-
1
-
-
0028398052
-
Estimation of the effective self-diffusion tensor from the NMR spin echo
-
Mar
-
P. J. Basser, J. Mattiello, and D. LeBihan, "Estimation of the effective self-diffusion tensor from the NMR spin echo," J. Magn. Reson., B, vol. 103, pp. 247-254, Mar. 1994.
-
(1994)
J. Magn. Reson., B
, vol.103
, pp. 247-254
-
-
Basser, P.J.1
Mattiello, J.2
LeBihan, D.3
-
2
-
-
0033859469
-
Age-related decline in brain white matter anisotropy measured with spatially correlated echo-planar diffusion tensor imaging
-
A. Pfefferbaum, E. V. Sullivan, M. Hedehus, K. O. Lim, E. Adalsteinsson, and M. Moseley, "Age-related decline in brain white matter anisotropy measured with spatially correlated echo-planar diffusion tensor imaging," Magn. Reson. Med., vol. 44, pp. 259-268, 2000.
-
(2000)
Magn. Reson. Med
, vol.44
, pp. 259-268
-
-
Pfefferbaum, A.1
Sullivan, E.V.2
Hedehus, M.3
Lim, K.O.4
Adalsteinsson, E.5
Moseley, M.6
-
3
-
-
0035964210
-
Evidence of cortical disconnection as a mechanism of age-related cognitive decline
-
Sep
-
M. O'Sullivan, D. K. Jones, P. E. Summers, R. G. Morris, S. C. R. Williams, and H. S. Markus, "Evidence of cortical disconnection as a mechanism of age-related cognitive decline," Neurology, vol. 57, pp. 632-638, Sep. 2001.
-
(2001)
Neurology
, vol.57
, pp. 632-638
-
-
O'Sullivan, M.1
Jones, D.K.2
Summers, P.E.3
Morris, R.G.4
Williams, S.C.R.5
Markus, H.S.6
-
4
-
-
0036869345
-
Applications of diffusion-weighted and diffusion tensor MRI to white matter deseases - a review
-
Nov
-
M. A. Horsfield and D. K. Jones, "Applications of diffusion-weighted and diffusion tensor MRI to white matter deseases - a review," NMR Biomed., vol. 15, pp. 570-577, Nov. 2002.
-
(2002)
NMR Biomed
, vol.15
, pp. 570-577
-
-
Horsfield, M.A.1
Jones, D.K.2
-
5
-
-
0033786160
-
In vivo fiber tractography using DT-MRI data
-
P. Basser, S. Pajevic, C. Pierpaoli, J. Duda, and A. Aldroubi, "In vivo fiber tractography using DT-MRI data," Magn. Reson. Med., vol. 44, no. 4, pp. 625-632, 2000.
-
(2000)
Magn. Reson. Med
, vol.44
, Issue.4
, pp. 625-632
-
-
Basser, P.1
Pajevic, S.2
Pierpaoli, C.3
Duda, J.4
Aldroubi, A.5
-
6
-
-
0036868662
-
Fiber tracking:principles and strategies - A technical review
-
Nov
-
S. Mori and P. C. M. van Zijl, "Fiber tracking:principles and strategies - A technical review," NMR Biomed., vol. 15, pp. 468-480, Nov. 2002.
-
(2002)
NMR Biomed
, vol.15
, pp. 468-480
-
-
Mori, S.1
van Zijl, P.C.M.2
-
7
-
-
0033025847
-
The reduction of the sorting bias in the eigenvalues of the diffusion tensor
-
Jul
-
K. M. Martin, N. G. Papadakis, C. L. H. Huang, L. D. Hall, and T. A. Carpenter, "The reduction of the sorting bias in the eigenvalues of the diffusion tensor," Magn. Reson. Imag., vol. 17, pp. 893-901, Jul. 1999.
-
(1999)
Magn. Reson. Imag
, vol.17
, pp. 893-901
-
-
Martin, K.M.1
Papadakis, N.G.2
Huang, C.L.H.3
Hall, L.D.4
Carpenter, T.A.5
-
8
-
-
0033945138
-
Statistical artifacts in diffusion tensor MRI (DT-MRI) caused by background noise
-
Jul
-
P. J. Basser and S. Pajevic, "Statistical artifacts in diffusion tensor MRI (DT-MRI) caused by background noise," Magn. Reson. Med., vol. 44, pp. 41-50, Jul. 2000.
