메뉴 건너뛰기




Volumn 179, Issue 9, 2007, Pages 925-931

Methodological aspects of functional neuroimaging at high field strength: A critical review;Methodische aspekte der funktionellen neurobildgebung im MRT-hochfeldbereich: Eine kritische übersicht

Author keywords

Brain; High field strength; MR functional imaging; Review; Technical aspects

Indexed keywords

ARTIFACT; CONTRAST; COST; FUNCTIONAL MAGNETIC RESONANCE IMAGING; HUMAN; METHODOLOGY; NEUROIMAGING; NOISE; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; RADIATION FIELD; RADIODIAGNOSTIC EQUIPMENT AND SUPPLIES; REVIEW; SIGNAL NOISE RATIO; STRUCTURE ACTIVITY RELATION; BRAIN; CLUSTER ANALYSIS; COMPARATIVE STUDY; FORECASTING; IMAGE PROCESSING; INSTRUMENTATION; PHYSIOLOGY; REST; SENSITIVITY AND SPECIFICITY; THEORETICAL MODEL;

EID: 35148886688     PISSN: 14389029     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-2007-963195     Document Type: Review
Times cited : (12)

References (51)
  • 1
    • 20844461556 scopus 로고    scopus 로고
    • MR-basierte Methoden der funktionellen Bildgebung des zentralen Nervensystems
    • Giesel FL, Wustenberg T, Bongers A et al. MR-basierte Methoden der funktionellen Bildgebung des zentralen Nervensystems. Fortschr Röntgenstr 2005; 177: 714-730
    • (2005) Fortschr Röntgenstr , vol.177 , pp. 714-730
    • Giesel, F.L.1    Wustenberg, T.2    Bongers, A.3
  • 2
    • 84858360726 scopus 로고    scopus 로고
    • MR-Methoden für funktionelle Untersuchungen des Gehirns. 86. Deutscher Röntgenkongress
    • Heiland S. MR-Methoden für funktionelle Untersuchungen des Gehirns. 86. Deutscher Röntgenkongress. Fortschr Röntgenstr 2005; 177: S324
    • (2005) Fortschr Röntgenstr , vol.177
    • Heiland, S.1
  • 3
    • 84858347909 scopus 로고    scopus 로고
    • nd. International Symposium Highfield MR in Clinical Applications. Fortschr Röntgenstr 2004; 176: 433
    • nd. International Symposium "Highfield MR in Clinical Applications". Fortschr Röntgenstr 2004; 176: 433
  • 4
    • 84858369359 scopus 로고    scopus 로고
    • Rekonstruktion intraoperativer Elektroden-Grids zum direkten Vergleich funktioneller MR-Ergebnisse mit intraoperativer Stimulation. 85. Deutscher Röntgenkongress
    • Scheef L, Neuloh G, Brockmöller T et al. Rekonstruktion intraoperativer Elektroden-Grids zum direkten Vergleich funktioneller MR-Ergebnisse mit intraoperativer Stimulation. 85. Deutscher Röntgenkongress. Fortschr Röntgenstr 2004; 176: S159
    • (2004) Fortschr Röntgenstr , vol.176
    • Scheef, L.1    Neuloh, G.2    Brockmöller, T.3
  • 5
    • 0036181865 scopus 로고    scopus 로고
    • Functional magnetic resonance imaging: Physiological background, technical aspects and prerequisites for clinical use
    • Stippich C, Heiland S, Tronnier V et al. Functional magnetic resonance imaging: Physiological background, technical aspects and prerequisites for clinical use. Fortschr Röntgenstr 2002; 174: 43-49
    • (2002) Fortschr Röntgenstr , vol.174 , pp. 43-49
    • Stippich, C.1    Heiland, S.2    Tronnier, V.3
  • 6
    • 28044459646 scopus 로고    scopus 로고
    • Präoperatives Mapping der Sprachareale mittels funktioneller Magnetresonanztomographie (fMRT) bei Patienten mit Hirntumoren: Paradigmenvergleich
    • Prothmann S, Puccini S, Dalitz B et al. Präoperatives Mapping der Sprachareale mittels funktioneller Magnetresonanztomographie (fMRT) bei Patienten mit Hirntumoren: Paradigmenvergleich. Fortschr Röntgenstr 2005; 177: 1522-1531
    • (2005) Fortschr Röntgenstr , vol.177 , pp. 1522-1531
    • Prothmann, S.1    Puccini, S.2    Dalitz, B.3
