pubitemid 41611983)
-
(2005)
Optics Express
, vol.13
, Issue.23
, pp. 9480-9491
-
-
Mujat, M.1
Chan, R.C.2
Cense, B.3
Park, B.H.4
Joo, C.5
Akkin, T.6
Chen, T.C.7
De Boer, J.F.8
-
29
-
-
0033653784
-
Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography
-
E. Z. Blumenthal, J. M. Williams, R. N. Weinreb, C. A. Girkin, C. C. Berry, and L. M. Zangwill, "Reproducibility of nerve fiber layer thickness measurements by use of optical coherence tomography," Ophthalmology 107(12), 2278-2282 (2000).
-
(2000)
Ophthalmology
, vol.107
, Issue.12
, pp. 2278-2282
-
-
Blumenthal, E.Z.1
Williams, J.M.2
Weinreb, R.N.3
Girkin, C.A.4
Berry, C.C.5
Zangwill, L.M.6
-
30
-
-
23244456347
-
Reproducibility of retinal nerve fiber thickness measurements using the stratus OCT in normal and glaucomatous eyes
-
DOI 10.1167/iovs.04-1174
-
D. L. Budenz, R. T. Chang, X. Huang, R. W. Knighton, and J. M. Tielsch, "Reproducibility of retinal nerve fiber thickness measurements using the Stratus OCT in normal and glaucomatous eyes," Invest. Ophthalmol. Visual Sci. 46(7), 2440-2443 (2005). (Pubitemid 43119491)
-
(2005)
Investigative Ophthalmology and Visual Science
, vol.46
, Issue.7
, pp. 2440-2443
-
-
Budenz, D.L.1
Chang, R.T.2
Huang, X.3
Knighton, R.W.4
Tielsch, J.M.5
-
31
-
-
0037228533
-
Reliability of nerve fiber layer thickness measurements using optical coherence tomography in normal and glaucomatous eyes
-
DOI 10.1016/S0161-6420(02)01296-4, PII S0161642002012964
-
P. Carpineto, M. Ciancaglini, E. Zuppardi, G. Falconio, E. Doronzo, and L. Mastropasqua, "Reliability of nerve fiber layer thickness measurements using optical coherence tomography in normal and glaucomatous eyes," Ophthalmology 110(1), 190-195 (2003). (Pubitemid 36068744)
-
(2003)
Ophthalmology
, vol.110
, Issue.1
, pp. 190-195
-
-
Carpineto, P.1
Ciancaglini, M.2
Zuppardi, E.3
Falconio, G.4
Doronzo, E.5
Mastropasqua, L.6
-
32
-
-
3042668265
-
Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT
-
DOI 10.1167/iovs.03-0514
-
L. A. Paunescu, J. S. Schuman, L. L. Price, P. C. Stark, S. Beaton, H. Ishikawa, G. Wollstein, and J. G. Fujimoto, "Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using StratusOCT," Invest. Ophthalmol. Visual Sci. 45(6), 1716-1724 (2004). (Pubitemid 38868963)
-
(2004)
Investigative Ophthalmology and Visual Science
, vol.45
, Issue.6
, pp. 1716-1724
-
-
Paunescu, L.A.1
Schuman, J.S.2
Price, L.L.3
Stark, P.C.4
Beaton, S.5
Ishikawa, H.6
Wollstein, G.7
Fujimoto, J.G.8
-
33
-
-
20144389022
-
Optical coherence tomography longitudinal evaluation of retinal nerve fiber layer thickness in glaucoma
-
DOI 10.1001/archopht.123.4.464
-
G. Wollstein, J. S. Schuman, L. L. Price, A. Aydin, P. C. Stark, E. Hertzmark, E. Lai, H. Ishikawa, C. Mattox, J. G. Fujimoto, and L. A. Paunescu, "Optical coherence tomography longitudinal evaluation of retinal nerve fiber layer thickness in glaucoma," Arch. Ophthalmol. (Chicago) 123(4), 464-470 (2005). (Pubitemid 40489916)
-
(2005)
Archives of Ophthalmology
, vol.123
, Issue.4
, pp. 464-470
-
-
Wollstein, G.1
Schuman, J.S.2
Price, L.L.3
Aydin, A.4
Stark, P.C.5
Hertzmark, E.6
Lai, E.7
Ishikawa, H.8
Mattox, C.9
Fujimoto, J.G.10
Paunescu, L.A.11
-
34
-
-
9144271384
-
Evaluation of scanning resolution on retinal nerve fiber layer measurement using optical coherence tomography in normal and glaucomatous eyes
-
DOI 10.1097/01.ijg.0000138205.99424.24
-
C. K. S. Leung, W. H. Yung, A. C. K. Ng, J. Woo, M. K. Tsang, and K. K. Tse, "Evaluation of scanning resolution on retinal nerve fiber layer measurement using optical coherence tomography in normal and glaucomatous eyes," J. Glaucoma 13(6), 479-485 (2004). (Pubitemid 39546342)
-
(2004)
Journal of Glaucoma
, vol.13
, Issue.6
, pp. 479-485
-
-
Leung, C.K.-S.1
Yung, W.H.2
Ng, A.C.K.3
Woo, J.4
Tsang, M.K.5
Tse, K.K.6
-
35
-
-
0029068398
-
Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography: A pilot study
-
J. S. Schuman, M. R. Hee, C. A. Puliafito, C. Wong, T. Pedut- Kloizman, C. P. Lin, E. Hertzmark, J. A. Izatt, E. A. Swanson, and J. G. Fujimoto, "Quantification of nerve fiber layer thickness in normal and glaucomatous eyes using optical coherence tomography: A pilot study," Arch. Ophthalmol. (Chicago) 113(5), 586-596 (1995).
-
(1995)
Arch. Ophthalmol. (Chicago)
, vol.113
, Issue.5
, pp. 586-596
-
-
Schuman, J.S.1
Hee, M.R.2
Puliafito, C.A.3
Wong, C.4
Pedut- Kloizman, T.5
Lin, C.P.6
Hertzmark, E.7
Izatt, J.A.8
Swanson, E.A.9
Fujimoto, J.G.10
-
36
-
-
4744340441
-
Short-wavelength automated perimetry results are correlated with optical coherence tomography retinal nerve fiber layer thickness measurements in glaucomatous eyes
-
DOI 10.1016/j.ophtha.2004.04.017, PII S0161642004008115
-
C. A. Sánchez-Galeana, C. Bowd, L. M. Zangwill, P. A. Sample, and R. N. Weinreb, "Short-wavelength automated perimetry results are correlated with optical coherence tomography retinal nerve fiber layer thickness measurements in glaucomatous eyes," Ophthalmology 111(10), 1866-1872 (2004). (Pubitemid 39311838)
-
(2004)
Ophthalmology
, vol.111
, Issue.10
, pp. 1866-1872
-
-
Sanchez-Galeana, C.A.1
Bowd, C.2
Zangwill, L.M.3
Sample, P.A.4
Weinreb, R.N.5
-
37
-
-
3242669893
-
Optical coherence tomography - A review of the principles and contemporary uses in retinal investigation
-
DOI 10.1038/sj.eye.6700729
-
D. Thomas and G. Duguid, "Optical coherence tomography-a review of the principles and contemporary uses in retinal investigation," Eye 18(6), 561-570 (2004). (Pubitemid 38961447)
-
(2004)
Eye
, vol.18
, Issue.6
, pp. 561-570
-
-
Thomas, D.1
Duguid, G.2
-
38
-
-
2942703877
-
Measurement and imaging of water concentration in human cornea with differential absorption optical coherence tomography
-
M. Pircher, E. Götzinger, R. Leitgeb, A. F. Fercher, and C. K. Hitzenberger, "Measurement and imaging of water concentration in human cornea with differential absorption optical coherence tomography," Opt. Express 11(18), 2190-2197 (2003).
-
(2003)
Opt. Express
, vol.11
, Issue.18
, pp. 2190-2197
-
-
Pircher, M.1
Götzinger, E.2
Leitgeb, R.3
Fercher, A.F.4
Hitzenberger, C.K.5
-
39
-
-
0036875304
-
Indocyanine green-mediated photothrombosis as a new technique of treatment for persistent central serous chorioretinopathy
-
DOI 10.1076/ceyr.25.5.287.13496
-
R. A. Costa, L. Scapucin, N. S. Moraes, D. Calucci, L. A. Melo, J. A. Cardillo, and M. E. Farah, "Indocyanine green-mediated photothrombosis as a new technique of treatment for persistent central serous chorioretinopathy, " Curr. Eye Res. 25(5), 287-297 (2002). (Pubitemid 36408269)
-
(2002)
Current Eye Research
, vol.25
, Issue.5
, pp. 287-297
-
-
Costa, R.A.1
Scapucin, L.2
Moraes, N.S.3
Calucci, D.4
Melo Jr., L.A.5
Cardillo, J.A.6
Farah, M.E.7
-
40
-
-
1542742166
-
Reduction of diabetic macular edema by oral administration of the kinase inhibitor PKC412
-
DOI 10.1167/iovs.03-0955
-
P. A. Campochiaro, "Reduction of diabetic macular edema by oral administration of the kinase inhibitor PKC412," Invest. Ophthalmol. Visual Sci. 45(3), 922-931 (2004). (Pubitemid 38868393)
-
(2004)
Investigative Ophthalmology and Visual Science
, vol.45
, Issue.3
, pp. 922-931
-
-
Campochiaro, P.A.1
-
41
-
-
20144372969
-
Systemic bevacizumab (Avastin) therapy for neovascular age-related macular degeneration: Twelve-week results of an uncontrolled open-label clinical study
-
DOI 10.1016/j.ophtha.2005.02.007, PII S0161642005002976
-
S. Michels, P. J. Rosenfeld, C. A. Puliafito, E. N. Marcus, and A. S. Venkatraman, "Systemic bevacizumab (avastin) therapy for neovascular age-related macular degeneration: Twelve-week results of an uncontrolled open-label clinical study," Ophthalmology 112(6), 1035-1047 (2005). (Pubitemid 40797459)
-
(2005)
Ophthalmology
, vol.112
, Issue.6
, pp. 1035-1047
-
-
Michels, S.1
Rosenfeld, P.J.2
Puliafito, C.A.3
Marcus, E.N.4
Venkatraman, A.S.5
-
42
-
-
24944566042
-
Comparison of intravitreal versus posterior sub-Tenon's capsule injection of triamcinolone acetonide for diffuse diabetic macular edema
-
DOI 10.1016/j.ophtha.2005.03.023, PII S0161642005005956
-
J. A. Cardillo, L. A. S. Melo, R. A. Costa, M. Skaf, R. Belfort, A. A. Souza-Filho, M. E. Farah, and B. D. Kuppermann, "Comparison of intravitreal versus posterior sub-tenon's capsule injection of triamcinolone acetonide for diffuse diabetic macular edema," Ophthalmology 112(9), 1557-1563 (2005). (Pubitemid 41725412)
-
(2005)
Ophthalmology
, vol.112
, Issue.9
, pp. 1557-1563
-
-
Cardillo, J.A.1
Melo Jr., L.A.S.2
Costa, R.A.3
Skaf, M.4
Belfort Jr., R.5
Souza-Filho, A.A.6
Farah, M.E.7
Kuppermann, B.D.8
-
43
-
-
32944465175
-
Intravitreal injection versus sub-tenon's infusion of triamcinolone acetonide for refractory diabetic macular edema: A randomized clinical trial
-
DOI 10.1167/iovs.05-0297
-
M. A. Bonini-Filho, R. Jorge, J. C. Barbosa, D. Calucci, J. A. Cardillo, and R. A. Costa, "Intravitreal injection versus sub-tenon's infusion of triamcinolone acetonide for refractory diabetic macular edema: A randomized clinical trial," Invest. Ophthalmol. Visual Sci. 46(10), 3845-3849 (2005). (Pubitemid 44264695)
-
(2005)
Investigative Ophthalmology and Visual Science
, vol.46
, Issue.10
, pp. 3845-3849
-
-
Bonini-Filho, M.A.1
Jorge, R.2
Barbosa, J.C.3
Calucci, D.4
Cardillo, J.A.5
Costa, R.A.6
-
44
-
-
24344458089
-
Comparison of fluorescein angiography and optical coherence tomography for patients with choroidal neovascularization after photodynamic therapy
-
DOI 10.1097/00006982-200509000-00002
-
N. Eter, and R. F. Spaide, "Comparison of fluorescein angiography and optical coherence tomography for patients with choroidal neovascularization after photodynamic therapy," Retina 25(6), 691-696 (2005). (Pubitemid 41254537)
-
(2005)
Retina
, vol.25
, Issue.6
, pp. 691-696
-
-
Eter, N.1
Spaide, R.F.2
-
45
-
-
22444440577
-
Using optical coherence tomography to monitor photodynamic therapy in age related macular degeneration
-
A. Salinas-Alamán, A. García-Layana, M. J. Maldonado, C. Sainz- Gómez, and A. Alvárez-Vidal, "Using optical coherence tomography to monitor photodynamic therapy in age related macular degeneration," Am. J. Ophthalmol. 140(1), 23-28 (2005).
-
(2005)
Am. J. Ophthalmol.
, vol.140
, Issue.1
, pp. 23-28
-
-
Salinas-Alamán, A.1
García-Layana, A.2
Maldonado, M.J.3
Sainz-Gómez, C.4
Alvárez-Vidal, A.5
-
46
-
-
14744274207
-
Optical coherence tomography in photodynamic therapy for subfoveal choroidal neovascularisation secondary to age related macular degeneration: A cross sectional study
-
DOI 10.1136/bjo.2004.043364
-
J. Sahni, P. Stanga, D. Wong, and S. Harding, "Optical coherence tomography in photodynamic therapy for subfoveal choroidal neovascularisation secondary to age related macular degeneration: a cross sectional study," Br. J. Ophthamol. 89(3), 316-320 (2005). (Pubitemid 40327616)
-
(2005)
British Journal of Ophthalmology
, vol.89
, Issue.3
, pp. 316-320
-
-
Sahni, J.1
Stanga, P.2
Wong, D.3
Harding, S.4
-
47
-
-
1942423868
-
Threedimensional imaging of the human retina by high-speed optical coherence tomography
-
C. K. Hitzenberger, P. Trost, P. W. Lo, and Q. Zhou, " Threedimensional imaging of the human retina by high-speed optical coherence tomography," Opt. Express 11(21), 2753-2761 (2003).
-
(2003)
Opt. Express
, vol.11
, Issue.21
, pp. 2753-2761
-
-
Hitzenberger, C.K.1
Trost, P.2
Lo, P.W.3
Zhou, Q.4
-
48
-
-
33846860376
-
Human macula investigated in vivo with polarization-sensitive optical coherence tomography
-
M. Pircher, E. Götzinger, O. Findl, S. Michels, W. Geitzenauer, C. Leydolt, U. Schmidt-Erfurth, and C. K. Hitzenberger, "Human macula investigated in vivo with polarization-sensitive optical coherence tomography," Invest. Ophthalmol. Visual Sci. 47(12), 5487-5495 (2006).
-
(2006)
Invest. Ophthalmol. Visual Sci.
, vol.47
, Issue.12
, pp. 5487-5495
-
-
Pircher, M.1
Götzinger, E.2
Findl, O.3
Michels, S.4
Geitzenauer, W.5
Leydolt, C.6
Schmidt-Erfurth, U.7
Hitzenberger, C.K.8
-
49
-
-
12144290558
-
Measurement and imaging of birefringent properties of the human cornea with phase-resolved, polarization-sensitive optical coherence tomography
-
E. Götzinger, M. Pircher, M. Sticker, A. F. Fercher, and C. K. Hitzenberger, "Measurement and imaging of birefringent properties of the human cornea with phase-resolved, polarization-sensitive optical coherence tomography," J. Biomed. Opt. 9(1), 94-102 (2004).
-
(2004)
J. Biomed. Opt.
, vol.9
, Issue.1
, pp. 94-102
-
-
Götzinger, E.1
Pircher, M.2
Sticker, M.3
Fercher, A.F.4
Hitzenberger, C.K.5
-
50
-
-
22744451636
-
Adaptive optics parallel spectral domain optical coherence tomography for imaging the living retina
-
DOI 10.1364/OPEX.13.004792
-
Y. Zhang, J. Rha, R. S. Jonnal, and D. T. Miller, "Adaptive optics parallel spectral domain optical coherence tomography for imaging the living retina," Opt. Express 13(12), 4792-4811 (2005). (Pubitemid 41029403)
-
(2005)
Optics Express
, vol.13
, Issue.12
, pp. 4792-4811
-
-
Zhang, Y.1
Rha, J.2
Jonnal, R.S.3
Miller, D.T.4
-
51
-
-
26844495794
-
Adaptive-optics optical coherence tomography for high-resolution and high-speed 3D retinal in vivo imaging
-
R. J. Zawadzki, S. M. Jones, S. S. Olivier, M. Zhao, B. A. Bower, J. A. Izatt, S. Choi, S. Laut, and J. S. Werner, "Adaptive-optics optical coherence tomography for high-resolution and high-speed 3D retinal in vivo imaging," Opt. Express 13(21), 8532-8546 (2005).
-
(2005)
Opt. Express
, vol.13
, Issue.21
, pp. 8532-8546
-
-
Zawadzki, R.J.1
Jones, S.M.2
Olivier, S.S.3
Zhao, M.4
Bower, B.A.5
Izatt, J.A.6
Choi, S.7
Laut, S.8
Werner, J.S.9
-
52
-
-
33645518036
-
Optophysiology: Depth-resolved probing of retinal physiology with functional ultrahigh-resolution optical coherence tomography
-
K. Bizheva, R. Pflug, B. Hermann, B. Považay, H. Sattmann, P. Qiu, E. Anger, H. Reitsamer, S. Popov, J. R. Taylor, A. Unterhuber, P. Ahnelt, and W. Drexler, "Optophysiology: Depth-resolved probing of retinal physiology with functional ultrahigh-resolution optical coherence tomography," Proc. Natl. Acad. Sci. U.S.A. 103(13), 5066-5071 (2006).
-
(2006)
Proc. Natl. Acad. Sci. U.S.A.
