메뉴 건너뛰기




Volumn 25, Issue 6, 2007, Pages 775-783

Quantification of cerebral blood flow in nonhuman primates using arterial spin labeling and a two-compartment model

Author keywords

Arterial transit time; Monkey brain; Perfusion; Sensitivity mapping

Indexed keywords

ACETAZOLAMIDE;

EID: 34447557694     PISSN: 0730725X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.mri.2006.11.028     Document Type: Article
Times cited : (20)

References (57)
  • 1
    • 0036714079 scopus 로고    scopus 로고
    • Absolute quantification of cerebral blood flow with magnetic resonance, reproducibility of the method, and comparison with H2(15)O positron emission tomography
    • Carroll T.J., Teneggi V., Jobin M., Squassante L., Treyer V., Hany T.F., et al. Absolute quantification of cerebral blood flow with magnetic resonance, reproducibility of the method, and comparison with H2(15)O positron emission tomography. J Cereb Blood Flow Metab 22 9 (2002) 1149-1156
    • (2002) J Cereb Blood Flow Metab , vol.22 , Issue.9 , pp. 1149-1156
    • Carroll, T.J.1    Teneggi, V.2    Jobin, M.3    Squassante, L.4    Treyer, V.5    Hany, T.F.6
  • 2
    • 0037626078 scopus 로고    scopus 로고
    • Functional tumor imaging with dynamic contrast-enhanced magnetic resonance imaging
    • Choyke P.L., Dwyer A.J., and Knopp M.V. Functional tumor imaging with dynamic contrast-enhanced magnetic resonance imaging. J Magn Reson Imaging 17 5 (2003) 509-520
    • (2003) J Magn Reson Imaging , vol.17 , Issue.5 , pp. 509-520
    • Choyke, P.L.1    Dwyer, A.J.2    Knopp, M.V.3
  • 3
    • 0036794518 scopus 로고    scopus 로고
    • Dynamic contrast-enhanced MRI in clinical oncology: current status and future directions
    • Padhani A.R. Dynamic contrast-enhanced MRI in clinical oncology: current status and future directions. J Magn Reson Imaging 16 4 (2002) 407-422
    • (2002) J Magn Reson Imaging , vol.16 , Issue.4 , pp. 407-422
    • Padhani, A.R.1
  • 4
    • 0026542167 scopus 로고
    • Magnetic resonance imaging of perfusion using spin inversion of arterial water
    • Williams D.S., Detre J.A., Leigh J.S., and Koretsky A.P. Magnetic resonance imaging of perfusion using spin inversion of arterial water. Proc Natl Acad Sci U S A 89 1 (1992) 212-216
    • (1992) Proc Natl Acad Sci U S A , vol.89 , Issue.1 , pp. 212-216
    • Williams, D.S.1    Detre, J.A.2    Leigh, J.S.3    Koretsky, A.P.4
  • 7
    • 0029952944 scopus 로고    scopus 로고
    • Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow
    • Alsop D.C., and Detre J.A. Reduced transit-time sensitivity in noninvasive magnetic resonance imaging of human cerebral blood flow. J Cereb Blood Flow Metab 16 6 (1996) 1236-1249
    • (1996) J Cereb Blood Flow Metab , vol.16 , Issue.6 , pp. 1236-1249
    • Alsop, D.C.1    Detre, J.A.2
  • 8
    • 13844276067 scopus 로고    scopus 로고
    • Human brain: reliability and reproducibility of pulsed arterial spin-labeling perfusion MR imaging
    • Jahng G.H., Song E., Zhu X.P., Matson G.B., Weiner M.W., and Schuff N. Human brain: reliability and reproducibility of pulsed arterial spin-labeling perfusion MR imaging. Radiology 234 3 (2005) 909-916
    • (2005) Radiology , vol.234 , Issue.3 , pp. 909-916
    • Jahng, G.H.1    Song, E.2    Zhu, X.P.3    Matson, G.B.4    Weiner, M.W.5    Schuff, N.6
  • 9
    • 1842511490 scopus 로고    scopus 로고
    • Perfusion imaging using arterial spin labeling
    • Golay X., Hendrikse J., and Lim T.C. Perfusion imaging using arterial spin labeling. Top Magn Reson Imaging 15 1 (2004) 10-27
    • (2004) Top Magn Reson Imaging , vol.15 , Issue.1 , pp. 10-27
    • Golay, X.1    Hendrikse, J.2    Lim, T.C.3
  • 10
    • 28444486874 scopus 로고    scopus 로고
    • Arterial spin labeling in small animals: methods and applications to experimental cerebral ischemia
    • Thomas D.L. Arterial spin labeling in small animals: methods and applications to experimental cerebral ischemia. J Magn Reson Imaging 22 6 (2005) 741-744
    • (2005) J Magn Reson Imaging , vol.22 , Issue.6 , pp. 741-744
    • Thomas, D.L.1
  • 11
    • 33646844606 scopus 로고    scopus 로고
    • Golay X, Petersen ET. Arterial spin labeling: benefits and pitfalls of high magnetic field. Neuroimaging Clin N Am 2006;16(2):259-68, x.
