메뉴 건너뛰기




Volumn 3, Issue 6, 2007, Pages 970-979

Influence of strontia on various properties of Surgical Simplex® P acrylic bone cement and experimental variants

Author keywords

Acrylic bone cement; Mechanical properties; Physical properties; Strontia; Thermal properties

Indexed keywords

BARIUM SULFATE; BONE; BONE CEMENT; CURING; FATIGUE OF MATERIALS; SETTING; STRONTIUM COMPOUNDS; ZIRCONIA;

EID: 34548533034     PISSN: 17427061     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.actbio.2007.03.010     Document Type: Article
Times cited : (20)

References (51)
  • 3
    • 0031172484 scopus 로고    scopus 로고
    • Properties of acrylic bone cement: state-of-the-art review
    • Lewis G. Properties of acrylic bone cement: state-of-the-art review. J Biomed Mater Res (Appl Biomater) 38 (1997) 155-182
    • (1997) J Biomed Mater Res (Appl Biomater) , vol.38 , pp. 155-182
    • Lewis, G.1
  • 5
    • 34548536018 scopus 로고    scopus 로고
    • Stryker Orthopaedics, Limerick, Ireland. Personal communication; 2004.
  • 7
    • 0029239592 scopus 로고
    • Micromechanisms of fatigue crack initiation and propagation in bone cements
    • Bhambri S.K., and Gilbertson L.N. Micromechanisms of fatigue crack initiation and propagation in bone cements. J Biomed Mater Res 29 (1995) 233-237
    • (1995) J Biomed Mater Res , vol.29 , pp. 233-237
    • Bhambri, S.K.1    Gilbertson, L.N.2
  • 8
    • 0035989712 scopus 로고    scopus 로고
    • Radiopacity in bone cements using an organo-bismuth compound
    • Deb S., Abdulghani S., and Behiri J.C. Radiopacity in bone cements using an organo-bismuth compound. Biomaterials 23 (2002) 3387-3393
    • (2002) Biomaterials , vol.23 , pp. 3387-3393
    • Deb, S.1    Abdulghani, S.2    Behiri, J.C.3
  • 9
    • 0020448507 scopus 로고
    • Detection of the catalytic constituents of dimethyl-p-toluidine even after long-term implantation
    • Boesch P., Herms H., and Lintner F. Detection of the catalytic constituents of dimethyl-p-toluidine even after long-term implantation. Arch Toxicol 51 (1982) 157-166
    • (1982) Arch Toxicol , vol.51 , pp. 157-166
    • Boesch, P.1    Herms, H.2    Lintner, F.3
  • 10
    • 0031081433 scopus 로고    scopus 로고
    • High-performance liquid chromatography assay of N,N-dimethyl-p-toluidine released from bone cements: evidence for toxicity
    • Stea S., Granchi D., Zolezzi C., Ciapetti G., Visentin M., Cavedagna D., et al. High-performance liquid chromatography assay of N,N-dimethyl-p-toluidine released from bone cements: evidence for toxicity. Biomaterials 18 (1997) 243-246
    • (1997) Biomaterials , vol.18 , pp. 243-246
    • Stea, S.1    Granchi, D.2    Zolezzi, C.3    Ciapetti, G.4    Visentin, M.5    Cavedagna, D.6
  • 11
    • 0027300231 scopus 로고
    • genotoxicity analysis of N,N-dimethyl-p-toluidine and N,N-dimethyl aniline
    • Tanninger M., Pasquini R., and Bonatti S. genotoxicity analysis of N,N-dimethyl-p-toluidine and N,N-dimethyl aniline. Environ Mol Mutagen 21 (1993) 349-356
    • (1993) Environ Mol Mutagen , vol.21 , pp. 349-356
    • Tanninger, M.1    Pasquini, R.2    Bonatti, S.3
  • 12
    • 34548542308 scopus 로고    scopus 로고
    • Lewis G, Xu J, Madigan S, Towler MR. Influence of two changes in the composition of an acrylic bone cement on its handling, thermal, physical, and mechanical properties. J Mater Sci Mat Med; in press.
  • 14
    • 0346753842 scopus 로고    scopus 로고
    • Fatigue and fracture toughness of acrylic bone cements modified with long-chain activators
