메뉴 건너뛰기




Volumn 53, Issue 3, 2006, Pages 784-788

Real time digital signal processing implementation for an APD-based PET scanner with phoswich detectors

Author keywords

Avalanche photodiodes (apds); Field programmable gate array (fpga); Positron emission tomography (pet); Real time digital signal processing

Indexed keywords

AVALANCHE PHOTODIODES (APDS); REAL TIME DIGITAL SIGNAL PROCESSING; TIMESTAMP ALGORITHMS; VECTOR QUANTIZATION THEORY;

EID: 33746383470     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2006.875441     Document Type: Article
Times cited : (37)

References (26)
  • 1
    • 0030169128 scopus 로고    scopus 로고
    • Initial results from the sherbrooke APD positron tomograph
    • Jun.
    • R. Lecomte, "Initial results from the Sherbrooke APD positron tomograph," IEEE Trans. Nucl. Sci, vol. 43, no. 3, pp. 1952-1957, Jun. 1996.
    • (1996) IEEE Trans. Nucl. Sci. , vol.43 , Issue.3 , pp. 1952-1957
    • Lecomte, R.1
  • 2
    • 0033349350 scopus 로고    scopus 로고
    • A novel APD-based detector module for multi-modality PET/SPECT/CT scanners
    • Jun.
    • A. Saoudi and R. Lecomte, "A novel APD-based detector module for multi-modality PET/SPECT/CT scanners," IEEE Trans. Nucl. Sci., vol. 46, no. 3, pp. 479-484, Jun. 1999.
    • (1999) IEEE Trans. Nucl. Sci. , vol.46 , Issue.3 , pp. 479-484
    • Saoudi, A.1    Lecomte, R.2
  • 3
    • 0034206973 scopus 로고    scopus 로고
    • A depth encoding scintillation detector unit with a position-sensitive photomultiplier tube
    • Murayama, "A depth encoding scintillation detector unit with a position-sensitive photomultiplier tube," IEEE Trans. Nud. Sci., vol. 47, pp. 1045-1050, 2000.
    • (2000) IEEE Trans. Nud. Sci. , vol.47 , pp. 1045-1050
    • Murayama1
  • 4
    • 0029358347 scopus 로고
    • A room temperature LSO/PIN photodiode PET detector module that measures depth of interaction
    • Aug.
    • W. Moses, "A room temperature LSO/PIN photodiode PET detector module that measures depth of interaction," IEEE Trans. Nucl. Sci, vol. 42, no. 4, pp. 1085-1089, Aug. 1995.
    • (1995) IEEE Trans. Nucl. Sci , vol.42 , Issue.4 , pp. 1085-1089
    • Moses, W.1
  • 5
    • 0142241142 scopus 로고    scopus 로고
    • Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET
    • M. Streun, "Pulse shape discrimination of LSO and LuYAP scintillators for depth of interaction detection in PET," in IEEE NSS/MIC Conf. Rec., 2002, vol. 3, pp. 1636-1639.
    • (2002) IEEE NSS/MIC Conf. Rec. , vol.3 , pp. 1636-1639
    • Streun, M.1
  • 6
    • 23844548307 scopus 로고    scopus 로고
    • Experimental results of identification and vector quantization algorithms for DOI measurement in digital PET scanners with phoswich detectors
    • Rome, Italy, Oct
    • J.-B. Michaud, "Experimental results of identification and vector quantization algorithms for DOI measurement in digital PET scanners with phoswich detectors," presented at the IEEE NSS/MIC Conf., Rome, Italy, Oct 2004.
    • (2004) IEEE NSS/MIC Conf.
    • Michaud, J.-B.1
  • 7
    • 33746374426 scopus 로고    scopus 로고
    • The data acquisition system of ClearPET Neuro - A small animal PET scanner
    • Jun.
    • M. Streun, G. Brandenburg, H. Larue, C. Perl, and K. Ziemons, "The data acquisition system of ClearPET Neuro - A small animal PET scanner," IEEE Trans. Nucl. Sci., vol. 53, no. 3, pp. 700-704, Jun. 2006.
    • (2006) IEEE Trans. Nucl. Sci. , vol.53 , Issue.3 , pp. 700-704
    • Streun, M.1    Brandenburg, G.2    Larue, H.3    Perl, C.4    Ziemons, K.5
  • 8
    • 84858912274 scopus 로고    scopus 로고
    • Real-time digital coincidence detection system for high resolution APD-based animal PET scanner
    • Oct.
    • M.-A. Tétrault, "Real-time digital coincidence detection system for high resolution APD-based animal PET scanner," in Proc. NSS/MIC 2005, Oct. 2005.
    • (2005) Proc. NSS/MIC 2005
    • Tétrault, M.-A.1
  • 9
    • 23844542164 scopus 로고    scopus 로고
    • Preliminary results of a mixed signal data acquisition sub-system for a distributed, digital, computational, APD-based, dualmodality PET/CT architecture for small animal imaging
    • Rome, Italy, Oct
    • R. Fontaine, "Preliminary results of a mixed signal data acquisition sub-system for a distributed, digital, computational, APD-based, dualmodality PET/CT architecture for small animal imaging," presented at the IEEE NSS/MIC Conf., Rome, Italy, Oct 2004.
    • (2004) IEEE NSS/MIC Conf.
    • Fontaine, R.1
  • 13
    • 11844271473 scopus 로고    scopus 로고
    • Time determination of BGO-APD detecton by digital signal processing for positron emission tomography
    • Portland, OR, Oct
    • J.-D. Leroux, "Time determination of BGO-APD detecton by digital signal processing for positron emission tomography," presented at the IEEE NSS/MIC Conf., Portland, OR, Oct 2003.
