메뉴 건너뛰기




Volumn 53, Issue 1, 2006, Pages 297-303

A sampling ADC data acquisition system for positron emission tomography

Author keywords

Data acquisition; Field programmable gate array (FPGA); Positron emission tomography; Signal processing

Indexed keywords

ANALOG TO DIGITAL CONVERSION; FIELD PROGRAMMABLE GATE ARRAYS; IMAGE RECONSTRUCTION; JITTER; MULTIPLEXING; POSITRON EMISSION TOMOGRAPHY; SCINTILLATION;

EID: 33645689588     PISSN: 00189499     EISSN: None     Source Type: Journal    
DOI: 10.1109/TNS.2006.869830     Document Type: Article
Times cited : (28)

References (10)
  • 1
    • 0035117806 scopus 로고    scopus 로고
    • A prototype high resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals
    • Feb.
    • S. I. Ziegler, B. J. Pichler, G. Böning, M. Rafecas, W. Pimpl, E. Lorenz, N. Schmitz, and M. Schwaiger, "A prototype high resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals," Eur. J. Nucl. Med., vol. 28, no. 2, pp. 136-143, Feb. 2001.
    • (2001) Eur. J. Nucl. Med. , vol.28 , Issue.2 , pp. 136-143
    • Ziegler, S.I.1    Pichler, B.J.2    Böning, G.3    Rafecas, M.4    Pimpl, W.5    Lorenz, E.6    Schmitz, N.7    Schwaiger, M.8
  • 2
    • 17644367489 scopus 로고    scopus 로고
    • Characterization and readout of MADPET-II detector modules: Validation of a unique design concept for high resolution small animal PET
    • Feb.
    • D. P. McElroy, W. Pimpl, B. J. Pichler, M. Rafecas, T. Schüler, and S. I. Ziegler, "Characterization and readout of MADPET-II detector modules: Validation of a unique design concept for high resolution small animal PET," IEEE Trans. Nucl. Sci., vol. 52, no. 1, pp. 199-204, Feb. 2005.
    • (2005) IEEE Trans. Nucl. Sci. , vol.52 , Issue.1 , pp. 199-204
    • McElroy, D.P.1    Pimpl, W.2    Pichler, B.J.3    Rafecas, M.4    Schüler, T.5    Ziegler, S.I.6
  • 3
    • 22244440239 scopus 로고    scopus 로고
    • A true list-mode data acquisition system for a small animal PET scanner with independent crystal readout
    • D. P. McElroy, M. Hoose, W. Pimpl, V. Spanoudaki, T. Schüler, and S. I. Ziegler, "A true list-mode data acquisition system for a small animal PET scanner with independent crystal readout," Phys. Med. Biol., vol. 50, pp. 3323-3335, 2005.
    • (2005) Phys. Med. Biol. , vol.50 , pp. 3323-3335
    • McElroy, D.P.1    Hoose, M.2    Pimpl, W.3    Spanoudaki, V.4    Schüler, T.5    Ziegler, S.I.6
  • 5
    • 33645684792 scopus 로고    scopus 로고
    • [Online]
    • i-trOnics GmbH [Online]. Available: http://www.i-tronics.net
  • 6
    • 0000673963 scopus 로고    scopus 로고
    • S-LINK, a data link interface specification for the LHC era
    • Jun.
    • H. C. van der Bij, R. A. McLaren, O. Boyle, and G. Rubin, "S-LINK, a data link interface specification for the LHC era," IEEE Trans. Nucl. Sci., vol. 44, no. 3, pp. 398-402, Jun. 1997.
    • (1997) IEEE Trans. Nucl. Sci. , vol.44 , Issue.3 , pp. 398-402
    • Van Der Bij, H.C.1    McLaren, R.A.2    Boyle, O.3    Rubin, G.4
  • 8
    • 0027539558 scopus 로고
    • Discrete time techniques for time delay estimation
    • Feb.
    • G. Jacovitti and G. Scarano, "Discrete time techniques for time delay estimation," IEEE Trans. Signal Process., vol. 41, no. 2, pp. 525-533, Feb. 1993.
    • (1993) IEEE Trans. Signal Process. , vol.41 , Issue.2 , pp. 525-533
    • Jacovitti, G.1    Scarano, G.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.