, vol.103
, Issue.13
, pp. 5066-5071
-
-
Bizheva, K.1
Pflug, R.2
Hermann, B.3
Považay, B.4
Sattmann, H.5
Qiu, P.6
Anger, E.7
Reitsamer, H.8
Popov, S.9
Taylor, J.R.10
Unterhuber, A.11
Ahnelt, P.12
Drexler, W.13
-
53
-
-
0035991794
-
Clinical imaging with optical coherence tomography
-
DOI 10.1016/S1076-6332(03)80465-8
-
B. E. Bouma and G. J. Tearney, "Clinical imaging with optical coherence tomography," Acad. Radiol. 9(8), 942-953 (2002). (Pubitemid 34856288)
-
(2002)
Academic Radiology
, vol.9
, Issue.8
, pp. 942-953
-
-
Bouma, B.E.1
Tearney, G.J.2
-
54
-
-
0037369227
-
Evaluation of intracoronary stenting by intravascular optical coherence tomography
-
B. E. Bouma, G. J. Tearney, H. Yabushita, M. Shishkov, C. R. Kauffman, D. DeJoseph Gauthier, B. D. MacNeill, S. L. Houser, H. T. Aretz, E. F. Halpern, and I. K. Jang, "Evaluation of intracoronary stenting by intravascular optical coherence tomography," Heart 89(3), 317-320 (2003). (Pubitemid 36241548)
-
(2003)
Heart
, vol.89
, Issue.3
, pp. 317-320
-
-
Bouma, B.E.1
Tearney, G.J.2
Yabushita, H.3
Shishkov, M.4
Kauffman, C.R.5
DeJoseph Gauthier, D.6
MacNeill, B.D.7
Houser, S.L.8
Aretz, H.T.9
Halpern, E.F.10
Jang, I.-K.11
-
55
-
-
0029883944
-
Optical coherence tomography for optical biopsy: Properties and demonstration of vascular pathology
-
M. E. Brezinski, G. J. Tearney, B. E. Bouma, J. A. Izatt, M. R. Hee, E. A. Swanson, J. F. Southern, and J. G. Fujimoto, "Optical coherence tomography for optical biopsy: Properties and demonstration of vascular pathology," Circulation 93(6), 1206-1213 (1996). (Pubitemid 26087024)
-
(1996)
Circulation
, vol.93
, Issue.6
, pp. 1206-1213
-
-
Brezinski, M.E.1
Tearney, G.J.2
Bouma, B.E.3
Izatt, J.A.4
Hee, M.R.5
Swanson, E.A.6
Southern, J.F.7
Fujimoto, J.G.8
-
56
-
-
0030045636
-
Imaging of coronary artery microstructure (in vitro) with optical coherence tomography
-
DOI 10.1016/S0002-9149(97)89143-6
-
M. E. Brezinski, G. J. Tearney, B. E. Bouma, S. A. Boppart, M. R. Hee, E. A. Swanson, J. F. Southern, and J. G. Fujimoto, "Imaging of coronary artery microstructure (in vitro) with optical coherence tomography," Am. J. Cardiol. 77(1), 92-93 (1996). (Pubitemid 26011641)
-
(1996)
American Journal of Cardiology
, vol.77
, Issue.1
, pp. 92-93
-
-
Brezinski, M.E.1
Tearney, G.J.2
Bouma, B.E.3
Boppart, S.A.4
Hee, M.R.5
Swanson, E.A.6
Southern, J.F.7
Fujimoto, J.G.8
-
57
-
-
8544273292
-
Assessing atherosclerotic plaque morphology: Comparison of optical coherence tomography and high frequency intravascular ultrasound
-
M. E. Brezinski, G. J. Tearney, N. J. Weissman, S. A. Boppart, B. E. Bouma, M. R. Hee, A. E. Weyman, E. A. Swanson, J. F. Southern, and J. G. Fujimoto, "Assessing atherosclerotic plaque morphology: comparison of optical coherence tomography and high frequency intravascular ultrasound," Heart 77(5), 397-403 (1997). (Pubitemid 27278414)
-
(1997)
Heart
, vol.77
, Issue.5
, pp. 397-403
-
-
Brezinski, M.E.1
Tearney, G.J.2
Weissman, N.J.3
Boppart, S.A.4
Bouma, B.E.5
Hee, M.R.6
Weyman, A.E.7
Swanson, E.A.8
Southern, J.F.9
Fujimoto, J.G.10
-
58
-
-
11044234156
-
Mechanical analysis of atherosclerotic plaques based on optical coherence tomography
-
DOI 10.1114/B:ABME.0000049034.75368.4a
-
A. H. Chau, R. C. Chan, M. Shishkov, B. MacNeill, N. Iftimia, G. J. Tearney, R. D. Kamm, B. E. Bouma, and M. R. Kaazempur-Mofrad, "Mechanical analysis of atherosclerotic plaques based on optical coherence tomography," Ann. Biomed. Eng. 32(11), 1494-1503 (2004). (Pubitemid 40044496)
-
(2004)
Annals of Biomedical Engineering
, vol.32
, Issue.11
, pp. 1494-1503
-
-
Chau, A.H.1
Chan, R.C.2
Shishkov, M.3
Macneill, B.4
Iftimia, N.5
Tearney, G.J.6
Kamm, R.D.7
Bouma, B.E.8
Kaazempur-Mofrad, M.R.9
-
59
-
-
0032782052
-
High resolution in vivo intra-arterial imaging with optical coherence tomography
-
J. G. Fujimoto, S. A. Boppart, G. J. Tearney, B. E. Bouma, C. Pitris, and M. E. Brezinski, "High resolution in vivo intra-arterial imaging with optical coherence tomography," Heart 82(2), 128-133 (1999). (Pubitemid 29362857)
-
(1999)
Heart
, vol.82
, Issue.2
, pp. 128-133
-
-
Fujimoto, J.G.1
Boppart, S.A.2
Tearney, G.J.3
Bouma, B.E.4
Pitris, C.5
Brezinski, M.E.6
-
60
-
-
0036152314
-
Imaging of the atrioventricular node using optical coherence tomography
-
M. Gupta, A. M. Rollins, J. A. Izatt, and I. R. Efimov, "Imaging of the atrioventricular node using optical coherence tomography," J. Cardiovasc. Electrophysiol. 13(1), 95 (2002). (Pubitemid 34113631)
-
(2002)
Journal of Cardiovascular Electrophysiology
, vol.13
, Issue.1
, pp. 95
-
-
Gupta, M.1
Rollins, A.M.2
Izatt, J.A.3
Efimov, I.R.4
-
61
-
-
0035960591
-
Visualization of tissue prolapse between coronary stent struts by optical coherence tomography: Comparison with intravascular Ultrasound
-
I. K. Jang, G. Tearney, and B. Bouma, "Visualization of tissue prolapse between coronary stent struts by optical coherence tomography: Comparison with intravascular ultrasound," Circulation 104(22), 2754 (2001). (Pubitemid 33108146)
-
(2001)
Circulation
, vol.104
, Issue.22
, pp. 2754
-
-
Jang, I.-K.1
Tearney, G.2
Bouma, B.3
-
62
-
-
0037138571
-
Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: Comparison with intravascular ultrasound
-
DOI 10.1016/S0735-1097(01)01799-5, PII S0735109701017995
-
I. K. Jang, B. E. Bouma, D. H. Kang, S. J. Park, S. W. Park, K. B. Seung, K. B. Choi, M. Shishkov, K. Schlendorf, E. Pomerantsev, S. L. Houser, H. T. Aretz, and G. J. Tearney, "Visualization of coronary atherosclerotic plaques in patients using optical coherence tomography: comparison with intravascular ultrasound," J. Am. Coll. Cardiol. 39(4), 604-609 (2002). (Pubitemid 34158155)
-
(2002)
Journal of the American College of Cardiology
, vol.39
, Issue.4
, pp. 604-609
-
-
Jang, I.-K.1
Bouma, B.E.2
Kang, D.-H.3
Park, S.-J.4
Park, S.-W.5
Seung, K.-B.6
Choi, K.-B.7
Shishkov, M.8
Schlendorf, K.9
Pomerantsev, E.10
Houser, S.L.11
Aretz H.Thomas12
Tearney, G.J.13
-
63
-
-
20144388778
-
In vivo characterization of coronary atherosclerotic plaque by use of optical coherence tomography
-
DOI 10.1161/01.CIR.0000159354.43778.69
-
I. K. Jang, G. J. Tearney, B. MacNeill, M. Takano, F. Moselewski, N. Iftima, M. Shishkov, S. Houser, H. T. Aretz, E. F. Halpern, and B. E. Bouma, "In vivo characterization of coronary atherosclerotic plaque by use of optical coherence tomography," Circulation 111(12), 1551-1555 (2005). (Pubitemid 40470652)
-
(2005)
Circulation
, vol.111
, Issue.12
, pp. 1551-1555
-
-
Jang, I.-K.1
Tearney, G.J.2
MacNeill, B.3
Takano, M.4
Moselewski, F.5
Iftima, N.6
Shishkov, M.7
Houser, S.8
Aretz, H.T.9
Halpern, E.F.10
Bouma, B.E.11
-
64
-
-
4444281029
-
Focal and multi-focal plaque macrophage distributions in patients with acute and stable presentations of coronary artery disease
-
DOI 10.1016/j.jacc.2004.05.066, PII S073510970401215X
-
B. D. MacNeill, I. K. Jang, B. E. Bouma, N. Iftimia, M. Takano, H. Yabushita, M. Shishkov, C. R. Kauffman, S. L. Houser, H. T. Aretz, D. DeJoseph, E. F. Halpern, and G. J. Tearney, "Focal and multi-focal plaque macrophage distributions in patients with acute and stable presentations of coronary artery disease," J. Am. Coll. Cardiol. 44(5), 972-979 (2004). (Pubitemid 39165129)
-
(2004)
Journal of the American College of Cardiology
, vol.44
, Issue.5
, pp. 972-979
-
-
MacNeill, B.D.1
Jang, I.-K.2
Bouma, B.E.3
Iftimia, N.4
Takano, M.5
Yabushita, H.6
Shishkov, M.7
Kauffman, C.R.8
Houser, S.L.9
Aretz, H.T.10
Dejoseph, D.11
Halpern, E.F.12
Tearney, G.J.13
-
65
-
-
85046113654
-
Catheter-based optical imaging of a human coronary artery
-
G. J. Tearney, M. E. Brezinski, S. A. Boppart, B. E. Bouma, N. Weissman, J. F. Southern, E. A. Swanson, and J. G. Fujimoto, "Catheter-based optical imaging of a human coronary artery," Circulation 94(11), 3013 (1996). (Pubitemid 26411789)
-
(1996)
Circulation
, vol.94
, Issue.11
, pp. 3013
-
-
Tearney, G.J.1
Brezinski, M.E.2
Boppart, S.A.3
Bouma, B.E.4
Weissman, N.5
Southern, J.F.6
Swanson, E.A.7
Fujimoto, J.G.8
-
66
-
-
0030760309
-
In vivo endoscopic optical biopsy with optical coherence tomography
-
DOI 10.1126/science.276.5321.2037
-
G. J. Tearney, M. E. Brezinski, B. E. Bouma, S. A. Boppart, C. Pitris, J. F. Southern, and J. G. Fujimoto, "In vivo endoscopic optical biopsy with optical coherence tomography," Science 276(5321), 2037-2039 (1997). (Pubitemid 27443607)
-
(1997)
Science
, vol.276
, Issue.5321
, pp. 2037-2039
-
-
Tearney, G.J.1
Brezinski, M.E.2
Bouma, B.E.3
Boppart, S.A.4
Pitris, C.5
Southern, J.F.6
Fujimoto, J.G.7
-
68
-
-
0037422532
-
Quantification of macrophage content in atherosclerotic plaques by optical coherence tomography
-
DOI 10.1161/01.CIR.0000044384.41037.43
-
G. J. Tearney, H. Yabushita, S. L. Houser, H. T. Aretz, I. K. Jang, K. H. Schlendorf, C. R. Kauffman, M. Shishkov, E. F. Halpern, and B. E. Bouma, "Quantification of macrophage content in atherosclerotic plaques by optical coherence tomography," Circulation 107(1), 113-119 (2003). (Pubitemid 36070942)
-
(2003)
Circulation
, vol.107
, Issue.1
, pp. 113-119
-
-
Tearney, G.J.1
Yabushita, H.2
Houser, S.L.3
Aretz, H.T.4
Jang, I.-K.5
Schlendorf, K.H.6
Kauffman, C.R.7
Shishkov, M.8
Halpern, E.F.9
Bouma, B.E.10
-
69
-
-
0037167693
-
Characterization of human atherosclerosis by optical coherence tomography
-
H. Yabushita, B. E. Bouma, S. L. Houser, H. T. Aretz, I. K. Jang, K. H. Schlendorf, C. R. Kauffman, M. Shishkov, D. H. Kang, E. F. Halpern, and G. J. Tearney, "Characterization of human atherosclerosis by optical coherence tomography," Circulation 106(13), 1640-1645 (2002).
-
(2002)
Circulation
, vol.106
, Issue.13
, pp. 1640-1645
-
-
Yabushita, H.1
Bouma, B.E.2
Houser, S.L.3
Aretz, H.T.4
Jang, I.K.5
Schlendorf, K.H.6
Kauffman, C.R.7
Shishkov, M.8
Kang, D.H.9
Halpern, E.F.10
Tearney, G.J.11
-
70
-
-
0037180459
-
Optical coherence tomography: A new high-resolution imaging technology to study cardiac development in chick embryos
-
DOI 10.1161/01.CIR.0000042672.51054.7B
-
T. M. Yelbuz, M. A. Choma, L. Thrane, M. L. Kirby, and J. A. Izatt, "Optical coherence tomography: a new high-resolution imaging technology to study cardiac development in chick embryos," Circulation 106(22), 2771-2774 (2002). (Pubitemid 35396974)
-
(2002)
Circulation
, vol.106
, Issue.22
, pp. 2771-2774
-
-
Yelbuz, T.M.1
Choma, M.A.2
Thrane, L.3
Kirby, M.L.4
Izatt, J.A.5
-
71
-
-
33746413928
-
Threedimensional optical coherence tomography of the embryonic murine cardiovascular system
-
W. Luo, D. L. Marks, T. S. Ralston, and S. A. Boppart, "Threedimensional optical coherence tomography of the embryonic murine cardiovascular system," J. Biomed. Opt. 11(2), 021014 (2006).
-
(2006)
J. Biomed. Opt.
, vol.11
, Issue.2
, pp. 021014
-
-
Luo, W.1
Marks, D.L.2
Ralston, T.S.3
Boppart, S.A.4
-
73
-
-
0344152358
-
Threedimensional spectrally encoded imaging
-
D. Yelin, B. E. Bouma, N. Iftimia, and G. J. Tearney, "Threedimensional spectrally encoded imaging," Opt. Lett. 28(23), 2321-2323 (2003).
-
(2003)
Opt. Lett.
, vol.28
, Issue.23
, pp. 2321-2323
-
-
Yelin, D.1
Bouma, B.E.2
Iftimia, N.3
Tearney, G.J.4
-
75
-
-
33746413498
-
Optical coherence tomography for imaging the vulnerable plaque
-
G. J. Tearney, I. K. Jang, and B. E. Bouma, "Optical coherence tomography for imaging the vulnerable plaque," J. Biomed. Opt. 11(2), 021002 (2006).
-
(2006)
J. Biomed. Opt.
, vol.11
, Issue.2
, pp. 021002
-
-
Tearney, G.J.1
Jang, I.K.2
Bouma, B.E.3
-
76
-
-
23244447858
-
Intravascular optical coherence tomography: Cellular imaging
-
DOI 10.1016/j.nuclcard.2005.05.013, PII S1071358105002096
-
B. D. MacNeill, B. E. Bouma, H. Yabushita, I. K. Jang, and G. J. Tearney, "Intravascular optical coherence tomography: cellular imaging," J. Nucl. Cardiol. 12(4), 460-465 (2005). (Pubitemid 41093763)
-
(2005)
Journal of Nuclear Cardiology
, vol.12
, Issue.4
, pp. 460-465
-
-
MacNeill, B.D.1
Bouma, B.E.2
Yabushita, H.3
Jang, I.-K.4
Tearney, G.J.5
-
77
-
-
23744458331
-
Assessment of coronary intima - Media thickness by optical coherence tomography: Comparison with intravascular ultrasound
-
DOI 10.1253/circj.69.903
-
T. Kume, T. Akasaka, T. Kawamoto, N. Watanabe, E. Toyota, Y. Neishi, R. Sukmawan, Y. Sadahira, and K. Yoshida, "Assessment of coronary intima-media thickness by optical coherence tomography: comparison with intravascular ultrasound," Jpn. Circ. J. 69(8), 903-907 (2005). (Pubitemid 41124256)
-
(2005)
Circulation Journal
, vol.69
, Issue.8
, pp. 903-907
-
-
Kume, T.1
Akasaka, T.2
Kawamoto, T.3
Watanabe, N.4
Toyota, E.5
Neishi, Y.6
Sukmawan, R.7
Sadahira, Y.8
Yoshida, K.9
-
78
-
-
33748684390
-
Measurement of the thickness of the fibrous cap by optical coherence tomography
-
T. Kume, T. Akasaka, T. Kawamoto, H. Okura, N. Watanabe, E. Toyota, Y. Neishi, R. Sukmawan, Y. Sadahira, and K. Yoshida, "Measurement of the thickness of the fibrous cap by optical coherence tomography," Am. Heart J. 152(4), 755e1-755e4 (2006).
-
(2006)
Am. Heart J.
, vol.152
, Issue.4
-
-
Kume, T.1
Akasaka, T.2
Kawamoto, T.3
Okura, H.4
Watanabe, N.5
Toyota, E.6
Neishi, Y.7
Sukmawan, R.8
Sadahira, Y.9
Yoshida, K.10
-
79
-
-
23844462977
-
Localized measurement of optical attenuation coefficients of atherosclerotic plaque constituents by quantitative optical coherence tomography
-
DOI 10.1109/TMI.2005.854297
-
F. J. van der Meer, D. J. Faber, D. M. B. Sassoon, M. C. Aalders, G. Pasterkamp, and T. G. van Leeuwen, "Localized measurement of optical attenuation coefficients of atherosclerotic plaque constituents by quantitative optical coherence tomography," IEEE Trans. Med. Imaging 24(10), 1369-1376 (2005). (Pubitemid 41463573)
-
(2005)
IEEE Transactions on Medical Imaging
, vol.24
, Issue.10
, pp. 1369-1376
-
-
Van Der Meer, F.J.1
Faber, D.J.2
Sassoon, D.M.B.3
Aalders, M.C.4
Pasterkamp, G.5
Van Leeuwen, T.G.6
-
80
-
-
23844528861
-
Quantitative optical coherence tomography of arterial wall components
-
DOI 10.1007/s10103-005-0336-z
-
F. J. van der Meer, D. J. Faber, J. Perrée, G. Pasterkamp, D. B. Sassoon, and T. G. van Leeuwen, "Quantitative optical coherence tomography of arterial wall components," Lasers Med. Sci. 20(1), 45-51 (2005). (Pubitemid 41175884)
-
(2005)
Lasers in Medical Science
, vol.20
, Issue.1
, pp. 45-51
-
-
Van Der Meer, F.J.1
Faber, D.J.2
Perree, J.3
Pasterkamp, G.4
Baraznji Sassoon, D.5
Van Leeuwen, T.G.6
-
81
-
-
84894125558
-
OCT-guided wiring technique for chronic total coronary occlusion
-
E. Regar, T. G. van Leeuwen, and P. W. Serruys, Eds., Informa Healthcare, London
-
Y. Takeda and O. Katoh, "OCT-guided wiring technique for chronic total coronary occlusion," in Optical Coherence Tomography in Cardiovascular Research, E. Regar, T. G. van Leeuwen, and P. W. Serruys, Eds., pp. 183-190, Informa Healthcare, London (2007).
-
(2007)
Optical Coherence Tomography in Cardiovascular Research
, pp. 183-190
-
-
Takeda, Y.1
Katoh, O.2
-
82
-
-
84894160198
-
Chronic total occlusion: Do we need intravascular imaging guidance?
-
E. Regar, T. G. van Leeuwen, and P. W. Serruys, Eds., Informa Healthcare, London
-
J. Tanigawa, O. Katoh, and C. Di Mario, "Chronic total occlusion: do we need intravascular imaging guidance?" in Optical Coherence Tomography in Cardiovascular Research, E. Regar, T. G. van Leeuwen, and P. W. Serruys, Eds., pp. 171-182, Informa Healthcare, London (2007).
-
(2007)
Optical Coherence Tomography in Cardiovascular Research
, pp. 171-182
-
-
Tanigawa, J.1
Katoh, O.2
Di Mario, C.3
-
83
-
-
30444458360
-
Visualization of neointima formation by optical coherence tomography
-
T. Kume, T. Akasaka, T. Kawamoto, N. Watanabe, E. Toyota, R. Sukmawan, Y. Sadahira, and K. Yoshida, "Visualization of neointima formation by optical coherence tomography," Intl. Heart J. 46(6), 1133-1136 (2005).
-
(2005)
Intl. Heart J.
, vol.46
, Issue.6
, pp. 1133-1136
-
-
Kume, T.1
Akasaka, T.2
Kawamoto, T.3
Watanabe, N.4
Toyota, E.5
Sukmawan, R.6
Sadahira, Y.7
Yoshida, K.8
-
84
-
-
33644874009
-
Optical coherence tomography findings at 5-year follow-up after coronary stent implantation
-
DOI 10.1161/CIRCULATIONAHA.104.531897, PII 0000301720051206000023
-
E. Regar, H. M. M. van Beusekom, W. J. van der Giessen, and P. W. Serruys, "Optical coherence tomography findings at 5-year follow-up after coronary stent implantation," Circulation 112(23), e345-e346 (2005). (Pubitemid 43739524)
-
(2005)
Circulation
, vol.112
, Issue.23
-
-
Regar, E.1
Van Beusekom, H.M.M.2
Van Der Giessen, W.J.3
Serruys, P.W.4
-
85
-
-
84894115531
-
Acute OCT findings after stenting
-
E. Regar, T. G. van Leeuwen, and P. W. Serruys, Eds. , Informa Healthcare, London
-
J. F. Surmely, Y. Takeda, T. Ito, and T. Suzuki, "Acute OCT findings after stenting," in Optical Coherence Tomography in Cardiovascular Research, E. Regar, T. G. van Leeuwen, and P. W. Serruys, Eds., pp. 153-160, Informa Healthcare, London(2007).
