Volumn 13, Issue 1, 2008, Pages 24-32

Strategies to Maintain Sample Integrity Using a Liquid-Filled Automated Liquid-Handling System with Fixed Pipetting Tips

Author keywords

ALH; automated liquid handler; dilution effect; dual dye; fixed tip; gravimetric; liquid handling parameters; photometric; sample dilution; Tecan

Indexed keywords

DILUTION; LIQUIDS; MATERIALS HANDLING; OPTIMIZATION;

EID: 37549032430     PISSN: 15355535     EISSN: 15402452     Source Type: Journal    
DOI: 10.1016/j.jala.2007.10.007     Document Type: Article
Times cited : (15)

References (9)
  • 1
    • 13544275671 scopus 로고    scopus 로고
    • Validation of a semi-automated human hepatocyte assay for the determination and prediction of intrinsic clearance in discovery
    • Reddy A., Heimbach T., Freiwald S., Smith D., Winters R., Michael S., Surendran N., and Cai H. Validation of a semi-automated human hepatocyte assay for the determination and prediction of intrinsic clearance in discovery. J. Pharm. Biomed. Anal. 37 (2005) 319-326
    • (2005) J. Pharm. Biomed. Anal. , vol.37 , pp. 319-326
    • Reddy, A.1    Heimbach, T.2    Freiwald, S.3    Smith, D.4    Winters, R.5    Michael, S.6    Surendran, N.7    Cai, H.8
  • 2
    • 0036001224 scopus 로고    scopus 로고
    • High-speed gradient parallel liquid chromatography/tandem mass spectrometry with fully automated sample preparation for bioanalysis: 30 seconds per sample from plasma
    • Deng Y., Wu J.T., Lloyd T.L., Chi C.L., Olah T.V., and Unger S.E. High-speed gradient parallel liquid chromatography/tandem mass spectrometry with fully automated sample preparation for bioanalysis: 30 seconds per sample from plasma. Rapid Commun. Mass Spectrom. 16 11 (2002) 1116-1123
    • (2002) Rapid Commun. Mass Spectrom. , vol.16 , Issue.11 , pp. 1116-1123
    • Deng, Y.1    Wu, J.T.2    Lloyd, T.L.3    Chi, C.L.4    Olah, T.V.5    Unger, S.E.6
  • 3
    • 2342532396 scopus 로고    scopus 로고
    • Automated calibration of TECAN genesis liquid handling workstation utilizing an online balance and density meter
    • Xie I.H., Wang M.H., Carpenter R., and Wu H.Y. Automated calibration of TECAN genesis liquid handling workstation utilizing an online balance and density meter. Assay Drug Devel. Technol. 2 1 (2004) 71-80
    • (2004) Assay Drug Devel. Technol. , vol.2 , Issue.1 , pp. 71-80
    • Xie, I.H.1    Wang, M.H.2    Carpenter, R.3    Wu, H.Y.4
  • 4
    • 1542617944 scopus 로고    scopus 로고
    • Serum peptide profiling by magnetic particle-assisted, automated sample processing and MALDI-TOF mass spectrometry
    • Villanueva J., Philip J., Entenberg D., Chaparro C.A., Tanwar M.K., Holland E.C., and Tempst P. Serum peptide profiling by magnetic particle-assisted, automated sample processing and MALDI-TOF mass spectrometry. Anal. Chem. 76 6 (2004) 1560-1570
    • (2004) Anal. Chem. , vol.76 , Issue.6 , pp. 1560-1570
    • Villanueva, J.1    Philip, J.2    Entenberg, D.3    Chaparro, C.A.4    Tanwar, M.K.5    Holland, E.C.6    Tempst, P.7
  • 5
    • 33645945895 scopus 로고    scopus 로고
    • The use of a dual dye photometric calibration method to identify possible sample dilution from an automated multichannel liquid-handling system
    • Dong H., Ouyang Z., Liu J., and Jemal M. The use of a dual dye photometric calibration method to identify possible sample dilution from an automated multichannel liquid-handling system. J. Assoc. Lab. Autom. 11 2 (2006) 60-64
    • (2006) J. Assoc. Lab. Autom. , vol.11 , Issue.2 , pp. 60-64
    • Dong, H.1    Ouyang, Z.2    Liu, J.3    Jemal, M.4
  • 6
    • 0034638155 scopus 로고    scopus 로고
    • An automated method of sample preparation of biofluids using pierceable caps to eliminate the uncapping of the sample tubes during sample transfer
    • Teitz D.S., Khan S., Powell M.L., and Jemal M. An automated method of sample preparation of biofluids using pierceable caps to eliminate the uncapping of the sample tubes during sample transfer. J. Biochem. Biophys. Methods 45 2 (2000) 193-204
    • (2000) J. Biochem. Biophys. Methods , vol.45 , Issue.2 , pp. 193-204
    • Teitz, D.S.1    Khan, S.2    Powell, M.L.3    Jemal, M.4
  • 7
    • 37549071135 scopus 로고    scopus 로고
    • Curtis, R. H. Photometric Calibration of Liquid Volumes, (U.S. Patent No. 6, 741,365), May 25, 2004.
  • 8
    • 37549067054 scopus 로고    scopus 로고
    • Optimizing liquid handling parameters to minimize possible sample dilution with washable tips. Tecan Technical Note 395854 v1, November 2006.
  • 9
    • 37549006469 scopus 로고    scopus 로고
    • Gabardy, R. of Immunalysis Corporation, Pomona, CA, personal communication to Porter, G, May 2, 2007.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.