메뉴 건너뛰기




Volumn 51, Issue 4, 2004, Pages 655-660

Real-Time Cardiac MRI at 3 Tesla

Author keywords

Cardiac imaging; High field; Real time MRI; Spectral spatial excitation; Spirals

Indexed keywords

BLOOD; EFFICIENCY; HEART; IMAGE ENHANCEMENT; IMAGE QUALITY;

EID: 1842533962     PISSN: 07403194     EISSN: None     Source Type: Journal    
DOI: 10.1002/mrm.20053     Document Type: Article
Times cited : (88)

References (21)
  • 4
    • 0034883846 scopus 로고    scopus 로고
    • Rapid evaluation of left ventricular volume and mass without breath-holding using real-time interactive cardiac magnetic resonance imaging system
    • Kaji S, Yang PC, Kerr AB, Tang WH, Meyer CH, Macovski A, Pauly JM, Nishimura DG, Hu BS. Rapid evaluation of left ventricular volume and mass without breath-holding using real-time interactive cardiac magnetic resonance imaging system. J Am Coll Cardiol 2001;38:527-533.
    • (2001) J Am Coll Cardiol , vol.38 , pp. 527-533
    • Kaji, S.1    Yang, P.C.2    Kerr, A.B.3    Tang, W.H.4    Meyer, C.H.5    Macovski, A.6    Pauly, J.M.7    Nishimura, D.G.8    Hu, B.S.9
  • 10
    • 0031083035 scopus 로고    scopus 로고
    • 1 field distribution and intrinsic signal-to-noise in cardiac MRI as a function of static magnetic field
    • 1 field distribution and intrinsic signal-to-noise in cardiac MRI as a function of static magnetic field. J Magn Reson 1997;125:72-83.
    • (1997) J Magn Reson , vol.125 , pp. 72-83
    • Singerman, R.W.1    Denison, T.J.2    Wen, H.3    Balaban, R.S.4
  • 12
    • 0031877407 scopus 로고    scopus 로고
    • Simultaneous highly selective MR water and fat imaging using a simple new type of spectral-spatial excitation
    • Schick F. Simultaneous highly selective MR water and fat imaging using a simple new type of spectral-spatial excitation. Magn Reson Med 1998;20:194-202.
    • (1998) Magn Reson Med , vol.20 , pp. 194-202
    • Schick, F.1
  • 13
    • 0034005490 scopus 로고    scopus 로고
    • Design of improved spectral-spatial pulses for routine clinical use
    • Zur Y. Design of improved spectral-spatial pulses for routine clinical use. Magn Reson Med 2000;43:410-420.
    • (2000) Magn Reson Med , vol.43 , pp. 410-420
    • Zur, Y.1
  • 16
  • 17
    • 0029095343 scopus 로고
    • Optimized gradient waveforms for spiral scanning
    • King KF, Foo TKF, Crawford CR. Optimized gradient waveforms for spiral scanning. Magn Reson Med 1995;34:156-160.
    • (1995) Magn Reson Med , vol.34 , pp. 156-160
    • King, K.F.1    Foo, T.K.F.2    Crawford, C.R.3
  • 20
    • 0022187595 scopus 로고
    • A fast sinc function gridding algorithm for Fourier inversion in computer tomography
    • O'Sullivan JD. A fast sinc function gridding algorithm for Fourier inversion in computer tomography. IEEE Trans Med Imag 1985;4:200-207.
    • (1985) IEEE Trans Med Imag , vol.4 , pp. 200-207
    • O'Sullivan, J.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.