  • 13
    • 7044220816 scopus 로고    scopus 로고
    • Surface-based approaches to spatial localization and registration in primate cerebral cortex
    • Van Essen D.C. Surface-based approaches to spatial localization and registration in primate cerebral cortex. Neuroimage 23 Suppl 1 (2004) S97-S107
    • (2004) Neuroimage , vol.23 , Issue.SUPPL. 1
    • Van Essen, D.C.1
  • 14
    • 0035849892 scopus 로고    scopus 로고
    • Neurophysiological investigation of the basis of the fMRI signal
    • Logothetis N.K., Pauls J., Augath M., Trinath T., and Oeltermann A. Neurophysiological investigation of the basis of the fMRI signal. Nature 412 6843 (2001) 150-157
    • (2001) Nature , vol.412 , Issue.6843 , pp. 150-157
    • Logothetis, N.K.1    Pauls, J.2    Augath, M.3    Trinath, T.4    Oeltermann, A.5
  • 15
    • 84939682609 scopus 로고
    • The nitrous oxide method for the quantitative determination of cerebral blood flow in man: theory procedure and normal values
    • Kety S.S., and Schmidt C.F. The nitrous oxide method for the quantitative determination of cerebral blood flow in man: theory procedure and normal values. J Clin Invest 27 4 (1948) 476-483
    • (1948) J Clin Invest , vol.27 , Issue.4 , pp. 476-483
    • Kety, S.S.1    Schmidt, C.F.2
  • 16
    • 0016284544 scopus 로고
    • Evidence of the limitations of water as a freely diffusible tracer in brain of the rhesus monkey
    • Eichling J.O., Raichle M.E., Grubb Jr. R.L., and Ter-Pogossian M.M. Evidence of the limitations of water as a freely diffusible tracer in brain of the rhesus monkey. Circ Res 35 3 (1974) 358-364
    • (1974) Circ Res , vol.35 , Issue.3 , pp. 358-364
    • Eichling, J.O.1    Raichle, M.E.2    Grubb Jr., R.L.3    Ter-Pogossian, M.M.4
  • 17
    • 0028144620 scopus 로고
    • Radioactive microsphere validation of a volume localized continuous saturation perfusion measurement
    • Walsh E.G., Minematsu K., Leppo J., and Moore S.C. Radioactive microsphere validation of a volume localized continuous saturation perfusion measurement. Magn Reson Med 31 2 (1994) 147-153
    • (1994) Magn Reson Med , vol.31 , Issue.2 , pp. 147-153
    • Walsh, E.G.1    Minematsu, K.2    Leppo, J.3    Moore, S.C.4
  • 18
    • 0019518226 scopus 로고
    • Extraction of water labeled with oxygen 15 during single-capillary transit. Influence of blood pressure, osmolarity, and blood-brain barrier damage
    • Go K.G., Lammertsma A.A., Paans A.M., Vaalburg W., and Woldring M.G. Extraction of water labeled with oxygen 15 during single-capillary transit. Influence of blood pressure, osmolarity, and blood-brain barrier damage. Arch Neurol 38 9 (1981) 581-584
    • (1981) Arch Neurol , vol.38 , Issue.9 , pp. 581-584
    • Go, K.G.1    Lammertsma, A.A.2    Paans, A.M.3    Vaalburg, W.4    Woldring, M.G.5
  • 19
    • 0030851658 scopus 로고    scopus 로고
    • Evidence for the exchange of arterial spin-labeled water with tissue water in rat brain from diffusion-sensitized measurements of perfusion
    • Silva A.C., Williams D.S., and Koretsky A.P. Evidence for the exchange of arterial spin-labeled water with tissue water in rat brain from diffusion-sensitized measurements of perfusion. Magn Reson Med 38 2 (1997) 232-237
    • (1997) Magn Reson Med , vol.38 , Issue.2 , pp. 232-237
    • Silva, A.C.1    Williams, D.S.2    Koretsky, A.P.3
  • 20
    • 0031032547 scopus 로고    scopus 로고
    • Estimation of water extraction fractions in rat brain using magnetic resonance measurement of perfusion with arterial spin labeling
