메뉴 건너뛰기




Volumn 15, Issue 2 PART I, 2005, Pages 635-639

SQUID-based simultaneous detection of NMR and biomagnetic signals at ultra-low magnetic fields

Author keywords

Bioniagnetism; Low magnetic field; MRI; NMR; SQUID

Indexed keywords

BIOELECTRIC PHENOMENA; CARDIOLOGY; ELECTROENCEPHALOGRAPHY; MAGNETIC FIELDS; MAGNETIC RESONANCE IMAGING; MEDICAL IMAGING; NEUROLOGY; NUCLEAR MAGNETIC RESONANCE; SIGNAL TO NOISE RATIO; SUPERCONDUCTING DEVICES;

EID: 22044449057     PISSN: 10518223     EISSN: None     Source Type: Journal    
DOI: 10.1109/TASC.2005.849978     Document Type: Conference Paper
Times cited : (30)

References (31)
  • 1
    • 0027200495 scopus 로고
    • Novel approaches to low cost MRI
    • A. Macovski and S. Conolly, "Novel approaches to low cost MRI,"Mag. Reson. Med., vol. 30, pp. 221-230, 1993.
    • (1993) Mag. Reson. Med. , vol.30 , pp. 221-230
    • Macovski, A.1    Conolly, S.2
  • 2
    • 0024988220 scopus 로고
    • NMR imaging in the earth's magnetic field
    • J. Stepišnic, V. Eržen, and M. Kos, "NMR imaging in the earth's magnetic field,"Mag. Reson. Med., vol. 15, pp. 386-391, 1990.
    • (1990) Mag. Reson. Med. , vol.15 , pp. 386-391
    • Stepišnic, J.1    Eržen, V.2    Kos, M.3
  • 3
    • 1342275177 scopus 로고
    • Nuclear magnetism of liquid systems in the earth field range
    • G. J. Bene, "Nuclear magnetism of liquid systems in the earth field range,"Phys. Reports, vol. 58, pp. 213-267, 1980.
    • (1980) Phys. Reports , vol.58 , pp. 213-267
    • Bene, G.J.1
  • 5
    • 0001064524 scopus 로고
    • Remote (inside-out) NMR. I. Remote production of a region of homogeneous magnetic field
    • R. K. Cooper and J. A. Jackson, "Remote (inside-out) NMR. I. Remote production of a region of homogeneous magnetic field,"J. Magn. Res., vol. 41, pp. 400-405, 1980.
    • (1980) J. Magn. Res. , vol.41 , pp. 400-405
    • Cooper, R.K.1    Jackson, J.A.2
  • 6
    • 0001064525 scopus 로고
    • Remote (inside-out) NMR. II. Sensitivity of NMR detection for external samples
    • L. J. Burnett and J. A. Jackson, "Remote (inside-out) NMR. II. Sensitivity of NMR detection for external samples,"J. Magn. Res., vol. 41, pp. 406-410, 1980.
    • (1980) J. Magn. Res. , vol.41 , pp. 406-410
    • Burnett, L.J.1    Jackson, J.A.2
  • 7
    • 0000138952 scopus 로고
    • Remote (inside-out) NMR. III. Detection of nuclear magnetic resonance in a remotely produced region of homogeneous magnetic field
    • J. A. Jackson, L. J. Burnett, and J. F. Harmon, "Remote (inside-out) NMR. III. Detection of nuclear magnetic resonance in a remotely produced region of homogeneous magnetic field,"J. Magn. Res., vol. 41, pp. 411-421, 1980.
    • (1980) J. Magn. Res. , vol.41 , pp. 411-421
    • Jackson, J.A.1    Burnett, L.J.2    Harmon, J.F.3
  • 9
    • 0037155596 scopus 로고    scopus 로고
    • Liquid-state NMR and scalar couplings in microtesla magnetic fields
    • R. McDermott, A. H. Trabesinger, M. Muck, E. L. Hahn, A. Pines, and J. Clarke, "Liquid-state NMR and scalar couplings in microtesla magnetic fields,"Science, vol. 295, pp. 2247-2249, 2002.
    • (2002) Science , vol.295 , pp. 2247-2249
    • McDermott, R.1    Trabesinger, A.H.2    Muck, M.3    Hahn, E.L.4    Pines, A.5    Clarke, J.6
  • 10
    • 0032418408 scopus 로고    scopus 로고
    • On- and off resonance spin-lock MT imaging of normal human brain at 0.1 T: Possibilities to modify image contrast
