메뉴 건너뛰기




Volumn 27, Issue 1, 2008, Pages 239-245

Automatic correction of Echo-Planar Imaging (EPI) ghosting artifacts in real-time interactive cardiac MRI using sensitivity encoding

Author keywords

Echo misalignment; Echo planar imaging (EPI); Ghosting artifacts; Real time interactive MRI; Sensitivity encoding (SENSE)

Indexed keywords

ARTICLE; ARTIFACT; CALIBRATION; ECHO PLANAR IMAGING; FEASIBILITY STUDY; HUMAN; HUMAN EXPERIMENT; IMAGE RECONSTRUCTION; IN VIVO STUDY; INTERMETHOD COMPARISON; NORMAL HUMAN; NUCLEAR MAGNETIC RESONANCE IMAGING; PHANTOM; PRIORITY JOURNAL; SENSITIVITY AND SPECIFICITY;

EID: 37848998506     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.21214     Document Type: Article
Times cited : (35)

References (19)
  • 1
    • 36149042452 scopus 로고
    • Multi-planar image formation using NMR spin echoes
    • Mansfield P. Multi-planar image formation using NMR spin echoes. J Phys C 1977;10:L55-L58.
    • (1977) J Phys C , vol.10
    • Mansfield, P.1
  • 4
    • 0025256879 scopus 로고
    • Echo-planar imaging with asymmetric gradient modulation and inner-volume excitation
    • Feinberg DA, Turner R, Jakab PD, Kienlin MV. Echo-planar imaging with asymmetric gradient modulation and inner-volume excitation. Magn Reson Med 1990;13:162-169.
    • (1990) Magn Reson Med , vol.13 , pp. 162-169
    • Feinberg, D.A.1    Turner, R.2    Jakab, P.D.3    Kienlin, M.V.4
  • 5
    • 0030802130 scopus 로고    scopus 로고
    • Ghost artifact reduction for echo-planar imaging using image phase correction
    • Buonocore MH, Gao L. Ghost artifact reduction for echo-planar imaging using image phase correction. Magn Reson Med 1997;38:89-100.
    • (1997) Magn Reson Med , vol.38 , pp. 89-100
    • Buonocore, M.H.1    Gao, L.2
  • 6
    • 2942748091 scopus 로고    scopus 로고
    • Removal of EPI Nyquist ghost artifacts with two-dimensional phase correction
    • Chen N-K, Wyrwicz AM. Removal of EPI Nyquist ghost artifacts with two-dimensional phase correction. Magn Reson Med 2004;51:1247-1253.
    • (2004) Magn Reson Med , vol.51 , pp. 1247-1253
    • Chen, N.-K.1    Wyrwicz, A.M.2
  • 8
    • 0036201548 scopus 로고    scopus 로고
    • Herzka DA, Kellman P, Aletras AH, Guttman MA, Multishot EPI-SSFP in the heart. Magn Reson Med 2002;47:655-664.
    • Herzka DA, Kellman P, Aletras AH, Guttman MA, Multishot EPI-SSFP in the heart. Magn Reson Med 2002;47:655-664.
  • 9
    • 33744545028 scopus 로고    scopus 로고
    • Phased array ghost elimination
    • Kellman P, McVeigh ER. Phased array ghost elimination. NMR Biomed 2006;19:352-361.
    • (2006) NMR Biomed , vol.19 , pp. 352-361
    • Kellman, P.1    McVeigh, E.R.2
  • 12
    • 0035032781 scopus 로고    scopus 로고
    • Adaptive sensitivity encoding incorporating temporal filtering (TSENSE)
    • Kellman P, Epstein FH, McVeigh ER. Adaptive sensitivity encoding incorporating temporal filtering (TSENSE). Magn Reson Med 2001;45:846-852.
    • (2001) Magn Reson Med , vol.45 , pp. 846-852
    • Kellman, P.1    Epstein, F.H.2    McVeigh, E.R.3
  • 15
    • 0033061743 scopus 로고    scopus 로고
    • High spatial resolution EPI using an odd number of interleaves
    • Buonocore MH, Zhu DC. High spatial resolution EPI using an odd number of interleaves. Magn Reson Med 1999;41:1199-1205.
    • (1999) Magn Reson Med , vol.41 , pp. 1199-1205
    • Buonocore, M.H.1    Zhu, D.C.2
  • 16
    • 0032186364 scopus 로고    scopus 로고
    • Image-based reduction of artifacts in multishot echoplanar imaging
    • Hennel F. Image-based reduction of artifacts in multishot echoplanar imaging. J Magn Reson 1998;134:206-213.
    • (1998) J Magn Reson , vol.134 , pp. 206-213
    • Hennel, F.1
  • 17
    • 0000114910 scopus 로고
    • Gradient-echo shifting in fast MRI techniques for correction of field inhomogeneity errors and chemical shift
    • Feinberg DA, Oshio K. Gradient-echo shifting in fast MRI techniques for correction of field inhomogeneity errors and chemical shift. J Magn Reson 1992;97:177-183.
    • (1992) J Magn Reson , vol.97 , pp. 177-183
    • Feinberg, D.A.1    Oshio, K.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.