  • 7
    • 20844444964 scopus 로고    scopus 로고
    • Clinical highfield MR
    • Schild H. Clinical highfield MR. Fortschr Röntgenstr 2005; 177: 621-623
    • (2005) Fortschr Röntgenstr , vol.177 , pp. 621-623
    • Schild, H.1
  • 8
    • 24144448806 scopus 로고    scopus 로고
    • T1, T2 relaxation and magnetization transfer in tissue at 3T
    • Stanisz GJ, Odrobina EE, Pun J et al. T1, T2 relaxation and magnetization transfer in tissue at 3T. Magn Reson Med 2005; 54: 507-512
    • (2005) Magn Reson Med , vol.54 , pp. 507-512
    • Stanisz, G.J.1    Odrobina, E.E.2    Pun, J.3
  • 9
    • 18044385764 scopus 로고    scopus 로고
    • Comparison of physiological noise at 1.5 T, 3 T and 7 T and optimization of fMRI acquisition parameters
    • Triantafyllou C, Hoge RD, Krueger G et al. Comparison of physiological noise at 1.5 T, 3 T and 7 T and optimization of fMRI acquisition parameters. Neuroimage 2005; 26: 243-250
    • (2005) Neuroimage , vol.26 , pp. 243-250
    • Triantafyllou, C.1    Hoge, R.D.2    Krueger, G.3
  • 10
    • 0035091609 scopus 로고    scopus 로고
    • Neuroimaging at 1.5 T and 3.0 T: Comparison of oxygenation-sensitive magnetic resonance imaging
    • Kruger G, Kastrup A, Glover GH. Neuroimaging at 1.5 T and 3.0 T: comparison of oxygenation-sensitive magnetic resonance imaging. Magn Reson Med 2001; 45: 595-604
    • (2001) Magn Reson Med , vol.45 , pp. 595-604
    • Kruger, G.1    Kastrup, A.2    Glover, G.H.3
  • 11
    • 0025630001 scopus 로고
    • Brain magnetic resonance imaging with contrast dependent on blood oxygenation
    • Ogawa S, Lee TM, Kay AR et al. Brain magnetic resonance imaging with contrast dependent on blood oxygenation. Proc Natl Acad Sci U S A 1990; 87: 9868-9872
    • (1990) Proc Natl Acad Sci U S A , vol.87 , pp. 9868-9872
    • Ogawa, S.1    Lee, T.M.2    Kay, A.R.3
  • 12
    • 0027513370 scopus 로고
    • Functional mapping of the human visual cortex at 4 and 1.5 tesla using deoxygenation contrast EPI
    • Turner R, Jezzard P, Wen H et al. Functional mapping of the human visual cortex at 4 and 1.5 tesla using deoxygenation contrast EPI. Magn Reson Med 1993; 29: 277-279
    • (1993) Magn Reson Med , vol.29 , pp. 277-279
    • Turner, R.1    Jezzard, P.2    Wen, H.3
  • 13
    • 0030753056 scopus 로고    scopus 로고
    • Experimental determination of the BOLD field strength dependence in vessels and tissue
    • Gati JS, Menon RS, Ugurbil K et al. Experimental determination of the BOLD field strength dependence in vessels and tissue. Magn Reson Med 1997; 38: 296-302
    • (1997) Magn Reson Med , vol.38 , pp. 296-302
    • Gati, J.S.1    Menon, R.S.2    Ugurbil, K.3
  • 14
    • 0037397680 scopus 로고    scopus 로고
    • Comparison of fMRI activation at 3 and 1.5 T during perceptual, cognitive, and affective processing
    • Krasnow B, Tamm L, Greicius MD et al. Comparison of fMRI activation at 3 and 1.5 T during perceptual, cognitive, and affective processing. Neuroimage 2003; 18: 813-826
    • (2003) Neuroimage , vol.18 , pp. 813-826
    • Krasnow, B.1    Tamm, L.2    Greicius, M.D.3
  • 15
    • 20444472447 scopus 로고    scopus 로고
    • Comparison of fMRI activation as measured with gradient- and spin-echo EPI during visual perception
    • Schmidt CF, Boesiger P, Ishai A. Comparison of fMRI activation as measured with gradient- and spin-echo EPI during visual perception. Neuroimage 2005; 26: 852-859
    • (2005) Neuroimage , vol.26 , pp. 852-859
    • Schmidt, C.F.1    Boesiger, P.2    Ishai, A.3
  • 16
    • 0034839919 scopus 로고    scopus 로고
