Volumn 85, Issue 3, 2003, Pages 376-379

Wear of enhanced ultra-high molecular-weight polyethylene (Hylamer) in combination with a 22.225 mm diameter zirconia femoral head

Author keywords

[No Author keywords available]

Indexed keywords

POLYETHYLENE; ZIRCONIUM OXIDE;

EID: 0037397639     PISSN: 0301620X     EISSN: None     Source Type: Journal    
DOI: 10.1302/0301-620X.85B3.13817     Document Type: Article
Times cited : (34)

References (23)
  • 1
    • 0000021856 scopus 로고
    • Charnley low friction arthroplasty in patients under the age of 40 years
    • Sevastik J, Goldie I, eds. Stockholm: Almqvist & Wiksell
    • Wroblewski BM. Charnley low friction arthroplasty in patients under the age of 40 years. In: Sevastik J, Goldie I, eds. The young patient with degenerative hip disease. Stockholm: Almqvist & Wiksell, 1985:197-201.
    • (1985) The Young Patient With Degenerative Hip Disease , pp. 197-201
    • Wroblewski, B.M.1
  • 2
    • 0033027601 scopus 로고    scopus 로고
    • Charnley low-frictional torque arthroplasty of the hip: 20-30 year results
    • Wroblewski BM, Fleming PA, Siney PD. Charnley low-frictional torque arthroplasty of the hip: 20-30 year results. J Bone Joint Surg [Br] 1999;81-B:427-9.
    • (1999) J. Bone Joint Surg. [Br] , vol.81 B , pp. 427-429
    • Wroblewski, B.M.1    Fleming, P.A.2    Siney, P.D.3
  • 3
    • 0029887658 scopus 로고    scopus 로고
    • Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups
    • Wroblewski BM, Siney PD, Dowson D, Collins SN. Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups. J Bone Joint Surg [Br] 1996;78-B:280-5.
    • (1996) J. Bone Joint Surg. [Br] , vol.78 B , pp. 280-285
    • Wroblewski, B.M.1    Siney, P.D.2    Dowson, D.3    Collins, S.N.4
  • 4
    • 0023924033 scopus 로고
    • Socket design and cement pressurisation in the Charnley low-friction arthroplasty
    • Shelley P, Wroblewski BM. Socket design and cement pressurisation in the Charnley low-friction arthroplasty. J Bone Joint Surg [Br] 1988;70-B:358-63.
    • (1988) J. Bone Joint Surg. [Br] , vol.70 B , pp. 358-363
    • Shelley, P.1    Wroblewski, B.M.2
  • 6
    • 0035216886 scopus 로고    scopus 로고
    • Triple taper polished cemented stem in total hip arthroplasty: Rationale for the design, surgical technique and 7 years of clinical experience
    • Wroblewski BM, Siney PD, Fleming PA. Triple taper polished cemented stem in total hip arthroplasty: rationale for the design, surgical technique and 7 years of clinical experience. J Arthroplasty 2001;16(Suppl 1):37-41.
    • (2001) J. Arthroplasty , vol.16 , Issue.SUPPL. 1 , pp. 37-41
    • Wroblewski, B.M.1    Siney, P.D.2    Fleming, P.A.3
  • 7
    • 0022202918 scopus 로고
    • Reattachment of the greater trochanter after hip replacement
    • Wroblewski BM, Shelley P. Reattachment of the greater trochanter after hip replacement. J Bone Joint Surg [Br] 1985;67-B:736-40.
    • (1985) J. Bone Joint Surg. [Br] , vol.67 B , pp. 736-740
    • Wroblewski, B.M.1    Shelley, P.2
  • 8
    • 0034068975 scopus 로고    scopus 로고
    • Charnley low friction arthroplasty with an autograft of the femoral head for developmental dysplasia of the hip: The 10- to 15-year results
    • Bobak P, Wroblewski BM, Siney PD, Fleming PA, Hall R. Charnley low friction arthroplasty with an autograft of the femoral head for developmental dysplasia of the hip: the 10- to 15-year results. J Bone Joint Surg [Br] 2000;82-B:508-11.
    • (2000) J. Bone Joint Surg. [Br] , vol.82 B , pp. 508-511
    • Bobak, P.1    Wroblewski, B.M.2    Siney, P.D.3    Fleming, P.A.4    Hall, R.5
  • 9
    • 0033251203 scopus 로고    scopus 로고
    • Analysis of debris from brushing the femoral canal with a plastic brush: A potential cause of loosening in total hip replacement
    • Germain MA, Tipper JL, Ingham E, et al. Analysis of debris from brushing the femoral canal with a plastic brush: a potential cause of loosening in total hip replacement. Proc Inst Mech Eng (H) 1999;213:503-6.
    • (1999) Proc. Inst. Mech. Eng. (H) , vol.213 , pp. 503-506
    • Germain, M.A.1    Tipper, J.L.2    Ingham, E.3
  • 12
    • 0021680452 scopus 로고
    • Intramedullary cancellous bone block to improve femoral stem fixation in Charnley low-friction arthroplasty
    • Wroblewski BM, van der Rijt A. Intramedullary cancellous bone block to improve femoral stem fixation in Charnley low-friction arthroplasty. J Bone Joint Surg [Br] 1984;66-B:639-44.
    • (1984) J. Bone Joint Surg. [Br] , vol.66 B , pp. 639-644
    • Wroblewski, B.M.1    van der Rijt, A.2
  • 13
    • 77049159486 scopus 로고
    • Functional results of hip arthroplasty with acrylic prosthesis
    • Merle d'Aubigné R, Postel M. Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg [Am] 1954;36-A:451-75.
    • (1954) J. Bone Joint Surg. [Am] , vol.36 A , pp. 451-475
    • Merle d'Aubigné, R.1    Postel, M.2
  • 14
    • 0015295233 scopus 로고
    • The long term results of low friction arthroplasty of the hip performed as a primary intervention
    • Charnley J. The long term results of low friction arthroplasty of the hip performed as a primary intervention. J Bone Joint Surg [Br] 1972;54-B:61-76.
    • (1972) J. Bone Joint Surg. [Br] , vol.54 B , pp. 61-76
    • Charnley, J.1
  • 15
    • 0023908985 scopus 로고
    • The correlation between the roentgenographic appearance and the operative findings at the bone-cement junction of the socket in Charnley low friction arthroplasties
    • Hodgkinson JP, Shelley P, Wroblewski BM. The correlation between the roentgenographic appearance and the operative findings at the bone-cement junction of the socket in Charnley low friction arthroplasties. Clin Orthop 1988;228:105-9.
    • (1988) Clin. Orthop. , vol.228 , pp. 105-109
    • Hodgkinson, J.P.1    Shelley, P.2    Wroblewski, B.M.3
  • 16
    • 0023752629 scopus 로고
    • Mechanical loosening of the stem in Charnley arthroplasties: Identification of the "at risk" factors
    • Pacheco V, Shelley P, Wroblewski BM. Mechanical loosening of the stem in Charnley arthroplasties: identification of the "at risk" factors. J Bone Joint Surg [Br] 1988;70-B:596-9.
    • (1988) J. Bone Joint Surg. [Br] , vol.70 B , pp. 569-596
    • Pacheco, V.1    Shelley, P.2    Wroblewski, B.M.3
  • 17
    • 0018687995 scopus 로고
    • "Modes of failure" of cemented stem-type femoral components: A radiographic analysis of loosening
    • Gruen TA, McNeice GM, Amstutz HC. "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 1979;141:17-27.
    • (1979) Clin. Orthop. , vol.141 , pp. 17-27
    • Gruen, T.A.1    McNeice, G.M.2    Amstutz, H.C.3
  • 19
    • 0025343488 scopus 로고
    • Effect of femoral head size on wear of the polyethylene acetabular component
    • Livermore J, Ilstrup D, Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg [Am] 1990;72-A:518-28.
    • (1990) J. Bone Joint Surg. [Am] , vol.72 A , pp. 518-528
    • Livermore, J.1    Ilstrup, D.2    Morrey, B.3
  • 20
    • 0036325167 scopus 로고    scopus 로고
    • Catastrophic failure of the Elite Plus total hip replacement with a Hylamer acetabulum and zirconia ceramic femoral head
    • Norton MR, Yarlagadda R, Anderson GH. Catastrophic failure of the Elite Plus total hip replacement with a Hylamer acetabulum and zirconia ceramic femoral head. J Bone Joint Surg [Br] 2002;84-B:631-5.
    • (2002) J. Bone Joint Surg. [Br] , vol.84 B , pp. 631-635
    • Norton, M.R.1    Yarlagadda, R.2    Anderson, G.H.3
  • 21
    • 0019973312 scopus 로고
    • Revision surgery in total hip arthroplasty: Surgical technique and results
    • Wroblewski BM. Revision surgery in total hip arthroplasty: surgical technique and results. Clin Orthop 1982;170:56-61.
    • (1982) Clin. Orthop. , vol.170 , pp. 56-61
    • Wroblewski, B.M.1
  • 22
    • 0031911135 scopus 로고    scopus 로고
    • Stem fixation in the Charnley low friction arthroplasty in young patients using an intramedullary bone block
    • Wroblewski BM, Fleming PA, Hall RM, Siney PD. Stem fixation in the Charnley low friction arthroplasty in young patients using an intramedullary bone block. J Bone Joint Surg [Br] 1998;80-B: 273-8.
    • (1998) J. Bone Joint Surg. [Br] , vol.80 B , pp. 273-278
    • Wroblewski, B.M.1    Fleming, P.A.2    Hall, R.M.3    Siney, P.D.4
  • 23
    • 0344195725 scopus 로고    scopus 로고
    • NICE Technology Appraisal Guidance No.2. April
    • NICE Technology Appraisal Guidance No.2. April 2002.
    • (2002)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.