메뉴 건너뛰기




Volumn 17, Issue 3, 2007, Pages 119-130

Zirconia heads in perspective: A survey of zirconia outcomes in total hip replacement

Author keywords

Degradation; Hip replacement; Prosthesis; Wear debris; Zirconia

Indexed keywords

ALUMINUM OXIDE; POLYETHYLENE; ULTRA HIGH MOLECULAR WEIGHT POLYETHYLENE; ZIRCONIUM OXIDE;

EID: 36549036199     PISSN: 11207000     EISSN: None     Source Type: Journal    
DOI: 10.5301/HIP.2008.2496     Document Type: Review
Times cited : (20)

References (75)
  • 2
    • 17644420953 scopus 로고    scopus 로고
    • Ceramics orthopedics - 30 years of evolution and experience
    • Rieker C, Oberholzer S, Wyss U, eds, Bern: Hans Huber
    • Rieger W. Ceramics orthopedics - 30 years of evolution and experience. In: Rieker C, Oberholzer S, Wyss U, eds. World Tribology Forum in Arthroplasty. Bern: Hans Huber 2001; 283-94.
    • (2001) World Tribology Forum in Arthroplasty , pp. 283-294
    • Rieger, W.1
  • 4
    • 85036967298 scopus 로고    scopus 로고
    • accessed 1 August 2006
    • http://www.bioproimplants.com/documents/PSL.pdf (accessed 1 August 2006).
  • 5
    • 0342414959 scopus 로고    scopus 로고
    • Arthroplasty of the thumb carpometacarpal joint
    • Calandruccio JH, Jobe MT. Arthroplasty of the thumb carpometacarpal joint. Semin Arthroplasty 1997; 82: 135-47.
    • (1997) Semin Arthroplasty , vol.82 , pp. 135-147
    • Calandruccio, J.H.1    Jobe, M.T.2
  • 7
    • 0036516450 scopus 로고    scopus 로고
    • Three-dimensional computerized stress analysis of commercially pure titanium and yttrium-partially stabilized zirconia implants
    • Kohal RJ, Papavasiliou G, Kamposiora P, Tripodakis A, Strub JR. Three-dimensional computerized stress analysis of commercially pure titanium and yttrium-partially stabilized zirconia implants. Int J Prosthodont 2002; 15: 189-94.
    • (2002) Int J Prosthodont , vol.15 , pp. 189-194
    • Kohal, R.J.1    Papavasiliou, G.2    Kamposiora, P.3    Tripodakis, A.4    Strub, J.R.5
  • 8
    • 0033301391 scopus 로고    scopus 로고
    • Zirconia-TZP and alumina: Advanced technologies for the manufacture of single crowns
    • Luthard RG, Sandkul O, Reitz B. Zirconia-TZP and alumina: advanced technologies for the manufacture of single crowns. Eur J Prosthodont Restor Dent 1999; 7: 113-9.
    • (1999) Eur J Prosthodont Restor Dent , vol.7 , pp. 113-119
    • Luthard, R.G.1    Sandkul, O.2    Reitz, B.3
  • 9
    • 0346255220 scopus 로고    scopus 로고
    • A new knee prosthesis with bisurface femoral component made of zirconia-ceramic
    • Nakamura T, Oonishi E, Yasuda T, Nakagawa Y. A new knee prosthesis with bisurface femoral component made of zirconia-ceramic. Key Eng Mater 2004; 254-6: 607-10.
    • (2004) Key Eng Mater
    • Nakamura, T.1    Oonishi, E.2    Yasuda, T.3    Nakagawa, Y.4
  • 11
    • 36549023215 scopus 로고    scopus 로고
    • ZrO2-TZP in dentistry. Material, properties and applications
    • Weber W, Rieger W. ZrO2-TZP in dentistry. Material, properties and applications. Key Eng Mater 2000; 192-5: 841-4.