-
(2007)
Optical Coherence Tomography in Cardiovascular Research
, pp. 153-160
-
-
Surmely, J.F.1
Takeda, Y.2
Ito, T.3
Suzuki, T.4
-
86
-
-
14844321247
-
Molecularly sensitive optical coherence tomography
-
DOI 10.1364/OL.30.000495
-
J. S. Bredfeldt, C. Vinegoni, D. L. Marks, and S. A. Boppart, "Molecularly sensitive optical coherence tomography," Opt. Lett. 30(5), 495-497 (2005). (Pubitemid 40339491)
-
(2005)
Optics Letters
, vol.30
, Issue.5
, pp. 495-497
-
-
Bredfeldt, J.S.1
Vinegoni, C.2
Marks, D.L.3
Boppart, S.A.4
-
87
-
-
0041808915
-
Functional optical coherence tomography for detecting neural activity through scattering changes
-
M. Lazebnik, D. L. Marks, K. Potgieter, R. Gillette, and S. A. Boppart, "Functional optical coherence tomography for detecting neural activity through scattering changes," Opt. Lett. 28(14), 1218-1220 (2003).
-
(2003)
Opt. Lett.
, vol.28
, Issue.14
, pp. 1218-1220
-
-
Lazebnik, M.1
Marks, D.L.2
Potgieter, K.3
Gillette, R.4
Boppart, S.A.5
-
88
-
-
0042787989
-
Engineered microsphere contrast agents for optical coherence tomography
-
T. M. Lee, A. L. Oldenburg, S. Sitafalwalla, D. L. Marks, W. Luo, F. J. J. Toublan, K. S. Suslick, and S. A. Boppart, "Engineered microsphere contrast agents for optical coherence tomography," Opt. Lett. 28(17), 1546-1548 (2003).
-
(2003)
Opt. Lett.
, vol.28
, Issue.17
, pp. 1546-1548
-
-
Lee, T.M.1
Oldenburg, A.L.2
Sitafalwalla, S.3
Marks, D.L.4
Luo, W.5
Toublan, F.J.J.6
Suslick, K.S.7
Boppart, S.A.8
-
89
-
-
85032425798
-
Nonlinear interferometric vibrational imaging
-
D. L. Marks and S. A. Boppart, "Nonlinear interferometric vibrational imaging," Phys. Rev. Lett. 92(12), 123905 (2004).
-
(2004)
Phys. Rev. Lett.
, vol.92
, Issue.12
, pp. 123905
-
-
Marks, D.L.1
Boppart, S.A.2
-
90
-
-
16244419054
-
Imaging magnetically labeled cells with magnetomotive optical coherence tomography
-
DOI 10.1364/OL.30.000747
-
A. L. Oldenburg, J. R. Gunther, and S. A. Boppart, "Imaging magnetically labeled cells with magnetomotive optical coherence tomography," Opt. Lett. 30(7), 747-749 (2005). (Pubitemid 40449066)
-
(2005)
Optics Letters
, vol.30
, Issue.7
, pp. 747-749
-
-
Oldenburg, A.L.1
Gunther, J.R.2
Boppart, S.A.3
-
91
-
-
0037364156
-
Molecular contrast in optical coherence tomography by use of a pump-probe technique
-
K. D. Rao, M. A. Choma, S. Yazdanfar, A. M. Rollins, and J. A. Izatt, "Molecular contrast in optical coherence tomography by use of a pump-probe technique," Opt. Lett. 28(5), 340-342 (2003).
-
(2003)
Opt. Lett.
, vol.28
, Issue.5
, pp. 340-342
-
-
Rao, K.D.1
Choma, M.A.2
Yazdanfar, S.3
Rollins, A.M.4
Izatt, J.A.5
-
93
-
-
3142760010
-
Near-infrared dyes as contrast-enhancing agents for spectroscopic optical coherence tomography
-
C. Xu, J. Ye, D. L. Marks, and S. A. Boppart, "Near-infrared dyes as contrast-enhancing agents for spectroscopic optical coherence tomography," Opt. Lett. 29(14), 1647-1649 (2004).
-
(2004)
Opt. Lett.
, vol.29
, Issue.14
, pp. 1647-1649
-
-
Xu, C.1
Ye, J.2
Marks, D.L.3
Boppart, S.A.4
-
94
-
-
2942550644
-
Protein-based molecular contrast optical coherence tomography with phytochrome as the contrast agent
-
C. Yang, M. A. Choma, L. E. Lamb, J. D. Simon, and J. A. Izatt, "Protein-based molecular contrast optical coherence tomography with phytochrome as the contrast agent," Opt. Lett. 29(12), 1396-1398 (2004).
-
(2004)
Opt. Lett.
, vol.29
, Issue.12
, pp. 1396-1398
-
-
Yang, C.1
Choma, M.A.2
Lamb, L.E.3
Simon, J.D.4
Izatt, J.A.5
-
95
-
-
4544365855
-
Spectral triangulation molecular contrast optical coherence tomography with indocyanine green as the contrast agent
-
C. Yang, L. E. L. McGuckin, J. D. Simon, M. A. Choma, B. E. Applegate, and J. A. Izatt, "Spectral triangulation molecular contrast optical coherence tomography with indocyanine green as the contrast agent," Opt. Lett. 29(17), 2016-2018 (2004).
-
(2004)
Opt. Lett.
, vol.29
, Issue.17
, pp. 2016-2018
-
-
Yang, C.1
McGuckin, L.E.L.2
Simon, J.D.3
Choma, M.A.4
Applegate, B.E.5
Izatt, J.A.6
-
96
-
-
17444412648
-
Molecular contrast optical coherence tomography: A review
-
DOI 10.1562/2004-08-06-IR-266.1
-
C. Yang, "Molecular contrast optical coherence tomography: A review," Photochem. Photobiol. 81(2), 215-237 (2005). (Pubitemid 40551497)
-
(2005)
Photochemistry and Photobiology
, vol.81
, Issue.2
, pp. 215-237
-
-
Yang, C.1
-
97
-
-
33344474429
-
Assessment of coronary plaque collagen with polarization sensitive optical coherence tomography (PS-OCT)
-
DOI 10.1016/j.ijcard.2005.11.036, PII S0167527305013367
-
S. D. Giattina, B. K. Courtney, P. R. Herz, M. Harman, S. Shortkroff, D. L. Stamper, B. Liu, J. G. Fujimoto, and M. E. Brezinski, "Assessment of coronary plaque collagen with polarization sensitive optical coherence tomography (PS-OCT(," Int. J. Cardiol. 107(3), 400-409 (2006). (Pubitemid 43287788)
-
(2006)
International Journal of Cardiology
, vol.107
, Issue.3
, pp. 400-409
-
-
Giattina, S.D.1
Courtney, B.K.2
Herz, P.R.3
Harman, M.4
Shortkroff, S.5
Stamper, D.L.6
Liu, B.7
Fujimoto, J.G.8
Brezinski, M.E.9
-
98
-
-
34250352736
-
Polarization-sensitive optical coherence tomography for imaging human atherosclerosis
-
DOI 10.1364/AO.46.002520
-
W. C. Kuo, N. K. Chou, C. Chou, C. M. Lai, H. J. Huang, S. S. Wang, and J. J. Shyu, "Polarization-sensitive optical coherence tomography for imaging human atherosclerosis," Appl. Opt. 46(13), 2520-2527 (2007). (Pubitemid 46918396)
-
(2007)
Applied Optics
, vol.46
, Issue.13
, pp. 2520-2527
-
-
Kuo, W.-C.1
Chou, N.-K.2
Chou, C.3
Lai, C.-M.4
Huang, H.-J.5
Wang, S.-S.6
Shyu, J.-J.7
-
99
-
-
0242493238
-
Accurate measurement of total attenuation coefficient of thin tissue with optical coherence tomography
-
A. I. Kholodnykh, I. Y. Petrova, M. Motamedi, and R. O. Esenaliev, "Accurate measurement of total attenuation coefficient of thin tissue with optical coherence tomography," IEEE J. Sel. Top. Quantum Electron. 9(2), 210-221 (2003).
-
(2003)
IEEE J. Sel. Top. Quantum Electron.
, vol.9
, Issue.2
, pp. 210-221
-
-
Kholodnykh, A.I.1
Petrova, I.Y.2
Motamedi, M.3
Esenaliev, R.O.4
-
100
-
-
33751330979
-
Temperature-dependent optical properties of individual vascular wall components measured by optical coherence tomography
-
F. J. van der Meer, D. J. Faber, I. Çilesiz, M. J. C. Van Gemert, and T. G. van Leeuwen, "Temperature-dependent optical properties of individual vascular wall components measured by optical coherence tomography," J. Biomed. Opt. 11(4), 041120 (2006).
-
(2006)
J. Biomed. Opt.
, vol.11
, Issue.4
, pp. 041120
-
-
Van Der Meer, F.J.1
Faber, D.J.2
Çilesiz, I.3
Van Gemert, M.J.C.4
Van Leeuwen, T.G.5
-
101
-
-
1942468087
-
Optical coherence tomographic elastography technique for measuring deformation and strain of atherosclerotic tissues
-
J. Rogowska, N. A. Patel, J. G. Fujimoto, and M. E. Brezinski, "Optical coherence tomographic elastography technique for measuring deformation and strain of atherosclerotic tissues," Heart 90(5), 556-562 (2004). (Pubitemid 38530176)
-
(2004)
Heart
, vol.90
, Issue.5
, pp. 556-562
-
-
Rogowska, J.1
Patel, N.A.2
Fujimoto, J.G.3
Brezinski, M.E.4
-
102
-
-
33748261666
-
Quantitative optical coherence tomographic elastography: Method for assessing arterial mechanical properties
-
DOI 10.1259/bjr/22522280
-
J. Rogowska, N. Patel, S. Plummer, and M. E. Brezinski, "Quantitative optical coherence tomographic elastography: method for assessing arterial mechanical properties," Br. J. Radiol. 79(945), 707-711 (2006). (Pubitemid 44349510)
-
(2006)
British Journal of Radiology
, vol.79
, Issue.945
, pp. 707-711
-
-
Rogowska, J.1
Patel, N.2
Plummer, S.3
Brezinski, M.E.4
-
103
-
-
1642409838
-
Optical coherence tomography: Feasibility for basic research and image-guided surgery of breast cancer
-
DOI 10.1023/B:BREA.0000018401.13609.54
-
S. A. Boppart, W. Luo, D. L. Marks, and K. W. Singletary, "Optical coherence tomography: feasibility for basic research and imageguided surgery of breast cancer," Breast Cancer Res. Treat. 84(2), 85-97 (2004). (Pubitemid 38393359)
-
(2004)
Breast Cancer Research and Treatment
, vol.84
, Issue.2
, pp. 85-97
-
-
Boppart, S.A.1
Luo, W.2
Marks, D.L.3
Singletary, K.W.4
-
104
-
-
33845370158
-
Computational methods for analysis of human breast tumor tissue in optical coherence tomography images
-
A. M. Zysk and S. A. Boppart, "Computational methods for analysis of human breast tumor tissue in optical coherence tomography images," J. Biomed. Opt. 11(5), 054015 (2006).
-
(2006)
J. Biomed. Opt.
, vol.11
, Issue.5
, pp. 054015
-
-
Zysk, A.M.1
Boppart, S.A.2
-
105
-
-
33644789703
-
Separate cavity margin sampling at the time of initial breast lumpectomy significantly reduces the need for reexcisions
-
D. Cao, C. Lin, S. H. Woo, R. Vang, T. N. Tsangaris, and P. Argani, "Separate cavity margin sampling at the time of initial breast lumpectomy significantly reduces the need for reexcisions," Am. J. Surg. Pathol. 29(12), 1625-1632 (2005).
-
(2005)
Am. J. Surg. Pathol.
, vol.29
, Issue.12
, pp. 1625-1632
-
-
Cao, D.1
Lin, C.2
Woo, S.H.3
Vang, R.4
Tsangaris, T.N.5
Argani, P.6
-
106
-
-
34247328600
-
Portable real-time optical coherence tomography system for intraoperative imaging and staging of breast cancer
-
F. T. Nguyen, A. M. Zysk, J. G. Kotynek, F. J. Bellafiore, K. M. Rowland, P. A. Johnson, E. J. Chaney, and S. A. Boppart, "Portable real-time optical coherence tomography system for intraoperative imaging and staging of breast cancer," Proc. SPIE 6430, 64300H (2007).
-
(2007)
Proc. SPIE
, vol.6430
-
-
Nguyen, F.T.1
Zysk, A.M.2
Kotynek, J.G.3
Bellafiore, F.J.4
Rowland, K.M.5
Johnson, P.A.6
Chaney, E.J.7
Boppart, S.A.8
-
107
-
-
26844513311
-
Optical biopsy of lymph node morphology using optical coherence tomography
-
W. Luo, F. T. Nguyen, A. M. Zysk, T. S. Ralston, J. Brockenbrough, D. L. Marks, A. L. Oldenburg, and S. A. Boppart, "Optical biopsy of lymph node morphology using optical coherence tomography," Technol. Cancer Res. Treat. 4(5), 539-548 (2005).
-
(2005)
Technol. Cancer Res. Treat.
, vol.4
, Issue.5
, pp. 539-548
-
-
Luo, W.1
Nguyen, F.T.2
Zysk, A.M.3
Ralston, T.S.4
Brockenbrough, J.5
Marks, D.L.6
Oldenburg, A.L.7
Boppart, S.A.8
-
108
-
-
20644456680
-
A portable, low coherence interferometry based instrument for fine needle aspiration biopsy guidance
-
N. V. Iftimia, B. E. Bouma, M. B. Pitman, B. Goldberg, J. Bressner, and G. J. Tearney, "A portable, low coherence interferometry based instrument for fine needle aspiration biopsy guidance," Rev. Sci. Instrum. 76(6), 064301 (2005).
-
(2005)
Rev. Sci. Instrum.
, vol.76
, Issue.6
, pp. 064301
-
-
Iftimia, N.V.1
Bouma, B.E.2
Pitman, M.B.3
Goldberg, B.4
Bressner, J.5
Tearney, G.J.6
-
109
-
-
22244476742
-
Optical coherence tomography: A pilot study of a new imaging technique for noninvasive examination of cervical tissue
-
DOI 10.1016/j.ajog.2004.11.054, PII S0002937804020551
-
A. F. Zuluaga, M. Follen, I. Boiko, A. Malpica, and R. Richards- Kortum, "Optical coherence tomography: A pilot study of a new imaging technique for noninvasive examination of cervical tissue," Am. J. Obstet. Gynecol. 193(1), 83-88 (2005). (Pubitemid 40991830)
-
(2005)
American Journal of Obstetrics and Gynecology
, vol.193
, Issue.1
, pp. 83-88
-
-
Zuluaga, A.F.1
Follen, M.2
Boiko, I.3
Malpica, A.4
Richards-Kortum, R.5
-
110
-
-
33847683406
-
Needle-based refractive index measurement using low-coherence interferometry
-
DOI 10.1364/OL.32.000385
-
A. M. Zysk, S. G. Adie, J. J. Armstrong, M. S. Leigh, A. Paduch, D. D. Sampson, F. T. Nguyen, and S. A. Boppart, "Needle-based refractive index measurement using low-coherence interferometry," Opt. Lett. 32(4), 385-387 (2007). (Pubitemid 46354031)
-
(2007)
Optics Letters
, vol.32
, Issue.4
, pp. 385-387
-
-
Zysk, A.M.1
Adie, S.G.2
Armstrong, J.J.3
Leigh, M.S.4
Paduch, A.5
Sampson, D.D.6
Nguyen, F.T.7
Boppart, S.A.8
-
111
-
-
34247242745
-
Needle-based reflection refractometry of scattering samples using coherence-gated detection
-
DOI 10.1364/OE.15.004787
-
A. M. Zysk, D. L. Marks, D. Y. Liu, and S. A. Boppart, "Needlebased reflection refractometry of scattering samples using coherence-gated detection," Opt. Express 15(8), 4787-4794 (2007). (Pubitemid 46609023)
-
(2007)
Optics Express
, vol.15
, Issue.8
, pp. 4787-4794
-
-
Zysk, A.M.1
Marks, D.L.2
Liu, D.Y.3
Boppart, S.A.4
-
112
-
-
5344278287
-
Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography
-
P. R. Herz, Y. Chen, A. D. Aguirre, K. Schneider, P. Hsiung, J. G. Fujimoto, K. Madden, J. Schmitt, J. Goodnow, and C. Petersen, "Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography," Opt. Lett. 29(19), 2261-2263 (2004).
-
(2004)
Opt. Lett.
, vol.29
, Issue.19
, pp. 2261-2263
-
-
Herz, P.R.1
Chen, Y.2
Aguirre, A.D.3
Schneider, K.4
Hsiung, P.5
Fujimoto, J.G.6
Madden, K.7
Schmitt, J.8
Goodnow, J.9
Petersen, C.10
-
113
-
-
2942568031
-
In vivo endoscopic optical coherence tomography by use of a rotational microelectromechanical system probe
-
P. H. Tran, D. S. Mukai, M. Brenner, and Z. Chen, "In vivo endoscopic optical coherence tomography by use of a rotational microelectromechanical system probe," Opt. Lett. 29(11), 1236-1238 (2004).
-
(2004)
Opt. Lett.
, vol.29
, Issue.11
, pp. 1236-1238
-
-
Tran, P.H.1
Mukai, D.S.2
Brenner, M.3
Chen, Z.4
-
114
-
-
0242440729
-
Endoscopic optical coherence tomography with a modified microelectromechanical systems mirror for detection of bladder cancers
-
T. Xie, H. Xie, G. K. Fedder, and Y. Pan, "Endoscopic optical coherence tomography with a modified microelectromechanical systems mirror for detection of bladder cancers," Appl. Opt. 42(31), 6422-6426 (2003).
-
(2003)
Appl. Opt.
, vol.42
, Issue.31
, pp. 6422-6426
-
-
Xie, T.1
Xie, H.2
Fedder, G.K.3
Pan, Y.4
-
115
-
-
9344241856
-
3-D optical coherence tomography of the laryngeal mucosa
-
DOI 10.1111/j.1365-2273.2004.00902.x
-
A. G. Bibas, A. G. Podoleanu, R. G. Cucu, M. Bonmarin, G. M. Dobre, V. M. M. Ward, E. Odell, A. Boxer, M. J. Gleeson, and D. A. Jackson, "3-D optical coherence tomography of the laryngeal mucosa," Clin. Otolaryngol. 29(6), 713-720 (2004). (Pubitemid 39557008)
-
(2004)
Clinical Otolaryngology and Allied Sciences
, vol.29
, Issue.6
, pp. 713-720
-
-
Bibas, A.G.1
Podoleanu, A.Gh.2
Cucu, R.G.3
Bonmarin, M.4
Dobre, G.M.5
Ward, V.M.M.6
Odell, E.7
Boxer, A.8
Gleeson, M.J.9
Jackson, D.A.10
-
116
-
-
33747178726
-
Optical coherence tomography of laryngeal cancer
-
DOI 10.1097/01.mlg.0000217539.27432.5a, PII 0000553720060700000006
-
W. B. Armstrong, J. M. Ridgway, D. E. Vokes, S. Guo, J. Perez, R. P. Jackson, M. Gu, J. Su, R. L. Crumley, T. Y. Shibuya, U. Mahmood, Z. Chen, and B. J. F. Wong, "Optical coherence tomography of laryngeal cancer," Laryngoscope 116(7), 1107-1113 (2006). (Pubitemid 44317933)
-
(2006)
Laryngoscope
, vol.116
, Issue.7
, pp. 1107-1113
-
-
Armstrong, W.B.1
Ridgway, J.M.2
Vokes, D.E.3
Guo, S.4
Perez, J.5
Jackson, R.P.6
Gu, M.7
Su, J.8
Crumley, R.L.9
Shibuya, T.Y.10
Mahmood, U.11
Chen, Z.12
Wong, B.J.F.13
-
117
-
-
33644687840
-
In vivo optical coherence tomography of the human larynx: Normative and benign pathology in 82 patients
-
DOI 10.1097/01.MLG.0000181465.17744.BE, PII 0000553720051100000002
-
B. J. F. Wong, R. P. Jackson, S. Guo, J. M. Ridgway, U. Mahmood, J. Su, T. Y. Shibuya, R. L. Crumley, M. Gu, W. B. Armstrong, and Z. Chen, "In vivo optical coherence tomography of the human larynx: normative and benign pathology in 82 patients," Laryngoscope 115(11), 1904-1911 (2005). (Pubitemid 44391648)
-
(2005)
Laryngoscope
, vol.115
, Issue.11
, pp. 1904-1911
-
-
Wong, B.J.F.1
Jackson, R.P.2
Guo, S.3
Ridgway, J.M.4
Mahmood, U.5
Su, J.6
Shibuya, T.Y.7
Crumley, R.L.8
Gu, M.9
Armstrong, W.B.10
Chen, Z.11
-
118
-
-
33746791928
-
Charakterisierung von stimmlippen mittels optischer koha renztomographie
-
DOI 10.1007/s00106-005-1373-4
-
K. Lüeren, H. Lubatschowski, K. Ursinus, H. Gasse, R. Koch, and M. Ptok, "Optical coherence tomography in the diagnosis of vocal folds," HNO 54(8), 611-615 (2006). (Pubitemid 44174644)
-
(2006)
HNO
, vol.54
, Issue.8
, pp. 611-615
-
-
Luerssen, K.1
Lubatschowski, H.2
Ursinus, K.3
Gasse, H.4
Koch, R.5
Ptok, M.6
-
119
-
-
33646269739
-
In vivo optical coherence tomography of the nasal mucosa
-
U. Mahmood, J. Ridgway, R. Jackson, S. Guo, J. Su, W. Armstrong, T. Shibuya, R. Crumley, Z. Chen, and B. Wong, "In vivo optical coherence tomography of the nasal mucosa," Am. J. Rhinol. 20(2), 155-159 (2006).