    • Silva A.C., Zhang W., Williams D.S., and Koretsky A.P. Estimation of water extraction fractions in rat brain using magnetic resonance measurement of perfusion with arterial spin labeling. Magn Reson Med 37 1 (1997) 58-68
    • (1997) Magn Reson Med , vol.37 , Issue.1 , pp. 58-68
    • Silva, A.C.1    Zhang, W.2    Williams, D.S.3    Koretsky, A.P.4
  • 21
    • 0033817185 scopus 로고    scopus 로고
    • Effect of restricted water exchange on cerebral blood flow values calculated with arterial spin tagging: a theoretical investigation
    • St. Lawrence K.S., Frank J.A., and McLaughlin A.C. Effect of restricted water exchange on cerebral blood flow values calculated with arterial spin tagging: a theoretical investigation. Magn Reson Med 44 3 (2000) 440-449
    • (2000) Magn Reson Med , vol.44 , Issue.3 , pp. 440-449
    • St. Lawrence, K.S.1    Frank, J.A.2    McLaughlin, A.C.3
  • 22
    • 0031821720 scopus 로고    scopus 로고
    • A general kinetic model for quantitative perfusion imaging with arterial spin labeling
    • Buxton R.B., Frank L.R., Wong E.C., Siewert B., Warach S., and Edelman R.R. A general kinetic model for quantitative perfusion imaging with arterial spin labeling. Magn Reson Med 40 3 (1998) 383-396
    • (1998) Magn Reson Med , vol.40 , Issue.3 , pp. 383-396
    • Buxton, R.B.1    Frank, L.R.2    Wong, E.C.3    Siewert, B.4    Warach, S.5    Edelman, R.R.6
  • 23
    • 0036298274 scopus 로고    scopus 로고
    • Improved accuracy of human cerebral blood perfusion measurements using arterial spin labeling: accounting for capillary water permeability
    • Parkes L.M., and Tofts P.S. Improved accuracy of human cerebral blood perfusion measurements using arterial spin labeling: accounting for capillary water permeability. Magn Reson Med 48 1 (2002) 27-41
    • (2002) Magn Reson Med , vol.48 , Issue.1 , pp. 27-41
    • Parkes, L.M.1    Tofts, P.S.2
  • 25
    • 0033624185 scopus 로고    scopus 로고
    • H(2)(15)O PET validation of steady-state arterial spin tagging cerebral blood flow measurements in humans
    • Ye F.Q., Berman K.F., Ellmore T., Esposito G., van Horn J.D., Yang Y., et al. H(2)(15)O PET validation of steady-state arterial spin tagging cerebral blood flow measurements in humans. Magn Reson Med 44 3 (2000) 450-456
    • (2000) Magn Reson Med , vol.44 , Issue.3 , pp. 450-456
    • Ye, F.Q.1    Berman, K.F.2    Ellmore, T.3    Esposito, G.4    van Horn, J.D.5    Yang, Y.6
  • 27
    • 4644225113 scopus 로고    scopus 로고
    • Whole-brain 3D perfusion MRI at 3.0 T using CASL with a separate labeling coil
    • Talagala S.L., Ye F.Q., Ledden P.J., and Chesnick S. Whole-brain 3D perfusion MRI at 3.0 T using CASL with a separate labeling coil. Magn Reson Med 52 (2004) 131-140
    • (2004) Magn Reson Med , vol.52 , pp. 131-140
    • Talagala, S.L.1    Ye, F.Q.2    Ledden, P.J.3    Chesnick, S.4
  • 29
    • 0033033852 scopus 로고    scopus 로고
    • Multislice perfusion and perfusion territory imaging in humans with separate label and image coils
    • Zaharchuk G., Ledden P.J., Kwong K.K., Reese T.G., Rosen B.R., and Wald L.L. Multislice perfusion and perfusion territory imaging in humans with separate label and image coils. Magn Reson Med 41 6 (1999) 1093-1098
    • (1999) Magn Reson Med , vol.41 , Issue.6 , pp. 1093-1098
    • Zaharchuk, G.1    Ledden, P.J.2    Kwong, K.K.3    Reese, T.G.4    Rosen, B.R.5    Wald, L.L.6
  • 30
    • 0028854355 scopus 로고
    • Multi-slice MRI of rat brain perfusion during amphetamine stimulation using arterial spin labeling