    • Deb S., Lewis G., Janna S.W., Vazquez B., and San Roman J. Fatigue and fracture toughness of acrylic bone cements modified with long-chain activators. J Biomed Mater Res 67 (2003) 571-577
    • (2003) J Biomed Mater Res , vol.67 , pp. 571-577
    • Deb, S.1    Lewis, G.2    Janna, S.W.3    Vazquez, B.4    San Roman, J.5
  • 15
    • 27744483578 scopus 로고    scopus 로고
    • Advances in therapy for osteoporosis
    • Heaney R.P. Advances in therapy for osteoporosis. Clin Med Res 1 (2003) 93-99
    • (2003) Clin Med Res , vol.1 , pp. 93-99
    • Heaney, R.P.1
  • 16
    • 31944442279 scopus 로고    scopus 로고
    • Strontium ranelate; a physiological approach for optimizing bone formation and resorption
    • Marie P.J. Strontium ranelate; a physiological approach for optimizing bone formation and resorption. Bone 38 2, Suppl. 1 (2006) 10-14
    • (2006) Bone , vol.38 , Issue.2 SUPPL. 1 , pp. 10-14
    • Marie, P.J.1
  • 17
    • 0022881267 scopus 로고
    • Sr-89 Strontium kinetics in disseminated carcinoma of the prostate
    • Blake G.M., Zivanovic M.A., and Mcewan A.J. Sr-89 Strontium kinetics in disseminated carcinoma of the prostate. Euro J Nucl Med 12 (1986) 447-451
    • (1986) Euro J Nucl Med , vol.12 , pp. 447-451
    • Blake, G.M.1    Zivanovic, M.A.2    Mcewan, A.J.3
  • 18
    • 0037684340 scopus 로고    scopus 로고
    • Strontium ranelate: new efficient antiosteoporotic agent for treatment of vertebral osteoporosisin postmenopausal women
    • Meunier P.J., Smith L.R., et al. Strontium ranelate: new efficient antiosteoporotic agent for treatment of vertebral osteoporosisin postmenopausal women. Osteoporos Int 13 Suppl. 3 (2002) 66
    • (2002) Osteoporos Int , vol.13 , Issue.SUPPL. 3 , pp. 66
    • Meunier, P.J.1    Smith, L.R.2
  • 19
    • 0002454134 scopus 로고    scopus 로고
    • Strontium ranelate reduces the risk of hip fracture in women with postmenopausal osteoporosis
    • Abstract O14
    • Reginster J.Y., Devogelaer S.A., Padrino J.P., et al. Strontium ranelate reduces the risk of hip fracture in women with postmenopausal osteoporosis. Osteoporos Int 13 Suppl. 3 (2002) Abstract O14
    • (2002) Osteoporos Int , vol.13 , Issue.SUPPL. 3
    • Reginster, J.Y.1    Devogelaer, S.A.2    Padrino, J.P.3
  • 20
    • 0002325012 scopus 로고    scopus 로고
    • Effects of strontium on bone tissue and bone cells
    • Nève J., et al. (Ed), Plenum Press, New York
    • Marie P. Effects of strontium on bone tissue and bone cells. In: Nève J., et al. (Ed). Therapeutic uses of trace elements (1996), Plenum Press, New York
    • (1996) Therapeutic uses of trace elements
    • Marie, P.1
  • 21
    • 0029960972 scopus 로고    scopus 로고
    • Strontium increases vertebral bone volume in rats at a low dose that does not induce detectable mineralization defect
    • Gryna M.D., Hamilton E., and Cheung R. Strontium increases vertebral bone volume in rats at a low dose that does not induce detectable mineralization defect. Bone 18 (1996) 253-258
    • (1996) Bone , vol.18 , pp. 253-258
    • Gryna, M.D.1    Hamilton, E.2    Cheung, R.3
  • 22
    • 0015847611 scopus 로고
    • Regulation of vitamin D metabolism and function
    • Omdahl J.L. Regulation of vitamin D metabolism and function. Physiol Rev 55 (1973) 327-372
    • (1973) Physiol Rev , vol.55 , pp. 327-372
    • Omdahl, J.L.1
  • 23
    • 1542726179 scopus 로고    scopus 로고
    • Characterisation of commercial ionomer glasses using magic angle nuclear magnetic resonance (MAS NMR)
    • Stamboulis A., Law R.V., and Hill R. Characterisation of commercial ionomer glasses using magic angle nuclear magnetic resonance (MAS NMR). Biomaterials 25 (2005) 3907-3913
