Volumn 35, Issue 1, 2008, Pages 25-31

Correction factors for low perturbation in vivo diodes used in the determination of entrance doses in high energy photon beams

Author keywords

Correction factor; Diodes; Dose perturbation; Entrance dose; In vivo dosimetry

Indexed keywords

DOSIMETRY; PARTICLE BEAMS; PHOTOELECTRONS; PHOTONS;

EID: 37549064756     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2818729     Document Type: Article
Times cited : (6)

References (18)
  • 1
    • 0010990601 scopus 로고
    • Dosimetric precision requirements in radiation therapy
    • 0349-652X
    • A. Brahmë, " Dosimetric precision requirements in radiation therapy., " Acta Radiol. Oncol. 23, 379-391 (1984). 0349-652X
    • (1984) Acta Radiol. Oncol. , vol.23 , pp. 379-391
    • Brahmë, A.1
  • 2
    • 0023202277 scopus 로고
    • What degree of accuracy is required and can be achieved in photon and neutron therapy?
    • 0167-8140
    • B. J. Mijnheer, J. J. Battermann, and A. Wambersie, " What degree of accuracy is required and can be achieved in photon and neutron therapy? " Radiother. Oncol. 8, 237-252 (1987). 0167-8140
    • (1987) Radiother. Oncol. , vol.8 , pp. 237-252
    • Mijnheer, B.J.1    Battermann, J.J.2    Wambersie, A.3
  • 4
    • 0033556681 scopus 로고    scopus 로고
    • In vivo dosimetry during external photon beam radiotherapy
    • 0360-3016
    • M. Essers and B. Mijnheer, " In vivo dosimetry during external photon beam radiotherapy., " Int. J. Radiat. Oncol. Biol. Phys. 43, 245-259 (1999). 0360-3016
    • (1999) Int. J. Radiat. Oncol. Biol. Phys. , vol.43 , pp. 245-259
    • Essers, M.1    Mijnheer, B.2
  • 7
    • 85027217682 scopus 로고    scopus 로고
    • IPEM 1999 Physics Aspects of Quality Control in Radiotherapy, Report 81, Institute of Physics and Engineering in Medicine, New York
    • IPEM 1999 Physics Aspects of Quality Control in Radiotherapy, Report 81, Institute of Physics and Engineering in Medicine, New York, 1999.
    • (1999)
  • 8
    • 0023870307 scopus 로고
    • Characteristics of silicon diodes as patient dosimeters in external radiation therapy
    • 0167-8140 10.1016/0167-8140(88)90011-4
    • B. Nilsson, B. I. Ruden, and B. Sorcini, " Characteristics of silicon diodes as patient dosimeters in external radiation therapy., " Radiother. Oncol. 0167-8140 10.1016/0167-8140(88)90011-4 11, 279-288 (1988).
    • (1988) Radiother. Oncol. , vol.11 , pp. 279-288
    • Nilsson, B.1    Ruden, B.I.2    Sorcini, B.3
  • 9
    • 0030887102 scopus 로고    scopus 로고
    • Dose perturbations due to in vivo dosimetry with diodes
    • 0167-8140 10.1016/S0167-8140(96)01872-5
    • R. Alecu, J. Feldmeier, and M. Alecu, " Dose perturbations due to in vivo dosimetry with diodes., " Radiother. Oncol. 0167-8140 10.1016/S0167-8140(96)01872-5 42, 289-291 (1997).
    • (1997) Radiother. Oncol. , vol.42 , pp. 289-291
    • Alecu, R.1    Feldmeier, J.2    Alecu, M.3
  • 10
    • 0029789269 scopus 로고    scopus 로고
    • Quantitative assessment of beam perturbations caused by silicon diodes used for in vivo dosimetry
    • 0360-3016
    • A. Sen, E. I. Parsai, S. W. McNeeley, M. S. Ayyangar, and K. M. Ayyangar, " Quantitative assessment of beam perturbations caused by silicon diodes used for in vivo dosimetry., " Int. J. Radiat. Oncol. Biol. Phys. 36, 205-211 (1996). 0360-3016
    • (1996) Int. J. Radiat. Oncol. Biol. Phys. , vol.36 , pp. 205-211
    • Sen, A.1    Parsai, E.I.2    McNeeley, S.W.3    Ayyangar, M.S.4    Ayyangar, K.M.5
  • 11
    • 0026447925 scopus 로고
    • In vivo dosimetry during pelvic treatment
    • 0167-8140 10.1016/0167-8140(92)90017-O
    • S. Heukelom, J. H. Lanson, and B. J. Mijnheer, " In vivo dosimetry during pelvic treatment., " Radiother. Oncol. 0167-8140 10.1016/0167-8140(92)90017-O 25, 111-120 (1992).
    • (1992) Radiother. Oncol. , vol.25 , pp. 111-120
    • Heukelom, S.1    Lanson, J.H.2    Mijnheer, B.J.3
  • 12
    • 0033010139 scopus 로고    scopus 로고
    • Build-up modification of commercial diodes for entrance dose measurements in higher energy beams
    • 0167-8140 10.1016/S0167-8140(99)00058-4
    • D. Georg, B. De Ost, P. P. Hoornaert, J. Van Dam, M. Van Dycke, and D. Huyskens, " Build-up modification of commercial diodes for entrance dose measurements in higher energy beams., " Radiother. Oncol. 0167-8140 10.1016/S0167-8140(99)00058-4 51, 249-256 (1999).
    • (1999) Radiother. Oncol. , vol.51 , pp. 249-256
    • Georg, D.1    De Ost, B.2    Hoornaert, P.P.3    Van Dam, J.4    Van Dycke, M.5    Huyskens, D.6
  • 13
    • 1942420364 scopus 로고    scopus 로고
    • Dose rate and SDD dependence of commercially available diode detectors
    • 0094-2405 10.1118/1.1650563
    • A. S. Saini and T. C. Zhu, " Dose rate and SDD dependence of commercially available diode detectors., " Med. Phys. 0094-2405 10.1118/1.1650563 31, 914-924 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 914-924
    • Saini, A.S.1    Zhu, T.C.2
  • 14
    • 4644311758 scopus 로고    scopus 로고
    • Comparison study of MOSFET detectors and diodes for entrance in vivo dosimetry in 18 MV x-ray beams
    • 0094-2405 10.1118/1.1785452
    • N. Jornet, P. Carrasco, D. Jurado, A. Ruiz, T. Eudaldo, and M. Ribas, " Comparison study of MOSFET detectors and diodes for entrance in vivo dosimetry in 18 MV x-ray beams., " Med. Phys. 0094-2405 10.1118/1.1785452 31, 2534-2542 (2004).
    • (2004) Med. Phys. , vol.31 , pp. 2534-2542
    • Jornet, N.1    Carrasco, P.2    Jurado, D.3    Ruiz, A.4    Eudaldo, T.5    Ribas, M.6
  • 15
    • 0030292867 scopus 로고    scopus 로고
    • Entrance and exit dose measurements with semiconductors and thermoluminescent dosemeters: A comparison of methods and in vivo results
    • 0167-8140 10.1016/S0167-8140(96)01826-9
    • T. Loncol, J. L. Greffe, S. Vynckier, and P. Scalliet, " Entrance and exit dose measurements with semiconductors and thermoluminescent dosemeters: A comparison of methods and in vivo results., " Radiother. Oncol. 0167-8140 10.1016/S0167-8140(96)01826-9 41, 179-187 (1996).
    • (1996) Radiother. Oncol. , vol.41 , pp. 179-187
    • Loncol, T.1    Greffe, J.L.2    Vynckier, S.3    Scalliet, P.4
  • 16
    • 0028857468 scopus 로고
    • The use of electronic portal imaging device for exit dosimetry and quality control measurements
    • 0360-3016
    • M. C. Kirby and P. C. Williams, " The use of electronic portal imaging device for exit dosimetry and quality control measurements., " Int. J. Radiat. Oncol. Biol. Phys. 31, 593-603 (1995). 0360-3016
    • (1995) Int. J. Radiat. Oncol. Biol. Phys. , vol.31 , pp. 593-603
    • Kirby, M.C.1    Williams, P.C.2
  • 17
    • 33747611733 scopus 로고    scopus 로고
    • An intercomparison of 11 amorphous silicon EPIDs of the same type: Implications for portal dosimetry
    • 0031-9155 10.1088/0031-9155/51/17/005
    • P. Winkler and D. Georg, " An intercomparison of 11 amorphous silicon EPIDs of the same type: implications for portal dosimetry., " Phys. Med. Biol. 0031-9155 10.1088/0031-9155/51/17/005 51, 4189-4200 (2006).
    • (2006) Phys. Med. Biol. , vol.51 , pp. 4189-4200
    • Winkler, P.1    Georg, D.2
  • 18
    • 85027223035 scopus 로고    scopus 로고
    • Scanditronix technical specifications booklet
    • Scanditronix technical specifications booklet, http://www.qados.co.uk/ invivo_dosimetry.htm.