-
1
-
-
0033771089
-
Zirconia as a sliding material: Histologic, laboratory, and clinical data
-
Cales B. Zirconia as a sliding material: histologic, laboratory, and clinical data. Clin Orthop 2000; 379: 94-112.
-
(2000)
Clin. Orthop.
, vol.379
, pp. 94-112
-
-
Cales, B.1
-
2
-
-
0029902177
-
Ceramic femoral head fractures in total hip arthroplasty
-
Fritsch EW, Gleitz M. Ceramic femoral head fractures in total hip arthroplasty. Clin Orthop 1996; 328: 129-36.
-
(1996)
Clin. Orthop.
, vol.328
, pp. 129-136
-
-
Fritsch, E.W.1
Gleitz, M.2
-
3
-
-
0029558604
-
Spontaneous fracture of the ceramic ball in a ceramic-polyethylene total hip arthroplasty
-
Michaud RJ, Rashad SY. Spontaneous fracture of the ceramic ball in a ceramic-polyethylene total hip arthroplasty. J Arthroplasty 1995; 10-6: 863-7.
-
(1995)
J. Arthroplasty
, vol.10
, Issue.16
, pp. 863-867
-
-
Michaud, R.J.1
Rashad, S.Y.2
-
5
-
-
0020576705
-
The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis
-
Goldring SR, Schiller AL, Roelke M, Rourke CM, O'Neil DA, Harris WH. The synovial-like membrane at the bone-cement interface in loose total hip replacements and its proposed role in bone lysis. J Bone Joint Surg (Am) 1983; 65-A: 575-84.
-
(1983)
J. Bone Joint Surg. (Am.)
, vol.65 A
, pp. 575-584
-
-
Goldring, S.R.1
Schiller, A.L.2
Roelke, M.3
Rourke, C.M.4
O'Neil, D.A.5
Harris, W.H.6
-
6
-
-
0027983089
-
Composition and morphology of wear debris in failed uncemented total hip replacement
-
Shanbhag AS, Jacobs JJ, Glant TT, Gilbert JL, Black J, Galante JO. Composition and morphology of wear debris in failed uncemented total hip replacement. J Bone Joint Surg (Br) 1994; 76-B: 60-7.
-
(1994)
J. Bone Joint Surg. (Br.)
, vol.76 B
, pp. 60-67
-
-
Shanbhag, A.S.1
Jacobs, J.J.2
Glant, T.T.3
Gilbert, J.L.4
Black, J.5
Galante, J.O.6
-
7
-
-
0032927112
-
Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements
-
McKellop H, Shen FW, Lu B, Campbell P, Salovey R. Development of an extremely wear-resistant ultra high molecular weight polyethylene for total hip replacements. J Orthop Res 1999; 17: 157-67.
-
(1999)
J. Orthop. Res.
, vol.17
, pp. 157-167
-
-
McKellop, H.1
Shen, F.W.2
Lu, B.3
Campbell, P.4
Salovey, R.5
-
8
-
-
0023007566
-
The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement
-
Bartel DL, Bicknell VL, Wright TM. The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement. J Bone Joint Surg (Am) 1986; 68-A: 1041-51.
-
(1986)
J. Bone Joint Surg. (Am.)
, vol.68 A
, pp. 1041-1051
-
-
Bartel, D.L.1
Bicknell, V.L.2
Wright, T.M.3
-
9
-
-
0025343488
-
Effect of femoral head size on wear of the polyethylene acetabular component
-
Livermore J, Ilstrup D, Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg (Am) 1990; 72-A: 518-28.
-
(1990)
J. Bone Joint Surg. (Am.)
, vol.72 A
, pp. 518-528
-
-
Livermore, J.1
Ilstrup, D.2
Morrey, B.3
-
10
-
-
0029125716
-
Wear of the polyethylene of Harris-Galante acetabular components inserted without cement
-
Woolson ST, Murphy MG. Wear of the polyethylene of Harris-Galante acetabular components inserted without cement. J Bone Joint Surg (Am) 1995; 77-A: 1311-4.
-
(1995)
J. Bone Joint Surg. (Am.)
, vol.77 A
, pp. 1311-1314
-
-
Woolson, S.T.1
Murphy, M.G.2
-
12
-
-
0015233325
-
Alumina and its use in surgery of the hip. (Experimental study)
-
Boutin P. Alumina and its use in surgery of the hip. (Experimental study). Presse Med 1971; 79-14: 639-40.
