메뉴 건너뛰기




Volumn 6510, Issue PART 3, 2007, Pages

A simple all-digital PET system

Author keywords

Front end electronics; Peripheral connect interface; Positron emission tomography; Time to digital converter

Indexed keywords

CALIBRATION; DATA ACQUISITION; MULTIPLEXING; OPTIMIZATION; SIGNAL ANALYSIS;

EID: 35148842615     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.713846     Document Type: Conference Paper
Times cited : (8)

References (15)
  • 1
    • 33744493093 scopus 로고    scopus 로고
    • The new era in cancer research
    • H. Varmus, "The new era in cancer research," Science 312, pp. 1162-1165, 2006.
    • (2006) Science , vol.312 , pp. 1162-1165
    • Varmus, H.1
  • 2
    • 33744487875 scopus 로고    scopus 로고
    • Molecular imaging in cancer
    • R. Weissleder, "Molecular imaging in cancer," Science 312, pp. 1168-1171, 2006.
    • (2006) Science , vol.312 , pp. 1168-1171
    • Weissleder, R.1
  • 3
    • 0035838997 scopus 로고    scopus 로고
    • R. d. 1. Fuente-Fernandez, T. J. Ruth, V. Sossi, M. Schulzer, D. B. Calne, and A. J. Stoessl, Expectation and dopamine release: Mechanism of the placebo effect in parkinson's disease, Science 293, pp. 1164-1166, 2001.
    • R. d. 1. Fuente-Fernandez, T. J. Ruth, V. Sossi, M. Schulzer, D. B. Calne, and A. J. Stoessl, "Expectation and dopamine release: Mechanism of the placebo effect in parkinson's disease," Science 293, pp. 1164-1166, 2001.
  • 4
    • 0027181321 scopus 로고    scopus 로고
    • K. Herholz, D. Perani, E. Salmon, G. Franck, F. Fazio, W. D. Heiss, and C. D., Comparability of fdg pet studies in probable alzheimer's disease, Nuclear Medicine, The Journal of 34, pp. 1460-1466, 1993.
    • K. Herholz, D. Perani, E. Salmon, G. Franck, F. Fazio, W. D. Heiss, and C. D., "Comparability of fdg pet studies in probable alzheimer's disease," Nuclear Medicine, The Journal of 34, pp. 1460-1466, 1993.
  • 5
    • 2342525914 scopus 로고    scopus 로고
    • L. Mosconi, A. Pupi, T. R. D. Cristofaro, M. Fayyaz, S. Sorbi, and K. Herholz, Functional interactions of the entorhinal cortex: An 18f-fdg pet study on normal aging and alzheimer's disease, Nuclear Medicine, The Journal of 45, pp. 382-392, 2004.
    • L. Mosconi, A. Pupi, T. R. D. Cristofaro, M. Fayyaz, S. Sorbi, and K. Herholz, "Functional interactions of the entorhinal cortex: An 18f-fdg pet study on normal aging and alzheimer's disease," Nuclear Medicine, The Journal of 45, pp. 382-392, 2004.
  • 9
    • 0034245290 scopus 로고    scopus 로고
    • Fpga based front-end electronics for a high resolution pet scanner
    • J. W. Young, J. C., Moyers, and M. Lenox, "Fpga based front-end electronics for a high resolution pet scanner," Nuclear Science, IEEE Transactions on 47, pp. 1676-1680, 2000.
    • (2000) Nuclear Science, IEEE Transactions on , vol.47 , pp. 1676-1680
    • Young, J.W.1    Moyers, J.C.2    Lenox, M.3
  • 11
    • 27644437977 scopus 로고    scopus 로고
    • A new approach for pulse processing in positron emission tomography
    • Q. Xie, C. M. Kao, Z. Hsiau, and C. T. Chen, "A new approach for pulse processing in positron emission tomography," Nuclear Science, IEEE Transactions on 52, pp. 988-995, 2005.
    • (2005) Nuclear Science, IEEE Transactions on , vol.52 , pp. 988-995
    • Xie, Q.1    Kao, C.M.2    Hsiau, Z.3    Chen, C.T.4
  • 12
    • 23844522578 scopus 로고    scopus 로고
    • A preliminary experimental validation of a new approach for pulse processing in pet
    • 3
    • Q. Xie, C.-M. Kao, and C.-T. Chen, "A preliminary experimental validation of a new approach for pulse processing in pet," in Nuclear Science Symposium Conference Record, 2004 IEEE, 3, pp. 1428-1431 Vol. 3, 2004.
    • (2004) Nuclear Science Symposium Conference Record, 2004 IEEE , vol.3 , pp. 1428-1431
    • Xie, Q.1    Kao, C.-M.2    Chen, C.-T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.