메뉴 건너뛰기




Volumn 6554, Issue , 2007, Pages

Investigations of intraband quantum cascade laser source for a MEMS-scale photoacoustic sensor

Author keywords

Chemical sensor; Microelectromechanical systems; Photoacoustics; Piezoelectrics

Indexed keywords

DIMETHYL METHYL PHOSPHONATE (DMMP); INTERBAND QUANTUM CASCADE LASER (ICL); TRACE GAS MEASUREMENTS;

EID: 35948980040     PISSN: 0277786X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.722278     Document Type: Conference Paper
Times cited : (14)

References (15)
  • 1
    • 84885752992 scopus 로고    scopus 로고
    • A NATION CHALLENGED: A MEDICAL MYSTERY; Second Case of Anthrax Leads F.B.I. Into Inquiry,
    • October 9
    • D. Canedy and A. Kuczynski, "A NATION CHALLENGED: A MEDICAL MYSTERY; Second Case of Anthrax Leads F.B.I. Into Inquiry," New York Times, October 9 2001
    • (2001) New York Times
    • Canedy, D.1    Kuczynski, A.2
  • 2
    • 35948987740 scopus 로고    scopus 로고
    • Suicide Bombers Using Chlorine Gas Kill 2 and Sicken Hundreds in Western Iraq,
    • March 18
    • K. Semple, "Suicide Bombers Using Chlorine Gas Kill 2 and Sicken Hundreds in Western Iraq," NewYork Times, March 18, 2007.
    • (2007) NewYork Times
    • Semple, K.1
  • 3
    • 0346685331 scopus 로고    scopus 로고
    • Mobile laser spectrometer with novel resonant multipass photoacoustic cell for trace-gas sensing
    • M. Nägele, M.W. Sigrist, "Mobile laser spectrometer with novel resonant multipass photoacoustic cell for trace-gas sensing," Appl. Phys. B 70, pp. 895-901 (2001).
    • (2001) Appl. Phys. B , vol.70 , pp. 895-901
    • Nägele, M.1    Sigrist, M.W.2
  • 4
    • 0000023288 scopus 로고    scopus 로고
    • Geometrical optimization of a longitudinal photoacoustic cell for a sensitive and fast trace gas detection
    • F.G.C. Bijnen, J. Reuss, and F. J.M. Harren, "Geometrical optimization of a longitudinal photoacoustic cell for a sensitive and fast trace gas detection, " Rev. Sci. Instrum. 67, pp. 2914-2933 (1996).
    • (1996) Rev. Sci. Instrum , vol.67 , pp. 2914-2933
    • Bijnen, F.G.C.1    Reuss, J.2    Harren, F.J.M.3
  • 5
    • 0000434556 scopus 로고    scopus 로고
    • Performance-Characteristics of a Real-Time Direct Deposition Gas-Chromatography Fourier-Transform Infrared Spectrometry System
    • S. Bourne, A. M. Haefner, K. L. Norton and P. R Griffiths, "Performance-Characteristics of a Real-Time Direct Deposition Gas-Chromatography Fourier-Transform Infrared Spectrometry System," Analytical Chemistry, 62 (22), 2448-2452
    • Analytical Chemistry , vol.62 , Issue.22 , pp. 2448-2452
    • Bourne, S.1    Haefner, A.M.2    Norton, K.L.3    Griffiths, P.R.4
  • 6
    • 24944581604 scopus 로고    scopus 로고
    • Reduction of detection limits of the direct deposition GC/FT-IR interface by surface-enhanced infrared absorption
    • D. A. Heaps and P. R. Griffiths, "Reduction of detection limits of the direct deposition GC/FT-IR interface by surface-enhanced infrared absorption," Analytical Chemistry, 77 (18), 5965-5972
    • Analytical Chemistry , vol.77 , Issue.18 , pp. 5965-5972
    • Heaps, D.A.1    Griffiths, P.R.2
  • 7
    • 28444465579 scopus 로고    scopus 로고
    • Off-line direct deposition gas chromatography/surface-enhanced Raman scattering and the ramifications for on-line measurements
    • D. A. Heaps and P. R. Griffiths, "Off-line direct deposition gas chromatography/surface-enhanced Raman scattering and the ramifications for on-line measurements," Applied Spectroscopy, 59 (11), 1305-1309
    • Applied Spectroscopy , vol.59 , Issue.11 , pp. 1305-1309
    • Heaps, D.A.1    Griffiths, P.R.2
  • 8
    • 33747463535 scopus 로고    scopus 로고
    • D. A. Heaps and P. Pellegrino Examination of Quantum Cascade Laser Source for a MEMS-scale Photoacoustic Chemical Sensor, SPIE Chemical and Biological Sensing VII, 6218,621805-1-9 (2006)
    • D. A. Heaps and P. Pellegrino "Examination of Quantum Cascade Laser Source for a MEMS-scale Photoacoustic Chemical Sensor," SPIE Chemical and Biological Sensing VII, Vol. 6218,621805-1-9 (2006)
  • 11
    • 0035368936 scopus 로고    scopus 로고
    • Miniaturization and Integration of Photoacoustic Detection with a Microfabricated Chemical Reactor System
    • S.L. Firebaugh, K.F. Jensen, and M. A. Schmidt, "Miniaturization and Integration of Photoacoustic Detection with a Microfabricated Chemical Reactor System," JMEMS, 10, pp 232-237, (2001).
    • (2001) JMEMS , vol.10 , pp. 232-237
    • Firebaugh, S.L.1    Jensen, K.F.2    Schmidt, M.A.3
  • 12
    • 0036678378 scopus 로고    scopus 로고
    • Miniaturization and integration of photoacoustic detection
    • S.L. Firebaugh, K.F. Jensen, and M.A. Schmidt, "Miniaturization and integration of photoacoustic detection," J. Appl. Phys. 92, pp.1555-1563 (2002).
    • (2002) J. Appl. Phys , vol.92 , pp. 1555-1563
    • Firebaugh, S.L.1    Jensen, K.F.2    Schmidt, M.A.3
  • 14
    • 0038547117 scopus 로고    scopus 로고
    • Microfaricated Preconcentrator-Focuser for a Microscale Gas Chromatography
    • W. Tian, S. W. Pang, C. Lu and E. T. Zellers, "Microfaricated Preconcentrator-Focuser for a Microscale Gas Chromatography," JMEMS. 12, 264-272
    • JMEMS , vol.12 , pp. 264-272
    • Tian, W.1    Pang, S.W.2    Lu, C.3    Zellers, E.T.4
  • 15
    • 22444451077 scopus 로고    scopus 로고
    • Multiple-Stage Microfabricated Preconcentrator-Focuser for Micro Gas Chromatography System
    • W. Tian, H. K. L. Chan, C. Lu, S. W. Pang and E. T. Zellers, "Multiple-Stage Microfabricated Preconcentrator-Focuser for Micro Gas Chromatography System," JMEMS, 14, 498-507
    • JMEMS , vol.14 , pp. 498-507
    • Tian, W.1    Chan, H.K.L.2    Lu, C.3    Pang, S.W.4    Zellers, E.T.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.