메뉴 건너뛰기




Volumn 177, Issue 2, 2005, Pages 274-284

Correction of concomitant gradient artifacts in experimental microtesla MRI

Author keywords

Concomitant gradient; Field cycling; Low field; Magnetic resonance imaging; Phase correction

Indexed keywords

BANDWIDTH; COMPUTER SIMULATION; ENCODING (SYMBOLS); MAGNETIC FIELD EFFECTS; MAGNETOMETERS; PROTONS; SAMPLING; SQUIDS;

EID: 28044471169     PISSN: 10907807     EISSN: 10960856     Source Type: Journal    
DOI: 10.1016/j.jmr.2005.08.003     Document Type: Article
Times cited : (27)

References (30)
  • 1
    • 0010999095 scopus 로고
    • Relaxation-time measurement and imaging in the earth's magnetic field
    • G. Planinsic, J. Stepisink, and M. Kos Relaxation-time measurement and imaging in the earth's magnetic field J. Magn. Reson. A 110 1994 170
    • (1994) J. Magn. Reson. A , vol.110 , pp. 170
    • Planinsic, G.1    Stepisink, J.2    Kos, M.3
  • 8
    • 0032050952 scopus 로고    scopus 로고
    • Low field magnetic resonance images of polarized noble gases obtained with a dc superconducting quantum interference device
    • M.P. Augustine, A. Wong-Foy, J.L. Yarger, M. Tomaselli, A. Pines, D.M. TonThat, and J. Clarke Low field magnetic resonance images of polarized noble gases obtained with a dc superconducting quantum interference device Appl. Phys. Lett. 72 1998 1908
    • (1998) Appl. Phys. Lett. , vol.72 , pp. 1908
    • Augustine, M.P.1    Wong-Foy, A.2    Yarger, J.L.3    Tomaselli, M.4    Pines, A.5    Tonthat, D.M.6    Clarke, J.7
  • 15
    • 0025364499 scopus 로고
    • Concomitant magnetic field gradients and their effects on imaging at low magnetic field strengths
    • D.G. Norris, and J.M.S. Hutchison Concomitant magnetic field gradients and their effects on imaging at low magnetic field strengths Magn. Reson. Imaging 8 1990 33
    • (1990) Magn. Reson. Imaging , vol.8 , pp. 33
    • Norris, D.G.1    Hutchison, J.M.S.2
  • 16
    • 17644399479 scopus 로고    scopus 로고
    • Image artifacts in very low magnetic field MRI: The role of concomitant gradients
    • D.A. Yablonskiy, A.L. Sukstanskii, and J.J.H. Ackerman Image artifacts in very low magnetic field MRI: the role of concomitant gradients J. Magn. Reson. 174 2005 279
    • (2005) J. Magn. Reson. , vol.174 , pp. 279
    • Yablonskiy, D.A.1    Sukstanskii, A.L.2    Ackerman, J.J.H.3
  • 17
    • 28044442137 scopus 로고
    • Reduction of the concomitant field gradient effects by main magnetic field alteration
    • T. Classen-Vujcic, J. Slotboom, and A.F. Mehlkopf Reduction of the concomitant field gradient effects by main magnetic field alteration Proc. Soc. Magn. Reson. 3 1995 56
    • (1995) Proc. Soc. Magn. Reson. , vol.3 , pp. 56
    • Classen-Vujcic, T.1    Slotboom, J.2    Mehlkopf, A.F.3
  • 19
    • 13844315466 scopus 로고    scopus 로고
    • Zero- to low-field MRI with averaging of concomitant gradient fields
    • C.A. Meriles, D. Sakellariou, A.H. Trabesinger, V. Demas, and A. Pines Zero- to low-field MRI with averaging of concomitant gradient fields PNAS 102 2005 1840
    • (2005) PNAS , vol.102 , pp. 1840
    • Meriles, C.A.1    Sakellariou, D.2    Trabesinger, A.H.3    Demas, V.4    Pines, A.5
  • 23
    • 0036723586 scopus 로고    scopus 로고
    • Correction of concomitant magnetic field-induced image artifacts in nonaxial echo-planar imaging
    • Y.P. Du, X.J. Zhou, and M.A. Bernstein Correction of concomitant magnetic field-induced image artifacts in nonaxial echo-planar imaging Magn. Reson. Med. 48 2002 509
    • (2002) Magn. Reson. Med. , vol.48 , pp. 509
    • Du, Y.P.1    Zhou, X.J.2    Bernstein, M.A.3
  • 27
    • 0025221905 scopus 로고
    • Nuclear relaxation of human brain gray and white matter: Analysis of field dependence and implications for MRI
    • H.W. Fischer, P.A. Rinck, Y. van Haverbeke, and R.N. Muller Nuclear relaxation of human brain gray and white matter: analysis of field dependence and implications for MRI Magn. Reson. Med. 16 1990 317
    • (1990) Magn. Reson. Med. , vol.16 , pp. 317
    • Fischer, H.W.1    Rinck, P.A.2    Van Haverbeke, Y.3    Muller, R.N.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.