    • U. A. Ramadan, A. T. Markkola, J. Halavaara, J. Tanitu, A. M. Hakkinen, and H. J. Aronen, "On- and off resonance spin-lock MT imaging of normal human brain at 0.1 T: possibilities to modify image contrast,"Magn. Resonance Imag., vol. 16, pp. 1191-1199, 1998.
    • (1998) Magn. Resonance Imag. , vol.16 , pp. 1191-1199
    • Ramadan, U.A.1    Markkola, A.T.2    Halavaara, J.3    Tanitu, J.4    Hakkinen, A.M.5    Aronen, H.J.6
  • 13
    • 0000822131 scopus 로고    scopus 로고
    • Low-field magnetic resonance imaging with a high-Tc dc superconducting quantum interference device
    • K. Schlenga, R. F. McDermott, J. Clarke, R. E. de Souza, A. Wong-Foy, and A. Pines, "Low-field magnetic resonance imaging with a high-Tc dc superconducting quantum interference device,"Appl. Phys. Lett., vol. 75, pp. 3695-3697, 1999.
    • (1999) Appl. Phys. Lett. , vol.75 , pp. 3695-3697
    • Schlenga, K.1    McDermott, R.F.2    Clarke, J.3    De Souza, R.E.4    Wong-Foy, A.5    Pines, A.6
  • 15
    • 0031077639 scopus 로고    scopus 로고
    • A 4.2 K receiver coil and SQUID amplifier used to improve SNR of low-field magnetic resonance images of the human arm
    • H. C. Seton, J. M. S. Hutchison, and D. M. Busell, "A 4.2 K receiver coil and SQUID amplifier used to improve SNR of low-field magnetic resonance images of the human arm,"Meas. Sci. Technol., vol. 8, pp. 198-207, 1997.
    • (1997) Meas. Sci. Technol. , vol.8 , pp. 198-207
    • Seton, H.C.1    Hutchison, J.M.S.2    Busell, D.M.3
  • 16
    • 0031168008 scopus 로고    scopus 로고
    • A tuned SQUID amplifier for MRI based on a DOIT flux locked loop
    • H. C. Seton, J. M. S. Hutchison, and D. M. Bussell, "A tuned SQUID amplifier for MRI based on a DOIT flux locked loop,"IEEE Trans. Appl. Supercond., no. 7, pp. 3213-3216, 1997.
    • (1997) IEEE Trans. Appl. Supercond. , Issue.7 , pp. 3213-3216
    • Seton, H.C.1    Hutchison, J.M.S.2    Bussell, D.M.3
  • 17
    • 0029317772 scopus 로고
    • Broadband SQUID NMR with room-temperature samples
    • S. Kumar, B. D. Thorson, and W. F. Avrin, "Broadband SQUID NMR with room-temperature samples,"J. Mag. Resn., vol. B 107, pp. 252-259, 1995.
    • (1995) J. Mag. Resn. , vol.B 107 , pp. 252-259
    • Kumar, S.1    Thorson, B.D.2    Avrin, W.F.3
  • 18
    • 0030283613 scopus 로고    scopus 로고
    • NMR of room temperature samples with a flux-locked dc SQUID
    • S. Kumar, W. F. Avrin, and B. R. Whitecotton, "NMR of room temperature samples with a flux-locked dc SQUID,"IEEE Trans. Magn., vol. 32, pp. 5261-5264, 1996.
    • (1996) IEEE Trans. Magn. , vol.32 , pp. 5261-5264
    • Kumar, S.1    Avrin, W.F.2    Whitecotton, B.R.3
  • 20
    • 2942563757 scopus 로고    scopus 로고
    • SQUID-detected magnetic resonance imaging in microtesla magnetic fields
    • R. McDermott et al., "SQUID-detected magnetic resonance imaging in microtesla magnetic fields,"J. Low Temp. Phys., pp. 793-821, 135.
    • J. Low Temp. Phys. , vol.135 , pp. 793-821
    • McDermott, R.1
  • 21
    • 4243202770 scopus 로고    scopus 로고
    • Simultaneous magnetoencephalography and SQUID detected nuclear magnetic resonance in microtesla magnetic fields
    • P. Volegov et al., "Simultaneous magnetoencephalography and SQUID detected nuclear magnetic resonance in microtesla magnetic fields,"Mag. Reson. Med., vol. 52, pp. 467-470, 2004.
    • (2004) Mag. Reson. Med. , vol.52 , pp. 467-470
    • Volegov, P.1
  • 23
    • 0036267186 scopus 로고    scopus 로고
    • Toward direct mapping of neuronal activity: MRI detection of ultraweak transient magnetic field changes
