메뉴 건너뛰기




Volumn 20, Issue 11, 2007, Pages

SQUID-based instrumentation for ultralow-field MRI

Author keywords

[No Author keywords available]

Indexed keywords

FOURIER ANALYSIS; MAGNETIC FIELDS; MAGNETIC RESONANCE IMAGING; MAGNETOENCEPHALOGRAPHY; MAGNETOMETERS; SPIN DYNAMICS;

EID: 36448987563     PISSN: 09532048     EISSN: 13616668     Source Type: Journal    
DOI: 10.1088/0953-2048/20/11/S13     Document Type: Conference Paper
Times cited : (88)

References (25)
  • 3
    • 2942563757 scopus 로고    scopus 로고
    • SQUID-detected magnetic resonance imaging in microtesla magnetic fields
    • McDermott R et al 2004 SQUID-detected magnetic resonance imaging in microtesla magnetic fields J. Low Temp. Phys. 135 793-821
    • (2004) J. Low Temp. Phys. , vol.135 , Issue.5-6 , pp. 793-821
    • McDermott, R.1    Al, E.2
  • 6
    • 4243202770 scopus 로고    scopus 로고
    • Simultaneous magnetoencephalography and SQUID detected nuclear MR in microtesla magnetic fields
    • Volegov P, Matlachov A N, Espy M A, George J S and Kraus R H Jr 2004 Simultaneous magnetoencephalography and SQUID detected nuclear MR in microtesla magnetic fields Magn. Reson. Med. 52 467-70
    • (2004) Magn. Reson. Med. , vol.52 , Issue.3 , pp. 467-470
    • Volegov, P.1    Matlachov, A.N.2    Espy, M.A.3    George, J.S.4    Kraus, R.H.5
  • 7
  • 9
    • 33645522119 scopus 로고    scopus 로고
    • Nuclear magnetic resonance in the nanotesla range
    • Burghoff M, Hartwig S and Trahms L 2005 Nuclear magnetic resonance in the nanotesla range Appl. Phys. Lett. 87 054103
    • (2005) Appl. Phys. Lett. , vol.87 , pp. 054103
    • Burghoff, M.1    Hartwig, S.2    Trahms, L.3
  • 11
    • 0027200495 scopus 로고
    • Novel approaches to low cost MRI
    • Macovski A and Conolly S 1993 Novel approaches to low cost MRI Magn. Reson. Med. 30 221-30
    • (1993) Magn. Reson. Med. , vol.30 , Issue.2 , pp. 221-230
    • MacOvski, A.1    Conolly, S.2
  • 14
    • 0030283613 scopus 로고    scopus 로고
    • NMR of room temperature samples with a flux-locked dc SQUID
    • Kumar S, Avrin W F and Whitecotton B R 1996 NMR of room temperature samples with a flux-locked dc SQUID IEEE Trans. Magn. 32 5261-4
    • (1996) IEEE Trans. Magn. , vol.32 , Issue.6 , pp. 5261-5264
    • Kumar, S.1    Avrin, W.F.2    Whitecotton, B.R.3
  • 16
    • 0032345068 scopus 로고    scopus 로고
    • Application of superconducting quantum interference devices to nuclear magnetic resonance
    • Greenberg Y S 1998 Application of superconducting quantum interference devices to nuclear magnetic resonance Rev. Mod. Phys. 70 175-222
    • (1998) Rev. Mod. Phys. , vol.70 , Issue.1 , pp. 175-222
    • Greenberg, Y.S.1
  • 20
    • 28044471169 scopus 로고    scopus 로고
    • Correction of concomitant gradient artifacts in experimental microtesla MRI
    • Myers W R, Möle M and Clarke J 2005 Correction of concomitant gradient artifacts in experimental microtesla MRI J. Magn. Reson. 177 274-84
    • (2005) J. Magn. Reson. , vol.177 , Issue.2 , pp. 274-284
    • Myers, W.R.1    Möle, M.2    Clarke, J.3
  • 21
  • 22
    • 26244462082 scopus 로고
    • Magnetoencephalography-theory, instrumentation, and applications to noninvasive studies of the working human brain
    • Hamalainen M, Hari R, Ilmoniemi R J, Knuutila J and Lounasmaa O V 1993 Magnetoencephalography-theory, instrumentation, and applications to noninvasive studies of the working human brain Rev. Mod. Phys. 65 413-97
    • (1993) Rev. Mod. Phys. , vol.65 , Issue.2 , pp. 413-497
    • Hamalainen, M.1    Hari, R.2    Ilmoniemi, R.J.3    Knuutila, J.4    Lounasmaa, O.V.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.