    • (2000) Key Eng Mater
    • Weber, W.1    Rieger, W.2
  • 12
    • 85036978399 scopus 로고    scopus 로고
    • Ministére de l'emploi et de la solidarité. Décision du 10 aôut 2001 portant sur la suspension d'utilisation de certaines tetees de prothése de hanche en céramique de zircone. Journal Officiel de la République Française, Textes Generaux 2001; 200: 13884.
    • Ministére de l'emploi et de la solidarité. Décision du 10 aôut 2001 portant sur la suspension d'utilisation de certaines tetees de prothése de hanche en céramique de zircone. Journal Officiel de la République Française, Textes Generaux 2001; 200: 13884.
  • 14
    • 85037004568 scopus 로고    scopus 로고
    • American Society for Testing and Materials. ASTM F-1873: Standard specification for high-purity dense yttria tetragonal zirconium oxide polycrystal (Y-TZP) for surgical implant applications. ASTM International 1998.
    • American Society for Testing and Materials. ASTM F-1873: Standard specification for high-purity dense yttria tetragonal zirconium oxide polycrystal (Y-TZP) for surgical implant applications. ASTM International 1998.
  • 15
    • 85036962451 scopus 로고    scopus 로고
    • American Society for Testing and Materials. ASTM F-2393: Standard specification for high-purity dense magnesia partially stabilised zirconia (Mg-PSZ) for surgical implant applications. ASTM International 2004.
    • American Society for Testing and Materials. ASTM F-2393: Standard specification for high-purity dense magnesia partially stabilised zirconia (Mg-PSZ) for surgical implant applications. ASTM International 2004.
  • 16
    • 0032917811 scopus 로고    scopus 로고
    • Zirconia as a ceramic biomaterial
    • Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials 1999; 20: 1-25.
    • (1999) Biomaterials , vol.20 , pp. 1-25
    • Piconi, C.1    Maccauro, G.2
  • 17
    • 0033873591 scopus 로고    scopus 로고
    • Transformation toughening in zirconia-containing ceramics
    • Hannink RH, Kelly PM, Muddle BC. Transformation toughening in zirconia-containing ceramics. J Am Ceram Soc 2000; 83: 461-87.
    • (2000) J Am Ceram Soc , vol.83 , pp. 461-487
    • Hannink, R.H.1    Kelly, P.M.2    Muddle, B.C.3
  • 18
    • 0022077265 scopus 로고
    • Transformation of yttria-doped tetragonal ZrO2 polycrystals by annealing in water
    • Sato T, Shimada M. Transformation of yttria-doped tetragonal ZrO2 polycrystals by annealing in water. Journal of the American Ceramic Society 1985; 68: 356-9.
    • (1985) Journal of the American Ceramic Society , vol.68 , pp. 356-359
    • Sato, T.1    Shimada, M.2
  • 20
    • 85047673230 scopus 로고
    • Low temperature degradation of Y-TZP materials
    • Swab JJ. Low temperature degradation of Y-TZP materials. J Mater Sci Mater Med 1991; 26: 6706-14.
    • (1991) J Mater Sci Mater Med , vol.26 , pp. 6706-6714
    • Swab, J.J.1
  • 21
    • 0027607307 scopus 로고
    • Time dependent changes in the mechanical properties of zirconia ceramics
    • Shimizu K, Oka M, Kumar P, et al. Time dependent changes in the mechanical properties of zirconia ceramics. J Biomed Mater Res 1993; 27: 729-34.
    • (1993) J Biomed Mater Res , vol.27 , pp. 729-734
    • Shimizu, K.1    Oka, M.2    Kumar, P.3
  • 22
    • 85036972322 scopus 로고    scopus 로고
    • Calés B. Y-TZP zirconia ceramic hip joint heads: key issues for a high reliability. In: Ravaglioli A, ed. Fourth Euro-Ceramics - 8 Bioceramics. Faenza: Faenza Editrice 1995; 45-52.
    • Calés B. Y-TZP zirconia ceramic hip joint heads: key issues for a high reliability. In: Ravaglioli A, ed. Fourth Euro-Ceramics - Vol. 8 Bioceramics. Faenza: Faenza Editrice 1995; 45-52.