-
(2000)
Magn. Reson. Med
, vol.44
, pp. 41-50
-
-
Basser, P.J.1
Pajevic, S.2
-
9
-
-
0029908076
-
Toward a quantitative assessment of diffusion anisotropy
-
Dec
-
C. Pierpaoli and P. J. Basser, "Toward a quantitative assessment of diffusion anisotropy," Magn. Reson. Med., vol. 36, pp. 893-906, Dec. 1996.
-
(1996)
Magn. Reson. Med
, vol.36
, pp. 893-906
-
-
Pierpaoli, C.1
Basser, P.J.2
-
10
-
-
0031732550
-
A theoretical study of the effect of experimental noise on the measurement of anisotropy in diffusion imaging
-
Sep
-
M. E. Bastin, P. A. Armitage, and I. Marshall, "A theoretical study of the effect of experimental noise on the measurement of anisotropy in diffusion imaging," Magn. Reson. Imag., vol. 16, pp. 773-785, Sep. 1998.
-
(1998)
Magn. Reson. Imag
, vol.16
, pp. 773-785
-
-
Bastin, M.E.1
Armitage, P.A.2
Marshall, I.3
-
11
-
-
0025226022
-
Magn. Reson. Med
-
Nov
-
P. B. Roemer, W. A. Edelstrein, C. E. Hayes, S. P. Souza, and O. M. Mueller, Magn. Reson. Med. "The NMR phased array," Nov. 1990, vol. 16, no. 2, pp. 192-225.
-
(1990)
The NMR phased array
, vol.16
, Issue.2
, pp. 192-225
-
-
Roemer, P.B.1
Edelstrein, W.A.2
Hayes, C.E.3
Souza, S.P.4
Mueller, O.M.5
-
12
-
-
22744435455
-
64-channel array coil for single echo acquisition magnetic resonance imaging
-
Aug
-
M. P. McDougall and S. M. Wright, "64-channel array coil for single echo acquisition magnetic resonance imaging," Magn. Reson. Med., vol. 54, pp. 386-392, Aug. 2005.
-
(2005)
Magn. Reson. Med
, vol.54
, pp. 386-392
-
-
McDougall, M.P.1
Wright, S.M.2
-
13
-
-
33745685594
-
32-channel 3 testa receive-only phased-array head coil with soccer-ball element geometry
-
Jul
-
G. C. Wiggins, C. Triantafyllou, A. Potthast, A. Reykowski, M. Nittka, and L. L. Wald, "32-channel 3 testa receive-only phased-array head coil with soccer-ball element geometry," Magn. Reson. Med., vol. 56, pp. 216-223, Jul. 2006.
-
(2006)
Magn. Reson. Med
, vol.56
, pp. 216-223
-
-
Wiggins, G.C.1
Triantafyllou, C.2
Potthast, A.3
Reykowski, A.4
Nittka, M.5
Wald, L.L.6
-
14
-
-
0030982409
-
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radio frequency coil arrays
-
Oct
-
D. K. Sodickson and W. J. Manning, "Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radio frequency coil arrays," Magn. Reson. Med., vol. 38, no. 4, pp. 591-603, Oct. 1997.
-
(1997)
Magn. Reson. Med
, vol.38
, Issue.4
, pp. 591-603
-
-
Sodickson, D.K.1
Manning, W.J.2
-
15
-
-
0032712873
-
SENSE: Sensitivity encoding for fast MRI
-
Nov
-
K. P. Pruessmann, M. Weiger, M. B. Scheidegger, and P. Boesiger, "SENSE: Sensitivity encoding for fast MRI,"Magn. Reson. Med., vol. 42, pp. 952-962, Nov. 1999.
-
(1999)
Magn. Reson. Med
, vol.42
, pp. 952-962
-
-
Pruessmann, K.P.1
Weiger, M.2
Scheidegger, M.B.3
Boesiger, P.4
-
16
-
-
0041492763
-
SNR-optimality of sum-of-squares reconstruction for phased-array magnetic resonance imaging
-
Jul
-
E. G. Larsson, D. Erdogmus, R. Yan, J. C. Prindpe, and J. R. Fitzsimmons, "SNR-optimality of sum-of-squares reconstruction for phased-array magnetic resonance imaging," J. Magn. Reson., vol. 163, pp. 121-123, Jul. 2003.
-
(2003)
J. Magn. Reson
, vol.163
, pp. 121-123
-
-
Larsson, E.G.1
Erdogmus, D.2
Yan, R.3
Prindpe, J.C.4
Fitzsimmons, J.R.5
-
17
-
-
0034060592
-
Adaptive reconstruction of phased array MR imagery
-
May
-
D. O. Walsh, A. F. Gmitro, and M. W. Marcelliri, "Adaptive reconstruction of phased array MR imagery," Magn. Reson. Med., vol. 43, pp. 682-690, May 2000.