-
(2006)
Am. J. Rhinol.
, vol.20
, Issue.2
, pp. 155-159
-
-
Mahmood, U.1
Ridgway, J.2
Jackson, R.3
Guo, S.4
Su, J.5
Armstrong, W.6
Shibuya, T.7
Crumley, R.8
Chen, Z.9
Wong, B.10
-
120
-
-
33750176737
-
In vivo optical coherence tomography of the human oral cavity and oropharynx
-
J. M. Ridgway, W. B. Armstrong, S. Guo, U. Mahmood, J. Su, R. P. Jackson, T. Shibuya, R. L. Crumley, M. Gu, Z. Chen, and B. J. F. Wong, "In vivo optical coherence tomography of the human oral cavity and oropharynx," Arch. Otolaryngol. Head Neck Surg. 132(10), 1074-1081 (2006). (Pubitemid 44600786)
-
(2006)
Archives of Otolaryngology - Head and Neck Surgery
, vol.132
, Issue.10
, pp. 1074-1081
-
-
Ridgway, J.M.1
Armstrong, W.B.2
Guo, S.3
Mahmood, U.4
Su, J.5
Jackson, R.P.6
Shibuya, T.7
Crumley, R.L.8
Gu, M.9
Chen, Z.10
Wong, B.J.-F.11
-
121
-
-
0033819603
-
Optical coherence tomography in the gastrointestinal tract
-
S. Brand, J. M. Poneros, B. E. Bouma, G. J. Tearney, C. C. Compton, and N. S. Nishioka, "Optical coherence tomography in the gastrointestinal tract," Endoscopy 32(10), 796-803 (2000).
-
(2000)
Endoscopy
, vol.32
, Issue.10
, pp. 796-803
-
-
Brand, S.1
Poneros, J.M.2
Bouma, B.E.3
Tearney, G.J.4
Compton, C.C.5
Nishioka, N.S.6
-
122
-
-
0033809538
-
In vivo endoscopic optical coherence tomography of the human gastrointestinal tract- toward optical biopsy
-
S. Jäckle, N. Gladkova, F. Feldchtein, A. Terentieva, B. Brand, G. Gelikonov, V. Gelikonov, A. Sergeev, A. Fritscher-Ravens, J. Freund, U. Seitz, S. Schröder, and N. Soehendra, "In vivo endoscopic optical coherence tomography of the human gastrointestinal tract- toward optical biopsy," Endoscopy 32(10), 743-749 (2000).
-
(2000)
Endoscopy
, vol.32
, Issue.10
, pp. 743-749
-
-
Jäckle, S.1
Gladkova, N.2
Feldchtein, F.3
Terentieva, A.4
Brand, B.5
Gelikonov, G.6
Gelikonov, V.7
Sergeev, A.8
Fritscher-Ravens, A.9
Freund, J.10
Seitz, U.11
Schröder, S.12
Soehendra, N.13
-
123
-
-
0034010528
-
Feasibility of optical coherence tomography for high-resolution imaging of human gastrointestinal tract malignancies
-
C. Pitris, C. Jesser, S. A. Boppart, D. Stamper, M. E. Brezinski, and J. G. Fujimoto, "Feasibility of optical coherence tomography for high-resolution imaging of human gastrointestinal tract malignancies," J. Gastroenterol. 35(2), 87-92 (2000). (Pubitemid 30128998)
-
(2000)
Journal of Gastroenterology
, vol.35
, Issue.2
, pp. 87-92
-
-
Pitris, C.1
Jesser, C.2
Boppart, S.A.3
Stamper, D.4
Brezinski, M.E.5
Fujimoto, J.G.6
-
124
-
-
0030854352
-
Optical biopsy in human gastrointestinal tissue using optical coherence tomography
-
G. J. Tearney, M. E. Brezinski, J. F. Southern, B. E. Bouma, S. A. Boppart, and J. G. Fujimoto, "Optical biopsy in human gastrointestinal tissue using optical coherence tomography," Am. J. Gastroenterol. 92(10), 1800-1804 (1997). (Pubitemid 27440894)
-
(1997)
American Journal of Gastroenterology
, vol.92
, Issue.10
, pp. 1800-1804
-
-
Tearney, G.J.1
Brezinski, M.E.2
Southern, J.F.3
Bouma, B.E.4
Boppart, S.A.5
Fujimoto, J.G.6
-
125
-
-
20144367266
-
Optical coherence tomography of Barrett's esophagus
-
DOI 10.1055/s-2005-861327
-
A. Chak, M. B. Wallace, and J. M. Poneros, "Optical coherence tomography of Barrett's esophagus," Endoscopy 37(6), 587-590 (2005). (Pubitemid 40775247)
-
(2005)
Endoscopy
, vol.37
, Issue.6
, pp. 587-590
-
-
Chak, A.1
Wallace, M.B.2
Poneros, J.M.3
-
126
-
-
4043093486
-
Barrett's esophagus: Current and future role of endosonography and optical coherence tomography
-
DOI 10.1111/j.1442-2050.2004.00406.x
-
S. A. Faruqi, V. Arantes, and M. S. Bhutani, "Barrett's esophagus: current and future role of endosonography and optical coherence tomography," Dis. Esophagus 17(2), 118-123 (2004). (Pubitemid 39076931)
-
(2004)
Diseases of the Esophagus
, vol.17
, Issue.2
, pp. 118-123
-
-
Faruqi, S.A.1
Arantes, V.2
Bhutani, M.S.3
-
127
-
-
27844517375
-
Accuracy of endoscopic optical coherence tomography in the detection of dysplasia in Barrett's esophagus: A prospective, double-blinded study
-
DOI 10.1016/j.gie.2005.07.048, PII S0016510705026611
-
G. Isenberg, M. V. Sivak, A. Chak, R. C. K. Wong, J. E. Willis, B. Wolf, D. Y. Rowland, A. Das, and A. Rollins, "Accuracy of endoscopic optical coherence tomography in the detection of dysplasia in Barrett's esophagus: a prospective, double-blinded study," Gastrointest. Endosc. 62(6), 825-831 (2005). (Pubitemid 41654413)
-
(2005)
Gastrointestinal Endoscopy
, vol.62
, Issue.6
, pp. 825-831
-
-
Isenberg, G.1
Sivak Jr., M.V.2
Chak, A.3
Wong, R.C.K.4
Willis, J.E.5
Wolf, B.6
Rowland, D.Y.7
Das, A.8
Rollins, A.9
-
128
-
-
0033819094
-
In vivo endoscopic optical coherence tomography of esophagitis, Barrett's esophagus, and adenocarcinoma of the esophagus
-
S. Jäckle, N. Gladkova, F. Feldchtein, A. Terentieva, B. Brand, G. Gelikonov, V. Gelikonov, A. Sergeev, A. Fritscher-Ravens, J. Freund, U. Seitz, S. Schröder, and N. Soehendra, "In vivo endoscopic optical coherence tomography of esophagitis, Barrett's esophagus, and adenocarcinoma of the esophagus," Endoscopy 32(10), 750-755 (2000).
-
(2000)
Endoscopy
, vol.32
, Issue.10
, pp. 750-755
-
-
Jäckle, S.1
Gladkova, N.2
Feldchtein, F.3
Terentieva, A.4
Brand, B.5
Gelikonov, G.6
Gelikonov, V.7
Sergeev, A.8
Fritscher-Ravens, A.9
Freund, J.10
Seitz, U.11
Schröder, S.12
Soehendra, N.13
-
129
-
-
0033674574
-
Optical coherence tomography: Advanced technology for the endoscopic imaging of Barrett's esophagus
-
X. D. Li, S. A. Boppart, J. Van Dam, H. Mashimo, M. Mutinga, W. Drexler, M. Klein, C. Pitris, M. L. Krinsky, M. E. Brezinski, and J. G. Fujimoto, "Optical coherence tomography: advanced technology for the endoscopic imaging of Barrett's esophagus," Endoscopy 32(12), 921-930 (2000).
-
(2000)
Endoscopy
, vol.32
, Issue.12
, pp. 921-930
-
-
Li, X.D.1
Boppart, S.A.2
Van Dam, J.3
Mashimo, H.4
Mutinga, M.5
Drexler, W.6
Klein, M.7
Pitris, C.8
Krinsky, M.L.9
Brezinski, M.E.10
Fujimoto, J.G.11
-
130
-
-
0038518274
-
Diagnosis of Barrett's esophagus using optical coherence tomography
-
DOI 10.1016/S1052-5157(03)00012-6
-
J. M. Poneros and N. S. Nishioka, "Diagnosis of Barrett's esophagus using optical coherence tomography," Gastrointest Endosc Clin. N. Am. 13(2), 309-323 (2003). (Pubitemid 36605247)
-
(2003)
Gastrointestinal Endoscopy Clinics of North America
, vol.13
, Issue.2
, pp. 309-323
-
-
Poneros, J.M.1
Nishioka, N.S.2
-
131
-
-
27844557358
-
Optical coherence tomography and the detection of dysplasia in Barrett's esophagus
-
DOI 10.1016/j.gie.2005.07.027, PII S0016510705024508
-
J. Poneros, "Optical coherence tomography and the detection of dysplasia in Barrett's esophagus," Gastrointest. Endosc. 62(6), 832-833 (2005). (Pubitemid 41654414)
-
(2005)
Gastrointestinal Endoscopy
, vol.62
, Issue.6
, pp. 832-833
-
-
Poneros, J.1
-
132
-
-
33751323220
-
Computer-aided diagnosis of dysplasia in Barrett's esophagus using endoscopic optical coherence tomography
-
X. Qi, M. V. Sivak, G. Isenberg, J. E. Willis, and A. M. Rollins, "Computer-aided diagnosis of dysplasia in Barrett's esophagus using endoscopic optical coherence tomography," J. Biomed. Opt. 11(4), 044010 (2006).
-
(2006)
J. Biomed. Opt.
, vol.11
, Issue.4
, pp. 044010
-
-
Qi, X.1
Sivak, M.V.2
Isenberg, G.3
Willis, J.E.4
Rollins, A.M.5
-
133
-
-
33645453697
-
Prospective grading of neoplastic change in rat esophagus epithelium using angle-resolved low-coherence interferometry
-
A. Wax, J. W. Pyhtila, R. N. Graf, R. Nines, C. W. Boone, R. R. Dasari, M. S. Feld, V. E. Steele, and G. D. Stoner, "Prospective grading of neoplastic change in rat esophagus epithelium using angle-resolved low-coherence interferometry," J. Biomed. Opt. 10(5), 051604 (2005).
-
(2005)
J. Biomed. Opt.
, vol.10
, Issue.5
, pp. 051604
-
-
Wax, A.1
Pyhtila, J.W.2
Graf, R.N.3
Nines, R.4
Boone, C.W.5
Dasari, R.R.6
Feld, M.S.7
Steele, V.E.8
Stoner, G.D.9
-
134
-
-
2942538290
-
Diagnostic efficacy of optical coherence tomography in the management of preinvasive and invasive cancer of uterine cervix and vulva
-
DOI 10.1111/j.1048-891x.2004.14307.x
-
P. F. Escobar, J. L. Belinson, A. White, N. M. Shakhova, F. I. Feldchtein, M. V. Kareta, and N. D. Gladkova, "Diagnostic efficacy of optical coherence tomography in the management of preinvasive and invasive cancer of uterine cervix and vulva," Intl. J. Gynecolog. Cancer 14(3), 470-474 (2004). (Pubitemid 38747427)
-
(2004)
International Journal of Gynecological Cancer
, vol.14
, Issue.3
, pp. 470-474
-
-
Escobar, P.F.1
Belinson, J.L.2
White, A.3
Shakhova, N.M.4
Feldchtein, F.I.5
Kareta, M.V.6
Gladkova, N.D.7
-
135
-
-
0037208318
-
Light scattering from cervical cells throughout neoplastic progression: Influence of nuclear morphology, DNA content, and chromatin texture
-
R. Drezek, M. Guillaud, T. Collier, I. Boiko, A. Malpica, C. Macaulay, M. Follen, and R. Richards-Kortum, "Light scattering from cervical cells throughout neoplastic progression: influence of nuclear morphology, DNA content, and chromatin texture," J. Biomed. Opt. 8(1), 7-16 (2003).
-
(2003)
J. Biomed. Opt.
, vol.8
, Issue.1
, pp. 7-16
-
-
Drezek, R.1
Guillaud, M.2
Collier, T.3
Boiko, I.4
Malpica, A.5
Macaulay, C.6
Follen, M.7
Richards-Kortum, R.8
-
136
-
-
33645214926
-
Novel algorithm of processing optical coherence tomography images for differentiation of biological tissue pathologies
-
I. V. Turchin, E. A. Sergeeva, L. S. Dolin, V. A. Kamensky, N. M. Shakhova, and R. Richards-Kortum, "Novel algorithm of processing optical coherence tomography images for differentiation of biological tissue pathologies," J. Biomed. Opt. 10(6), 064024 (2005).
-
(2005)
J. Biomed. Opt.
, vol.10
, Issue.6
, pp. 064024
-
-
Turchin, I.V.1
Sergeeva, E.A.2
Dolin, L.S.3
Kamensky, V.A.4
Shakhova, N.M.5
Richards-Kortum, R.6
-
137
-
-
0033983388
-
In vivo optical coherence tomography imaging of human skin: Norm and pathology
-
DOI 10.1034/j.1600-0846.2000.006001006.x
-
N. D. Gladkova, G. A. Petrova, N. K. Nikulin, S. G. Radenska- Lopovok, L. B. Snopova, Y. P. Chumakov, V. A. Nasonova, V. M. Gelikonov, G. V. Gelikonov, R. V. Kuranov, A. M. Sergeev, and F. I. Feldchtein,"In vivo optical coherence tomography imaging of human skin: norm and pathology," Skin Res. Technol. 6(1), 6-16 (2000). (Pubitemid 30077135)
-
(2000)
Skin Research and Technology
, vol.6
, Issue.1
, pp. 6-16
-
-
Gladkova, N.D.1
Petrova, G.A.2
Nikulin, N.K.3
Radenska-Lopovok, S.G.4
Snopova, L.B.5
Chumakov, Yu.P.6
Nasonova, V.A.7
Gelikonov, V.M.8
Gelikonov, G.V.9
Kuranov, R.V.10
Sergeev, A.M.11
Feldchtein, F.I.12
-
138
-
-
0033398651
-
High resolution imaging of transitional cell carcinoma with optical coherence tomography: Feasibility for the evaluation of bladder pathology
-
DEC.
-
C. A. Jesser, S. A. Boppart, C. Pitris, D. L. Stamper, G. P. Nielsen, M. E. Brezinski, and J. G. Fujimoto, "High resolution imaging of transitional cell carcinoma with optical coherence tomography: feasibility for the evaluation of bladder pathology," Br. J. Radiol. 72(864), 1170-1176 (1999). (Pubitemid 30028930)
-
(1999)
British Journal of Radiology
, vol.72
, pp. 1170-1176
-
-
Jesser, C.A.1
Boppart, S.A.2
Pitris, C.3
Stamper, D.L.4
Nielsen, G.P.5
Brezinski, M.E.6
Fujimoto, J.G.7
-
139
-
-
22244436962
-
Evaluation of superficial bladder transitional-cell carcinoma by optical coherence tomography
-
DOI 10.1089/end.2005.19.570
-
M. J. Manyak, N. D. Gladkova, J. H. Makari, A. M. Schwartz, E. V. Zagaynova, L. Zolfaghari, J. M. Zara, R. Iksanov, and F. I. Feldchtein, "Evaluation of superficial bladder transitional-cell carcinoma by optical coherence tomography," J. Endourol 19(5), 570-574 (2005). (Pubitemid 40995553)
-
(2005)
Journal of Endourology
, vol.19
, Issue.5
, pp. 570-574
-
-
Manyak, M.J.1
Gladkova, N.D.2
Makari, J.H.3
Schwartz, A.M.4
Zagaynova, E.V.5
Zolfaghari, L.6
Zara, J.M.7
Iksanov, R.8
Feldchtein, F.I.9
-
140
-
-
0033035135
-
Optical coherence tomography in dermatology
-
DOI 10.1111/j.1600-0846.1999.tb00120.x
-
A. Pagnoni, A. Knuettel, P. Welker, M. Rist, T. Stoudemayer, L. Kolbe, I. Sadiq, and A. M. Kligman, "Optical coherence tomography in dermatology," Skin Res. Technol. 5(2), 83-87 (1999). (Pubitemid 29299103)
-
(1999)
Skin Research and Technology
, vol.5
, Issue.2
, pp. 83-87
-
-
Pagnoni, A.1
Knuettel, A.2
Welker, P.3
Rist, M.4
Stoudemayer, T.5
Kolbe, L.6
Sadiq, I.7
Kligman, A.M.8
-
141
-
-
0346392438
-
Enhancing early bladder cancer detection with fluorescence-guided endoscopic optical coherence tomography
-
Y. T. Pan, T. Q. Xie, C. W. Du, S. Bastacky, S. Meyers, and M. L. Zeidel, "Enhancing early bladder cancer detection with fluorescence-guided endoscopic optical coherence tomography," Opt. Lett. 28(24), 2485-2487 (2003).
-
(2003)
Opt. Lett.
, vol.28
, Issue.24
, pp. 2485-2487
-
-
Pan, Y.T.1
Xie, T.Q.2
Du, C.W.3
Bastacky, S.4
Meyers, S.5
Zeidel, M.L.6
-
142
-
-
4143143251
-
Advances in optical coherence tomography imaging for dermatology
-
DOI 10.1111/j.0022-202X.2004.23404.x
-
M. C. Pierce, J. Strasswimmer, B. H. Park, B. Cense, and J. F. de Boer, "Advances in optical coherence tomography imaging for dermatology," J. Invest. Dermatol. 123(3), 458-463 (2004). (Pubitemid 39095614)
-
(2004)
Journal of Investigative Dermatology
, vol.123
, Issue.3
, pp. 458-463
-
-
Pierce, M.C.1
Strasswimmer, J.2
Park, B.H.3
Cense, B.4
De Boer, J.F.5
-
143
-
-
0029126718
-
Subsurface imaging of living skin with optical coherence microscopy
-
J. M. Schmitt, M. J. Yadlowsky, and R. F. Bonner, "Subsurface imaging of living skin with optical coherence microscopy," Dermatology (Basel, Switz.) 191(2), 93-98 (1995).
-
(1995)
Dermatology (Basel, Switz.)
, vol.191
, Issue.2
, pp. 93-98
-
-
Schmitt, J.M.1
Yadlowsky, M.J.2
Bonner, R.F.3
-
144
-
-
27744587902
-
Fluorescence guided optical coherence tomography for the diagnosis of early bladder cancer in a rat model
-
DOI 10.1097/01.ju.0000180413.98752.a1
-
Z. G. Wang, D. B. Durand, M. Schoenberg, and Y. T. Pan, "Fluorescence guided optical coherence tomography for the diagnosis of early bladder cancer in a rat model," J. Urol. (Baltimore) 174(6), 2376-2381 (2005). (Pubitemid 41611832)
-
(2005)
Journal of Urology
, vol.174
, Issue.6
, pp. 2376-2381
-
-
Wang, Z.G.1
Durand, D.B.2
Schoenberg, M.3
Pan, Y.T.4
-
145
-
-
0036165630
-
In vivo optical coherence tomography feasibility for bladder disease
-
E. V. Zagaynova, O. S. Streltsova, N. D. Gladkova, L. B. Snopova, G. V. Gelikonov, F. I. Feldchtein, and A. N. Morozov, "In vivo optical coherence tomography feasibility for bladder disease," J. Urol. (Baltimore) 167(3), 1492-1496 (2002). (Pubitemid 34132138)
-
(2002)
Journal of Urology
, vol.167
, Issue.3
, pp. 1492-1496
-
-
Zagaynova, E.V.1
Streltsova, O.S.2
Gladkova, N.D.3
Snopova, L.B.4
Gelikonov, G.V.5
Feldchtein, F.I.6
Morozov, A.N.7
-
146
-
-
0031456997
-
Optical coherence tomography of the human skin
-
DOI 10.1016/S0190-9622(97)70072-0
-
J. Welzel, E. Lankenau, R. Birngruber, and R. Engelhardt, "Optical coherence tomography of the human skin," J. Am. Acad. Dermatol. 37(6), 958-963 (1997). (Pubitemid 28016626)
-
(1997)
Journal of the American Academy of Dermatology
, vol.37
, Issue.6
, pp. 958-963
-
-
Welzel, J.1
Lankenau, E.2
Birngruber, R.3
Engelhardt, R.4
-
147
-
-
0035188381
-
Optical coherence tomography in dermatology: A review
-
DOI 10.1034/j.1600-0846.2001.007001001.x
-
J. Welzel, "Optical coherence tomography in dermatology: a review," Skin Res. Technol. 7(1), 1-9 (2001). (Pubitemid 32060993)
-
(2001)
Skin Research and Technology
, vol.7
, Issue.1
, pp. 1-9
-
-
Welzel, J.1
-
148
-
-
1542507092
-
Changes in function and morphology of normal human skin: Evaluation using optical coherence tomography
-
DOI 10.1111/j.1365-2133.2004.05810.x
-
J. Welzel, C. Reinhardt, E. Lankenau, C. Winter, and H. H. Wolff, "Changes in function and morphology of normal human skin: evaluation using optical coherence tomography," Br. J. Dermatol. 150(2), 220-225 (2004). (Pubitemid 38352458)
-
(2004)
British Journal of Dermatology
, vol.150
, Issue.2
, pp. 220-225
-
-
Welzel, J.1
Reinhardt, C.2
Lankenau, E.3
Winter, C.4
Wolff, H.H.5
-
149
-
-
0034986880
-
Correlation of collagen organization with polarization sensitive imaging of in vitro cartilage: Implications for osteoarthritis
-
W. Drexler, D. Stamper, C. Jesser, X. Li, C. Pitris, K. Saunders, S. Martin, M. B. Lodge, J. G. Fujimoto, and M. E. Brezinski, "Correlation of collagen organization with polarization sensitive imaging of in vitro cartilage: implications for osteoarthritis," J. Rheumatol. 28(6), 1311-1318 (2001). (Pubitemid 32510503)
-
(2001)
Journal of Rheumatology
, vol.28
, Issue.6
, pp. 1311-1318
-
-
Drexler, W.1
Stamper, D.2
Jesser, C.3
Li, X.4
Pitris, C.5
Saunders, K.6
Martin, S.7
Lodge, M.B.8
Fujimoto, J.G.9
Brezinski, M.E.10
-
150
-
-
33344455990
-
High-resolution optical coherence tomographic imaging of osteoarthritic cartilage during open knee surgery
-
X. Li, S. Martin, C. Pitris, R. Ghanta, D. L. Stamper, M. Harman, J. G. Fujimoto, and M. E. Brezinski, "High-resolution optical coherence tomographic imaging of osteoarthritic cartilage during open knee surgery," Arthritis Res. Ther. 7(2), R318-R323 (2005).
-
(2005)
Arthritis Res. Ther.
, vol.7
, Issue.2
-
-
Li, X.1
Martin, S.2
Pitris, C.3
Ghanta, R.4
Stamper, D.L.5
Harman, M.6
Fujimoto, J.G.7
Brezinski, M.E.8
-
151
-
-
33750742807
-
Determination of characteristics of degenerative joint disease using optical coherence tomography and polarization sensitive optical coherence tomography
-
DOI 10.1002/lsm.20394
-
T. Xie, S. Guo, J. Zhang, Z. Chen, and G. M. Peavy, "Determination of characteristics of degenerative joint disease using optical coherence tomography and polarization sensitive optical coherence tomography," Lasers Surg. Med. 38(9), 852-865 (2006). (Pubitemid 44706591)
-
(2006)
Lasers in Surgery and Medicine
, vol.38
, Issue.9
, pp. 852-865
-
-
Xie, T.1
Guo, S.2
Zhang, J.3
Chen, Z.4
Peavy, G.M.5
-
152
-
-
2942735122
-
In vivo size and shape measurement of the human upper airway using endoscopic long-range optical coherence tomography
-
J. J. Armstrong, M. S. Leigh, I. D. Walton, A. V. Zvyagin, S. A. Alexandrov, S. Schwer, D. D. Sampson, D. R. Hillman, and P. R. Eastwood, "In vivo size and shape measurement of the human upper airway using endoscopic long-range optical coherence tomography," Opt. Express 11(15), 1817-1826 (2003).
-
(2003)
Opt. Express
, vol.11
, Issue.15
, pp. 1817-1826
-
-
Armstrong, J.J.1
Leigh, M.S.2
Walton, I.D.3
Zvyagin, A.V.4
Alexandrov, S.A.5
Schwer, S.6
Sampson, D.D.7
Hillman, D.R.8
Eastwood, P.R.9
-
153
-
-
31944432073
-
Quantitative upper airway imaging with anatomic optical coherence tomography
-
DOI 10.1164/rccm.200507-1148OC
-
J. J. Armstrong, M. S. Leigh, D. D. Sampson, J. H. Walsh, D. R. Hillman, and P. R. Eastwood, "Quantitative upper airway imaging with anatomic optical coherence tomography," Am. J. Respir. Crit. Care Med. 173(2), 226-233 (2006). (Pubitemid 43187896)
-
(2006)
American Journal of Respiratory and Critical Care Medicine
, vol.173
, Issue.2
, pp. 226-233
-
-
Armstrong, J.J.1
Leigh, M.S.2
Sampson, D.D.3
Walsh, J.H.4
Hillman, D.R.5
Eastwood, P.R.6
-
154
-
-
31644444382
-
Imaging carious human dental tissue with optical coherence tomography
-
A. Z. Freitas, D. M. Zezell, N. D. Vieira, A. C. Ribeiro, and A. S. L. Gomes, "Imaging carious human dental tissue with optical coherence tomography," J. Appl. Phys. 99(2), 024906 (2006).
-
(2006)
J. Appl. Phys.
, vol.99
, Issue.2
, pp. 024906
-
-
Freitas, A.Z.1
Zezell, D.M.2
Vieira, N.D.3
Ribeiro, A.C.4
Gomes, A.S.L.5
-
155
-
-
0034169962
-
Optical coherence tomography: A new imaging technology for dentistry
-
L. L. Otis, M. J. Everett, U. S. Sathyam, and B. W. Colston, "Optical coherence tomography: A new imaging technology for dentistry," J. Am. Dent. Assoc. 131(4), 511-514 (2000).
-
(2000)
J. Am. Dent. Assoc.
, vol.131
, Issue.4
, pp. 511-514
-
-
Otis, L.L.1
Everett, M.J.2
Sathyam, U.S.3
Colston, B.W.4
-
157
-
-
84894131720
-
-
Cureline, Inc., see .
-
Cureline, Inc., see http://www.cureline.com (2007).
-
(2007)
-
-
-
158
-
-
84894152546
-
-
National Disease Research Exchange, see
-
National Disease Research Exchange, see http://www.ndriresource.org (2007).
-
(2007)
-
-
-
160
-
-
0025095189
-
Practice policies: Where do they come from?
-
D. M. Eddy, "Practice policies: where do they come from?" JAMA, J. Am. Med. Assoc. 263(9), 1265 (1990).
-
(1990)
JAMA, J. Am. Med. Assoc.
, vol.263
, Issue.9
, pp. 1265
-
-
Eddy, D.M.1
-
161
-
-
0034911710
-
Overview of evidence-based medicine: Challenges for evidence-based laboratory medicine
-
M. J. McQueen, "Overview of evidence-based medicine: Challenges for evidence-based laboratory medicine," Clin. Chem. 47(8), 1536-1546 (2001). (Pubitemid 32678849)
-
(2001)
Clinical Chemistry
, vol.47
, Issue.8
, pp. 1536-1546
-
-
McQueen, M.J.1
-
162
-
-
0033870278
-
Evidence-based laboratory medicine: Supporting decision- making
-
C. P. Price, "Evidence-based laboratory medicine: supporting decision-making," Clin. Chem. 46(8), 1041-1050 (2000). (Pubitemid 30643303)
-
(2000)
Clinical Chemistry
, vol.46
, Issue.8
, pp. 1041-1050
-
-
Price, C.P.1
-
163
-
-
0037006639
-
Evidence base of clinical diagnosis: The architecture of diagnostic research
-
D. L. Sackett and R. B. Haynes, "The architecture of diagnostic research. (Evidence base of clinical diagnosis(," Br. Med. J. 324(7336), 539-541 (2002). (Pubitemid 34185274)
-
(2002)
British Medical Journal
, vol.324
, Issue.7336
, pp. 539-541
-
-
Sackett, D.L.1
Haynes, R.B.2
-
164
-
-
84894155795
-
-
"Animal welfare act of 1966 as amended 1970, 1976, 1984, 1985, 1990, 1991 and 1995" (1966).
-
(1966)
Animal Welfare Act of 1966 As Amended 1970, 1976, 1984, 1985, 1990, 1991 and 1995
-
-
-
169
-
-
84894164010
-
Panel discussion: Translating optical technologies from benchtop to clinical standard
-
Bethesda, MD
-
B. J. Tromberg, J. C. Pearson, J. M. Crawford, D. A. Benaron, A. Hayward, R. Waynant, and P. Barker, "Panel discussion: Translating optical technologies from benchtop to clinical standard," in Optical Imaging 2006: Fifth Inter-Institute Workshop on Optical Diagnostic Imaging from Bench to Bedside at the National Institutes of Health, Bethesda, MD (2006).
-
(2006)
Optical Imaging 2006: Fifth Inter-Institute Workshop on Optical Diagnostic Imaging from Bench to Bedside at the National Institutes of Health
-
-
Tromberg, B.J.1
Pearson, J.C.2
Crawford, J.M.3
Benaron, D.A.4
Hayward, A.5
Waynant, R.6
Barker, P.7
-
170
-
-
0035063889
-
Molecular imaging
-
R. Weissleder and U. Mahmood, "Molecular imaging," Radiology 219(2), 316-333 (2001). (Pubitemid 32336342)
-
(2001)
Radiology
, vol.219
, Issue.2
, pp. 316-333
-
-
Weissleder, R.1
Mahmood, U.2
-
171
-
-
32944473117
-
Optical probes and techniques for molecular contrast enhancement in coherence imaging
-
S. A. Boppart, A. L. Oldenburg, C. Xu, and D. L. Marks, "Optical probes and techniques for molecular contrast enhancement in coherence imaging," J. Biomed. Opt. 10(4), 041208 (2005).
-
(2005)
J. Biomed. Opt.
, vol.10
, Issue.4
, pp. 041208
-
-
Boppart, S.A.1
Oldenburg, A.L.2
Xu, C.3
Marks, D.L.4
-
173
-
-
0242266976
-
3-Integrin-Targeted Nanoparticles
-
DOI 10.1161/01.CIR.0000093185.16083.95
-
P. M. Winter, A. M. Morawski, S. D. Caruthers, R. W. Fuhrhop, H. Zhang, T. A. Williams, J. S. Allen, E. K. Lacy, J. D. Robertson, G. M. Lanza, and S. A. Wickline, "Molecular imaging of angiogenesis in early-stage atherosclerosis with (v(3-integrin-targeted nanoparticles," Circulation 108(18), 2270-2274 (2003). (Pubitemid 37363046)
-
(2003)
Circulation
, vol.108
, Issue.18
, pp. 2270-2274
-
-
Winter, P.M.1
Morawski, A.M.2
Caruthers, S.D.3
Fuhrhop, R.W.4
Zhang, H.5
Williams, T.A.6
Allen, J.S.7
Lacy, E.K.8
Robertson, J.D.9
Lanza, G.M.10
Wickline, S.A.11
-
174
-
-
33645380798
-
Tumor targeting by surface-modified protein microspheres
-
F. J. J. Toublan, S. Boppart, and K. S. Suslick, "Tumor targeting by surface-modified protein microspheres," J. Am. Chem. Soc. 128(11), 3472-3473 (2006).
-
(2006)
J. Am. Chem. Soc.
, vol.128
, Issue.11
, pp. 3472-3473
-
-
Toublan, F.J.J.1
Boppart, S.2
Suslick, K.S.3
-
175
-
-
0032557305
-
Nanoengineering of optical resonances
-
PII S0009261498002772
-
S. J. Oldenburg, R. D. Averitt, S. L. Westcott, and N. J. Halas, "Nanoengineering of optical resonances," Chem. Phys. Lett. 288(2), 243-247 (1998). (Pubitemid 128185622)
-
(1998)
Chemical Physics Letters
, vol.288
, Issue.2-4
, pp. 243-247
-
-
Oldenburg, S.J.1
Averitt, R.D.2
Westcott, S.L.3
Halas, N.J.4
-
176
-
-
33751348329
-
Quantitative evaluation of optical coherence tomography signal enhancement with gold nanoshells
-
A. Agrawal, S. Huang, A. W. H. Lin, M. H. Lee, J. K. Barton, R. A. Drezek, and T. J. Pfefer, "Quantitative evaluation of optical coherence tomography signal enhancement with gold nanoshells," J. Biomed. Opt. 11(4), 041121 (2006).
-
(2006)
J. Biomed. Opt.
, vol.11
, Issue.4
, pp. 041121
-
-
Agrawal, A.1
Huang, S.2
Lin, A.W.H.3
Lee, M.H.4
Barton, J.K.5
Drezek, R.A.6
Pfefer, T.J.7
-
177
-
-
0034662609
-
Hyperthermia enables tumor-specific nanoparticle delivery: Effect of particle size
-
G. Kong, R. D. Braun, and M. W. Dewhirst, "Hyperthermia enables tumor-specific nanoparticle delivery: Effect of particle size," Cancer Res. 60(16), 4440-4445 (2000). (Pubitemid 32103623)
-
(2000)
Cancer Research
, vol.60
, Issue.16
, pp. 4440-4445
-
-
Kong, G.1
Braun, R.D.2
Dewhirst, M.W.3
-
178
-
-
0345686712
-
Nanoshell-mediated near-infrared thermal therapy of tumors under magnetic resonance guidance
-
DOI 10.1073/pnas.2232479100
-
L. R. Hirsch, R. J. Stafford, J. A. Bankson, S. R. Sershen, B. Rivera, R. E. Price, J. D. Hazle, N. J. Halas, and J. L. West, "Nanoshellmediated near-infrared thermal therapy of tumors under magnetic resonance guidance," Proc. Natl. Acad. Sci. U.S.A. 100(23), 13549-13554 (2003). (Pubitemid 37444779)
-
(2003)
Proceedings of the National Academy of Sciences of the United States of America
, vol.100
, Issue.23
, pp. 13549-13554
-
-
Hirsch, L.R.1
Stafford, R.J.2
Bankson, J.A.3
Sershen, S.R.4
Rivera, B.5
Price, R.E.6
Hazle, J.D.7
Halas, N.J.8
West, J.L.9
-
179
-
-
20144388113
-
Gold nanocages: Bioconjugation and their potential use as optical imaging contrast agents
-
DOI 10.1021/nl047950t
-
J. Chen, F. Saeki, B. J. Wiley, H. Cang, M. J. Cobb, Z. Y. Li, L. Au, H. Zhang, M. B. Kimmey, X. Li, and Y. Xia, "Gold nanocages: Bioconjugation and their potential use as optical imaging contrast agents," Nano Lett. 5(3), 473-477 (2005). (Pubitemid 40449718)
-
(2005)
Nano Letters
, vol.5
, Issue.3
, pp. 473-477
-
-
Chen, J.1
Saeki, F.2
Wiley, B.J.3
Cang, H.4
Cobb, M.J.5
Li, Z.-Y.6
Au, L.7
Zhang, H.8
Kimmey, M.B.9
Li, X.10
Xia, Y.11
-
180
-
-
33746379543
-
Plasmon-resonant gold nanorods as low backscattering albedo contrast agents for optical coherence tomography
-
DOI 10.1364/OE.14.006724
-
A. L. Oldenburg, M. N. Hansen, D. A. Zweifel, A. Wei, and S. A. Boppart, "Plasmon-resonant gold nanorods as low backscattering albedo contrast agents for optical coherence tomography," Opt. Express 14(15), 6724-6738 (2006). (Pubitemid 44118111)
-
(2006)
Optics Express
, vol.14
, Issue.15
, pp. 6724-6738
-
-
Oldenburg, A.L.1
Hansen, M.N.2
Zweifel, D.A.3
Wei, A.4
Boppart, S.A.5
-
181
-
-
33244457595
-
Cancer cell imaging and photothermal therapy in the near-infrared region by using gold nanorods
-
DOI 10.1021/ja057254a
-
X. Huang, I. H. El-Sayed, W. Qian, and M. A. El-Sayed, "Cancer cell imaging and photothermal therapy in the near-infrared region by using gold nanorods," J. Am. Chem. Soc. 128(6), 2115-2120 (2006). (Pubitemid 43277351)
-
(2006)
Journal of the American Chemical Society
, vol.128
, Issue.6
, pp. 2115-2120
-
-
Huang, X.1
El-Sayed, I.H.2
Qian, W.3
El-Sayed, M.A.4
-
182
-
-
0347807762
-
Spectroscopic optical coherence tomography
-
U. Morgner, W. Drexler, F. X. Kärtner, X. D. Li, C. Pitris, E. P. Ippen, and J. G. Fujimoto, "Spectroscopic optical coherence tomography," Opt. Lett. 25(2), 111-113 (2000).
-
(2000)
Opt. Lett.
, vol.25
, Issue.2
, pp. 111-113
-
-
Morgner, U.1
Drexler, W.2
Kärtner, F.X.3
Li, X.D.4
Pitris, C.5
Ippen, E.P.6
Fujimoto, J.G.7
-
183
-
-
19944405770
-
Toward assessment of blood oxygen saturation by spectroscopic optical coherence tomography
-
DOI 10.1364/OL.30.001015
-
D. J. Faber, E. G. Mik, M. C. G. Aalders, and T. G. van Leeuwen, "Toward assessment of blood oxygen saturation by spectroscopic optical coherence tomography," Opt. Lett. 30(9), 1015-1017 (2005). (Pubitemid 40749267)
-
(2005)
Optics Letters
, vol.30
, Issue.9
, pp. 1015-1017
-
-
Faber, D.J.1
Mik, E.G.2
Aalders, M.C.G.3
Van Leeuwen, T.G.4
-
184
-
-
10444251836
-
Optical coherence tomography contrast enhancement using spectroscopic analysis with spectral autocorrelation
-
D. C. Adler, T. H. Ko, P. R. Herz, and J. G. Fujimoto, "Optical coherence tomography contrast enhancement using spectroscopic analysis with spectral autocorrelation," Opt. Express 12(22), 5487-5501 (2004).
-
(2004)
Opt. Express
, vol.12
, Issue.22
, pp. 5487-5501
-
-
Adler, D.C.1
Ko, T.H.2
Herz, P.R.3
Fujimoto, J.G.4
-
185
-
-
22744437759
-
Wavelength-dependent scattering in spectroscopic optical coherence tomography
-
DOI 10.1364/OPEX.13.005450
-
C. Xu, P. S. Carney, and S. A. Boppart, "Wavelength-dependent scattering in spectroscopic optical coherence tomography," Opt. Express 13(14), 5450-5462 (2005). (Pubitemid 41029298)
-
(2005)
Optics Express
, vol.13
, Issue.14
, pp. 5450-5462
-
-
Xu, C.1
Carney, P.S.2
Boppart, S.A.3
-
186
-
-
9144234261
-
Separation of absorption and scattering profiles in spectroscopic optical coherence tomography using a least-squares algorithm
-
C. Xu, D. L. Marks, M. N. Do, and S. A. Boppart, "Separation of absorption and scattering profiles in spectroscopic optical coherence tomography using a least-squares algorithm," Opt. Express 12(20), 4790-4803 (2004).
-
(2004)
Opt. Express
, vol.12
, Issue.20
, pp. 4790-4803
-
-
Xu, C.1
Marks, D.L.2
Do, M.N.3
Boppart, S.A.4
-
187
-
-
27844512424
-
Gold nanocages as contrast agents for spectroscopic optical coherence tomography
-
DOI 10.1364/OL.30.003048
-
H. Cang, T. Sun, Z. Y. Li, J. Chen, B. J. Wiley, Y. Xia, and X. Li, "Gold nanocages as contrast agents for spectroscopic optical coherence tomography," Opt. Lett. 30(22), 3048-3050 (2005). (Pubitemid 41655030)
-
(2005)
Optics Letters
, vol.30
, Issue.22
, pp. 3048-3050
-
-
Cang, H.1
Sun, T.2
Li, Z.-Y.3
Chen, J.4
Wiley, B.J.5
Xia, Y.6
Li, X.7
-
188
-
-
22944453348
-
Functional imaging of dye concentration in tissue phantoms by spectroscopic optical coherence tomography
-
T. Støren, A. Røyset, L. O. Svaasand, and T. Lindmo, "Functional imaging of dye concentration in tissue phantoms by spectroscopic optical coherence tomography," J. Biomed. Opt. 10(2), 024037 (2005).
-
(2005)
J. Biomed. Opt.
, vol.10
, Issue.2
, pp. 024037
-
-
Støren, T.1
Røyset, A.2
Svaasand, L.O.3
Lindmo, T.4
-
189
-
-
0038469746
-
Noninvasive detection of clinically occult lymph-node metastases in prostate cancer
-
DOI 10.1056/NEJMoa022749
-
M. G. Harisinghani, J. Barentsz, P. F. Hahn, W. M. Deserno, S. Tabatabaei, C. H. van de Kaa, J. de la Rosette, and R. Weissleder, "Noninvasive detection of clinically occult lymph-node metastases in prostate cancer," N. Engl. J. Med. 348(25), 2491-2499 (2003). (Pubitemid 36706536)
-
(2003)
New England Journal of Medicine
, vol.348
, Issue.25
, pp. 2491-2499
-
-
Harisinghani, M.G.1
Barentsz, J.2
Hahn, P.F.3
Deserno, W.M.4
Tabatabaei, S.5
Van De Kaa, C.H.6
De La Rosette, J.7
Weissleder, R.8
-
190
-
-
24144492996
-
Magnetomotive contrast for in vivo optical coherence tomography
-
DOI 10.1364/OPEX.13.006597
-
A. L. Oldenburg, F. J. J. Toublan, K. S. Suslick, A. Wei, and S. A. Boppart, "Magnetomotive contrast for in vivo optical coherence tomography," Opt. Express 13(17), 6597-6614 (2005). (Pubitemid 41230884)
-
(2005)
Optics Express
, vol.13
, Issue.17
, pp. 6597-6614
-
-
Oldenburg, A.L.1
Toublan, F.J.-J.2
Suslick, K.S.3
Wei, A.4
Boppart, S.A.5
-
191
-
-
33645730491
-
Hemoglobin contrast in magnetomotive optical Doppler tomography
-
J. Kim, J. Oh, T. E. Milner, and J. S. Nelson, "Hemoglobin contrast in magnetomotive optical Doppler tomography," Opt. Lett. 31(6), 778-780 (2006).
-
(2006)
Opt. Lett.
, vol.31
, Issue.6
, pp. 778-780
-
-
Kim, J.1
Oh, J.2
Milner, T.E.3
Nelson, J.S.4
-
192
-
-
0037373410
-
MR molecular imaging of the Her-2/neu receptor in breast cancer cells using targeted iron oxide nanoparticles
-
DOI 10.1002/mrm.10406
-
D. Artemov, N. Mori, B. Okollie, and Z. M. Bhujwalla, "MR molecular imaging of the Her-2/neu receptor in breast cancer cells using targeted iron oxide nanoparticles," Magn. Reson. Med. 49(3), 403-408 (2003). (Pubitemid 36262806)
-
(2003)
Magnetic Resonance in Medicine
, vol.49
, Issue.3
, pp. 403-408
-
-
Artemov, D.1
Mori, N.2
Okollie, B.3
Bhujwalla, Z.M.4
-
193
-
-
10044273054
-
Factors regulating macrophage endocytosis of nanoparticles: Implications for targeted magnetic resonance plaque imaging
-
DOI 10.1016/j.atherosclerosis.2004.08.017, PII S0021915004004265
-
W. J. Rogers and P. Basu, "Factors regulating macrophage endocytosis of nanoparticles: implications for targeted magnetic resonance plaque imaging," Atherosclerosis 178(1), 67-73 (2005). (Pubitemid 39600817)
-
(2005)
Atherosclerosis
, vol.178
, Issue.1
, pp. 67-73
-
-
Rogers, W.J.1
Basu, P.2
-
194
-
-
33748904804
-
Detection of magnetic nanoparticles in tissue using magneto-motive ultrasound
-
DOI 10.1088/0957-4484/17/16/031, PII S0957448406249924, 031
-
J. Oh, M. D. Feldman, J. Kim, C. Condit, S. Emalianov, and T. E. Milner, "Detection of magnetic nanoparticles in tissue using magneto-motive ultrasound," Nanotechnology 17(16), 4183-4190 (2006). (Pubitemid 44424369)
-
(2006)
Nanotechnology
, vol.17
, Issue.16
, pp. 4183-4190
-
-
Oh, J.1
Feldman, M.D.2
Kim, J.3
Condit, C.4
Emelianov, S.5
Milner, T.E.6
-
195
-
-
0141996405
-
Selective hyperthermia using magnetoliposomes to target cervical lymph node metastasis in a rabbit tongue tumor model
-
DOI 10.1111/j.1349-7006.2003.tb01527.x
-
S. Hamaguchi, I. Tohnai, A. Ito, K. Mitsudo, T. Shigetomi, M. Ito, H. Honda, T. Kobayashi, and M. Ueda, "Selective hyperthermia using magnetoliposomes to target cervical lymph node metastasis in a rabbit tongue tumor model," Cancer Sci. 94(9), 834-839 (2003). (Pubitemid 37258784)
-
(2003)
Cancer Science
, vol.94
, Issue.9
, pp. 834-839
-
-
Hamaguchi, S.1
Tohnai, I.2
Ito, A.3
Mitsudo, K.4
Shigetomi, T.5
Ito, M.6
Honda, H.7
Kobayashi, T.8
Ueda, M.9
-
196
-
-
30144435886
-
Theoretical comparison of the sensitivity of molecular contrast optical coherence tomography techniques
-
DOI 10.1364/OPEX.13.008146
-
B. E. Applegate, C. Yang, and J. A. Izatt, "Theoretical comparison of the sensitivity of molecular contrast optical coherence tomography techniques," Opt. Express 13(20), 8146-8163 (2005). (Pubitemid 43051527)
-
(2005)
Optics Express
, vol.13
, Issue.20
, pp. 8146-8163
-
-
Applegate, B.E.1
Yang, C.2
Izatt, J.A.3
-
197
-
-
33749375143
-
Molecular imaging of endogenous and exogenous chromophores using ground state recovery pump-probe optical coherence tomography
-
DOI 10.1364/OE.14.009142
-
B. E. Applegate and J. A. Izatt, "Molecular imaging of endogenous and exogenous chromophores using ground state recovery pumpprobe optical coherence tomography," Opt. Express 14(20), 9142-9155 (2006). (Pubitemid 44507179)
-
(2006)
Optics Express
, vol.14
, Issue.20
, pp. 9142-9155
-
-
Applegate, B.E.1
Izatt, J.A.2
-
198
-
-
0001104529
-
Three-dimensional vibrational imaging by coherent anti-Stokes Raman scattering
-
A. Zumbusch, G. R. Holtom, and X. S. Xie, "Three-dimensional vibrational imaging by coherent anti-Stokes Raman scattering," Phys. Rev. Lett. 82(20), 4142-4145 (1999). (Pubitemid 129689382)
-
(1999)
Physical Review Letters
, vol.82
, Issue.20
, pp. 4142-4145
-
-
Zumbusch, A.1
Holtom, G.R.2
Xie, X.S.3
-
199
-
-
12844260820
-
Interferometric differentiation between resonant coherent anti-Stokes Raman scattering and nonresonant four-wave-mixing processes
-
DOI 10.1063/1.1829162
-
D. L. Marks, C. Vinegoni, J. S. Bredfeldt, and S. A. Boppart, "Interferometric differentiation between resonant coherent anti-Stokes Raman scattering and nonresonant four-wave-mixing processes," Appl. Phys. Lett. 85(23), 5787-5789 (2004). (Pubitemid 40162594)
-
(2004)
Applied Physics Letters
, vol.85
, Issue.23
, pp. 5787-5789
-
-
Marks, D.L.1
Vinegoni, C.2
Bredfeldt, J.S.3
Boppart, S.A.4
-
200
-
-
10944251764
-
(3) for vibrational microscopy
-
DOI 10.1364/OL.29.002923
-
C. L. Evans, E. O. Potma, and X. S. Xie, "Coherent anti-Stokes Raman scattering spectral interferometry: determination of the real and imaginary components of nonlinear susceptibility chi(3) for vibrational microscopy," Opt. Lett. 29(24), 2923-2925 (2004). (Pubitemid 40011269)
-
(2004)
Optics Letters
, vol.29
, Issue.24
, pp. 2923-2925
-
-
Evans, C.L.1
Potma, E.O.2
Xie, X.S.3
-
201
-
-
33644555872
-
Heterodyne coherent anti-Stokes Raman scattering (CARS) imaging
-
E. O. Potma, C. L. Evans, and X. S. Xie, "Heterodyne coherent anti-Stokes Raman scattering (CARS) imaging," Opt. Lett. 31(2), 241-243 (2006).
-
(2006)
Opt. Lett.
, vol.31
, Issue.2
, pp. 241-243
-
-
Potma, E.O.1
Evans, C.L.2
Xie, X.S.3
-
202
-
-
4644260415
-
Ultrahigh resolution optical biopsy with endoscopic optical coherence tomography
-
P. R. Herz, Y. Chen, A. D. Aguirre, J. G. Fujimoto, H. Mashimo, J. Schmitt, A. Koski, J. Goodnow, and C. Petersen, "Ultrahigh resolution optical biopsy with endoscopic optical coherence tomography," Opt. Express 12(15), 3532-3542 (2004).
-
(2004)
Opt. Express
, vol.12
, Issue.15
, pp. 3532-3542
-
-
Herz, P.R.1
Chen, Y.2
Aguirre, A.D.3
Fujimoto, J.G.4
Mashimo, H.5
Schmitt, J.6
Koski, A.7
Goodnow, J.8
Petersen, C.9
-
203
-
-
0001253990
-
Video-rate three-dimensional optical coherence tomography
-
M. Laubscher, M. Ducros, B. Karamata, T. Lasser, and R. Salathé, "Video-rate three-dimensional optical coherence tomography," Opt. Express 10(9), 429-435 (2002).
-
(2002)
Opt. Express
, vol.10
, Issue.9
, pp. 429-435
-
-
Laubscher, M.1
Ducros, M.2
Karamata, B.3
Lasser, T.4
Salathé, R.5
-
204
-
-
2942720818
-
In vivo high-resolution video-rate spectral-domain optical coherence tomography of the human retina and optic nerve
-
N. A. Nassif, B. Cense, B. H. Park, M. C. Pierce, S. H. Yun, B. E. Bouma, G. J. Tearney, T. C. Chen, and J. F. de Boer, "In vivo high-resolution video-rate spectral-domain optical coherence tomography of the human retina and optic nerve," Opt. Express 12(3), 367-376 (2004).
-
(2004)
Opt. Express
, vol.12
, Issue.3
, pp. 367-376
-
-
Nassif, N.A.1
Cense, B.2
Park, B.H.3
Pierce, M.C.4
Yun, S.H.5
Bouma, B.E.6
Tearney, G.J.7
Chen, T.C.8
De Boer, J.F.9
-
205
-
-
1542398242
-
In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography
-
N. Nassif, B. Cense, B. H. Park, S. H. Yun, T. C. Chen, B. E. Bouma, G. J. Tearney, and J. F. de Boer, "In vivo human retinal imaging by ultrahigh-speed spectral domain optical coherence tomography," Opt. Lett. 29(5), 480-482 (2004).
-
(2004)
Opt. Lett.
, vol.29
, Issue.5
, pp. 480-482
-
-
Nassif, N.1
Cense, B.2
Park, B.H.3
Yun, S.H.4
Chen, T.C.5
Bouma, B.E.6
Tearney, G.J.7
De Boer, J.F.8
-
206
-
-
10944229859
-
Real-time, ultrahigh-resolution, optical coherence tomography with an all-fiber, femtosecond fiber laser continuum at 1.5 μm
-
DOI 10.1364/OL.29.002846
-
N. Nishizawa, Y. Chen, P. Hsiung, E. P. Ippen, and J. G. Fujimoto, "Real-time, ultrahigh-resolution, optical coherence tomography with an all-fiber, femtosecond fiber laser continuum at 1.5 (m," Opt. Lett. 29(24), 2846-2848 (2004). (Pubitemid 40011245)
-
(2004)
Optics Letters
, vol.29
, Issue.24
, pp. 2846-2848
-
-
Nishizawa, N.1
Chen, Y.2
Hsiung, P.3
Ippen, E.P.4
Fujimoto, J.G.5
-
207
-
-
1342292102
-
Real-time multi-functional optical coherence tomography
-
B. H. Park, M. C. Pierce, B. Cense, and J. F. de Boer, "Real-time multi-functional optical coherence tomography," Opt. Express 11(7), 782-793 (2003).
-
(2003)
Opt. Express
, vol.11
, Issue.7
, pp. 782-793
-
-
Park, B.H.1
Pierce, M.C.2
Cense, B.3
De Boer, J.F.4
-
208
-
-
0000372071
-
Real-time in vivo imaging of human gastrointestinal ultrastructure by use of endoscopic optical coherence tomography with a novel efficient interferometer design
-
A. M. Rollins, R. Ung-arunyawee, A. Chak, R. C. K. Wong, K. Kobayashi, M. V. Sivak, and J. A. Izatt, "Real-time in vivo imaging of human gastrointestinal ultrastructure by use of endoscopic optical coherence tomography with a novel efficient interferometer design," Opt. Lett. 24(19), 1358-1360 (1999).
-
(1999)
Opt. Lett.
, vol.24
, Issue.19
, pp. 1358-1360
-
-
Rollins, A.M.1
Ung-Arunyawee, R.2
Chak, A.3
Wong, R.C.K.4
Kobayashi, K.5
Sivak, M.V.6
Izatt, J.A.7
-
209
-
-
4043126029
-
In vivo video rate optical coherence tomography
-
A. M. Rollins, M. D. Kulkarni, S. Yazdanfar, R. Ung-arunyawee, and J. A. Izatt, "In vivo video rate optical coherence tomography," Opt. Express 3(6), 219-229 (1998).
-
(1998)
Opt. Express
, vol.3
, Issue.6
, pp. 219-229
-
-
Rollins, A.M.1
Kulkarni, M.D.2
Yazdanfar, S.3
Ung-Arunyawee, R.4
Izatt, J.A.5
-
210
-
-
33749458697
-
Real-time quadrature projection complex conjugate resolved Fourier domain optical coherence tomography
-
DOI 10.1364/OL.31.002426
-
M. V. Sarunic, B. E. Applegate, and J. A. Izatt, "Real-time quadrature projection complex conjugate resolved Fourier domain optical coherence tomography," Opt. Lett. 31(16), 2426-2428 (2006). (Pubitemid 44517649)
-
(2006)
Optics Letters
, vol.31
, Issue.16
, pp. 2426-2428
-
-
Sarunic, M.V.1
Applegate, B.E.2
Izatt, J.A.3
-
211
-
-
0141928808
-
Real-time in vivo imaging by high-speed spectral optical coherence tomography
-
M. Wojtkowski, T. Bajraszewski, P. Targowski, and A. Kowalczyk, "Real-time in vivo imaging by high-speed spectral optical coherence tomography," Opt. Lett. 28(19), 1745-1747 (2003).
-
(2003)
Opt. Lett.
, vol.28
, Issue.19
, pp. 1745-1747
-
-
Wojtkowski, M.1
Bajraszewski, T.2
Targowski, P.3
Kowalczyk, A.4
-
212
-
-
1042290601
-
High speed, wide velocity dynamic range Doppler optical coherence tomography (Part I(: System design, signal processing, and performance
-
V. X. D. Yang, M. L. Gordon, B. Qi, J. Pekar, S. Lo, E. Seng-Yue, A. Mok, B. C. Wilson, and I. A. Vitkin, "High speed, wide velocity dynamic range Doppler optical coherence tomography (Part I(: system design, signal processing, and performance," Opt. Express 11(7), 794-809 (2003).
-
(2003)
Opt. Express
, vol.11
, Issue.7
, pp. 794-809
-
-
Yang, V.X.D.1
Gordon, M.L.2
Qi, B.3
Pekar, J.4
Lo, S.5
Seng-Yue, E.6
Mok, A.7
Wilson, B.C.8
Vitkin, I.A.9
-
213
-
-
0000888516
-
Real-time detection technique for Doppler optical coherence tomography
-
A. V. Zvyagin, J. B. FitzGerald, K. K. M. B. D. Silva, and D. D. Sampson, "Real-time detection technique for Doppler optical coherence tomography," Opt. Lett. 25(22), 1645-1647 (2000).
-
(2000)
Opt. Lett.
, vol.25
, Issue.22
, pp. 1645-1647
-
-
Zvyagin, A.V.1
Fitzgerald, J.B.2
Silva, K.K.M.B.D.3
Sampson, D.D.4
-
214
-
-
0001936881
-
Measurement of intraocular distances by backscattering spectral interferometry
-
A. F. Fercher, C. K. Hitzenberger, G. Kamp, and S. Y. El-Zaiat, "Measurement of intraocular distances by backscattering spectral interferometry," Opt. Commun. 117(1-2), 43-48 (1995).
-
(1995)
Opt. Commun.
, vol.117
, Issue.1-2
, pp. 43-48
-
-
Fercher, A.F.1
Hitzenberger, C.K.2
Kamp, G.3
El-Zaiat, S.Y.4
-
215
-
-
0031695986
-
Coherence radar and spectral radar - New tools for dermatological diagnosis
-
G. Häusler and M. W. Lindner, "'Coherence' radar and 'spectral radar'-New tools for dermatological diagnosis," J. Biomed. Opt. 3(1), 21-31 (1998). (Pubitemid 128634973)
-
(1998)
Journal of Biomedical Optics
, vol.3
, Issue.1
, pp. 21-31
-
-
Hausler, G.1
Lindner, M.W.2
-
216
-
-
2942717185
-
Ultrahigh-resolution Fourier domain optical coherence tomography
-
R. A. Leitgeb, W. Drexler, A. Unterhuber, B. Hermann, T. Bajraszewski, T. Le, A. Stingl, and A. F. Fercher, "Ultrahigh-resolution Fourier domain optical coherence tomography," Opt. Express 12(10), 2156-2165 (2004).
-
(2004)
Opt. Express
, vol.12
, Issue.10
, pp. 2156-2165
-
-
Leitgeb, R.A.1
Drexler, W.2
Unterhuber, A.3
Hermann, B.4
Bajraszewski, T.5
Le, T.6
Stingl, A.7
Fercher, A.F.8
-
217
-
-
2942726216
-
Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation
-
M. Wojtkowski, V. J. Srinivasan, T. H. Ko, J. G. Fujimoto, A. Kowalczyk, and J. S. Duker, "Ultrahigh-resolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation," Opt. Express 12(11), 2404-2422 (2004).
-
(2004)
Opt. Express
, vol.12
, Issue.11
, pp. 2404-2422
-
-
Wojtkowski, M.1
Srinivasan, V.J.2
Ko, T.H.3
Fujimoto, J.G.4
Kowalczyk, A.5
Duker, J.S.6
-
218
-
-
33744731417
-
Spectroscopic spectral-domain optical coherence microscopy
-
DOI 10.1364/OL.31.001079
-
C. Xu, C. Vinegoni, T. S. Ralston, W. Luo, W. Tan, and S. A. Boppart, "Spectroscopic spectral-domain optical coherence microscopy," Opt. Lett. 31(8), 1079-1081 (2006). (Pubitemid 43837458)
-
(2006)
Optics Letters
, vol.31
, Issue.8
, pp. 1079-1081
-
-
Xu, C.1
Vinegoni, C.2
Ralston, T.S.3
Luo, W.4
Tan, W.5
Boppart, S.A.6
-
219
-
-
2942715001
-
High-speed spectral-domain optical coherence tomography at 1.3 (m wavelength
-
S. H. Yun, G. J. Tearney, B. E. Bouma, B. H. Park, and J. F. de Boer, "High-speed spectral-domain optical coherence tomography at 1.3 (m wavelength," Opt. Express 11(30), 3598-3604 (2003).