  • 23
    • 0032144008 scopus 로고    scopus 로고
    • Y-TZP Ceramics for artificial joint replacements
    • Piconi C, Burger W, Richter HG, et al. Y-TZP Ceramics for artificial joint replacements. Biomaterials 1998; 16: 1489-94.
    • (1998) Biomaterials , vol.16 , pp. 1489-1494
    • Piconi, C.1    Burger, W.2    Richter, H.G.3
  • 24
    • 0026115091 scopus 로고
    • Effect of alumina addition on the tetragonal-to-monoclinic phase transformation in zirconia-3 mol% yttria
    • Tsubakino H, Nozato R, Hamamoto M. Effect of alumina addition on the tetragonal-to-monoclinic phase transformation in zirconia-3 mol% yttria. Journal of the American Ceramic Society 1991; 74: 440-3.
    • (1991) Journal of the American Ceramic Society , vol.74 , pp. 440-443
    • Tsubakino, H.1    Nozato, R.2    Hamamoto, M.3
  • 25
    • 0035965071 scopus 로고    scopus 로고
    • The role of trace addition of alumina to yttria-tetragonal zirconia polycrystals (Y-TZP)
    • Ross IM, Rainforth WM, McComb DW, Scott AJ, Brydson R. The role of trace addition of alumina to yttria-tetragonal zirconia polycrystals (Y-TZP). Scripta Materialia 2001; 45: 653-60.
    • (2001) Scripta Materialia , vol.45 , pp. 653-660
    • Ross, I.M.1    Rainforth, W.M.2    McComb, D.W.3    Scott, A.J.4    Brydson, R.5
  • 27
    • 0027001643 scopus 로고
    • Inhibition of low temperature degradation of tetragonal zirconia ceramics - a review
    • Hirano M. Inhibition of low temperature degradation of tetragonal zirconia ceramics - a review. Transactions and Journal of the British Ceramic Society 1992; 91: 139-47.
    • (1992) Transactions and Journal of the British Ceramic Society , vol.91 , pp. 139-147
    • Hirano, M.1
  • 28
    • 0029237462 scopus 로고
    • Environmental degradation of zirconia ceramics
    • Lawson S. Environmental degradation of zirconia ceramics. Journal of the European Ceramic Society 1995; 15: 485-502.
    • (1995) Journal of the European Ceramic Society , vol.15 , pp. 485-502
    • Lawson, S.1
  • 30
    • 0032886208 scopus 로고    scopus 로고
    • Poor eight-years survival of cemented zirconia-polyethylene total hip replacements
    • Allain J, Le Mouel S, Goutaillier D, Voisin MC. Poor eight-years survival of cemented zirconia-polyethylene total hip replacements. J Bone Joint Surg Br 1999; 81: 835-42.
    • (1999) J Bone Joint Surg Br , vol.81 , pp. 835-842
    • Allain, J.1    Le Mouel, S.2    Goutaillier, D.3    Voisin, M.C.4
  • 33
    • 0034926714 scopus 로고    scopus 로고
    • A comparison of polyethylene wear in hips with cobalt-chrome or zirconia heads
    • Kim YH, Kim JS, Cho SH. A comparison of polyethylene wear in hips with cobalt-chrome or zirconia heads. J Bone Joint Surg Br 2001; 83: 742-50.
    • (2001) J Bone Joint Surg Br , vol.83 , pp. 742-750
    • Kim, Y.H.1    Kim, J.S.2    Cho, S.H.3
  • 34
    • 0036325167 scopus 로고    scopus 로고
    • Catastrophic failure of Elite Plus total hip replacement with Hylamer acetabulum and zirconia ceramic femoral head
    • Norton MR, Yarlagadda R, Anderson GH. Catastrophic failure of Elite Plus total hip replacement with Hylamer acetabulum and zirconia ceramic femoral head. J Bone Joint Surg Br 2002; 84: 631-5.