-
(1971)
Presse Med.
, vol.79
, Issue.14
, pp. 639-640
-
-
Boutin, P.1
-
13
-
-
0024255826
-
The use of dense alumina-alumina ceramic combination in total hip replacement
-
Boutin P, Christel P, Dorlot JM, et al. The use of dense alumina-alumina ceramic combination in total hip replacement. J Biomed Mater Res 1988; 22: 1203-32.
-
(1988)
J. Biomed. Mater. Res.
, vol.22
, pp. 1203-1232
-
-
Boutin, P.1
Christel, P.2
Dorlot, J.M.3
-
14
-
-
0032917811
-
Zirconia as a ceramic biomaterial
-
Piconi C, Maccauro G. Zirconia as a ceramic biomaterial. Biomaterials 1999; 20: 1-25.
-
(1999)
Biomaterials
, vol.20
, pp. 1-25
-
-
Piconi, C.1
Maccauro, G.2
-
16
-
-
0029887658
-
Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups
-
Wroblewski BM, Siney PD, Dowson D, Collins SN. Prospective clinical and joint simulator studies of a new total hip arthroplasty using alumina ceramic heads and cross-linked polyethylene cups. J Bone Joint Surg (Br) 1996; 78-B: 280-5.
-
(1996)
J. Bone Joint Surg. (Br.)
, vol.78 B
, pp. 280-285
-
-
Wroblewski, B.M.1
Siney, P.D.2
Dowson, D.3
Collins, S.N.4
-
17
-
-
0033034126
-
Analysis of temporal wear patterns of porous-coated acetabular components: Distinguishing between true wear and so-called bedding-in
-
Sychterz CJ, Engh CA, Jr, Yang A, Engh CA. Analysis of temporal wear patterns of porous-coated acetabular components: distinguishing between true wear and so-called bedding-in. J Bone Joint Surg (Am) 1999; 81-A: 821-30.
-
(1999)
J. Bone Joint Surg. (Am.)
, vol.81 A
, pp. 821-830
-
-
Sychterz, C.J.1
Engh Jr., C.A.2
Yang, A.3
Engh, C.A.4
-
18
-
-
0030669292
-
Determination of polyethylene wear in total hip replacements with use of digital radiographs
-
Martell JM, Berdia S. Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg (Am) 1997; 79-A: 1635-41.
-
(1997)
J. Bone Joint Surg. (Am.)
, vol.79 A
, pp. 1635-1641
-
-
Martell, J.M.1
Berdia, S.2
-
19
-
-
0029051089
-
Increasing prevalence of femoral lysis in cementless total hip arthroplasty
-
Smith E, Harris WH. Increasing prevalence of femoral lysis in cementless total hip arthroplasty. J Arthroplasty 1995; 10: 407-12.
-
(1995)
J. Arthroplasty
, vol.10
, pp. 407-412
-
-
Smith, E.1
Harris, W.H.2
-
20
-
-
0018687995
-
"Modes of failure" of cemented stem-type femoral components: A radiographic analysis of loosening
-
Gruen TA, McNeice GM, Amstutz HC. "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop 1979; 141: 17-27.
-
(1979)
Clin. Orthop.
, vol.141
, pp. 17-27
-
-
Gruen, T.A.1
McNeice, G.M.2
Amstutz, H.C.3
-
21
-
-
0030627862
-
Frictional heating of bearing materials tested in a hip joint wear simulator
-
Lu Z, McKellop H. Frictional heating of bearing materials tested in a hip joint wear simulator. Proc Inst Mech Eng [H] 1997; 211: 101-8.
-
(1997)
Proc. Inst. Mech. Eng. [H]
, vol.211
, pp. 101-108
-
-
Lu, Z.1
McKellop, H.2
-
22
-
-
0035176116
-
Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty. Seventeen to twenty-one-year results
-
Urban JA, Garvin KL, Boese CK, et al. Ceramic-on-polyethylene bearing surfaces in total hip arthroplasty. Seventeen to twenty-one-year results. J Bone Joint Surg (Am) 2001; 83-A: 1688-94.