    • (2003) IEEE NSS/MIC Conf.
    • Leroux, J.-D.1
  • 14
    • 23844472383 scopus 로고    scopus 로고
    • Time discrimination techniques using artificial neural networks for positron emission tomography
    • Rome, Italy, Oct.
    • J.-D. Leroux, "Time discrimination techniques using artificial neural networks for positron emission tomography," presented at the IEEE NSS/MIC Conf., Rome, Italy, Oct. 2004.
    • (2004) IEEE NSS/MIC Conf.
    • Leroux, J.-D.1
  • 15
    • 10744231688 scopus 로고    scopus 로고
    • Study of spatial resolution and depth of interaction of APD-based PET detector modules using light sharing schemes
    • Oct.
    • R. Bruyndonckx, S. Leonard, J. Liu, S. Tavernier, P. Szupryczynski, and A. Fedorov, "Study of spatial resolution and depth of interaction of APD-based PET detector modules using light sharing schemes," IEEE Trans. Nucl. Sci., vol. 50, no. 5, pp. 1415-1419, Oct. 2003.
    • (2003) IEEE Trans. Nucl. Sci. , vol.50 , Issue.5 , pp. 1415-1419
    • Bruyndonckx, R.1    Leonard, S.2    Liu, J.3    Tavernier, S.4    Szupryczynski, P.5    Fedorov, A.6
  • 16
    • 4644326237 scopus 로고    scopus 로고
    • Performance measurements of a depth-encoding PET detector module based on position-sensitive avalanche photodiode read-out
    • P. A. Dokhale, "Performance measurements of a depth-encoding PET detector module based on position-sensitive avalanche photodiode read-out," Phys. Med. Biol., vol. 49, no. 18, pp. 4293-4304, 2004.
    • (2004) Phys. Med. Biol. , vol.49 , Issue.18 , pp. 4293-4304
    • Dokhale, P.A.1
  • 17
    • 0035552777 scopus 로고    scopus 로고
    • A depth-of-interaction detector for PET with GSO crystals doped with different amounts of Ce
    • N. Inadama, "A depth-of-interaction detector for PET with GSO crystals doped with different amounts of Ce," Proc. IEEE NSS/MIC, pp. M.2-M.3, 2001.
    • (2001) Proc. IEEE NSS/MIC
    • Inadama, N.1
  • 18
    • 2942751670 scopus 로고
    • A new dual crystal depth sensitive detector for high resolution PET cameras
    • R. Lecomte, "A new dual crystal depth sensitive detector for high resolution PET cameras," J. Nucl. Med., vol. 27. p. 974, 1986.
    • (1986) J. Nucl. Med. , vol.27 , pp. 974
    • Lecomte, R.1
  • 19
    • 0032142529 scopus 로고    scopus 로고
    • Depth of interaction for PET using segmented crystals
    • Aug.
    • L. R. MacDonald and M. Dahlbom, "Depth of interaction for PET using segmented crystals," IEEE Trans. Nucl. Sci., vol. 45, no. 4, pp. 2144-2148, Aug. 1998.
    • (1998) IEEE Trans. Nucl. Sci. , vol.45 , Issue.4 , pp. 2144-2148
    • MacDonald, L.R.1    Dahlbom, M.2
  • 20
    • 0023161642 scopus 로고
    • A preliminary evaluation of a dual crystal positron camera
    • S. Holte, H. Ostertag, and M. Kesselberg, "A preliminary evaluation of a dual crystal positron camera," J. Comput. Assist, Tomogr., vol. 11, no. 4. pp. 691-697, 1987.
    • (1987) J. Comput. Assist, Tomogr. , vol.11 , Issue.4 , pp. 691-697
    • Holte, S.1    Ostertag, H.2    Kesselberg, M.3
  • 22
    • 0033311839 scopus 로고    scopus 로고
    • Depth identification accuracy of a three layer phoswich PET detector module
    • Jun.
    • J. Seidel, J. J. Vaquero, S. Siegel, W. R. Gandler, and M. V. Green, "Depth identification accuracy of a three layer phoswich PET detector module," IEEE Trans. Nucl. Sci., vol. 46, no. 3, pp. 485-490, Jun. 1999.
    • (1999) IEEE Trans. Nucl. Sci. , vol.46 , Issue.3 , pp. 485-490
    • Seidel, J.1    Vaquero, J.J.2    Siegel, S.3    Gandler, W.R.4    Green, M.V.5
  • 23
    • 0033308956 scopus 로고    scopus 로고
    • Investigation of depth-of-interaction by pulse shape discrimination in multicrystal detectors read out by avalanche photodiodes
    • Jun.
    • A. Saoudi, C. M. Pepin, F. Dion, M. Bentourkia, R. Lecomte, M. Andreaco, M. Casey, R. Nutt, and H. Dautet, "Investigation of depth-of-interaction by pulse shape discrimination in multicrystal detectors read out by avalanche photodiodes," IEEE Trans. Nucl. Sci., vol. 46, no. 3, pp. 462-467, Jun. 1999.
    • (1999) IEEE Trans. Nucl. Sci. , vol.46 , Issue.3 , pp. 462-467
    • Saoudi, A.1    Pepin, C.M.2    Dion, F.3    Bentourkia, M.4    Lecomte, R.5    Andreaco, M.6    Casey, M.7    Nutt, R.8    Dautet, H.9
  • 24
    • 0027578380 scopus 로고
    • Monte Carlo optimization of depth-of-interaction resolution in PET crystals
    • Apr.
    • T. A. DeVol, "Monte Carlo optimization of depth-of-interaction resolution in PET crystals," IEEE Trans. Nuc Sci., vol. 40, no. 2, pp. 170-174. Apr. 1993.
    • (1993) IEEE Trans. Nuc Sci. , vol.40 , Issue.2 , pp. 170-174
    • Devol, T.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.