    • (2002) J Bone Joint Surg Br , vol.84 , pp. 631-635
    • Norton, M.R.1    Yarlagadda, R.2    Anderson, G.H.3
  • 35
    • 0038441585 scopus 로고    scopus 로고
    • Zirconia and alumina ceramics in comparison with stainless steel heads
    • Hernigou P, Bahrami T. Zirconia and alumina ceramics in comparison with stainless steel heads. J Bone Joint Surg Br 2003; 85: 504-9.
    • (2003) J Bone Joint Surg Br , vol.85 , pp. 504-509
    • Hernigou, P.1    Bahrami, T.2
  • 36
    • 0037397639 scopus 로고    scopus 로고
    • Wear of enhanced ultra-high molecular weight polyethylene (Hylamer) in combination with a 22.225 mm diameter zirconia femoral head
    • Wroblewski BM, Siney PD, Fleming PA. Wear of enhanced ultra-high molecular weight polyethylene (Hylamer) in combination with a 22.225 mm diameter zirconia femoral head. J Bone Joint Surg Br 2003; 85: 376-9.
    • (2003) J Bone Joint Surg Br , vol.85 , pp. 376-379
    • Wroblewski, B.M.1    Siney, P.D.2    Fleming, P.A.3
  • 37
    • 3042643604 scopus 로고    scopus 로고
    • Wear of ultra-high-molecular-weight polyethylene cup articulating with 22.225 mm zirconia diameter head in cemented total hip arthroplasty
    • Wroblewski BM, Siney PD, Nagai H, Fleming PA. Wear of ultra-high-molecular-weight polyethylene cup articulating with 22.225 mm zirconia diameter head in cemented total hip arthroplasty. J Orthop Sci 2004; 9: 253-5.
    • (2004) J Orthop Sci , vol.9 , pp. 253-255
    • Wroblewski, B.M.1    Siney, P.D.2    Nagai, H.3    Fleming, P.A.4
  • 40
    • 24644439149 scopus 로고    scopus 로고
    • Hylamer wear rates and shelf life: A clinical correlation
    • Kiely PD, Harty JA, McElwain JP. Hylamer wear rates and shelf life: A clinical correlation. Acta Orthop Belg 2005; 71: 429-34.
    • (2005) Acta Orthop Belg , vol.71 , pp. 429-434
    • Kiely, P.D.1    Harty, J.A.2    McElwain, J.P.3
  • 41
    • 23044447438 scopus 로고    scopus 로고
    • Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement
    • Kim YO. Comparison of polyethylene wear associated with cobalt-chromium and zirconia heads after total hip replacement. J Bone Joint Surg Am 2005; 87: 1769-76.
    • (2005) J Bone Joint Surg Am , vol.87 , pp. 1769-1776
    • Kim, Y.O.1
  • 43
    • 17444450453 scopus 로고    scopus 로고
    • Clinical and laboratory wear studies of zirconia-on-UHMWPE combination in cementless THA
    • Nakamura T, Tanaka K, Tamura J, et al. Clinical and laboratory wear studies of zirconia-on-UHMWPE combination in cementless THA. Key Eng Mater 2005; 240-2: 823-6.
    • (2005) Key Eng Mater
    • Nakamura, T.1    Tanaka, K.2    Tamura, J.3
  • 44
  • 46
    • 36549077856 scopus 로고    scopus 로고
    • Charnley type with Zr/PE bearing results of more than 5 years FU
    • Benazzo F, Falez F, Dietrich M, eds, Darmstadt: Steinkopff
    • Caton JH. THR Charnley type with Zr/PE bearing results of more than 5 years FU. In: Benazzo F, Falez F, Dietrich M, eds. Bioceramics and alternative bearings in joint arthroplasty. Darmstadt: Steinkopff 2006; 293-4.
