Liquid ionization chamber measurements of dose distributions in small 6 MV photon beams
Dasu A, Lofroth P O and Wickman G 1998 Liquid ionization chamber measurements of dose distributions in small 6 MV photon beams Phys. Med. Biol. 43 21-36
Dosimetric characteristics of a new unshielded silicon diode and its application in clinical photon and electron beams
Griessbach I, Lapp M, Bohsung J, Gademann G and Harder D 2005 Dosimetric characteristics of a new unshielded silicon diode and its application in clinical photon and electron beams Med. Phys. 32 3750-4
Investigation of photon beam output factors for conformal radiation therapy-Monte Carlo simulations and measurements
Haryanto F, Fippel M, Laub W, Dohm O and Nusslin F 2002 Investigation of photon beam output factors for conformal radiation therapy-Monte Carlo simulations and measurements Phys. Med. Biol. 47 N133-43
Determination of field size limitations in stereotactic and intensity modulated radiotherapy
Jensen J M, Ihnen E, Eilf K and Kimmig B 2003 Determination of field size limitations in stereotactic and intensity modulated radiotherapy Australas. Phys. Eng. Sci. Med. 26 168-72
Comparison study of MOSFET detectors and diodes for entrance in vivo dosimetry in 18 MV x-ray beams
Jornet N, Carrasco P, Jurado D, Ruiz A, Eudaldo T and Ribas M 2004 Comparison study of MOSFET detectors and diodes for entrance in vivo dosimetry in 18 MV x-ray beams Med. Phys. 31 2534-42
Kron T 1999 The Modern Technology of Radiation Oncology a Compendium for Medical Physicists and Radiation Oncologists vol 1 ed Van Dyk J (Madison, WI: University of Wisconsin Press) p 766
Utilization of custom electron bolus in head and neck radiotherapy
Kudchadker R J, Antolak J A, Morrison W H, Wong P F and Hogstrom K R 2003 Utilization of custom electron bolus in head and neck radiotherapy J. Appl. Clin. Med. Phys. 4 321-33
Entrance and exit dose measurements with semiconductors and thermoluminescent dosimeters: A comparison of methods and in vivo results
Loncol T, Greffe J L, Vynckier S and Scalliet P 1996 Entrance and exit dose measurements with semiconductors and thermoluminescent dosimeters: a comparison of methods and in vivo results Radiother. Oncol. 41 179-87
Feasibility study of entrance in vivo dose measurements with mailed thermoluminescence detectors
Swinnen A, Verstraete J and Huyskens D P 2004 Feasibility study of entrance in vivo dose measurements with mailed thermoluminescence detectors Radiother. Oncol. 73 89-96
Surface buildup dose dependence on photon field delivery technique for IMRT
Yokoyama S, Roberson P L, Litzenberg D W, Moran J M and Fraass B A 2004 Surface buildup dose dependence on photon field delivery technique for IMRT J. Appl. Clin. Med. Phys. 5 71-81