    • Spiral-in/out BOLD fMRI for increased SNR and reduced susceptibility artifacts
    • Glover GH, Law CS. Spiral-in/out BOLD fMRI for increased SNR and reduced susceptibility artifacts. Magn Reson Med 2001; 46: 515-522
    • (2001) Magn Reson Med , vol.46 , pp. 515-522
    • Glover, G.H.1    Law, C.S.2
  • 17
    • 0031932352 scopus 로고    scopus 로고
    • Self-navigated spiral fMRI: Interleaved versus singleshot
    • Glover GH, Lai S. Self-navigated spiral fMRI: interleaved versus singleshot. Magn Reson Med 1998; 39: 361-368
    • (1998) Magn Reson Med , vol.39 , pp. 361-368
    • Glover, G.H.1    Lai, S.2
  • 18
    • 0345600048 scopus 로고    scopus 로고
    • Multishot partial-k-space EPI for high-resolution fMRI demonstrated in a rat whisker barrel stimulation model at 3T
    • Lu H, Mazaheri Y, Zhang R et al. Multishot partial-k-space EPI for high-resolution fMRI demonstrated in a rat whisker barrel stimulation model at 3T. Magn Reson Med 2003; 50: 1215-1222
    • (2003) Magn Reson Med , vol.50 , pp. 1215-1222
    • Lu, H.1    Mazaheri, Y.2    Zhang, R.3
  • 19
    • 0027494434 scopus 로고
    • A functional MRI technique combining principles of echo-shifting with a train of observations (PRESTO)
    • Liu G, Sobering G, Duyn J et al. A functional MRI technique combining principles of echo-shifting with a train of observations (PRESTO). Magn Reson Med 1993; 30: 764-768
    • (1993) Magn Reson Med , vol.30 , pp. 764-768
    • Liu, G.1    Sobering, G.2    Duyn, J.3
  • 20
    • 0032189299 scopus 로고    scopus 로고
    • Phase navigator correction in 3D fMRI improves detection of brain activation: Quantitative assessment with a graded motor activation procedure
    • Ramsey NF, van den Brink JS, van Muiswinkel AM et al. Phase navigator correction in 3D fMRI improves detection of brain activation: quantitative assessment with a graded motor activation procedure. Neuroimage 1998; 8: 240-248
    • (1998) Neuroimage , vol.8 , pp. 240-248
    • Ramsey, N.F.1    van den Brink, J.S.2    van Muiswinkel, A.M.3
  • 21
    • 0141506077 scopus 로고    scopus 로고
    • A PRESTO-SENSE sequence with alternating partial-Fourier encoding for rapid susceptibility-weighted 3D MRI time series
    • Klarhofer M, Dilharreguy B, van Gelderen GP et al. A PRESTO-SENSE sequence with alternating partial-Fourier encoding for rapid susceptibility-weighted 3D MRI time series. Magn Reson Med 2003; 50: 830-838
    • (2003) Magn Reson Med , vol.50 , pp. 830-838
    • Klarhofer, M.1    Dilharreguy, B.2    van Gelderen, G.P.3
  • 22
  • 23
    • 0033778650 scopus 로고    scopus 로고
    • Acoustic noise during functional magnetic resonance imaging
    • Ravicz ME, Melcher JR, Kiang NY. Acoustic noise during functional magnetic resonance imaging. J Acoust Soc Am 2000; 108: 1683-1696
    • (2000) J Acoust Soc Am , vol.108 , pp. 1683-1696
    • Ravicz, M.E.1    Melcher, J.R.2    Kiang, N.Y.3
  • 24
    • 1542374685 scopus 로고    scopus 로고
    • Relationship between magnetic field strength and magnetic-resonance-related acoustic noise levels
    • Moelker A, Wielopolski PA, Pattynama PM. Relationship between magnetic field strength and magnetic-resonance-related acoustic noise levels. MAGMA 2003; 16: 52-55
    • (2003) MAGMA , vol.16 , pp. 52-55
    • Moelker, A.1    Wielopolski, P.A.2    Pattynama, P.M.3
  • 25
    • 0029784613 scopus 로고    scopus 로고
    • The effect of intense acoustic stimulation on basilar-membrane vibrations
    • Ruggero MA, Rich NC, Redo A. The effect of intense acoustic stimulation on basilar-membrane vibrations. Auditory Neuroscience 1996; 2: 329-345
