메뉴 건너뛰기




Volumn 52, Issue 1-2, 2007, Pages 37-46

A novel fully integrated device dedicated to ECG signal measurement

Author keywords

ECG; Gm C filter; Offset compensation; Switched capacitors filter; Ultra low pass filter

Indexed keywords

HIGH PASS FILTERS; INTEGRATED CIRCUITS; MICROSTRUCTURE; PROBLEM SOLVING; SIGNAL ANALYSIS;

EID: 34548734219     PISSN: 09251030     EISSN: 15731979     Source Type: Journal    
DOI: 10.1007/s10470-007-9097-x     Document Type: Article
Times cited : (5)

References (17)
  • 1
    • 1542303429 scopus 로고    scopus 로고
    • Design and fabrication of an ECG amplifier on silicon using standard CMOS process
    • Rowlands, D., James, D. A., Vanegas, C., Rao, S., & Lisner, P. (2003). Design and fabrication of an ECG amplifier on silicon using standard CMOS process. In Sensors, 2003, Proceedings of IEEE, Vol. 2, 22-24, pp. 1348-1352.
    • (2003) Sensors, 2003, Proceedings of IEEE , vol.2 , Issue.22-24 , pp. 1348-1352
    • Rowlands, D.1    James, D.A.2    Vanegas, C.3    Rao, S.4    Lisner, P.5
  • 2
    • 0032180156 scopus 로고    scopus 로고
    • A CMOS IC for portable EEG acquisition systems
    • Instrumentation and Measurement Technology Conference
    • Martins, R., Selberherr, S., & Vaz, F. (1998). A CMOS IC for portable EEG acquisition systems. Instrumentation and Measurement Technology Conference. IEEE Transactions on Instrumentation and measurement, 47(5), 1191-1196.
    • (1998) IEEE Transactions on Instrumentation and Measurement , vol.47 , Issue.5 , pp. 1191-1196
    • Martins, R.1    Selberherr, S.2    Vaz, F.3
  • 7
    • 77952390721 scopus 로고    scopus 로고
    • Design of an ultra-low frequency, dc-blocked, implantable electromyogram and cortical sensing amplifier
    • Montreal, Canada
    • Ananth, Ravi S. (2005). Design of an ultra-low frequency, dc-blocked, implantable electromyogram and cortical sensing amplifier. 10th Annual Conference of the International FES Society July 2005, Montreal, Canada.
    • (2005) 10th Annual Conference of the International FES Society July 2005
    • Ananth1    Ravi, S.2
  • 10
    • 0031192815 scopus 로고    scopus 로고
    • Improved biquad structures using double-output transconductance blocks for tunable continuous-time filters
    • Prodanov, V. I., & Green, M. M. (1997). Improved biquad structures using double-output transconductance blocks for tunable continuous-time filters. Analog Integrated Circuits and Signal Proceedings, 13, 233-240.
    • (1997) Analog Integrated Circuits and Signal Proceedings , vol.13 , pp. 233-240
    • Prodanov, V.I.1    Green, M.M.2
  • 11
    • 28344435601 scopus 로고    scopus 로고
    • An ECG signal acquisition system integrated in a 0.35 μm CMOS technology
    • Ricardo A. Carmona & Gustavo Linan-Cembrano (Eds.), Bioengineered and bioinspired systems II, Jun. 2005
    • Zhou, L., Bozier, A., Blondé, J. P., Kraemer, M., Felblinger, J., & Braun, F. (2005). An ECG signal acquisition system integrated in a 0.35 μm CMOS technology. Proceedings of SPIE, 5839, 228-237, In Ricardo A. Carmona & Gustavo Linan-Cembrano (Eds.), Bioengineered and bioinspired systems II, Jun. 2005.
    • (2005) Proceedings of SPIE , vol.5839 , pp. 228-237
    • Zhou, L.1    Bozier, A.2    Blondé, J.P.3    Kraemer, M.4    Felblinger, J.5    Braun, F.6
  • 12
    • 0028436603 scopus 로고
    • An automatic offset compensation scheme with ping-pong control for CMOS operational amplifiers
    • 5
    • Yu, C.-G., & Randle, L. G. (1994). An automatic offset compensation scheme with ping-pong control for CMOS operational amplifiers. IEEE Journal of Solid-state Circuits, 29(5), 601-610.
    • (1994) IEEE Journal of Solid-state Circuits , vol.29 , pp. 601-610
    • Yu, C.-G.1    Randle, L.G.2
  • 13
    • 0030286542 scopus 로고    scopus 로고
    • Circuit techniques for reducing the effects of op-amp imperfections: Autozeroing, correlated double sampling, and chopper stabilization
    • 11
    • Enz, C. C., & Temes, G. C. (1996). Circuit techniques for reducing the effects of op-amp imperfections: Autozeroing, correlated double sampling, and chopper stabilization. Proceedings of the IEEE, 84(11), 1584-1614.
    • (1996) Proceedings of the IEEE , vol.84 , pp. 1584-1614
    • Enz, C.C.1    Temes, G.C.2
  • 14
    • 0033097444 scopus 로고    scopus 로고
    • A fully integrated, untrimmed CMOS instrumentation amplifier with submicrovolt offset
    • 3
    • Menolfi, C., & Huang, Q. (1999). A fully integrated, untrimmed CMOS instrumentation amplifier with submicrovolt offset. IEEE Journal of Solid-state Circuits, 34(3), 415-420.
    • (1999) IEEE Journal of Solid-state Circuits , vol.34 , pp. 415-420
    • Menolfi, C.1    Huang, Q.2
  • 15
    • 0034478802 scopus 로고    scopus 로고
    • A CMOS nested-chopper instrumentation amplifier with 100-nV offset
    • 12
    • Bakker, A., Thiele, K., & Huijsing, J. H. (2000). A CMOS nested-chopper instrumentation amplifier with 100-nV offset. IEEE Journal of Solid-state Circuits, 35(12), 1877-1883.
    • (2000) IEEE Journal of Solid-state Circuits , vol.35 , pp. 1877-1883
    • Bakker, A.1    Thiele, K.2    Huijsing, J.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.