-
(2003)
Opt. Express
, vol.11
, Issue.30
, pp. 3598-3604
-
-
Yun, S.H.1
Tearney, G.J.2
Bouma, B.E.3
Park, B.H.4
De Boer, J.F.5
-
220
-
-
32344433268
-
Signal-to-noise ratio study of full-field Fourier-domain optical coherence tomography
-
DOI 10.1364/AO.44.007722
-
P. Blazkiewicz, M. Gourlay, J. R. Tucker, A. D. Rakic, and A. V. Zvyagin, "Signal-to-noise ratio study of full-field Fourier-domain optical coherence tomography," Appl. Opt. 44(36), 7722-7729 (2005). (Pubitemid 43216968)
-
(2005)
Applied Optics
, vol.44
, Issue.36
, pp. 7722-7729
-
-
Blazkiewicz, P.1
Gourlay, M.2
Tucker, J.R.3
Rakic, A.D.4
Zvyagin, A.V.5
-
221
-
-
0242301675
-
Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography
-
J. F. de Boer, B. Cense, B. H. Park, M. C. Pierce, G. J. Tearney, and B. E. Bouma, "Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography," Opt. Lett. 28(21), 2067-2069 (2003).
-
(2003)
Opt. Lett.
, vol.28
, Issue.21
, pp. 2067-2069
-
-
De Boer, J.F.1
Cense, B.2
Park, B.H.3
Pierce, M.C.4
Tearney, G.J.5
Bouma, B.E.6
-
222
-
-
0038618462
-
Performance of fourier domain vs time domain optical coherence tomography
-
R. Leitgeb, C. K. Hitzenberger, and A. F. Fercher, "Performance of fourier domain vs. time domain optical coherence tomography," Opt. Express 11(8), 889-894 (2003).
-
(2003)
Opt. Express
, vol.11
, Issue.8
, pp. 889-894
-
-
Leitgeb, R.1
Hitzenberger, C.K.2
Fercher, A.F.3
-
223
-
-
0000063301
-
Optical coherence tomography using a frequency-tunable optical source
-
S. R. Chinn, E. A. Swanson, and J. G. Fujimoto, "Optical coherence tomography using a frequency-tunable optical source," Opt. Lett. 22(5), 340-342 (1997). (Pubitemid 127581717)
-
(1997)
Optics Letters
, vol.22
, Issue.5
, pp. 340-342
-
-
Chinn, S.R.1
Swanson, E.A.2
Fujimoto, J.G.3
-
224
-
-
2942703878
-
Sensitivity advantage of swept source and Fourier domain optical coherence tomography
-
M. A. Choma, M. V. Sarunic, C. Yang, and J. A. Izatt, "Sensitivity advantage of swept source and Fourier domain optical coherence tomography," Opt. Express 11(18), 2183-2189 (2003).
-
(2003)
Opt. Express
, vol.11
, Issue.18
, pp. 2183-2189
-
-
Choma, M.A.1
Sarunic, M.V.2
Yang, C.3
Izatt, J.A.4
-
225
-
-
0001395165
-
4+:Forsterite laser
-
B. Golubovic, B. E. Bouma, G. J. Tearney, and J. G. Fujimoto, "Optical frequency-domain reflectometry using rapid wavelength tuning of a Cr4+ : forsterite laser," Opt. Lett. 22(22), 1704-1706 (1997). (Pubitemid 127562138)
-
(1997)
Optics Letters
, vol.22
, Issue.22
, pp. 1704-1706
-
-
Golubovic, B.1
Bouma, B.E.2
Tearney, G.J.3
Fujimoto, J.G.4
-
226
-
-
0032114755
-
Chirp optical coherence tomography of layered scattering media
-
U. H. P. Haberland, V. Blazek, and H. J. Schmitt, "Chirp optical coherence tomography of layered scattering media," J. Biomed. Opt. 3(3), 259-266 (1998). (Pubitemid 128634999)
-
(1998)
Journal of Biomedical Optics
, vol.3
, Issue.3
, pp. 259-266
-
-
Haberland, U.H.P.1
Blazek, V.2
Schmitt, H.J.3
-
227
-
-
29244448274
-
Three-dimensional and C-mode OCT imaging with a compact, frequency swept laser source at 1300 nm
-
R. Huber, M. Wojtkowski, J. G. Fujimoto, J. Y. Jiang, and A. E. Cable, "Three-dimensional and C-mode OCT imaging with a compact, frequency swept laser source at 1300 nm," Opt. Express 13(26), 10523-10538 (2005).
-
(2005)
Opt. Express
, vol.13
, Issue.26
, pp. 10523-10538
-
-
Huber, R.1
Wojtkowski, M.2
Fujimoto, J.G.3
Jiang, J.Y.4
Cable, A.E.5
-
228
-
-
33645820443
-
Fourier Domain Mode Locking (FDML(: A new laser operating regime and applications for optical coherence tomography
-
R. Huber, M. Wojtkowski, and J. G. Fujimoto, "Fourier Domain Mode Locking (FDML(: A new laser operating regime and applications for optical coherence tomography," Opt. Express 14(8), 3225-3237 (2006).
-
(2006)
Opt. Express
, vol.14
, Issue.8
, pp. 3225-3237
-
-
Huber, R.1
Wojtkowski, M.2
Fujimoto, J.G.3
-
229
-
-
33750506518
-
Buffered Fourier domain mode locking: Unidirectional swept laser sources for optical coherence tomography imaging at 370,000 lines/s
-
DOI 10.1364/OL.31.002975
-
R. Huber, D. C. Adler, and J. G. Fujimoto, "Buffered Fourier domain mode locking: unidirectional swept laser sources for optical coherence tomography imaging at 370,000 lines/s," Opt. Lett. 31(20), 2975-2977 (2006). (Pubitemid 44664580)
-
(2006)
Optics Letters
, vol.31
, Issue.20
, pp. 2975-2977
-
-
Huber, R.1
Adler, D.C.2
Fujimoto, J.G.3
-
230
-
-
34247196842
-
Ultra-high-speed optical coherence tomography with a stretched pulse supercontinuum source
-
DOI 10.1364/OE.14.011575
-
S. Moon and D. Y. Kim, "Ultra-high-speed optical coherence tomography with a stretched pulse supercontinuum source," Opt. Express 14(24), 11575-11584 (2006). (Pubitemid 44826841)
-
(2006)
Optics Express
, vol.14
, Issue.24
, pp. 11575-11584
-
-
Moon, S.1
Kim, D.Y.2
-
231
-
-
0345816228
-
Digital signal processing in optical coherence tomography
-
M. D. Kulkarni and J. A. Izatt, "Digital signal processing in optical coherence tomography," Proc. SPIE 2981, pp. 2-6 (1997).
-
(1997)
Proc. SPIE
, vol.2981
, pp. 2-6
-
-
Kulkarni, M.D.1
Izatt, J.A.2
-
232
-
-
21844446833
-
Optical Doppler coherence Tomography based on a Field Programmable Gate Array
-
DOI 10.1117/12.592760, 46, Coherence Domain Optical Methods and Optical Coherence Tomography in Biomedicine IX
-
H. E. Larsen, R. T. Nilsson, L. Thrane, D. K. Kristensen, F. Pedersen, T. M. Jorgensen, A. Gualdino, and P. E. Andersen, "Optical Doppler coherence tomography based on a field-programmable gate array," Proc. SPIE 5690, pp. 263-270 (2005). (Pubitemid 40953702)
-
(2005)
Progress in Biomedical Optics and Imaging - Proceedings of SPIE
, vol.5690
, pp. 263-270
-
-
Larsen, H.E.1
Nilsson, R.T.2
Thrane, L.3
Kristensen, D.K.4
Pedersen, F.5
Jorgensen, T.M.6
Gualdino, A.7
Andersen, P.E.8
-
233
-
-
0345724976
-
DSP-based optical Doppler tomography system for real-time signal processing
-
S. Yan, D. Piao, Y. Chen, and Q. Zhu, "DSP-based optical Doppler tomography system for real-time signal processing," Proc. SPIE 4956, pp. 187-196 (2003).
-
(2003)
Proc. SPIE
, vol.4956
, pp. 187-196
-
-
Yan, S.1
Piao, D.2
Chen, Y.3
Zhu, Q.4
-
234
-
-
2942718973
-
Digital signal processorbased real-time optical Doppler tomography system
-
S. Yan, D. Piao, Y. Chen, and Q. Zhu, "Digital signal processorbased real-time optical Doppler tomography system," J. Biomed. Opt. 9(3), 454-463 (2004).
-
(2004)
J. Biomed. Opt.
, vol.9
, Issue.3
, pp. 454-463
-
-
Yan, S.1
Piao, D.2
Chen, Y.3
Zhu, Q.4
-
235
-
-
12144252871
-
Real-time digital design for an optical coherence tomography acquisition and processing system
-
DOI 10.1117/12.527829, 31, Three-Dimensional and Multidimensional Microscopy: Image Acquisition and Processing XI
-
T. S. Ralston, J. A. Mayen, D. L. Marks, and S. A. Boppart, "Realtime digital design for an optical coherence tomography acquisition and processing system," Proc. SPIE 5324, pp. 159-170 (2004). (Pubitemid 40108924)
-
(2004)
Progress in Biomedical Optics and Imaging - Proceedings of SPIE
, vol.5
, Issue.13
, pp. 159-170
-
-
Ralston, T.S.1
Mayen, J.A.2
Marks, D.3
Boppart, S.A.4
-
236
-
-
0346887204
-
Real-time digital signal processing-based optical coherence tomography and doppler optical coherence tomography
-
DOI 10.1109/TBME.2003.820369
-
A. W. Schaefer, J. J. Reynolds, D. L. Marks, and S. A. Boppart, "Real-time digital signal processing-based optical coherence tomography and Doppler optical coherence tomography," IEEE Trans. Biomed. Eng. 51(1), 186-190 (2004). (Pubitemid 38009977)
-
(2004)
IEEE Transactions on Biomedical Engineering
, vol.51
, Issue.1
, pp. 186-190
-
-
Schaefer, A.W.1
Reynolds, J.J.2
Marks, D.L.3
Boppart, S.A.4
-
237
-
-
0036273210
-
Real-time, high velocity-resolution color Doppler optical coherence tomography
-
V. Westphal, S. Yazdanfar, A. M. Rollins, and J. A. Izatt, "Realtime, high velocity-resolution color Doppler optical coherence tomography," Opt. Lett. 27(1), 34-36 (2002). (Pubitemid 34617939)
-
(2002)
Optics Letters
, vol.27
, Issue.1
, pp. 34-36
-
-
Westphal, V.1
Yazdanfar, S.2
Rollins, A.M.3
Izatt, J.A.4
-
238
-
-
4644246854
-
Three dimensional polarization sensitive OCT of human skin in vivo
-
M. Pircher, E. Goetzinger, R. Leitgeb, and C. K. Hitzenberger, "Three dimensional polarization sensitive OCT of human skin in vivo," Opt. Express 12(14), 3236-3244 (2004).
-
(2004)
Opt. Express
, vol.12
, Issue.14
, pp. 3236-3244
-
-
Pircher, M.1
Goetzinger, E.2
Leitgeb, R.3
Hitzenberger, C.K.4
-
239
-
-
0009546753
-
An optical coherence microscope for 3-dimensional imaging in developmental biology
-
B. M. Hoeling, A. D. Fernandez, R. C. Haskell, E. Huang, W. R. Myers, D. C. Petersen, S. E. Ungersma, R. Wang, M. E. Williams, and S. E. Fraser, "An optical coherence microscope for 3-dimensional imaging in developmental biology," Opt. Express 6(7), 136-146 (2000).
-
(2000)
Opt. Express
, vol.6
, Issue.7
, pp. 136-146
-
-
Hoeling, B.M.1
Fernandez, A.D.2
Haskell, R.C.3
Huang, E.4
Myers, W.R.5
Petersen, D.C.6
Ungersma, S.E.7
Wang, R.8
Williams, M.E.9
Fraser, S.E.10
-
240
-
-
10444261997
-
Optical coherence tomography using a continuous-wave, high-power, Raman continuum light source
-
P. L. Hsiung, Y. Chen, T. H. Ko, J. G. Fujimoto, C. J. S. de Matos, S. V. Popov, J. R. Taylor, and V. P. Gapontsev, "Optical coherence tomography using a continuous-wave, high-power, Raman continuum light source," Opt. Express 12(22), 5287-5295 (2004).
-
(2004)
Opt. Express
, vol.12
, Issue.22
, pp. 5287-5295
-
-
Hsiung, P.L.1
Chen, Y.2
Ko, T.H.3
Fujimoto, J.G.4
De Matos, C.J.S.5
Popov, S.V.6
Taylor, J.R.7
Gapontsev, V.P.8
-
241
-
-
2442677892
-
Structural and functional imaging of 3D microfluidic mixers using optical coherence tomography
-
DOI 10.1073/pnas.0402433101
-
C. Xi, D. L. Marks, D. S. Parikh, L. Raskin, and S. A. Boppart, "Structural and functional imaging of 3D microfluidic mixers using optical coherence tomography," Proc. Natl. Acad. Sci. U.S.A. 101(20), 7516-7521 (2004). (Pubitemid 38658060)
-
(2004)
Proceedings of the National Academy of Sciences of the United States of America
, vol.101
, Issue.20
, pp. 7516-7521
-
-
Xi, C.1
Marks, D.L.2
Parikh, D.S.3
Raskin, L.4
Boppart, S.A.5
-
242
-
-
33748452516
-
Highresolution three-dimensional imaging of biofilm development using optical coherence tomography
-
C. Xi, D. Marks, S. Schlachter, W. Luo, and S. A. Boppart, "Highresolution three-dimensional imaging of biofilm development using optical coherence tomography," J. Biomed. Opt. 11(3), 034001 (2006).
-
(2006)
J. Biomed. Opt.
, vol.11
, Issue.3
, pp. 034001
-
-
Xi, C.1
Marks, D.2
Schlachter, S.3
Luo, W.4
Boppart, S.A.5
-
243
-
-
33745277630
-
Inverse scattering for optical coherence tomography
-
T. S. Ralston, D. L. Marks, P. S. Carney, and S. A. Boppart, "Inverse scattering for optical coherence tomography," J. Opt. Soc. Am. A Opt. Image Sci. Vis 32(5), 1027-1037 (2006).
-
(2006)
J. Opt. Soc. Am. A Opt. Image Sci. Vis
, vol.32
, Issue.5
, pp. 1027-1037
-
-
Ralston, T.S.1
Marks, D.L.2
Carney, P.S.3
Boppart, S.A.4
-
244
-
-
33846783134
-
Interferometric synthetic aperture microscopy
-
T. S. Ralston, D. L. Marks, P. S. Carney, and S. A. Boppart, "Interferometric synthetic aperture microscopy," Nat. Phys. 3(2), 129-134 (2007).
-
(2007)
Nat. Phys.
, vol.3
, Issue.2
, pp. 129-134
-
-
Ralston, T.S.1
Marks, D.L.2
Carney, P.S.3
Boppart, S.A.4
-
245
-
-
33846170489
-
Inverse scattering for high-resolution interferometric microscopy
-
DOI 10.1364/OL.31.003585
-
T. S. Ralston, D. L. Marks, S. A. Boppart, and P. S. Carney, "Inverse scattering for high-resolution interferometric microscopy," Opt. Lett. 31(24), 3585-3587 (2006). (Pubitemid 46079710)
-
(2006)
Optics Letters
, vol.31
, Issue.24
, pp. 3585-3587
-
-
Ralston, T.S.1
Marks, D.L.2
Boppart, S.A.3
Scott Carney, P.4
-
246
-
-
33751232003
-
Inverse scattering for rotationally scanned optical coherence tomography
-
DOI 10.1364/JOSAA.23.002433
-
D. L. Marks, T. S. Ralston, P. S. Carney, and S. A. Boppart, "Inverse scattering for rotationally scanned optical coherence tomography," J. Opt. Soc. Am. A Opt. Image Sci. Vis. 23(10), 2433-2439 (2006). (Pubitemid 44781644)
-
(2006)
Journal of the Optical Society of America A: Optics and Image Science, and Vision
, vol.23
, Issue.10
, pp. 2433-2439
-
-
Marks, D.L.1
Ralston, T.S.2
Carney, P.S.3
Boppart, S.A.4
-
247
-
-
34248356852
-
Inverse scattering for frequency-scanned full-field optical coherence tomography
-
DOI 10.1364/JOSAA.24.001034
-
D. L. Marks, T. S. Ralston, S. A. Boppart, and P. S. Carney, "Inverse scattering for frequency-scanned full-field optical coherence tomography," J. Opt. Soc. Am. A Opt. Image Sci. Vis. 24(4), 1034-1041 (2007). (Pubitemid 46730868)
-
(2007)
Journal of the Optical Society of America A: Optics and Image Science, and Vision
, vol.24
, Issue.4
, pp. 1034-1041
-
-
Marks, D.L.1
Ralston, T.S.2
Boppart, S.A.3
Carney, P.S.4
-
248
-
-
1642602745
-
Ultrahigh-resolution optical coherence tomography
-
W. Drexler, "Ultrahigh-resolution optical coherence tomography," J. Biomed. Opt. 9(1), 47-74 (2004).
-
(2004)
J. Biomed. Opt.
, vol.9
, Issue.1
, pp. 47-74
-
-
Drexler, W.1
-
249
-
-
0034322656
-
A thermal light source technique for optical coherence tomography
-
A. F. Fercher, C. K. Hitzenberger, M. Sticker, E. Moreno-Barriuso, R. Leitgeb, W. Drexler, and H. Sattmann, "A thermal light source technique for optical coherence tomography," Opt. Commun. 185(1), 57-64 (2000).
-
(2000)
Opt. Commun.
, vol.185
, Issue.1
, pp. 57-64
-
-
Fercher, A.F.1
Hitzenberger, C.K.2
Sticker, M.3
Moreno-Barriuso, E.4
Leitgeb, R.5
Drexler, W.6
Sattmann, H.7
-
250
-
-
0036542317
-
Thermal-light full-field optical coherence tomography
-
L. Vabre, A. Dubois, and A. C. Boccara, "Thermal-light full-field optical coherence tomography," Opt. Lett. 27(7), 530-532 (2002). (Pubitemid 34618166)
-
(2002)
Optics Letters
, vol.27
, Issue.7
, pp. 530-532
-
-
Vabre, L.1
Dubois, A.2
Boccara, A.C.3
-
251
-
-
20444475658
-
Stroboscopic ultrahigh-resolution full-field optical coherence tomography
-
G. Moneron, A. C. Boccara, and A. Dubois, "Stroboscopic ultrahigh-resolution full-field optical coherence tomography," Opt. Lett. 30(11), 1351-1353 (2005). (Pubitemid 40818562)
-
(2005)
Optics Letters
, vol.30
, Issue.11
, pp. 1351-1353
-
-
Moneron, G.1
Boccara, A.C.2
Dubois, A.3
-
252
-
-
0031647395
-
Signal and resolution enhancements in dual beam optical coherence tomography of the human eye
-
A. Baumgartner, C. K. Hitzenberger, H. Sattmann, W. Drexler, and A. F. Fercher, "Signal and resolution enhancements in dual beam optical coherence tomography of the human eye," J. Biomed. Opt. 3(1), 45-54 (1998). (Pubitemid 128634976)
-
(1998)
Journal of Biomedical Optics
, vol.3
, Issue.1
, pp. 45-54
-
-
Baumgartner, A.1
Hitzenberger, C.K.2
Sattmann, H.3
Drexler, W.4
Fercher, A.F.5
-
253
-
-
2942726534
-
Ultrahigh resolution optical coherence tomography imaging with a broadband superluminescent diode light source
-
T. H. Ko, D. C. Adler, J. G. Fujimoto, D. Mamedov, V. Prokhorov, V. Shidlovski, and S. Yakubovich, "Ultrahigh resolution optical coherence tomography imaging with a broadband superluminescent diode light source," Opt. Express 12(10), 2112-2119 (2004).
-
(2004)
Opt. Express
, vol.12
, Issue.10
, pp. 2112-2119
-
-
Ko, T.H.1
Adler, D.C.2
Fujimoto, J.G.3
Mamedov, D.4
Prokhorov, V.5
Shidlovski, V.6
Yakubovich, S.7
-
254
-
-
21244447412
-
In vivo retinal optical coherence tomography at 1040 nm - Enhanced penetration into the choroid
-
DOI 10.1364/OPEX.13.003252
-
A. Unterhuber, B. Považay, B. Hermann, H. Sattmann, A. Chavez- Pirson, and W. Drexler, "In vivo retinal optical coherence tomography at 1040 nm-enhanced penetration into the choroid," Opt. Express 13(9), 3252-3258 (2005). (Pubitemid 40899376)
-
(2005)
Optics Express
, vol.13
, Issue.9
, pp. 3252-3258
-
-
Unterhuber, A.1
Povazay, B.2
Hermann, B.3
Sattmann, H.4
Chavez-Pirson, A.5
Drexler, W.6
-
255
-
-
0001673084
-
Ultrahigh resolution optical coherence tomography using a superluminescent light source
-
A. M. Kowalevicz, T. Ko, I. Hartl, J. G. Fujimoto, M. Pollnau, and R. P. Salathé, "Ultrahigh resolution optical coherence tomography using a superluminescent light source," Opt. Express 10(7), 349-353 (2002).