    • (1996) Auditory Neuroscience , vol.2 , pp. 329-345
    • Ruggero, M.A.1    Rich, N.C.2    Redo, A.3
  • 26
    • 0035213020 scopus 로고    scopus 로고
    • Active conti ol of the volume acquisition noise in functional magnetic resonance imaging: Method and psychoacoustical evaluation
    • Chambers J, Akeroyd MA, Summerfield AQ et al. Active conti ol of the volume acquisition noise in functional magnetic resonance imaging: method and psychoacoustical evaluation. J Acoust Soc Am 2001; 110: 3041-3054
    • (2001) J Acoust Soc Am , vol.110 , pp. 3041-3054
    • Chambers, J.1    Akeroyd, M.A.2    Summerfield, A.Q.3
  • 27
    • 18244379330 scopus 로고    scopus 로고
    • Active-passive gradient shielding for MRl acoustic noise reduction
    • Edelstein WA, Kidane TK, Taracila V et al. Active-passive gradient shielding for MRl acoustic noise reduction. Magn Reson Med 2005; 53: 1013-1017
    • (2005) Magn Reson Med , vol.53 , pp. 1013-1017
    • Edelstein, W.A.1    Kidane, T.K.2    Taracila, V.3
  • 28
    • 84858351472 scopus 로고    scopus 로고
    • rd International Symposium on Highfield MR in Clinical Applications. Fortschr Röntgenstr 2006; 178: 115-127
    • rd International Symposium on Highfield MR in Clinical Applications. Fortschr Röntgenstr 2006; 178: 115-127
  • 30
    • 0036263907 scopus 로고    scopus 로고
    • Generalized autocalibrating partially parallel acquisitions (GRAPPA)
    • Griswold MA, Jakob PM, Heidemann RM et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002; 47: 1202-1210
    • (2002) Magn Reson Med , vol.47 , pp. 1202-1210
    • Griswold, M.A.1    Jakob, P.M.2    Heidemann, R.M.3
  • 31
    • 35348992506 scopus 로고    scopus 로고
    • Hermans EJ, Neggers SF, Ramsey NF. Ultra-fast three dimensional PRESTO-SENSE imaging with full btain coverage on a clinical 3T scanner. 12th Annual Meeting of Organization of Human Brain Mapping. Neuroimage 2006; 31: 197
    • Hermans EJ, Neggers SF, Ramsey NF. Ultra-fast three dimensional PRESTO-SENSE imaging with full btain coverage on a clinical 3T scanner. 12th Annual Meeting of Organization of Human Brain Mapping. Neuroimage 2006; 31: 197
  • 32
    • 0034089499 scopus 로고    scopus 로고
    • PRESTO-SENSE: An ultrafast whole-brain fMRI technique
    • Golay X, Pruessmann KP, Weiger M et al. PRESTO-SENSE: an ultrafast whole-brain fMRI technique. Magn Reson Med 2000; 43: 779-786
    • (2000) Magn Reson Med , vol.43 , pp. 779-786
    • Golay, X.1    Pruessmann, K.P.2    Weiger, M.3
  • 33
    • 10044235365 scopus 로고    scopus 로고
    • Reduction of magnetic field inhomogeneity artifacts in echo planar imaging with SENSE and GESEPI at high field
    • Yang QX, Wang J, Smith MB et al. Reduction of magnetic field inhomogeneity artifacts in echo planar imaging with SENSE and GESEPI at high field. Magn Reson Med 2004; 52: 1418-1423
    • (2004) Magn Reson Med , vol.52 , pp. 1418-1423
    • Yang, Q.X.1    Wang, J.2    Smith, M.B.3
  • 34
    • 33744530416 scopus 로고    scopus 로고
    • Accelerated parallel imaging for functional imaging of the human brain
    • de Zwart JA, van Gelderen F, Golay X et al. Accelerated parallel imaging for functional imaging of the human brain. NMR Biomed 2006; 19: 342-351
    • (2006) NMR Biomed , vol.19 , pp. 342-351
    • de Zwart, J.A.1    van Gelderen, F.2    Golay, X.3
  • 35
    • 0036892919 scopus 로고    scopus 로고
    • Application of sensitivity-encoded echo-planar imaging for blood oxygen level-dependent functional brain imaging
