메뉴 건너뛰기




Volumn 58, Issue 6, 2007, Pages 1171-1181

Parallel imaging reconstruction for arbitrary trajectories using k-space sparse matrices (kSPA)

Author keywords

Functional imaging; kSPA; Magnetic resonance imaging; Massive parallel imaging; Parallel imaging; Sparse approximate inverse; Sparse matrix

Indexed keywords

IMAGE RECONSTRUCTION; INVERSE PROBLEMS; ITERATIVE METHODS; MAGNETIC RESONANCE IMAGING; MATRIX ALGEBRA; TENSORS;

EID: 36849042021     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.21334     Document Type: Article
Times cited : (45)

References (40)
  • 1
    • 38249035106 scopus 로고
    • An algorithm for NMR imaging reconstruction based on multiple RF receiver coils
    • Carlson JW. An algorithm for NMR imaging reconstruction based on multiple RF receiver coils. J Magn Reson 1987;74:376-380.
    • (1987) J Magn Reson , vol.74 , pp. 376-380
    • Carlson, J.W.1
  • 2
    • 0023870882 scopus 로고
    • Fast MRI data acquisition using multiple detectors
    • Hutchinson M, Raff U. Fast MRI data acquisition using multiple detectors. Magn Reson Med 1988;8:87-91.
    • (1988) Magn Reson Med , vol.8 , pp. 87-91
    • Hutchinson, M.1    Raff, U.2
  • 4
    • 0027173207 scopus 로고
    • Imaging time reduction through multiple receiver coil data acquisition and image reconstruction
    • Carlson JW, Minemura T. Imaging time reduction through multiple receiver coil data acquisition and image reconstruction. Magn Reson Med 1993;29:681-687.
    • (1993) Magn Reson Med , vol.29 , pp. 681-687
    • Carlson, J.W.1    Minemura, T.2
  • 6
    • 0034794323 scopus 로고    scopus 로고
    • Advances in sensitivity encoding with arbitrary k-space trajectories
    • Pruessmann KP, Weiger M, Bornert P, Boesiger P. Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med 2001;46:638-651.
    • (2001) Magn Reson Med , vol.46 , pp. 638-651
    • Pruessmann, K.P.1    Weiger, M.2    Bornert, P.3    Boesiger, P.4
  • 8
    • 0030982409 scopus 로고    scopus 로고
    • Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
    • Sodickson DK, Manning WJ. Simultaneous acquisition of spatial harmonics (SMASH): fast imaging with radiofrequency coil arrays. Magn Reson Med 1997;38:591-603.
    • (1997) Magn Reson Med , vol.38 , pp. 591-603
    • Sodickson, D.K.1    Manning, W.J.2
  • 12
    • 19544369296 scopus 로고    scopus 로고
    • Parallel magnetic resonance imaging with adaptive radius in k-space (PARS): Constrained image reconstruction using k-space locality in radiofrequency coil encoded data
    • Yeh EN, McKenzie CA, Ohliger MA, Sodickson DK. Parallel magnetic resonance imaging with adaptive radius in k-space (PARS): constrained image reconstruction using k-space locality in radiofrequency coil encoded data. Magn Reson Med 2005;53:1383-1392.
    • (2005) Magn Reson Med , vol.53 , pp. 1383-1392
    • Yeh, E.N.1    McKenzie, C.A.2    Ohliger, M.A.3    Sodickson, D.K.4
  • 15
    • 0000135303 scopus 로고
    • Method of conjugate gradients for solving linear systems
    • Hestenes MR. Stiefel EL. Method of conjugate gradients for solving linear systems. J Res Natl Bur Standards 1952:409-435.
    • (1952) J Res Natl Bur Standards , pp. 409-435
    • Hestenes, M.R.1    Stiefel, E.L.2
  • 16
    • 33644804967 scopus 로고    scopus 로고
    • Auto-calibrated parallel spiral imaging
    • Heberlein K, Hu X. Auto-calibrated parallel spiral imaging. Magn Reson Med 2006;55:619-625.
    • (2006) Magn Reson Med , vol.55 , pp. 619-625
    • Heberlein, K.1    Hu, X.2
  • 18
    • 0027263961 scopus 로고
    • Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical model
    • Ogawa S, Menon RS, Tank DW, Kim SG, Merkle H, Ellermann JM, Ugurbil K. Functional brain mapping by blood oxygenation level-dependent contrast magnetic resonance imaging. A comparison of signal characteristics with a biophysical model. Biophys J 1993;64:803-812.
    • (1993) Biophys J , vol.64 , pp. 803-812
    • Ogawa, S.1    Menon, R.S.2    Tank, D.W.3    Kim, S.G.4    Merkle, H.5    Ellermann, J.M.6    Ugurbil, K.7
  • 19
    • 0025630001 scopus 로고
    • Brain magnetic resonance imaging with contrast dependent on blood oxygenation
    • Ogawa S, Lee TM, Kay AR, Tank DW. Brain magnetic resonance imaging with contrast dependent on blood oxygenation. Proc Natl Acad Sci USA 1990;87:9868-9872.
    • (1990) Proc Natl Acad Sci USA , vol.87 , pp. 9868-9872
    • Ogawa, S.1    Lee, T.M.2    Kay, A.R.3    Tank, D.W.4
  • 22
    • 0030049425 scopus 로고    scopus 로고
    • Clinical outcome in ischemic stroke predicted by early diffusion-weighted and perfusion magnetic resonance imaging: A preliminary analysis
