메뉴 건너뛰기




Volumn , Issue , 2007, Pages 1076-1079

Affine-corrected PARADISE: Free-breathing patient-adaptive cardiac MRI with sensitivity encoding

Author keywords

Adaptive acquisition; Affine motion correction; Dynamic MRI; Respiratory motion; Time sequential sampling

Indexed keywords

IMAGE ACQUISITION; PATIENT MONITORING; REAL TIME SYSTEMS; SENSITIVITY ANALYSIS;

EID: 36348959007     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/ISBI.2007.357042     Document Type: Conference Paper
Times cited : (8)

References (8)
  • 1
    • 33750934590 scopus 로고    scopus 로고
    • Optimal multi-channel timesequential acquisition in dynamic MRI with parallel coils
    • Apr
    • Behzad Sharif and Yoram Bresler, "Optimal multi-channel timesequential acquisition in dynamic MRI with parallel coils," in Proc. IEEE ISBI, Apr. 2006, pp. 45 - 48.
    • (2006) Proc. IEEE ISBI , pp. 45-48
    • Sharif, B.1    Bresler, Y.2
  • 2
    • 0032712873 scopus 로고    scopus 로고
    • SENSE: Sensitivity encoding for fast MRI
    • K. P. Pruessmann et al., "SENSE: Sensitivity encoding for fast MRI," Mag. Res. in Medicine, vol. 42, pp. 952-962, 1999.
    • (1999) Mag. Res. in Medicine , vol.42 , pp. 952-962
    • Pruessmann, K.P.1
  • 3
    • 84948655755 scopus 로고    scopus 로고
    • Spatio-temporal modeling and minimum, redundancy adaptive acquisition in dynamic MRI
    • July
    • Nitin Aggarwal, Qi Zhao, and Yoram Bresler, "Spatio-temporal modeling and minimum, redundancy adaptive acquisition in dynamic MRI," in Proc. IEEEISBI, Arlington, VA, July 2002, pp. 737-740.
    • (2002) Proc. IEEEISBI, Arlington, VA , pp. 737-740
    • Aggarwal, N.1    Zhao, Q.2    Bresler, Y.3
  • 5
    • 0036770501 scopus 로고    scopus 로고
    • K. McLeish K, D.L. Hill, D. Atkinson, J.M. Blackall, and R. Razavi, A study of the motion and deformation of the heart due to respiration, IEEE Trans Med Imaging, 21, pp. 1142-50, Sep 2002.
    • K. McLeish K, D.L. Hill, D. Atkinson, J.M. Blackall, and R. Razavi, "A study of the motion and deformation of the heart due to respiration," IEEE Trans Med Imaging, vol. 21, pp. 1142-50, Sep 2002.
  • 6
    • 0037587240 scopus 로고    scopus 로고
    • Novel prospective respiratory motion correction approach for free-breathing coronary MR angiography using a patient-adapted affine motion model
    • Jul
    • D. Manke, K. Nehrke, and P. Bornert, "Novel prospective respiratory motion correction approach for free-breathing coronary MR angiography using a patient-adapted affine motion model," Magn Reson Med., vol. 50, pp. 122-31, Jul 2003.
    • (2003) Magn Reson Med , vol.50 , pp. 122-131
    • Manke, D.1    Nehrke, K.2    Bornert, P.3
  • 7
    • 0030826830 scopus 로고    scopus 로고
    • Lattice-theoretic analysis of timesequential sampling of spatio-temporal signals - part I
    • January
    • N. P. Willis and Y. Bresler, "Lattice-theoretic analysis of timesequential sampling of spatio-temporal signals - part I," IEEE Trans. Information Theory, pp. 190-207, January 1997.
    • (1997) IEEE Trans. Information Theory , pp. 190-207
    • Willis, N.P.1    Bresler, Y.2
  • 8
    • 0033343646 scopus 로고    scopus 로고
    • A realistic spline-based dynamic heart phantom
    • W.P. Segars et al., "A realistic spline-based dynamic heart phantom," IEEE Trans. Nucl Sci., vol. 46, pp. 503-506, 1999.
    • (1999) IEEE Trans. Nucl Sci , vol.46 , pp. 503-506
    • Segars, W.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.