    • J. Bodurka and P. A. Bandettini, "Toward direct mapping of neuronal activity: MRI detection of ultraweak transient magnetic field changes,"Mag. Reson. Med., vol. 47, pp. 1052-1058, 2002.
    • (2002) Mag. Reson. Med. , vol.47 , pp. 1052-1058
    • Bodurka, J.1    Bandettini, P.A.2
  • 24
    • 0042329673 scopus 로고    scopus 로고
    • Directly mapping magnetic field effects of neuronal activity by magnetic resonance imaging
    • J. Xiong, P. T. Fox, and J. H. Gao, "Directly mapping magnetic field effects of neuronal activity by magnetic resonance imaging,"Human Brain Mapping, vol. 20, pp. 41-49, 2003.
    • (2003) Human Brain Mapping , vol.20 , pp. 41-49
    • Xiong, J.1    Fox, P.T.2    Gao, J.H.3
  • 25
    • 22044449795 scopus 로고    scopus 로고
    • Instrumentation for simultaneous detection of low field NMR and biomagnetic signals
    • Jacksonville, FL, Oct. 4-8
    • A. N. Matlachov et al., "Instrumentation for simultaneous detection of low field NMR and biomagnetic signals,"presented at the ASC 2004, Jacksonville, FL, Oct. 4-8, 2004.
    • (2004) ASC 2004
    • Matlachov, A.N.1
  • 26
    • 26244462082 scopus 로고
    • Magnetoencephalography - Theory, instrumentation, and applications to noninvasive studies of the working human brain
    • M. Hämäläinen, R. Hari, R. J. Ilmoniemi, J. Knuutila, and O. V. Lounasmaa, "Magnetoencephalography - theory, instrumentation, and applications to noninvasive studies of the working human brain,"Rev. Mod. Phys., vol. 65, pp. 413-497, 1993.
    • (1993) Rev. Mod. Phys. , vol.65 , pp. 413-497
    • Hämäläinen, M.1    Hari, R.2    Ilmoniemi, R.J.3    Knuutila, J.4    Lounasmaa, O.V.5
  • 27
    • 4243122308 scopus 로고
    • A magnetic shielded room designed for magneto-encephalography
    • G. Sullivan, P. Lewis, J. S. George, and E. R. Flynn, "A magnetic shielded room designed for magneto-encephalography,"Rev. Sci. Inst., vol. 60, pp. 765-770, 1989.
    • (1989) Rev. Sci. Inst. , vol.60 , pp. 765-770
    • Sullivan, G.1    Lewis, P.2    George, J.S.3    Flynn, E.R.4
  • 28
    • 0035440247 scopus 로고    scopus 로고
    • Quantitative analysis of low-field NMR signals in the time domain
    • A. Nordon, P. J. Gemperline, C. A. McGill, and D. Littlejohn, "Quantitative analysis of low-field NMR signals in the time domain,"Anal. Chem., vol. 73, pp. 4286-4294, 2001.
    • (2001) Anal. Chem. , vol.73 , pp. 4286-4294
    • Nordon, A.1    Gemperline, P.J.2    McGill, C.A.3    Littlejohn, D.4
  • 29
    • 0035693977 scopus 로고    scopus 로고
    • Analysis of simulation experiments by bootstrap resampling
    • B. A. Peters, J. S. Smith, D. J. Medeiros, and M. W. Rohrer, Eds.
    • R. C. H. Cheng, "Analysis of simulation experiments by bootstrap resampling,"in Proc. 2001 Winter Simulation Conf., B. A. Peters, J. S. Smith, D. J. Medeiros, and M. W. Rohrer, Eds., 2001, Available: http://www.informs-cs.org/wsc01papers/021.PDF, pp. 179-186.
    • (2001) Proc. 2001 Winter Simulation Conf. , pp. 179-186
    • Cheng, R.C.H.1
  • 31
    • 0036651244 scopus 로고    scopus 로고
    • Toward rapid and unique curve resolution of low-field NMR relaxation data: Trilinear SLICING versus two-dimensional curve fitting
    • H. T. Pedersen, R. Bro, and S. B. Engelsen, "Toward rapid and unique curve resolution of low-field NMR relaxation data: trilinear SLICING versus two-dimensional curve fitting,"J. Magn. Res., vol. 157, pp. 141-155, 2002.
    • (2002) J. Magn. Res. , vol.157 , pp. 141-155
    • Pedersen, H.T.1    Bro, R.2    Engelsen, S.B.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.