    • Warach S, Dashe JF, Edelman RR. Clinical outcome in ischemic stroke predicted by early diffusion-weighted and perfusion magnetic resonance imaging: a preliminary analysis. J Cereb Blood Flow Metab 1996;16:53-59.
    • (1996) J Cereb Blood Flow Metab , vol.16 , pp. 53-59
    • Warach, S.1    Dashe, J.F.2    Edelman, R.R.3
  • 24
    • 0028154030 scopus 로고
    • MR diffusion tensor spectroscopy and imaging
    • Basser PJ, Mattiello J, LeBihan D. MR diffusion tensor spectroscopy and imaging. Biophys J 1994;66:259-267.
    • (1994) Biophys J , vol.66 , pp. 259-267
    • Basser, P.J.1    Mattiello, J.2    LeBihan, D.3
  • 26
    • 10044240735 scopus 로고    scopus 로고
    • Self-navigated interleaved spiral (SNAILS): Application to high-resolution diffusion tensor imaging
    • Liu C, Bammer R, Kim DH, Moseley ME. Self-navigated interleaved spiral (SNAILS): application to high-resolution diffusion tensor imaging. Magn Reson Med 2004;52:1388-1396.
    • (2004) Magn Reson Med , vol.52 , pp. 1388-1396
    • Liu, C.1    Bammer, R.2    Kim, D.H.3    Moseley, M.E.4
  • 27
    • 28444494016 scopus 로고    scopus 로고
    • Simultaneous phase correction and SENSE reconstruction for navigated multi-shot DWI with non-Cartesian k-space sampling
    • Liu C, Moseley ME, Bammer R. Simultaneous phase correction and SENSE reconstruction for navigated multi-shot DWI with non-Cartesian k-space sampling. Magn Reson Med 2005;54:1412-1422.
    • (2005) Magn Reson Med , vol.54 , pp. 1412-1422
    • Liu, C.1    Moseley, M.E.2    Bammer, R.3
  • 28
    • 0026219520 scopus 로고
    • Selection of a convolution function for Fourier inversion using gridding
    • Jackson JI, Meyer CH, Nishimura DG, A M. Selection of a convolution function for Fourier inversion using gridding. IEEE Trans Med Imaging 1991;10:473-478.
    • (1991) IEEE Trans Med Imaging , vol.10 , pp. 473-478
    • Jackson, J.I.1    Meyer, C.H.2    Nishimura, D.A.M.3
  • 29
    • 0039943513 scopus 로고
    • An algorithm for sparse linear equations and sparse least squares
    • Paige CC and Saunders MA. LSQR: An algorithm for sparse linear equations and sparse least squares, ACM Trans of Math Software 1982;8(1):43-71.
    • (1982) ACM Trans of Math Software , vol.8 , Issue.1 , pp. 43-71
    • Paige, C.C.1    Saunders, M.L.2
  • 30
    • 0004675411 scopus 로고    scopus 로고
    • A sparse approximate inverse preconditioner for the conjugate gradient method
    • Benzi M, Meyer C, Tuma M. A sparse approximate inverse preconditioner for the conjugate gradient method. Siam J Sci Comput 1996;17:1135.
    • (1996) Siam J Sci Comput , vol.17 , pp. 1135
    • Benzi, M.1    Meyer, C.2    Tuma, M.3
  • 31
    • 0000131670 scopus 로고
    • Iterative solution of large sparse linear systems arising in certain multidimensional approximation problems
    • Benson M, Frederickson P. Iterative solution of large sparse linear systems arising in certain multidimensional approximation problems. Utilitas Math 1982;22:127-140.
    • (1982) Utilitas Math , vol.22 , pp. 127-140
    • Benson, M.1    Frederickson, P.2
  • 34
    • 0036187917 scopus 로고    scopus 로고
    • Combination of signals from array coils using image-based estimation of coil sensitivity profiles
    • Bydder M, Larkman DJ, Hajnal JV. Combination of signals from array coils using image-based estimation of coil sensitivity profiles. Magn Reson Med 2002;47:539-548.
    • (2002) Magn Reson Med , vol.47 , pp. 539-548
    • Bydder, M.1    Larkman, D.J.2    Hajnal, J.V.3
  • 36
    • 0037904043 scopus 로고    scopus 로고
    • A wavelet-based approximation of surface coil sensitivity profiles for correction of image intensity inhomogeneity and parallel imaging reconstruction
    • Lin FH, Chen YJ, Belliveau JW, Wald LL. A wavelet-based approximation of surface coil sensitivity profiles for correction of image intensity inhomogeneity and parallel imaging reconstruction. Hum Brain Mapp 2003;19:96-111.
    • (2003) Hum Brain Mapp , vol.19 , pp. 96-111
    • Lin, F.H.1    Chen, Y.J.2    Belliveau, J.W.3    Wald, L.L.4
  • 38
    • 34250516079 scopus 로고
    • Smoothing by spline functions
    • Reinsch C. Smoothing by spline functions. Numer Math 1967;10:177-183.
    • (1967) Numer Math , vol.10 , pp. 177-183
    • Reinsch, C.1
  • 39
    • 0032818760 scopus 로고    scopus 로고
    • Simple analytic spiral k-space algorithm
    • Glover GH. Simple analytic spiral k-space algorithm. Magn Reson Med 1999;42:412-415.
    • (1999) Magn Reson Med , vol.42 , pp. 412-415
    • Glover, G.H.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.