Volumn 11, Issue 2, 2006, Pages 60-64

The Use of a Dual Dye Photometric Calibration Method to Identify Possible Sample Dilution from an Automated Multichannel Liquid-handling System

Author keywords

ALH; automated liquid handling system; dual dye approach; gravimetric approach; MVS; Tecan Genesis RSP; Tomtec Quadra

Indexed keywords

ASSAYS; CALIBRATION; DYES; GRAVIMETRIC ANALYSIS; OPTIMIZATION;

EID: 33645945895     PISSN: 22110682     EISSN: 15402452     Source Type: Journal    
DOI: 10.1016/j.jala.2006.02.005     Document Type: Article
Times cited : (20)

References (12)
  • 1
    • 16844377080 scopus 로고    scopus 로고
    • Kalibbrierung des Mikroliterpipetten
    • Romaguera A. Kalibbrierung des Mikroliterpipetten. GIT Labor-Fachzeitschrift 2002, 4, 498–500.
    • (2002) GIT Labor-Fachzeitschrift , vol.4 , pp. 498-500
    • Romaguera, A.1
  • 3
    • 16844378996 scopus 로고    scopus 로고
    • Comparison of absorbance and fluorescence methods for determining liquid dispensing precision
    • Peterson J. Nguyen J. Comparison of absorbance and fluorescence methods for determining liquid dispensing precision. J. Am. Lab. Autom. 2005, 10, 82–87.
    • (2005) J. Am. Lab. Autom. , vol.10 , pp. 82-87
    • Peterson, J.1    Nguyen, J.2
  • 6
    • 13844300660 scopus 로고    scopus 로고
    • Performance verification of small volume mechanical action pipettes
    • Curtis R. H. Performance verification of small volume mechanical action pipettes. Cal. Lab. 1996, 3, 23–28.
    • (1996) Cal. Lab. , vol.3 , pp. 23-28
    • Curtis, R.H.1
  • 8
    • 13844296598 scopus 로고    scopus 로고
    • Multichannel verification system (MVS): A dual dye ratiometric photometry system for performance verification of multichannel liquid delivery devices
    • Bradshaw J. T. Knaide T. Rogers A. Curtis R. Multichannel verification system (MVS): A dual dye ratiometric photometry system for performance verification of multichannel liquid delivery devices. J. Am. Lab. Autom. 2005, 10, 35–42.
    • (2005) J. Am. Lab. Autom. , vol.10 , pp. 35-42
    • Bradshaw, J.T.1    Knaide, T.2    Rogers, A.3    Curtis, R.4
  • 10
    • 33645949154 scopus 로고
    • Sampling with air-piston pipettes-a critical study
    • Sternberg J. C. Sampling with air-piston pipettes-a critical study. Clin. Chem. 1975, 21(7), 1037.
    • (1975) Clin. Chem. , vol.21 , Issue.7 , pp. 1037
    • Sternberg, J.C.1
  • 11
    • 0015895058 scopus 로고
    • Errors inherent in the use of piston activated pipettes
    • Ellis K. J. Errors inherent in the use of piston activated pipettes. Anal. Biochem. 1973, 55(2), 609–614.
    • (1973) Anal. Biochem. , vol.55 , Issue.2 , pp. 609-614
    • Ellis, K.J.1
  • 12
    • 0029756604 scopus 로고    scopus 로고
    • Factors influencing the measuring accuracy of piston pipettes with air interface
    • Lochner K. H. Ballweg T. Fahrenkrog H. H. Factors influencing the measuring accuracy of piston pipettes with air interface. J. Lab. Med. 1996, 20(7 / 8), 430–440.
    • (1996) J. Lab. Med. , vol.20 , Issue.7-8 , pp. 430-440
    • Lochner, K.H.1    Ballweg, T.2    Fahrenkrog, H.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.