-
(2001)
J. Bone Joint Surg. (Am.)
, vol.83 A
, pp. 1688-1694
-
-
Urban, J.A.1
Garvin, K.L.2
Boese, C.K.3
-
23
-
-
0034787363
-
Analysis of survivorship after total hip arthroplasty using a ceramic head
-
Haraguchi K, Sugano N, Nishii T, Sakai T, Yoshikawa H, Ohzono K. Analysis of survivorship after total hip arthroplasty using a ceramic head. Clin Orthop 2001; 391: 198-209.
-
(2001)
Clin. Orthop.
, vol.391
, pp. 198-209
-
-
Haraguchi, K.1
Sugano, N.2
Nishii, T.3
Sakai, T.4
Yoshikawa, H.5
Ohzono, K.6
-
24
-
-
0036325167
-
Catastrophic failure of the Elite Plus total hip replacement, with a Hylamer acetabulum and Zirconia ceramic femoral head
-
Norton MR, Yarlagadda R, Anderson GH. Catastrophic failure of the Elite Plus total hip replacement, with a Hylamer acetabulum and Zirconia ceramic femoral head. J Bone Joint Surg (Br) 2002; 84-B: 631-5.
-
(2002)
J. Bone Joint Surg. (Br.)
, vol.84 B
, pp. 631-635
-
-
Norton, M.R.1
Yarlagadda, R.2
Anderson, G.H.3
-
25
-
-
0037397639
-
Wear of enhanced ultra-high molecular-weight polyethylene (Hylamer) in combination with a 22.225 mm diameter Zirconia femoral head
-
Wroblewski BM, Siney PD, Fleming PA. Wear of enhanced ultra-high molecular-weight polyethylene (Hylamer) in combination with a 22.225 mm diameter Zirconia femoral head. J Bone Joint Surg (Br) 2003; 85-B: 376-9.
-
(2003)
J. Bone Joint Surg. (Br.)
, vol.85 B
, pp. 376-379
-
-
Wroblewski, B.M.1
Siney, P.D.2
Fleming, P.A.3
-
26
-
-
0032786064
-
Fixation, polyethylene wear, and pelvic osteolysis in primary total hip replacement
-
Maloney WJ, Galante JO, Anderson M, et al. Fixation, polyethylene wear, and pelvic osteolysis in primary total hip replacement. Clin Orthop 1999; 369: 157-64.
-
(1999)
Clin. Orthop.
, vol.369
, pp. 157-164
-
-
Maloney, W.J.1
Galante, J.O.2
Anderson, M.3
-
27
-
-
0038441585
-
Zirconia and alumina ceramics in comparison with stainless-steel heads. Polyethylene wear after a minimum ten-year follow-up
-
Hernigou P, Bahrami T. Zirconia and alumina ceramics in comparison with stainless-steel heads. Polyethylene wear after a minimum ten-year follow-up. J Bone Joint Surg (Br) 2003; 85-B: 504-9.
-
(2003)
J. Bone Joint Surg. (Br.)
, vol.85 B
, pp. 504-509
-
-
Hernigou, P.1
Bahrami, T.2
-
28
-
-
0032785232
-
Primary total hip arthroplasty with a cementless porous-coated anatomic total hip prosthesis: 10- to 12-year results of prospective and consecutive series
-
Kim YH, Kim JS, Cho SH. Primary total hip arthroplasty with a cementless porous-coated anatomic total hip prosthesis: 10- to 12-year results of prospective and consecutive series. J Arthroplasty 1999; 14: 538-48.
-
(1999)
J. Arthroplasty
, vol.14
, pp. 538-548
-
-
Kim, Y.H.1
Kim, J.S.2
Cho, S.H.3
-
29
-
-
0032800733
-
Deformation of the acetabular polyethylene liner and the back-side gap
-
Yamaguchi M, Bauer TW, Hashimoto Y. Deformation of the acetabular polyethylene liner and the back-side gap. J Arthroplasty 1999; 14: 464-9.
-
(1999)
J. Arthroplasty
, vol.14
, pp. 464-469
-
-
Yamaguchi, M.1
Bauer, T.W.2
Hashimoto, Y.3
-
30
-
-
0036023527
-
A literature review of the association between wear rate and osteolysis in total hip arthroplasty
-
Dumbleton JH, Manley MT, Edidin AA. A literature review of the association between wear rate and osteolysis in total hip arthroplasty. J Arthroplasty 2002; 17: 649-61.
-
(2002)
J. Arthroplasty
, vol.17
, pp. 649-661
-
-
Dumbleton, J.H.1
Manley, M.T.2
Edidin, A.A.3
|