-
(2002)
Opt. Express
, vol.10
, Issue.7
, pp. 349-353
-
-
Kowalevicz, A.M.1
Ko, T.2
Hartl, I.3
Fujimoto, J.G.4
Pollnau, M.5
Salathé, R.P.6
-
256
-
-
84975582245
-
High-resolution optical coherence tomographic imaging using a mode-locked Ti:Al2O3 laser source
-
B. Bouma, G. J. Tearney, S. A. Boppart, M. R. Hee, M. E. Brezinski, and J. G. Fujimoto, "High-resolution optical coherence tomographic imaging using a mode-locked Ti:Al2O3 laser source," Opt. Lett. 20(13), 1486-1488 (1995).
-
(1995)
Opt. Lett.
, vol.20
, Issue.13
, pp. 1486-1488
-
-
Bouma, B.1
Tearney, G.J.2
Boppart, S.A.3
Hee, M.R.4
Brezinski, M.E.5
Fujimoto, J.G.6
-
257
-
-
0032613799
-
In vivo ultrahigh-resolution optical coherence tomography
-
W. Drexler, U. Morgner, F. X. Kärtner, C. Petris, S. A. Boppart, X. D. Li, E. P. Ippen, and J. G. Fujimoto, "In vivo ultrahigh-resolution optical coherence tomography," Opt. Lett. 24(17), 1221-1223 (1999). (Pubitemid 129304397)
-
(1999)
Optics Letters
, vol.24
, Issue.17
, pp. 1221-1223
-
-
Drexler, W.1
Morgner, U.2
Kartner, F.X.3
Pitris, C.4
Boppart, S.A.5
Li, X.D.6
Ippen, E.P.7
Fujimoto, J.G.8
-
258
-
-
0038137068
-
Compact, low-cost Ti:Al2O3 laser for in vivo ultrahigh-resolution optical coherence tomography
-
A. Unterhuber, B. Považay, B. Hermann, H. Sattmann, W. Drexler, V. Yakovlev, G. Tempea, C. Schubert, E. M. Anger, P. K. Ahnelt, M. Stur, J. E. Morgan, A. Cowey, G. Jung, T. Le, and A. Stingl, "Compact, low-cost Ti:Al2O3 laser for in vivo ultrahigh-resolution optical coherence tomography," Opt. Lett. 28(11), 905-907 (2003).
-
(2003)
Opt. Lett.
, vol.28
, Issue.11
, pp. 905-907
-
-
Unterhuber, A.1
Považay, B.2
Hermann, B.3
Sattmann, H.4
Drexler, W.5
Yakovlev, V.6
Tempea, G.7
Schubert, C.8
Anger, E.M.9
Ahnelt, P.K.10
Stur, M.11
Morgan, J.E.12
Cowey, A.13
Jung, G.14
Le, T.15
Stingl, A.16
-
259
-
-
0037113247
-
Ultralow-threshold Kerr-lens mode-locked Ti:Al2O3 laser
-
A. M. Kowalevicz, T. R. Schibli, F. X. Kärtner, and J. G. Fujimoto, "Ultralow-threshold Kerr-lens mode-locked Ti:Al2O3 laser," Opt. Lett. 27(22), 2037-2039 (2002).
-
(2002)
Opt. Lett.
, vol.27
, Issue.22
, pp. 2037-2039
-
-
Kowalevicz, A.M.1
Schibli, T.R.2
Kärtner, F.X.3
Fujimoto, J.G.4
-
260
-
-
2942714981
-
Ultrahigh resolution real time OCT imaging using a compact femtosecond Nd:Glass laser and nonlinear fiber
-
S. Bourquin, A. D. Aguirre, I. Hartl, P. Hsiung, T. H. Ko, J. G. Fujimoto, T. A. Birks, W. J. Wadsworth, U. Bünting, and D. Kopf, "Ultrahigh resolution real time OCT imaging using a compact femtosecond Nd:Glass laser and nonlinear fiber," Opt. Express 11(24), 3290-3297 (2003).
-
(2003)
Opt. Express
, vol.11
, Issue.24
, pp. 3290-3297
-
-
Bourquin, S.1
Aguirre, A.D.2
Hartl, I.3
Hsiung, P.4
Ko, T.H.5
Fujimoto, J.G.6
Birks, T.A.7
Wadsworth, W.J.8
Bünting, U.9
Kopf, D.10
-
261
-
-
4644260407
-
Ultrahigh-resolution optical coherence tomography with a diode-pumped broadband Cr3+ :LiCAF laser
-
P. C. Wagenblast, T. H. Ko, J. G. Fujimoto, F. X. Kaertner, and U. Morgner, "Ultrahigh-resolution optical coherence tomography with a diode-pumped broadband Cr3+ :LiCAF laser," Opt. Express 12(14), 3257-3263 (2004).
-
(2004)
Opt. Express
, vol.12
, Issue.14
, pp. 3257-3263
-
-
Wagenblast, P.C.1
Ko, T.H.2
Fujimoto, J.G.3
Kaertner, F.X.4
Morgner, U.5
-
262
-
-
0038029572
-
Compact, broad-bandwidth fiber laser for sub-2-(m axial resolution optical coherence tomography in the 1300-nm wavelength region
-
K. Bizheva, B. Považay, B. Hermann, H. Sattmann, W. Drexler, M. Mei, R. Holzwarth, T. Hoelzenbein, V. Wacheck, and H. Pehamberger, "Compact, broad-bandwidth fiber laser for sub-2-(m axial resolution optical coherence tomography in the 1300-nm wavelength region," Opt. Lett. 28(9), 707-709 (2003).
-
(2003)
Opt. Lett.
, vol.28
, Issue.9
, pp. 707-709
-
-
Bizheva, K.1
Považay, B.2
Hermann, B.3
Sattmann, H.4
Drexler, W.5
Mei, M.6
Holzwarth, R.7
Hoelzenbein, T.8
Wacheck, V.9
Pehamberger, H.10
-
263
-
-
0031876356
-
In vivo cellular optical coherence tomography imaging
-
DOI 10.1038/nm0798-861
-
S. A. Boppart, B. E. Bouma, C. Pitris, J. F. Southern, M. E. Brezinski, and J. G. Fujimoto, "In vivo cellular optical coherence tomography imaging," Nat. Med. 4(7), 861-865 (1998). (Pubitemid 28331032)
-
(1998)
Nature Medicine
, vol.4
, Issue.7
, pp. 861-865
-
-
Boppart, S.A.1
Bouma, B.E.2
Pitris, C.3
Southern, J.F.4
Brezinski, M.E.5
Fujimoto, J.G.6
-
264
-
-
0000950973
-
Self-phase-modulated Kerr-lens mode-locked Cr:forsterite laser source for optical coherence tomography
-
B. E. Bouma, G. J. Tearney, I. P. Bilinsky, B. Golubovic, and J. G. Fujimoto, "Self-phase-modulated Kerr-lens mode-locked Cr:forsterite laser source for optical coherence tomography," Opt. Lett. 21(22), 1839-1841 (1996). (Pubitemid 126569169)
-
(1996)
Optics Letters
, vol.21
, Issue.22
, pp. 1839-1841
-
-
Bouma, B.E.1
Tearney, G.J.2
Bilinsky, I.P.3
Golubovic, B.4
Fujimoto, J.G.5
-
265
-
-
0037113141
-
Study of an ultrahigh-numerical-aperture fiber continuum generation source for optical coherence tomography
-
D. L. Marks, A. L. Oldenburg, J. J. Reynolds, and S. A. Boppart, "Study of an ultrahigh-numerical-aperture fiber continuum generation source for optical coherence tomography," Opt. Lett. 27(22), 2010-2012 (2002).
-
(2002)
Opt. Lett.
, vol.27
, Issue.22
, pp. 2010-2012
-
-
Marks, D.L.1
Oldenburg, A.L.2
Reynolds, J.J.3
Boppart, S.A.4
-
266
-
-
23444442716
-
Low-noise broadband light generation from optical fibers for use in high-resolution optical coherence tomography
-
DOI 10.1364/JOSAA.22.001492
-
Y. Wang, I. Tomov, J. S. Nelson, Z. Chen, H. Lim, and F. Wise, "Low-noise broadband light generation from optical fibers for use in high-resolution optical coherence tomography," J. Opt. Soc. Am. A Opt. Image Sci. Vis. 22(8), 1492-1499 (2005). (Pubitemid 41107529)
-
(2005)
Journal of the Optical Society of America A: Optics and Image Science, and Vision
, vol.22
, Issue.8
, pp. 1492-1499
-
-
Wang, Y.1
Tomov, I.2
Nelson, J.S.3
Chen, Z.4
Lim, H.5
Wise, F.6
-
267
-
-
0003059846
-
Visible continuum generation in air-silica microstructure optical fibers with anomalous dispersion at 800 nm
-
J. K. Ranka, R. S. Windeler, and A. J. Stentz, "Visible continuum generation in air-silica microstructure optical fibers with anomalous dispersion at 800 nm," Opt. Lett. 25(1), 25-27 (2000). (Pubitemid 33638739)
-
(2000)
Optics Letters
, vol.25
, Issue.1
, pp. 25-27
-
-
Ranka, J.K.1
Windeler, R.S.2
Stentz, A.J.3
-
268
-
-
0000257687
-
Ultrahigh-resolution optical coherence tomography using continuum generation in an air-silica microstructure optical fiber
-
I. Hartl, X. D. Li, C. Chudoba, R. K. Ghanta, T. H. Ko, J. G. Fujimoto, J. K. Ranka, and R. S. Windeler, "Ultrahigh-resolution optical coherence tomography using continuum generation in an airsilica micro structure optical fiber," Opt. Lett. 26(9), 608-610 (2001). (Pubitemid 33693487)
-
(2001)
Optics Letters
, vol.26
, Issue.9
, pp. 608-610
-
-
Hartl, I.1
Li, X.D.2
Chudoba, C.3
Ghanta, R.K.4
Ko, T.H.5
Fujimoto, J.G.6
Ranka, J.K.7
Windeler, R.S.8
-
269
-
-
32644441456
-
Continuum generation in a novel photonic crystal fiber for ultrahigh resolution optical coherence tomography at 800 nm and 1300 nm
-
DOI 10.1364/OE.14.001145
-
A. D. Aguirre, N. Nishizawa, J. G. Fujimoto, W. Seitz, M. Lederer, and D. Kopf, "Continuum generation in a novel photonic crystal fiber for ultrahigh resolution optical coherence tomography at 800 nm and 1300 nm," Opt. Express 14(3), 1145-1160 (2006). (Pubitemid 43244432)
-
(2006)
Optics Express
, vol.14
, Issue.3
, pp. 1145-1160
-
-
Aguirre, A.D.1
Nishizawa, N.2
Fujimoto, J.G.3
Seitz, W.4
Lederer, M.5
Kopf, D.6
-
270
-
-
33144468607
-
Supercontinuum generation system for optical coherence tomography based on tapered photonic crystal fibre
-
DOI 10.1364/OE.14.001596
-
G. Humbert, W. J. Wadsworth, S. G. Leon-Saval, J. C. Knight, T. A. Birks, P. S. J. Russell, M. J. Lederer, D. Kopf, K. Wiesauer, E. I. Breuer, and D. Stifter, "Supercontinuum generation system for optical coherence tomography based on tapered photonic crystal fibre," Opt. Express 14(4), 1596-1603 (2006). (Pubitemid 43270824)
-
(2006)
Optics Express
, vol.14
, Issue.4
, pp. 1596-1603
-
-
Humbert, G.1
Wadsworth, W.J.2
Leon-Saval, S.G.3
Knight, J.C.4
Birks, T.A.5
Russell, P.St.J.6
Lederer, M.J.7
Kopf, D.8
Wiesauer, K.9
Breuer, E.I.10
Stifter, D.11
-
271
-
-
20444429767
-
Ultrahigh-resolution optical coherence tomography with a fiber laser source at 1 μm
-
DOI 10.1364/OL.30.001171
-
H. Lim, Y. Jiang, Y. Wang, Y. C. Huang, Z. Chen, and F. W. Wise, "Ultrahigh-resolution optical coherence tomography with a fiber laser source at 1 (m," Opt. Lett. 30(10), 1171-1173 (2005). (Pubitemid 40795097)
-
(2005)
Optics Letters
, vol.30
, Issue.10
, pp. 1171-1173
-
-
Lim, H.1
Jiang, Y.2
Wang, Y.3
Huang, Y.-C.4
Chen, Z.5
Wise, F.W.6
-
272
-
-
0037109470
-
Submicrometer axial resolution optical coherence tomography
-
B. Považay, K. Bizheva, A. Unterhuber, B. Hermann, H. Sattmann, A. F. Fercher, W. Drexler, A. Apolonski, W. J. Wadsworth, J. C. Knight, P. S. J. Russell, M. Vetterlein, and E. Scherzer, "Submicrometer axial resolution optical coherence tomography," Opt. Lett. 27(20), 1800-1802 (2002). (Pubitemid 35328915)
-
(2002)
Optics Letters
, vol.27
, Issue.20
, pp. 1800-1802
-
-
Povazay, B.1
Bizheva, K.2
Unterhuber, A.3
Hermann, B.4
Sattmann, H.5
Fercher, A.F.6
Drexler, W.7
Apolonski, A.8
Wadsworth, W.J.9
Knight, J.C.10
Russell, P.St.J.11
Vetterlein, M.12
Scherzer, E.13
-
273
-
-
1942455545
-
Enhanced visualization of choroidal vessels using ultrahigh resolution ophthalmic OCT at 1050 nm
-
B. Považay, K. Bizheva, B. Hermann, A. Unterhuber, H. Sattmann, A. F. Fercher, W. Drexler, C. Schubert, P. K. Ahnelt, M. Mei, R. Holzwarth, W. J. Wadsworth, J. C. Knight, and P. S. J. Russel, "Enhanced visualization of choroidal vessels using ultrahigh resolution ophthalmic OCT at 1050 nm," Opt. Express 11(17), 1980-1986 (2003).
-
(2003)
Opt. Express
, vol.11
, Issue.17
, pp. 1980-1986
-
-
Považay, B.1
Bizheva, K.2
Hermann, B.3
Unterhuber, A.4
Sattmann, H.5
Fercher, A.F.6
Drexler, W.7
Schubert, C.8
Ahnelt, P.K.9
Mei, M.10
Holzwarth, R.11
Wadsworth, W.J.12
Knight, J.C.13
Russel, P.S.J.14
-
274
-
-
0037320397
-
Ultrahigh-resolution optical coherence tomography by broadband continuum generation from a photonic crystal fiber
-
Y. Wang, Y. Zhao, J. S. Nelson, Z. Chen, and R. S. Windeler, "Ultrahigh-resolution optical coherence tomography by broadband continuum generation from a photonic crystal fiber," Opt. Lett. 28(3), 182-184 (2003).
-
(2003)
Opt. Lett.
, vol.28
, Issue.3
, pp. 182-184
-
-
Wang, Y.1
Zhao, Y.2
Nelson, J.S.3
Chen, Z.4
Windeler, R.S.5
-
275
-
-
2942738905
-
High-speed optical frequency-domain imaging
-
S. H. Yun, G. J. Tearney, J. F. de Boer, N. Iftimia, and B. E. Bouma, "High-speed optical frequency-domain imaging," Opt. Express 11(22), 2953-2963 (2003).
-
(2003)
Opt. Express
, vol.11
, Issue.22
, pp. 2953-2963
-
-
Yun, S.H.1
Tearney, G.J.2
De Boer, J.F.3
Iftimia, N.4
Bouma, B.E.5
-
276
-
-
10444241131
-
Pulsedsource and swept-source spectral-domain optical coherence tomography with reduced motion artifacts
-
S. H. Yun, G. J. Tearney, J. F. de Boer, and B. E. Bouma, "Pulsedsource and swept-source spectral-domain optical coherence tomography with reduced motion artifacts," Opt. Express 12(23), 5614-5624 (2004).
-
(2004)
Opt. Express
, vol.12
, Issue.23
, pp. 5614-5624
-
-
Yun, S.H.1
Tearney, G.J.2
De Boer, J.F.3
Bouma, B.E.4
-
277
-
-
29244445929
-
Swept source optical coherence tomography using an all-fiber 1300-nm ring laser source
-
M. A. Choma, K. Hsu, and J. A. Izatt, "Swept source optical coherence tomography using an all-fiber 1300-nm ring laser source," J. Biomed. Opt. 10(4), 044009 (2005).
-
(2005)
J. Biomed. Opt.
, vol.10
, Issue.4
, pp. 044009
-
-
Choma, M.A.1
Hsu, K.2
Izatt, J.A.3
-
278
-
-
21244433547
-
Amplified, frequency swept lasers for frequency domain reflectometry and OCT imaging: Design and scaling principles
-
DOI 10.1364/OPEX.13.003513
-
R. Huber, M. Wojtkowski, K. Taira, J. G. Fujimoto, and K. Hsu, "Amplified, frequency swept lasers for frequency domain reflectometry and OCT imaging: design and scaling principles," Opt. Express 13(9), 3513-3528 (2005). (Pubitemid 40899406)
-
(2005)
Optics Express
, vol.13
, Issue.9
, pp. 3513-3528
-
-
Huber, R.1
Wojtkowski, M.2
Taira, K.3
Fujimoto, J.G.4
Hsu, K.5
-
279
-
-
29244460597
-
Threedimensional and high-speed swept-source optical coherence tomography for in vivo investigation of human anterior eye segments
-
Y. Yasuno, V. D. Madjarova, S. Makita, M. Akiba, A. Morosawa, C. Chong, T. Sakai, K. P. Chan, M. Itoh, and T. Yatagai, "Threedimensional and high-speed swept-source optical coherence tomography for in vivo investigation of human anterior eye segments," Opt. Express 13(26), 10652-10664 (2005).
-
(2005)
Opt. Express
, vol.13
, Issue.26
, pp. 10652-10664
-
-
Yasuno, Y.1
Madjarova, V.D.2
Makita, S.3
Akiba, M.4
Morosawa, A.5
Chong, C.6
Sakai, T.7
Chan, K.P.8
Itoh, M.9
Yatagai, T.10
-
280
-
-
33646552709
-
In vivo optical frequency domain imaging of human retina and choroid
-
DOI 10.1364/OE.14.004403
-
E. C. W. Lee, J. F. de Boer, M. Mujat, H. Lim, and S. H. Yun, "In vivo optical frequency domain imaging of human retina and choroid," Opt. Express 14(10), 4403-4411 (2006). (Pubitemid 43727630)
-
(2006)
Optics Express
, vol.14
, Issue.10
, pp. 4403-4411
-
-
Lee, E.C.W.1
De Boer, J.F.2
Miyat, M.3
Lim, H.4
Yun, S.H.5
-
281
-
-
33845726046
-
High-speed imaging of human retina in vivo with swept-source optical coherence tomography
-
DOI 10.1364/OE.14.012902
-
H. Lim, M. Mujat, C. Kerbage, E. C. W. Lee, Y. Chen, T. C. Chen, and J. F. de Boer, "High-speed imaging of human retina in vivo with swept-source optical coherence tomography," Opt. Express 14(26), 12902-12908 (2006). (Pubitemid 46013364)
-
(2006)
Optics Express
, vol.14
, Issue.26
, pp. 12902-12908
-
-
Lim, H.1
Mujat, M.2
Kerbage, C.3
Lee, E.C.W.4
Chen, Y.5
Chen, T.C.6
De Boer, J.F.7
-
282
-
-
33745434066
-
Optical frequency domain imaging with a rapidly swept laser in the 815-870 nm range
-
H. Lim, J. F. de Boer, B. H. Park, E. C. W. Lee, R. Yelin, and S. H. Yun, "Optical frequency domain imaging with a rapidly swept laser in the 815-870 nm range," Opt. Express 14(13), 5937-5944 (2006).
-
(2006)
Opt. Express
, vol.14
, Issue.13
, pp. 5937-5944
-
-
Lim, H.1
De Boer, J.F.2
Park, B.H.3
Lee, E.C.W.4
Yelin, R.5
Yun, S.H.6
|