-
(2000)
Magn. Reson. Med
, vol.43
, pp. 682-690
-
-
Walsh, D.O.1
Gmitro, A.F.2
Marcelliri, M.W.3
-
18
-
-
0036187917
-
Combination, of signals from array coils using image-based estimation of coil sensitivity profiles
-
Mar
-
M. Bydder, D. J. Larkman, and J. V. Hajnal, "Combination, of signals from array coils using image-based estimation of coil sensitivity profiles," Magn. Reson. Med., vol. 47, pp. 539-548, Mar. 2002.
-
(2002)
Magn. Reson. Med
, vol.47
, pp. 539-548
-
-
Bydder, M.1
Larkman, D.J.2
Hajnal, J.V.3
-
19
-
-
0035105014
-
Noise correction for the exact determination of apparent diffusion coefficients at low SNR
-
Mar
-
O. Dietrich, S. Heiland, and K. Sartor, "Noise correction for the exact determination of apparent diffusion coefficients at low SNR," Magn. Reson. Med., vol. 45, pp. 448-453, Mar. 2001.
-
(2001)
Magn. Reson. Med
, vol.45
, pp. 448-453
-
-
Dietrich, O.1
Heiland, S.2
Sartor, K.3
-
20
-
-
7544247899
-
Squashing peanuts and smashing pumpkins: How noise distorts diffusion-weighted MR data
-
Nov
-
D. K. Jones and P. J. Basser, "Squashing peanuts and smashing pumpkins: How noise distorts diffusion-weighted MR data," Magn. Reson. Med., vol. 52, no. 5, pp. 979-993, Nov. 2004.
-
(2004)
Magn. Reson. Med
, vol.52
, Issue.5
, pp. 979-993
-
-
Jones, D.K.1
Basser, P.J.2
-
21
-
-
3242805968
-
Image construction methods for phased array magnetic resonance imaging
-
Aug
-
D. Erdogmus, R. Van, E. G. Larsson, J. C. Principe, and J. R. Fitzsimmons, "Image construction methods for phased array magnetic resonance imaging," J. Magn. Reson. Imag., vol. 20, pp. 306-314, Aug. 2004.
-
(2004)
J. Magn. Reson. Imag
, vol.20
, pp. 306-314
-
-
Erdogmus, D.1
Van, R.2
Larsson, E.G.3
Principe, J.C.4
Fitzsimmons, J.R.5
-
22
-
-
35648968352
-
Adaptive combination of phased array signals for diffusion imaging
-
T. Benner, V. Jellus, R. Wang, V.J. Wedeen, A. J. van der Kouwe, G. C. Wiggins, and A. G. Sorensen, "Adaptive combination of phased array signals for diffusion imaging," in Proc. Int. Soc. Magn. Reson. Med., 2006, p. 1026.
-
(2006)
Proc. Int. Soc. Magn. Reson. Med
, pp. 1026
-
-
Benner, T.1
Jellus, V.2
Wang, R.3
Wedeen, V.J.4
van der Kouwe, A.J.5
Wiggins, G.C.6
Sorensen, A.G.7
-
23
-
-
0003454712
-
-
New York: Wiley
-
M. E. Haacke, R. W. Brown, M. R. Thompson, and R. Vankatesan, Magnetic Resonance Imaging, Physical Principles and Sequence Design. New York: Wiley, 1999.
-
(1999)
Magnetic Resonance Imaging, Physical Principles and Sequence Design
-
-
Haacke, M.E.1
Brown, R.W.2
Thompson, M.R.3
Vankatesan, R.4
-
24
-
-
35648987378
-
-
J. Sijbers, Signal and noise estimation from magnetic resonance images, Ph.D. dissertation, Univ. Antwerp, Antwerp, Belgium, 1999.
-
J. Sijbers, "Signal and noise estimation from magnetic resonance images," Ph.D. dissertation, Univ. Antwerp, Antwerp, Belgium, 1999.
-
-
-
-
25
-
-
0030726766
-
Signal-to-noise measurements in magnitude images from NMR phased arrays
-
Nov
-
C. D. Constantinides, E. Atalar, and E. R. McVeigh, "Signal-to-noise measurements in magnitude images from NMR phased arrays," Magn. Reson. Med., vol. 38, pp. 852-857, Nov. 1997.