    • (2006) Bioceramics and alternative bearings in joint arthroplasty , pp. 293-294
    • Caton, J.T.1
  • 49
    • 0000853641 scopus 로고
    • Yttria-stabilised zirconia for improved orthopedic prostheses
    • Wise DL, Trantolo DJ, Altobelli DE, et al, eds, New York: Marcel Dekker
    • Calés B, Stefani Y. Yttria-stabilised zirconia for improved orthopedic prostheses. In: Wise DL, Trantolo DJ, Altobelli DE, et al, eds. Encyclopedic Handbook of Biomaterials and Bioengineering. New York: Marcel Dekker 1995; 415-52.
    • (1995) Encyclopedic Handbook of Biomaterials and Bioengineering , pp. 415-452
    • Calés, B.1    Stefani, Y.2
  • 50
    • 33845197286 scopus 로고    scopus 로고
    • Determination of crystallinity and crystal structure of Hylamer polyethylene after in vivo wear
    • Visentin M, Stea S, De Clerico M, et al. Determination of crystallinity and crystal structure of Hylamer polyethylene after in vivo wear. J Biomater Appl 2006; 21: 131-45.
    • (2006) J Biomater Appl , vol.21 , pp. 131-145
    • Visentin, M.1    Stea, S.2    De Clerico, M.3
  • 51
  • 52
    • 10744222195 scopus 로고    scopus 로고
    • Current status of zirconia used in total hip implants
    • Clarke IC, Manaka M, Green D, et al. Current status of zirconia used in total hip implants. J Bone Joint Surg Am 2003; 85 (suppl 4): 73-84.
    • (2003) J Bone Joint Surg Am , vol.85 , Issue.SUPPL. 4 , pp. 73-84
    • Clarke, I.C.1    Manaka, M.2    Green, D.3
  • 54
    • 36549041134 scopus 로고    scopus 로고
    • Phase transformation of zircone heads after total hip arthroplasty: Myth or reality?
    • Caton J, Bouraly JP, Reynaud P, Merabet Z. Phase transformation of zircone heads after total hip arthroplasty: myth or reality? J Bone Joint Surg Br 2004; 87 (suppl 2): 120.
    • (2004) J Bone Joint Surg Br , vol.87 , Issue.SUPPL. 2 , pp. 120
    • Caton, J.1    Bouraly, J.P.2    Reynaud, P.3    Merabet, Z.4
  • 55
    • 26844583254 scopus 로고    scopus 로고
    • What future for zirconia as a biomaterial?
    • Chevalier J. What future for zirconia as a biomaterial? Biomaterials 2006; 27: 535-43.
    • (2006) Biomaterials , vol.27 , pp. 535-543
    • Chevalier, J.1
  • 56
    • 0029616189 scopus 로고
    • Catastrophic failure of modular zirconia ceramic femoral head components after total hip arthroplasty
    • Hummer CD, Rothman RH, Hozack WJ. Catastrophic failure of modular zirconia ceramic femoral head components after total hip arthroplasty. J Arthroplasty 1995; 10: 848-50.
    • (1995) J Arthroplasty , vol.10 , pp. 848-850
    • Hummer, C.D.1    Rothman, R.H.2    Hozack, W.J.3
  • 58
    • 33645307325 scopus 로고    scopus 로고
    • Fractures des têtes de prothèses de hanche en zircone
    • Calés B. Fractures des têtes de prothèses de hanche en zircone. Mâitrise Orthopédique 2000; 96: 26-30.
    • (2000) Mâitrise Orthopédique , vol.96 , pp. 26-30
    • Calés, B.1
  • 62
    • 2142786988 scopus 로고    scopus 로고
    • Experience with ceramic heads and friction with polyethylene or alumina cups in hip surgery. A new couple zirconia-alumina. About 163 cases
    • Presented at the Workshop, Honolulu, May
    • Banon F. Experience with ceramic heads and friction with polyethylene or alumina cups in hip surgery. A new couple zirconia-alumina. About 163 cases. Presented at the 6th World Biomaterials Conference - Workshop 7. Honolulu, May 2000.
    • (2000) 6th World Biomaterials Conference , pp. 7
    • Banon, F.1
  • 63
    • 85036993843 scopus 로고    scopus 로고
    • last accessed June 24, 2005
    • http://www.Prozyr®.com/PAGES_FR/Biomedical/chiffres.htm (last accessed June 24, 2005).