    • de Zwart JA, van Gelderen P, Kellman P et al. Application of sensitivity-encoded echo-planar imaging for blood oxygen level-dependent functional brain imaging. Magn Reson Med 2002; 48: 1011-1020
    • (2002) Magn Reson Med , vol.48 , pp. 1011-1020
    • de Zwart, J.A.1    van Gelderen, P.2    Kellman, P.3
  • 36
    • 0042738956 scopus 로고    scopus 로고
    • Functional MRI using sensitivity-encoded echo planar imaging (SENSE-EPI)
    • Preibisch C, Pilatus U, Bunke J et al. Functional MRI using sensitivity-encoded echo planar imaging (SENSE-EPI). Neuroimage 2003; 19: 412-421
    • (2003) Neuroimage , vol.19 , pp. 412-421
    • Preibisch, C.1    Pilatus, U.2    Bunke, J.3
  • 37
    • 33744538123 scopus 로고    scopus 로고
    • Potential and feasibility of parallel MRI at high field
    • Wiesinger F, Van de Moortele PF, Adriany G et al. Potential and feasibility of parallel MRI at high field. NMR Biomed 2006; 19: 368-378
    • (2006) NMR Biomed , vol.19 , pp. 368-378
    • Wiesinger, F.1    Van de Moortele, P.F.2    Adriany, G.3
  • 38
    • 0242385481 scopus 로고    scopus 로고
    • Ultimate intrinsic signal-to-noise ratio for parallel MRI: Electromagnetic field considerations
    • Obliger MA, Grant AK, Sodickson DK. Ultimate intrinsic signal-to-noise ratio for parallel MRI: electromagnetic field considerations. Magn Reson Med 2003; 50: 1018-1030
    • (2003) Magn Reson Med , vol.50 , pp. 1018-1030
    • Obliger, M.A.1    Grant, A.K.2    Sodickson, D.K.3
  • 39
    • 0025783488 scopus 로고
    • (Gradient- and spin-echo) imaging: A novel fast MRI technique
    • Oshio K, Feinberg DA. GRASE (Gradient- and spin-echo) imaging: a novel fast MRI technique. Magn Reson Med 1991; 20: 344-349
    • (1991) Magn Reson Med , vol.20 , pp. 344-349
    • Oshio, K.1    Feinberg DA, G.R.A.S.E.2
  • 40
    • 0028387214 scopus 로고
    • Spin-echo and gradientecho EPI of human brain activation using BOLD contrast: A comparative study at 1.5 T
    • Bandettini PA, Wong EC, Jesmanowicz A et al. Spin-echo and gradientecho EPI of human brain activation using BOLD contrast: a comparative study at 1.5 T. NMR Biomed 1994; 7: 12-20
    • (1994) NMR Biomed , vol.7 , pp. 12-20
    • Bandettini, P.A.1    Wong, E.C.2    Jesmanowicz, A.3
  • 41
    • 0036334757 scopus 로고    scopus 로고
    • An investigation of the value of spin-echo-based fMRI using a Stroop color-word matching task and EPI at 3 T
    • Norris DG, Zysset S, Mildner T et al. An investigation of the value of spin-echo-based fMRI using a Stroop color-word matching task and EPI at 3 T. Neuroimage 2002; 15: 719-726
    • (2002) Neuroimage , vol.15 , pp. 719-726
    • Norris, D.G.1    Zysset, S.2    Mildner, T.3
  • 42
    • 11844267212 scopus 로고    scopus 로고
    • Signal and noise characteristics of Hahn SE and GE BOLD fMRI at 7 T in humans
    • Vacoub E, Van de Moortele PF, Shmuel A et al. Signal and noise characteristics of Hahn SE and GE BOLD fMRI at 7 T in humans. Neuroimage 2005; 24: 738-750
    • (2005) Neuroimage , vol.24 , pp. 738-750
    • Vacoub, E.1    Van de Moortele, P.F.2    Shmuel, A.3
  • 43
    • 31044443991 scopus 로고    scopus 로고
    • Combined imaging-histological study of cortical laminar specificity of fMRI signals
    • Harel N, Lin J, Moeller S et al. Combined imaging-histological study of cortical laminar specificity of fMRI signals. Neuroimage 2006; 29: 879-887
    • (2006) Neuroimage , vol.29 , pp. 879-887
    • Harel, N.1    Lin, J.2    Moeller, S.3
  • 44
    • 13844266851 scopus 로고    scopus 로고
    • Functional 3.0-T MR assessment of higher cognitive function: Are there advantages over 1.5-T imaging?