-
(1997)
Magn. Reson. Med
, vol.38
, pp. 852-857
-
-
Constantinides, C.D.1
Atalar, E.2
McVeigh, E.R.3
-
27
-
-
0036209364
-
In vivo mapping of the fast and slow diffusion tensors in human brain
-
A. C. Clark, M. Hedehus, and M. E. Moseley, "In vivo mapping of the fast and slow diffusion tensors in human brain," Magn. Reson. Med., vol. 47, pp. 623-628, 2002.
-
(2002)
Magn. Reson. Med
, vol.47
, pp. 623-628
-
-
Clark, A.C.1
Hedehus, M.2
Moseley, M.E.3
-
28
-
-
0842287530
-
Biexponential diffusion tensor analysis of human brain diffusion data
-
S. E. Maier, S. Vajapeyam, H. Mamata, C. F. Westin, F. A. Jolesz, and R. V. Mulkern, "Biexponential diffusion tensor analysis of human brain diffusion data," Magn. Reson. Med., vol. 51, pp. 321-330, 2004.
-
(2004)
Magn. Reson. Med
, vol.51
, pp. 321-330
-
-
Maier, S.E.1
Vajapeyam, S.2
Mamata, H.3
Westin, C.F.4
Jolesz, F.A.5
Mulkern, R.V.6
-
29
-
-
0030162959
-
Microstructural and physiological features of tissues elucidated by quantitative diffusion tensor MRI
-
Jan
-
P. J. Basser and C. Pierpaoli, "Microstructural and physiological features of tissues elucidated by quantitative diffusion tensor MRI," J. Magn. Reson., B, vol. 111, pp. 209-219, Jan. 1996.
-
(1996)
J. Magn. Reson., B
, vol.111
, pp. 209-219
-
-
Basser, P.J.1
Pierpaoli, C.2
-
30
-
-
35648960026
-
-
J. W. Tukey, Ann. Math. Stat. Bias and confidence in not quite large samples, Jun. 1956, 29, p. 614.
-
J. W. Tukey, Ann. Math. Stat. "Bias and confidence in not quite large samples," Jun. 1956, vol. 29, p. 614.
-
-
-
-
31
-
-
0037227848
-
Determining and visualizing uncertainty in estimates of fiber orientation from diffusion tensor MRI
-
D. Jones, "Determining and visualizing uncertainty in estimates of fiber orientation from diffusion tensor MRI," Magn. Reson. Med., vol. 49, no. 1, pp. 7-12, 2003.
-
(2003)
Magn. Reson. Med
, vol.49
, Issue.1
, pp. 7-12
-
-
Jones, D.1
-
32
-
-
0036869232
-
Diffusion-tensor MRI: Theory, experimental design and data analysis - A technical review
-
Nov
-
P. J. Basser and D. K. Jones, "Diffusion-tensor MRI: Theory, experimental design and data analysis - A technical review," NMR Biomed., vol. 15, no. 7-8, pp. 456-467, Nov. 2002.
-
(2002)
NMR Biomed
, vol.15
, Issue.7-8
, pp. 456-467
-
-
Basser, P.J.1
Jones, D.K.2
-
33
-
-
0041702764
-
Parametric and non-parametric statistical analysis of DT-MRI data
-
Mar
-
S. Pajevic and P. J. Basser, "Parametric and non-parametric statistical analysis of DT-MRI data," J. Magn. Reson., vol. 161, no. 1, pp. 1-14, Mar. 2003.
-
(2003)
J. Magn. Reson
, vol.161
, Issue.1
, pp. 1-14
-
-
Pajevic, S.1
Basser, P.J.2
-
34
-
-
4243093951
-
Assessing DTI data quality using bootstrap analysis
-
Sept
-
S. Heim, K. Hahn, P. G. Samann, L. Fahrmeir, and D. P. Auer, "Assessing DTI data quality using bootstrap analysis," Magn. Reson. Med., vol. 52, pp. 582-589, Sept. 2004.
-
(2004)
Magn. Reson. Med
, vol.52
, pp. 582-589
-
-
Heim, S.1
Hahn, K.2
Samann, P.G.3
Fahrmeir, L.4
Auer, D.P.5
-
35
-
-
33749243100
-
Comparison of bootstrap approaches for estimation of uncertainties in DTI parameters
-
Nov
-
S. Chung, Y. LU, and R. G. Henry, "Comparison of bootstrap approaches for estimation of uncertainties in DTI parameters," NeuroImage, vol. 33, pp. 531-541, Nov. 2006.
-
(2006)
NeuroImage
, vol.33
, pp. 531-541
-
-
Chung, S.1
LU, Y.2
Henry, R.G.3
|