  • 65
    • 0035983868 scopus 로고    scopus 로고
    • Reliability and properties of ground Y-TZP zirconia ceramics
    • Luthard RG, Holzüter M, Sandkul O, et al. Reliability and properties of ground Y-TZP zirconia ceramics. J Dent Res 2002; 81: 487-91.
    • (2002) J Dent Res , vol.81 , pp. 487-491
    • Luthard, R.G.1    Holzüter, M.2    Sandkul, O.3
  • 67
    • 11844264547 scopus 로고    scopus 로고
    • Influence of surface and heath treatment on the flexural strength of Y-TZP dental ceramics
    • Guazzato M, Quach L, Albakoy M, Swain MV. Influence of surface and heath treatment on the flexural strength of Y-TZP dental ceramics. J Dent 2005; 33: 9-18.
    • (2005) J Dent , vol.33 , pp. 9-18
    • Guazzato, M.1    Quach, L.2    Albakoy, M.3    Swain, M.V.4
  • 68
    • 0035154596 scopus 로고    scopus 로고
    • Ageing of zirconia: Everything you always wanted to know
    • Blaise L, Villermaux F, Calés B. Ageing of zirconia: everything you always wanted to know. Key Eng Mater 2001; 192-5: 553-6.
    • (2001) Key Eng Mater
    • Blaise, L.1    Villermaux, F.2    Calés, B.3
  • 69
    • 0034951336 scopus 로고    scopus 로고
    • Effect of HIPping, stress and surface finish on the environmental degradation of Y-TZP ceramics
    • Grant KL, Rawlings RD, Sweeney R. Effect of HIPping, stress and surface finish on the environmental degradation of Y-TZP ceramics. J Mater Sci Mater Med 2001; 12: 557-64.
    • (2001) J Mater Sci Mater Med , vol.12 , pp. 557-564
    • Grant, K.L.1    Rawlings, R.D.2    Sweeney, R.3
  • 71
    • 0033957831 scopus 로고    scopus 로고
    • Factors contributing to rapid wear and osteolysis in hip with modular acetabular bearings made of Hylamer
    • Scott DL, Campbell PA, McClung CD, Schmalzried TP. Factors contributing to rapid wear and osteolysis in hip with modular acetabular bearings made of Hylamer. J Arthroplasty 2000; 15: 35-46.
    • (2000) J Arthroplasty , vol.15 , pp. 35-46
    • Scott, D.L.1    Campbell, P.A.2    McClung, C.D.3    Schmalzried, T.P.4
  • 72
    • 0036023527 scopus 로고    scopus 로고
    • A literature review of the association between wear rate and osteolysis in total hip arthroplasty
    • Dumbleton JH, Manley MT, Ediddin AA. A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty 2002; 17: 649-61.
    • (2002) J Arthroplasty , vol.17 , pp. 649-661
    • Dumbleton, J.H.1    Manley, M.T.2    Ediddin, A.A.3
  • 74
    • 9244231116 scopus 로고    scopus 로고
    • Fracture of a Y-TZP ceramic femoral head. Analysis of a fault
    • Maccauro G, Piconi C, Burger W, et al. Fracture of a Y-TZP ceramic femoral head. Analysis of a fault. J Bone Joint Surg Br 2004; 86: 1192-6.
    • (2004) J Bone Joint Surg Br , vol.86 , pp. 1192-1196
    • Maccauro, G.1    Piconi, C.2    Burger, W.3
  • 75
    • 85036980210 scopus 로고    scopus 로고
    • Fractures des têtes de prothèses de hanche en zircone - le point de vue du fabricant
    • Presented at, Clermont-Ferrand, October
    • Calés B. Fractures des têtes de prothèses de hanche en zircone - le point de vue du fabricant. Presented at 4é Jounées d'Orthopedie P Teinturier. Clermont-Ferrand, October 2002.
    • (2002) 4é Jounées d'Orthopedie P Teinturier
    • Calés, B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.