    • (2005) Biomaterials , vol.25 , pp. 3907-3913
    • Stamboulis, A.1    Law, R.V.2    Hill, R.3
  • 24
    • 0242364793 scopus 로고    scopus 로고
    • Preliminary work on the antibacterial effect of strontium in glass ionomer cements
    • Guida A., Towler M.R., Wall J.G., Hill R.G., and Eramo S. Preliminary work on the antibacterial effect of strontium in glass ionomer cements. J Mater Sci Lett 22 (2003) 1401-1403
    • (2003) J Mater Sci Lett , vol.22 , pp. 1401-1403
    • Guida, A.1    Towler, M.R.2    Wall, J.G.3    Hill, R.G.4    Eramo, S.5
  • 25
    • 0942287282 scopus 로고    scopus 로고
    • Czermak B, Nogler M, Wimmer C. Infection of a total hip arthroplasty with Prevotella loeschii
    • Steingruber I., and Bach C.M. Czermak B, Nogler M, Wimmer C. Infection of a total hip arthroplasty with Prevotella loeschii. Clin Orthop 418 (2004) 222-224
    • (2004) Clin Orthop , vol.418 , pp. 222-224
    • Steingruber, I.1    Bach, C.M.2
  • 26
    • 0031830154 scopus 로고    scopus 로고
    • Improved detection of infection in hip replacements: a currently underestimated problem
    • Tunney M., Patrick S., Gorman S., Nixon J.R., Anderson N., Davis R., et al. Improved detection of infection in hip replacements: a currently underestimated problem. J Bone Joint Surg B 80 (1998) 568-572
    • (1998) J Bone Joint Surg B , vol.80 , pp. 568-572
    • Tunney, M.1    Patrick, S.2    Gorman, S.3    Nixon, J.R.4    Anderson, N.5    Davis, R.6
  • 28
    • 8644233352 scopus 로고    scopus 로고
    • Why are total knee replacements revised? Analysis of early revision in a community knee implant registry
    • Gioe T.J., Killeen K.K., Grimm K., Mehle S., and Scheltema K. Why are total knee replacements revised? Analysis of early revision in a community knee implant registry. Clin Orthop 428 (2004) 100-106
    • (2004) Clin Orthop , vol.428 , pp. 100-106
    • Gioe, T.J.1    Killeen, K.K.2    Grimm, K.3    Mehle, S.4    Scheltema, K.5
  • 29
    • 0034255813 scopus 로고    scopus 로고
    • A novel injectable bioactive bone cement for spinal surgery: a developmental and preclinical study
    • Li Y.W., Leong J.C.Y., Lu W.W., Luk K.D.K., Cheung K.M.C., Chiu K.Y., et al. A novel injectable bioactive bone cement for spinal surgery: a developmental and preclinical study. J Biomed Mater Res 52 (2000) 164-170
    • (2000) J Biomed Mater Res , vol.52 , pp. 164-170
    • Li, Y.W.1    Leong, J.C.Y.2    Lu, W.W.3    Luk, K.D.K.4    Cheung, K.M.C.5    Chiu, K.Y.6
  • 30
    • 0035893684 scopus 로고    scopus 로고
    • Bioactive bone cement as a principal fixture for spinal burst fracture: an in vitro biomechanical and morphologic study
    • Lu W.W., Cheung K.M.C., Li Y.W., Luk K.D.K., Holmes A.D., Zhu Q.A., et al. Bioactive bone cement as a principal fixture for spinal burst fracture: an in vitro biomechanical and morphologic study. Spine 26 (2001) 2684-2691
    • (2001) Spine , vol.26 , pp. 2684-2691
    • Lu, W.W.1    Cheung, K.M.C.2    Li, Y.W.3    Luk, K.D.K.4    Holmes, A.D.5    Zhu, Q.A.6
  • 31
    • 1342301648 scopus 로고    scopus 로고
    • In vivo cancellous bone remodeling on a strontium-containing hydroxyapatite (Sr-HA) bioactive cement
    • Wong C.T., Lu W.W., Chan W.K., Cheung K.M.C., Luk K.D.K., Lu D.S., et al. In vivo cancellous bone remodeling on a strontium-containing hydroxyapatite (Sr-HA) bioactive cement. J Biomed Mater Res A 68 (2004) 513-521
    • (2004) J Biomed Mater Res A , vol.68 , pp. 513-521
    • Wong, C.T.1    Lu, W.W.2    Chan, W.K.3    Cheung, K.M.C.4    Luk, K.D.K.5    Lu, D.S.6
  • 33
    • 16644368407 scopus 로고    scopus 로고
    • Ultrastructural study of mineralization of a strontium-containing hydroxyapatite (Sr-HA) cement in vivo
    • Wong C.T., Chen Q.Z., Lu W.W., Leong J.C.Y., Chan W.K., Cheung K.M.C., et al. Ultrastructural study of mineralization of a strontium-containing hydroxyapatite (Sr-HA) cement in vivo. J Biomed Mater Res 70 (2004) 428-435
    • (2004) J Biomed Mater Res , vol.70 , pp. 428-435
    • Wong, C.T.1    Chen, Q.Z.2    Lu, W.W.3    Leong, J.C.Y.4    Chan, W.K.5    Cheung, K.M.C.6
  • 34
    • 24744454821 scopus 로고    scopus 로고
    • Vertebroplasty by use of a strontium-containing bioactive bone cement
    • Cheung K.M.C., Lu W.W., Luk K.D.K., Wong C.T., Chan J.X., Liu S.L., et al. Vertebroplasty by use of a strontium-containing bioactive bone cement. Spine 30 Suppl. 17S (2005) S84
    • (2005) Spine , vol.30 , Issue.SUPPL. 17S
    • Cheung, K.M.C.1    Lu, W.W.2    Luk, K.D.K.3    Wong, C.T.4    Chan, J.X.5    Liu, S.L.6
  • 35
    • 33646367883 scopus 로고    scopus 로고
    • Strontium-containing hydroxyapatite bioactive bone cement in revision hip arthroplasty
    • Ni G.X., Chiu K.Y., Lu W.W., Wang Y., Zhang Y.G., Hao L.B., et al. Strontium-containing hydroxyapatite bioactive bone cement in revision hip arthroplasty. Biomaterials 27 (2006) 4348-4355
    • (2006) Biomaterials , vol.27 , pp. 4348-4355
    • Ni, G.X.1    Chiu, K.Y.2    Lu, W.W.3    Wang, Y.4    Zhang, Y.G.5    Hao, L.B.6
  • 36
    • 33745261723 scopus 로고    scopus 로고
    • Interfacial behavior of strontium-containing hydroxyapatite cement with cancellous and cortical bone
    • Ni G.X., Lu W.W., Lu B., Chiu K.Y., Yang C., Li Z.Y., et al. Interfacial behavior of strontium-containing hydroxyapatite cement with cancellous and cortical bone. Biomaterials 27 (2006) 5127-5133
    • (2006) Biomaterials , vol.27 , pp. 5127-5133
    • Ni, G.X.1    Lu, W.W.2    Lu, B.3    Chiu, K.Y.4    Yang, C.5    Li, Z.Y.6
  • 37
    • 34548527589 scopus 로고    scopus 로고
    • Hernandez, Goni I, Gurruchaga M. Incorporation of strontium hydroxyapatite to injectable acrylic bone cements. In: Transactions of the 29th european conference on biomaterials, September 27-October 1, Nantes; 2006. p. 37.
  • 40
    • 34247628856 scopus 로고    scopus 로고
    • Influence of changes in the composition of an acrylic bone cement on its polymerization kinetics
    • Lewis G., and Mishra S.R. Influence of changes in the composition of an acrylic bone cement on its polymerization kinetics. J Biomed Mater Res: Appl Biomater 81B (2007) 524-529
    • (2007) J Biomed Mater Res: Appl Biomater , vol.81 B , pp. 524-529
    • Lewis, G.1    Mishra, S.R.2
  • 42
    • 34548540764 scopus 로고    scopus 로고
    • ASTM International, West Conshochocken, PA p. 1146-53
    • ASTM Standard F 2118-03. Test method for constant amplitude force controlled fatigue testing of acrylic bone cement materials. Annual book of ASTM standards. Medical devices and emergency medical devices vol. 13.01 (2006), ASTM International, West Conshochocken, PA p. 1146-53
    • (2006) Medical devices and emergency medical devices , vol.13 01
    • ASTM Standard F 2118-031
  • 43
    • 1642280185 scopus 로고    scopus 로고
    • Estimation of the minimum number of test specimens for fatigue testing of acrylic bone cement
    • Lewis G., and Sadhasivini A. Estimation of the minimum number of test specimens for fatigue testing of acrylic bone cement. Biomaterials 25 (2004) 4425-4432
    • (2004) Biomaterials , vol.25 , pp. 4425-4432
    • Lewis, G.1    Sadhasivini, A.2
  • 45
    • 33746686325 scopus 로고    scopus 로고
    • Critical comparison of two methods for the determination of nanomechanical properties of a material: application to synthetic and natural biomaterials
    • Lewis G., Xu J., Dunne N., Daly C., and Orr J. Critical comparison of two methods for the determination of nanomechanical properties of a material: application to synthetic and natural biomaterials. J Biomed Mater Res Part B: Appl Biomater B 78 (2006) 312-317
    • (2006) J Biomed Mater Res Part B: Appl Biomater B , vol.78 , pp. 312-317
    • Lewis, G.1    Xu, J.2    Dunne, N.3    Daly, C.4    Orr, J.5
  • 46
    • 34247603907 scopus 로고    scopus 로고
    • Evaluation of an accelerated aging medium for acrylic bone cement based on analysis of quasi-static and dynamic nanoindentation measurements on laboratory-prepared and retrieved specimens
    • Lewis G., Xu J., Dunne N., Daly C., and Orr J. Evaluation of an accelerated aging medium for acrylic bone cement based on analysis of quasi-static and dynamic nanoindentation measurements on laboratory-prepared and retrieved specimens. J Biomed Mater Res Part B: Appl Biomater 81B (2007) 544-550
    • (2007) J Biomed Mater Res Part B: Appl Biomater , vol.81 B , pp. 544-550
    • Lewis, G.1    Xu, J.2    Dunne, N.3    Daly, C.4    Orr, J.5
  • 47
    • 12744261645 scopus 로고    scopus 로고
    • Kinetic effect of hydroxyapatite types on the polymerization of acrylic bone cements
    • Morejon L., Delgado J.A., Davidenko N., Mendizabal E., and Barbosa E.H. Kinetic effect of hydroxyapatite types on the polymerization of acrylic bone cements. Int J Polym Mater 52 (2003) 637-654
    • (2003) Int J Polym Mater , vol.52 , pp. 637-654
    • Morejon, L.1    Delgado, J.A.2    Davidenko, N.3    Mendizabal, E.4    Barbosa, E.H.5
  • 48
    • 32544460432 scopus 로고    scopus 로고
    • Surface characterization of various bone cements prepared with functionalized methacrylates/bioactive ceramics in relation to HOB behavior
    • Salih V., Mordan N., Abou Neel E.A., Armitage D.A., Jones F.H., Knowles J.C., et al. Surface characterization of various bone cements prepared with functionalized methacrylates/bioactive ceramics in relation to HOB behavior. Acta Mater 2 (2005) 143-154
    • (2005) Acta Mater , vol.2 , pp. 143-154
    • Salih, V.1    Mordan, N.2    Abou Neel, E.A.3    Armitage, D.A.4    Jones, F.H.5    Knowles, J.C.6
  • 49
    • 34548540626 scopus 로고    scopus 로고
    • Ginebra MP, Morejon L, Delgad JA, Manero JM, Gil FJ, Artola A, Goni I, et al. Effect of size distribution of the PMMA beads on the fatigue crack propagation of acrylic bone cements. In: Transactions of the 16th European conference on biomaterials, London; September 2001. p. T20.
  • 50
    • 15944424328 scopus 로고    scopus 로고
    • Influence of the method of blending an antibiotic powder with an acrylic bone cement powder on the physical, mechanical, and thermal properties of the cured cement
    • Lewis G., Janna S., and Bhattaram A. Influence of the method of blending an antibiotic powder with an acrylic bone cement powder on the physical, mechanical, and thermal properties of the cured cement. Biomaterials 26 (2005) 4317-4325
    • (2005) Biomaterials , vol.26 , pp. 4317-4325
    • Lewis, G.1    Janna, S.2    Bhattaram, A.3
  • 51
    • 34548524689 scopus 로고    scopus 로고
    • Wong CT. Osteoconduction and osseointegration of a strontium-containing hydroxyapatite bioactive bone cement: in vitro and in vivo investigations. PhD thesis. The University of Hong Kong; 2004.


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.