메뉴 건너뛰기




Volumn 15, Issue 8, 2007, Pages 4787-4794

Needle-based reflection refractometry of scattering samples using coherence-gated detection

Author keywords

[No Author keywords available]

Indexed keywords

COMPUTER SIMULATION; LIGHT POLARIZATION; LIGHT REFLECTION; LIGHT SCATTERING; MONTE CARLO METHODS; OPTICAL FIBERS; REFRACTOMETERS; SIGNAL DETECTION;

EID: 34247242745     PISSN: None     EISSN: 10944087     Source Type: Journal    
DOI: 10.1364/OE.15.004787     Document Type: Article
Times cited : (26)

References (30)
  • 1
    • 0036470305 scopus 로고    scopus 로고
    • Refractive index measurement and its applications
    • S. Singh, "Refractive index measurement and its applications," Physica Scripta 65, 167-180 (2002).
    • (2002) Physica Scripta , vol.65 , pp. 167-180
    • Singh, S.1
  • 3
    • 0029877594 scopus 로고    scopus 로고
    • The spatial variation of the refractive index in biological cells
    • J. Beuthan, O. Minet, J. Helfmann, M. Herrig, and G. Muller, "The spatial variation of the refractive index in biological cells," Phys. Med. Biol. 41, 369-382 (1996).
    • (1996) Phys. Med. Biol , vol.41 , pp. 369-382
    • Beuthan, J.1    Minet, O.2    Helfmann, J.3    Herrig, M.4    Muller, G.5
  • 5
    • 33645965545 scopus 로고    scopus 로고
    • Refractive index of carcinogen-induced rat mammary tumours
    • A. M. Zysk, E. J. Chaney, and S. A. Boppart, "Refractive index of carcinogen-induced rat mammary tumours," Phys. Med. Biol. 51, 2165-2177 (2006).
    • (2006) Phys. Med. Biol , vol.51 , pp. 2165-2177
    • Zysk, A.M.1    Chaney, E.J.2    Boppart, S.A.3
  • 6
    • 33845370158 scopus 로고    scopus 로고
    • Computational methods for analysis of human breast tumor tissue in optical coherence tomography images
    • A. M. Zysk, and S. A. Boppart, "Computational methods for analysis of human breast tumor tissue in optical coherence tomography images," J. Biomed. Opt. 11, 054015 (2006).
    • (2006) J. Biomed. Opt , vol.11 , pp. 054015
    • Zysk, A.M.1    Boppart, S.A.2
  • 7
    • 0033316488 scopus 로고    scopus 로고
    • The radiative transfer equation for scattering media with a spatially varying retractive index
    • H. A. Ferwerda, "The radiative transfer equation for scattering media with a spatially varying retractive index," J. Opt. A 1, L1-L2 (1999).
    • (1999) J. Opt. A , vol.1
    • Ferwerda, H.A.1
  • 9
    • 0242334234 scopus 로고    scopus 로고
    • Derivation of the radiative transfer equation for scattering media with a spatially varying refractive index
    • J.-M. Tualle, and E. Tinet, "Derivation of the radiative transfer equation for scattering media with a spatially varying refractive index," Opt. Commun. 228, 33-38 (2003).
    • (2003) Opt. Commun , vol.228 , pp. 33-38
    • Tualle, J.-M.1    Tinet, E.2
  • 10
    • 0042914826 scopus 로고    scopus 로고
    • The effects of internal refractive index variation in near-infrared optical tomography: A finite element modelling approach
    • H. Dehghani, B. Brooksby, K. Vishwanath, B. W. Pogue, and K. D. Paulsen, "The effects of internal refractive index variation in near-infrared optical tomography: a finite element modelling approach," Phys. Med. Biol. 48, 2713-2727 (2003).
    • (2003) Phys. Med. Biol , vol.48 , pp. 2713-2727
    • Dehghani, H.1    Brooksby, B.2    Vishwanath, K.3    Pogue, B.W.4    Paulsen, K.D.5
  • 11
    • 16644368107 scopus 로고    scopus 로고
    • Effects of refractive index on near-infrared tomography of the breast