    • Silva A.C., Zhang W., Williams D.S., and Koretsky A.P. Multi-slice MRI of rat brain perfusion during amphetamine stimulation using arterial spin labeling. Magn Reson Med 33 2 (1995) 209-214
    • (1995) Magn Reson Med , vol.33 , Issue.2 , pp. 209-214
    • Silva, A.C.1    Zhang, W.2    Williams, D.S.3    Koretsky, A.P.4
  • 31
    • 0002397475 scopus 로고
    • Blood volumes, hematocrits and transit-times in parenchymal microvascular systems of the rat brain
    • Le Bihan D.L. (Ed), Raven Press, New York
    • Nakagawa H., Lin S., Bereczki D., Gesztelyi G., Otsuka T., Wei L., et al. Blood volumes, hematocrits and transit-times in parenchymal microvascular systems of the rat brain. In: Le Bihan D.L. (Ed). Diffusion and perfusion magnetic resonance imaging (1995), Raven Press, New York 193-200
    • (1995) Diffusion and perfusion magnetic resonance imaging , pp. 193-200
    • Nakagawa, H.1    Lin, S.2    Bereczki, D.3    Gesztelyi, G.4    Otsuka, T.5    Wei, L.6
  • 32
    • 0032588958 scopus 로고    scopus 로고
    • T1 and magnetization transfer at 7 Tesla in acute ischemic infarct in the rat
    • Ewing J.R., Jiang Q., Boska M., Zhang Z.G., Brown S.L., Li G.H., et al. T1 and magnetization transfer at 7 Tesla in acute ischemic infarct in the rat. Magn Reson Med 41 4 (1999) 696-705
    • (1999) Magn Reson Med , vol.41 , Issue.4 , pp. 696-705
    • Ewing, J.R.1    Jiang, Q.2    Boska, M.3    Zhang, Z.G.4    Brown, S.L.5    Li, G.H.6
  • 33
    • 13544268552 scopus 로고    scopus 로고
    • Anatomical and functional MR imaging in the macaque monkey using a vertical large-bore 7 tesla setup
    • Pfeuffer J., Merkle H., Beyerlein M., Logothetis K.N., and Steudel T. Anatomical and functional MR imaging in the macaque monkey using a vertical large-bore 7 tesla setup. Magn Reson Imaging 22 10 (2004) 1343-1359
    • (2004) Magn Reson Imaging , vol.22 , Issue.10 , pp. 1343-1359
    • Pfeuffer, J.1    Merkle, H.2    Beyerlein, M.3    Logothetis, K.N.4    Steudel, T.5
  • 34
    • 0023430879 scopus 로고
    • Positron emission tomographic measurement of cerebral blood flow and permeability-surface area product of water using [15O]water and [11C]butanol
    • Herscovitch P., Raichle M.E., Kilbourn M.R., and Welch M.J. Positron emission tomographic measurement of cerebral blood flow and permeability-surface area product of water using [15O]water and [11C]butanol. J Cereb Blood Flow Metab 7 5 (1987) 527-542
    • (1987) J Cereb Blood Flow Metab , vol.7 , Issue.5 , pp. 527-542
    • Herscovitch, P.1    Raichle, M.E.2    Kilbourn, M.R.3    Welch, M.J.4
  • 36
    • 0036897033 scopus 로고    scopus 로고
    • Visual areas in macaque cortex measured using functional magnetic resonance imaging
    • Brewer A.A., Press W.A., Logothetis N.K., and Wandell B.A. Visual areas in macaque cortex measured using functional magnetic resonance imaging. J Neurosci 22 23 (2002) 10416-10426
    • (2002) J Neurosci , vol.22 , Issue.23 , pp. 10416-10426
    • Brewer, A.A.1    Press, W.A.2    Logothetis, N.K.3    Wandell, B.A.4
  • 38
    • 0036160977 scopus 로고    scopus 로고
    • Correction of physiologically induced global off-resonance effects in dynamic echo-planar and spiral functional imaging
    • Pfeuffer J., Van de Moortele P.F., Ugurbil K., Hu X., and Glover G.H. Correction of physiologically induced global off-resonance effects in dynamic echo-planar and spiral functional imaging. Magn Reson Med 47 2 (2002) 344-353
    • (2002) Magn Reson Med , vol.47 , Issue.2 , pp. 344-353
    • Pfeuffer, J.1    Van de Moortele, P.F.2    Ugurbil, K.3    Hu, X.4    Glover, G.H.5
  • 39