    • Hoenig K, Kuhl CK, Scheef L. Functional 3.0-T MR assessment of higher cognitive function: are there advantages over 1.5-T imaging? Radiology 2005; 234: 860-868
    • (2005) Radiology , vol.234 , pp. 860-868
    • Hoenig, K.1    Kuhl, C.K.2    Scheef, L.3
  • 45
    • 0032776472 scopus 로고    scopus 로고
    • Comparison of 3D BOLD functional MRI with spiral acquisition at 1.5 and 4.0 T
    • Yang Y, Wen H, Mattay VS et al. Comparison of 3D BOLD functional MRI with spiral acquisition at 1.5 and 4.0 T. Neuroimage 1999; 9: 446-451
    • (1999) Neuroimage , vol.9 , pp. 446-451
    • Yang, Y.1    Wen, H.2    Mattay, V.S.3
  • 46
    • 0347595449 scopus 로고    scopus 로고
    • EPI-BOLD fMRI of human motor cortex at 1.5 T and 3.0 T: Sensitivity dependence on echo time and acquisition bandwidth
    • Fera F, Yongbi MN, van Gelderen P et al. EPI-BOLD fMRI of human motor cortex at 1.5 T and 3.0 T: sensitivity dependence on echo time and acquisition bandwidth. J Magn Reson Imaging 2004; 19: 19-26
    • (2004) J Magn Reson Imaging , vol.19 , pp. 19-26
    • Fera, F.1    Yongbi, M.N.2    van Gelderen, P.3
  • 48
    • 0032790895 scopus 로고    scopus 로고
    • The sensory somatotopic map of the human hand demonstrated at 4 Tesla
    • Maldjian JA, Gottschalk A, Patel RS et al. The sensory somatotopic map of the human hand demonstrated at 4 Tesla. Neuroimage 1999; 10: 55-62
    • (1999) Neuroimage , vol.10 , pp. 55-62
    • Maldjian, J.A.1    Gottschalk, A.2    Patel, R.S.3
  • 49
    • 5644275046 scopus 로고    scopus 로고
    • Distributed digit somatotopy in primary somatosensory cortex
    • Overduin SA, Servos P. Distributed digit somatotopy in primary somatosensory cortex. Neuroimage 2004; 23: 462-472
    • (2004) Neuroimage , vol.23 , pp. 462-472
    • Overduin, S.A.1    Servos, P.2
  • 50
    • 0030991503 scopus 로고    scopus 로고
    • Ocular dominance in human V1 demonstrated by functional magnetic resonance imaging
    • Menon RS, Ogawa S, Strupp JP et al. Ocular dominance in human V1 demonstrated by functional magnetic resonance imaging. J Neurophysiol 1997; 77: 2780-2787
    • (1997) J Neurophysiol , vol.77 , pp. 2780-2787
    • Menon, R.S.1    Ogawa, S.2    Strupp, J.P.3
  • 51
    • 27744517277 scopus 로고    scopus 로고
    • Reproducibility of functional MR imaging: Preliminary results of prospective multi-institutional study performed by Biomedical Informatics Research Network
    • Zou KH, Greve DN, Wang M et al. Reproducibility of functional MR imaging: preliminary results of prospective multi-institutional study performed by Biomedical Informatics Research Network. Radiology 2005; 237: 781-789
    • (2005) Radiology , vol.237 , pp. 781-789
    • Zou, K.H.1    Greve, D.N.2    Wang, M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.