    • H. Dehghani, B. A. Brooksby, B. W. Pogue, and K. D. Paulsen, "Effects of refractive index on near-infrared tomography of the breast," Appl. Opt. 44, 1870-1878 (2005).
    • (2005) Appl. Opt , vol.44 , pp. 1870-1878
    • Dehghani, H.1    Brooksby, B.A.2    Pogue, B.W.3    Paulsen, K.D.4
  • 12
    • 0034283507 scopus 로고    scopus 로고
    • In vitro simultaneous measurement of refractive index and thickness of biological tissue by the low coherence interferometry
    • M. Ohmi, Y. Ohnishi, K. Yoden, and M. Haruna, "In vitro simultaneous measurement of refractive index and thickness of biological tissue by the low coherence interferometry," IEEE Trans. Biomed. Eng. 47, 1266-1270 (2000).
    • (2000) IEEE Trans. Biomed. Eng , vol.47 , pp. 1266-1270
    • Ohmi, M.1    Ohnishi, Y.2    Yoden, K.3    Haruna, M.4
  • 13
    • 0026748008 scopus 로고
    • Simultaneous thickness and group index measurement using optical low-coherence reflectometry
    • W. V. Sorin, and D. F. Gray, "Simultaneous thickness and group index measurement using optical low-coherence reflectometry," IEEE Photon. Technol. Lett. 4, 105-107 (1992).
    • (1992) IEEE Photon. Technol. Lett , vol.4 , pp. 105-107
    • Sorin, W.V.1    Gray, D.F.2
  • 14
    • 69949102288 scopus 로고
    • Determination of the refractive index of highly scattering human tissue by optical coherence tomography
    • G. J. Tearney, M. E. Brezinski, J. F. Southern, B. E. Bouma, M. R. Hee, and J. G. Fujimoto, "Determination of the refractive index of highly scattering human tissue by optical coherence tomography," Opt. Lett. 20, 2258-2260 (1995).
    • (1995) Opt. Lett , vol.20 , pp. 2258-2260
    • Tearney, G.J.1    Brezinski, M.E.2    Southern, J.F.3    Bouma, B.E.4    Hee, M.R.5    Fujimoto, J.G.6
  • 15
    • 0036816720 scopus 로고    scopus 로고
    • Simultaneous refractive index and thickness measurements of bio tissue by optical coherence tomography
    • X. Wang, C. Zhang, L. Zhang, L. Xue, and J. Tian, "Simultaneous refractive index and thickness measurements of bio tissue by optical coherence tomography," J. Biomed. Opt. 7, 628-632 (2002).
    • (2002) J. Biomed. Opt , vol.7 , pp. 628-632
    • Wang, X.1    Zhang, C.2    Zhang, L.3    Xue, L.4    Tian, J.5
  • 17
    • 0037437366 scopus 로고    scopus 로고
    • Bifocal optical coherence refractometry of turbid media
    • S. A. Alexandrov, A. V. Zvyagin, K. K. Silva, and D. D. Sampson, "Bifocal optical coherence refractometry of turbid media," Opt. Lett. 28, 117-119 (2003).
    • (2003) Opt. Lett , vol.28 , pp. 117-119
    • Alexandrov, S.A.1    Zvyagin, A.V.2    Silva, K.K.3    Sampson, D.D.4
  • 19
    • 36149073052 scopus 로고
    • Comparison of reflection methods for measuring optical constants without polametric analysis, and proposal for new methods based on the Brewster angle
    • S. P. F. Humphreys-Owen, "Comparison of reflection methods for measuring optical constants without polametric analysis, and proposal for new methods based on the Brewster angle," Proceedings of the Physical Society 77, 949-957 (1961).
    • (1961) Proceedings of the Physical Society , vol.77 , pp. 949-957
    • Humphreys-Owen, S.P.F.1
  • 20
    • 0029239888 scopus 로고
    • Refractive index measurement of absorbing and turbid fluids by reflection near the critical angle
    • G. H. Meeten, and A. N. North, "Refractive index measurement of absorbing and turbid fluids by reflection near the critical angle," Measurement Science and Technology 6, 214-221 (1995).
    • (1995) Measurement Science and Technology , vol.6 , pp. 214-221