    • 0034127786 scopus 로고    scopus 로고
    • Image registration using a symmetric prior-in three dimensions
    • Ashburner J., Andersson J.L., and Friston K.J. Image registration using a symmetric prior-in three dimensions. Hum Brain Mapp 9 4 (2000) 212-225
    • (2000) Hum Brain Mapp , vol.9 , Issue.4 , pp. 212-225
    • Ashburner, J.1    Andersson, J.L.2    Friston, K.J.3
  • 40
    • 0036338610 scopus 로고    scopus 로고
    • Experimental design and the relative sensitivity of BOLD and perfusion fMRI
    • Aguirre G.K., Detre J.A., Zarahn E., and Alsop D.C. Experimental design and the relative sensitivity of BOLD and perfusion fMRI. Neuroimage 15 3 (2002) 488-500
    • (2002) Neuroimage , vol.15 , Issue.3 , pp. 488-500
    • Aguirre, G.K.1    Detre, J.A.2    Zarahn, E.3    Alsop, D.C.4
  • 41
    • 10044279428 scopus 로고    scopus 로고
    • A signal processing model for arterial spin labeling functional MRI
    • Liu T.T., and Wong E.C. A signal processing model for arterial spin labeling functional MRI. Neuroimage 24 1 (2005) 207-215
    • (2005) Neuroimage , vol.24 , Issue.1 , pp. 207-215
    • Liu, T.T.1    Wong, E.C.2
  • 42
    • 0036325034 scopus 로고    scopus 로고
    • Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 tesla
    • Wang J., Alsop D.C., Li L., Listerud J., Gonzalez-At J.B., Schnall M.D., et al. Comparison of quantitative perfusion imaging using arterial spin labeling at 1.5 and 4.0 tesla. Magn Reson Med 48 2 (2002) 242-254
    • (2002) Magn Reson Med , vol.48 , Issue.2 , pp. 242-254
    • Wang, J.1    Alsop, D.C.2    Li, L.3    Listerud, J.4    Gonzalez-At, J.B.5    Schnall, M.D.6
  • 44
    • 1842481964 scopus 로고    scopus 로고
    • Normal cerebral perfusion measurements using arterial spin labeling: reproducibility, stability, and age and gender effects
    • Parkes L.M., Rashid W., Chard D.T., and Tofts P.S. Normal cerebral perfusion measurements using arterial spin labeling: reproducibility, stability, and age and gender effects. Magn Reson Med 51 4 (2004) 736-743
    • (2004) Magn Reson Med , vol.51 , Issue.4 , pp. 736-743
    • Parkes, L.M.1    Rashid, W.2    Chard, D.T.3    Tofts, P.S.4
  • 45
    • 0344900036 scopus 로고    scopus 로고
    • Precision of the CASL-perfusion MRI technique for the measurement of cerebral blood flow in whole brain and vascular territories
    • Floyd T.F., Ratcliffe S.J., Wang J., Resch B., and Detre J.A. Precision of the CASL-perfusion MRI technique for the measurement of cerebral blood flow in whole brain and vascular territories. J Magn Reson Imaging 18 6 (2003) 649-655
    • (2003) J Magn Reson Imaging , vol.18 , Issue.6 , pp. 649-655
    • Floyd, T.F.1    Ratcliffe, S.J.2    Wang, J.3    Resch, B.4    Detre, J.A.5
  • 46
    • 0030974702 scopus 로고    scopus 로고
    • Characterization of cerebral blood oxygenation and flow changes during prolonged brain activation
    • Bandettini P.A., Kwong K.K., Davis T.L., Tootell R.B., Wong E.C., Fox P.T., et al. Characterization of cerebral blood oxygenation and flow changes during prolonged brain activation. Hum Brain Mapp 5 2 (1997) 93-109
    • (1997) Hum Brain Mapp , vol.5 , Issue.2 , pp. 93-109
    • Bandettini, P.A.1    Kwong, K.K.2    Davis, T.L.3    Tootell, R.B.4    Wong, E.C.5    Fox, P.T.6
  • 47
    • 0032904174 scopus 로고    scopus 로고
    • Perfusion-based functional magnetic resonance imaging with single-shot RARE and GRASE acquisitions
    • Crelier G.R., Hoge R.D., Munger P., and Pike G.B. Perfusion-based functional magnetic resonance imaging with single-shot RARE and GRASE acquisitions. