메뉴 건너뛰기




Volumn 22, Issue 4, 2007, Pages 1162-1176

Monolithic/modularized voltage regulator channel

Author keywords

Adaptive voltage position (AVP); Current sharing (CS); Distributed control; Integration; Interleaving; Monolithic modularized voltage regulator channel (MVRC); Tolerance; Voltage regulator module (VRM)

Indexed keywords

ADAPTIVE VOLTAGE POSITION; MODULARIZED VOLTAGE REGULATOR CHANNEL; MONOLITHIC VOLTAGE REGULATOR CHANNEL; VOLTAGE REGULATOR MODULE;

EID: 34547106822     PISSN: 08858993     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPEL.2007.900466     Document Type: Article
Times cited : (13)

References (29)
  • 1
    • 34547103909 scopus 로고
    • Distributed power system
    • Unitrode-Seminar, Online, Available
    • B. Mammano, "Distributed power system," Unitrode-Seminar, S9M-900, 1993 [Online]. Available: http://focus.ti.com/lit/ml/slip099/ slup099.pdf
    • (1993)
    • Mammano, B.1
  • 2
    • 0033309037 scopus 로고    scopus 로고
    • A classification and evaluation of paralleling methods for power supply modules
    • S. Luo, Z. Ye, R. Lin, and F. C. Lee, "A classification and evaluation of paralleling methods for power supply modules," in Proc. Power Electron. Specialists Conf., 1999, vol. 2, pp. 901-908.
    • (1999) Proc. Power Electron. Specialists Conf , vol.2 , pp. 901-908
    • Luo, S.1    Ye, Z.2    Lin, R.3    Lee, F.C.4
  • 4
    • 0037018125 scopus 로고    scopus 로고
    • Power-supply ICs go multiphase to take on 100-A loads
    • Mar. 4, Online, Available
    • A. Bindra, "Power-supply ICs go multiphase to take on 100-A loads," Electronic Design Mar. 4, 2002 [Online]. Available: http://www.elecdesign.com/Articles/ArticleID/1564/1564.html
    • (2002) Electronic Design
    • Bindra, A.1
  • 5
    • 34547137813 scopus 로고    scopus 로고
    • Intel, VRM 9.1 DC-DC converter design guidelines, Santa Clara, CA, 2002 [Online]. Available: ftp://download.intel.com/design/Xeon/guides/29864601.pdf
    • Intel, "VRM 9.1 DC-DC converter design guidelines," Santa Clara, CA, 2002 [Online]. Available: ftp://download.intel.com/design/Xeon/guides/29864601.pdf
  • 6
    • 33947159688 scopus 로고    scopus 로고
    • Lateral power MOSFET for megahertz-frequency, high-density DC/DC converters
    • Jan
    • Z. J. Shen, D. N. Okada, F. Lin, S. Anderson, and X. Cheng, "Lateral power MOSFET for megahertz-frequency, high-density DC/DC converters," IEEE Trans. Power Electron., vol. 21, no. 1, pp. 11-17, Jan. 2006.
    • (2006) IEEE Trans. Power Electron , vol.21 , Issue.1 , pp. 11-17
    • Shen, Z.J.1    Okada, D.N.2    Lin, F.3    Anderson, S.4    Cheng, X.5
  • 7
    • 0035329036 scopus 로고    scopus 로고
    • Chip-scale packaging of power devices and its application in integrated power electronics modules
    • May
    • X. Liu, X. Jing, and G.-Q. Lu, "Chip-scale packaging of power devices and its application in integrated power electronics modules," IEEE Trans. Adv. Packag., vol. 24, no. 2, pp. 206-215, May 2001.
    • (2001) IEEE Trans. Adv. Packag , vol.24 , Issue.2 , pp. 206-215
    • Liu, X.1    Jing, X.2    Lu, G.-Q.3
  • 8
    • 34547123474 scopus 로고    scopus 로고
    • Volterra's 3rd generation integrated switching regulators for Intel microprocessor for Intel microprocessor power
    • presented at the, Seattle, WA, Aug. 28-29
    • A. Burstein, "Volterra's 3rd generation integrated switching regulators for Intel microprocessor for Intel microprocessor power," presented at the Intel Power Symp., Seattle, WA, Aug. 28-29, 2002.
    • (2002) Intel Power Symp
    • Burstein, A.1
  • 9
    • 34547119838 scopus 로고    scopus 로고
    • Design challenges of integrated power trains (DrMOS)
    • presented at the, Seattle, WA, Sep. 8-9, unpublished
    • P. Rutter, "Design challenges of integrated power trains (DrMOS)," presented at the Intel Technol. Symp., Seattle, WA, Sep. 8-9, 2004, unpublished.
    • (2004) Intel Technol. Symp
    • Rutter, P.1
  • 10
    • 20344374666 scopus 로고    scopus 로고
    • Distributed, master-less control of modular DC-DC converters
    • Aug. 16-19
    • S. Gray, Z. Gao, and R. M. Button, "Distributed, master-less control of modular DC-DC converters," in Proc. 2nd Int. Energy Conv. Eng. Conf. Aug. 16-19, 2004, pp. 1-9.
    • (2004) Proc. 2nd Int. Energy Conv. Eng. Conf , pp. 1-9
    • Gray, S.1    Gao, Z.2    Button, R.M.3
  • 13
    • 0034313358 scopus 로고    scopus 로고
    • A novel current-sharing control technique for low-voltage high-current voltage regulator module applications
    • Nov
    • X. Zhou, P. Xu, and F. C. Lee, "A novel current-sharing control technique for low-voltage high-current voltage regulator module applications," IEEE Trans. Power Electron., vol. 15, no. 6, pp. 1153-1162, Nov. 2000.
    • (2000) IEEE Trans. Power Electron , vol.15 , Issue.6 , pp. 1153-1162
    • Zhou, X.1    Xu, P.2    Lee, F.C.3
  • 14
    • 9244235010 scopus 로고    scopus 로고
    • Multiphase voltage-mode hysteretic controlled DC-DC converter with novel current sharing
    • Nov
    • J. Abu-Qahouq, H. Mao, and I. Batarseh, "Multiphase voltage-mode hysteretic controlled DC-DC converter with novel current sharing," IEEE Trans. Power Electron., vol. 19, no. 6, pp. 1397-1407, Nov. 2004.
    • (2004) IEEE Trans. Power Electron , vol.19 , Issue.6 , pp. 1397-1407
    • Abu-Qahouq, J.1    Mao, H.2    Batarseh, I.3
  • 17
    • 34547132705 scopus 로고    scopus 로고
    • Intel, DrMOS specifications, Santa Clara, CA, 2004 [Online]. Available: ftp://download.intel.com/design/Pentium4/papers/DrMOS.pdf
    • Intel, "DrMOS specifications," Santa Clara, CA, 2004 [Online]. Available: ftp://download.intel.com/design/Pentium4/papers/DrMOS.pdf
  • 19
    • 17344391322 scopus 로고    scopus 로고
    • S. Banerjee and S. Parui, Delays in PWM control loops imply discontinuity in sampled data models of power electronic circuits, in Proc. Int. Symp. Circuits Systems, 2003, 3, no. 25-28, pp. III-92-III-95.
    • S. Banerjee and S. Parui, "Delays in PWM control loops imply discontinuity in sampled data models of power electronic circuits," in Proc. Int. Symp. Circuits Systems, 2003, vol. 3, no. 25-28, pp. III-92-III-95.
  • 20
    • 0000145316 scopus 로고
    • Interleaving technique in distributed power conversion systems
    • May
    • C. Chin and M. A. Knights, "Interleaving technique in distributed power conversion systems," IEEE Trans. Circuits Syst. I, Fundam. Theory Appl., vol. 42, no. 5, pp. 245-251, May 1995.
    • (1995) IEEE Trans. Circuits Syst. I, Fundam. Theory Appl , vol.42 , Issue.5 , pp. 245-251
    • Chin, C.1    Knights, M.A.2
  • 21
    • 0003463639 scopus 로고
    • Interleaved conversion techniques for high density power supplies,
    • Ph.D. dissertation, Dept. Elect. Eng. Comput. Sci, Mass. Inst. Technol, Cambridge, MA
    • B. A. Miwa, "Interleaved conversion techniques for high density power supplies," Ph.D. dissertation, Dept. Elect. Eng. Comput. Sci., Mass. Inst. Technol., Cambridge, MA, 1992.
    • (1992)
    • Miwa, B.A.1
  • 23
    • 84958976330 scopus 로고    scopus 로고
    • Implementation of an automatic interleaving approach for parallel DC/DC converter without interleaving bus
    • L. Feng and Q. Wenlong, "Implementation of an automatic interleaving approach for parallel DC/DC converter without interleaving bus," in Proc. IEEE 6th Int. Conf. Electr. Machines Syst., 2003, vol. 1, pp. 368-371.
    • (2003) Proc. IEEE 6th Int. Conf. Electr. Machines Syst , vol.1 , pp. 368-371
    • Feng, L.1    Wenlong, Q.2
  • 25
    • 34547128267 scopus 로고    scopus 로고
    • Intel, Enhanced Intel® SpeedStep® technology for the Intel® Pentium® M processor, Santa Clara, CA, 2004 [Online]. Available: ftp://download.intel.com/ design/network/papers/30117401.pdf
    • Intel, "Enhanced Intel® SpeedStep® technology for the Intel® Pentium® M processor," Santa Clara, CA, 2004 [Online]. Available: ftp://download.intel.com/ design/network/papers/30117401.pdf
  • 26
    • 0037233005 scopus 로고    scopus 로고
    • Optimal design of the active droop control method for the transient response
    • K. Yao, K. Lee, M. Xu, and F. C. Lee, "Optimal design of the active droop control method for the transient response," in Proc. Appl. Power Electron. Conf., 2003, vol. 2, pp. 718-723.
    • (2003) Proc. Appl. Power Electron. Conf , vol.2 , pp. 718-723
    • Yao, K.1    Lee, K.2    Xu, M.3    Lee, F.C.4
  • 27
    • 0033871314 scopus 로고    scopus 로고
    • B. T. Irving and M. M. Jovanovic, Analysis, design, and performance evaluation of droop current-sharing method, in Proc. Appl. Power Electron. Conf., 2000, 1, pp. 235.A-241.A.
    • B. T. Irving and M. M. Jovanovic, "Analysis, design, and performance evaluation of droop current-sharing method," in Proc. Appl. Power Electron. Conf., 2000, vol. 1, pp. 235.A-241.A.
  • 28
    • 34547120359 scopus 로고    scopus 로고
    • S. L. Meyer, Data analysis for scientists and engineers, Management Consultants, Ltd., Sep. 1992.
    • S. L. Meyer, "Data analysis for scientists and engineers," Management Consultants, Ltd., Sep. 1992.
  • 29
    • 0034499232 scopus 로고    scopus 로고
    • Lossless current sensing in low voltage high current DC/DC modular supplies
    • Dec
    • E. Dallago, M. Passoni, and G. Sassone, "Lossless current sensing in low voltage high current DC/DC modular supplies," IEEE Trans. Ind. Electron., vol. 47, no. 6, pp. 1249-1252, Dec. 2000.
    • (2000) IEEE Trans. Ind. Electron , vol.47 , Issue.6 , pp. 1249-1252
    • Dallago, E.1    Passoni, M.2    Sassone, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.