    • Meeten, G.H.1    North, A.N.2
  • 22
    • 0037109477 scopus 로고    scopus 로고
    • Gradient-index fiber-optic microprobes for minimally invasive in vivo low-coherence interferometry
    • W. A. Reed, M. F. Yan, and M. J. Schnitzer, "Gradient-index fiber-optic microprobes for minimally invasive in vivo low-coherence interferometry," Opt. Lett. 27, 1794-1796 (2002).
    • (2002) Opt. Lett , vol.27 , pp. 1794-1796
    • Reed, W.A.1    Yan, M.F.2    Schnitzer, M.J.3
  • 23
    • 20844433664 scopus 로고    scopus 로고
    • Determination of refractive indices of porcine skin tissues and intralipid at eight wavelengths between 325 and 1557 nm
    • H. Ding, J. Q. Lu, K. M. Jacobs, and X. H. Hu, "Determination of refractive indices of porcine skin tissues and intralipid at eight wavelengths between 325 and 1557 nm," J. Opt. Soc. Am. A 22, 1151-1157 (2005).
    • (2005) J. Opt. Soc. Am. A , vol.22 , pp. 1151-1157
    • Ding, H.1    Lu, J.Q.2    Jacobs, K.M.3    Hu, X.H.4
  • 24
    • 0015604413 scopus 로고
    • Optical constants of water in the 200-nm to 200-um wavelength region
    • G. M. Hale, and M. R. Querry, "Optical constants of water in the 200-nm to 200-um wavelength region," Appl. Opt. 12, 555-563 (1973).
    • (1973) Appl. Opt , vol.12 , pp. 555-563
    • Hale, G.M.1    Querry, M.R.2
  • 25
    • 20644456680 scopus 로고    scopus 로고
    • A portable, low coherence interferometry based instrument for fine needle aspiration biopsy guidance
    • N. V. Iftimia, B. E. Bouma, M. B. Pitman, B. Goldberg, J. Bressner, and G. J. Tearney, "A portable, low coherence interferometry based instrument for fine needle aspiration biopsy guidance," Rev. Sci. Instrum. 76,064301 (2005).
    • (2005) Rev. Sci. Instrum , vol.76 , pp. 064301
    • Iftimia, N.V.1    Bouma, B.E.2    Pitman, M.B.3    Goldberg, B.4    Bressner, J.5    Tearney, G.J.6
  • 26
    • 22744433002 scopus 로고    scopus 로고
    • Determination of reduced scattering coefficient of biological tissue from a needle-like probe
    • M. Johns, C. A. Giller, D. C. German, and H. Liu, "Determination of reduced scattering coefficient of biological tissue from a needle-like probe," Opt. Express 13, 4828-4842 (2005).
    • (2005) Opt. Express , vol.13 , pp. 4828-4842
    • Johns, M.1    Giller, C.A.2    German, D.C.3    Liu, H.4
  • 27
    • 0000691674 scopus 로고    scopus 로고
    • Imaging needle for optical coherence tomography
    • X. Li, C. Chudoba, T. Ko, C. Pitris, and J. G. Fujimoto, "Imaging needle for optical coherence tomography," Opt. Lett. 25, 1520-1522 (2000).
    • (2000) Opt. Lett , vol.25 , pp. 1520-1522
    • Li, X.1    Chudoba, C.2    Ko, T.3    Pitris, C.4    Fujimoto, J.G.5
  • 28
    • 0022256641 scopus 로고
    • Fiber-optic stylet for needle tip localization
    • G. J. Liese, W. Pong, and D. E. Brandt, "Fiber-optic stylet for needle tip localization," Appl. Opt. 24, 3125-3127 (1985).
    • (1985) Appl. Opt , vol.24 , pp. 3125-3127
    • Liese, G.J.1    Pong, W.2    Brandt, D.E.3
  • 29
    • 24744465656 scopus 로고    scopus 로고
    • Use of a multiseparation fiber optic probe for the optical diagnosis of breast cancer
    • C. Zhu, G. M. Palmer, T. M. Breslin, F. Xu, and N. Ramanujam, "Use of a multiseparation fiber optic probe for the optical diagnosis of breast cancer," J. Biomed. Opt. 10, 024032 (2005).
    • (2005) J. Biomed. Opt , vol.10 , pp. 024032
    • Zhu, C.1    Palmer, G.M.2    Breslin, T.M.3    Xu, F.4    Ramanujam, N.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.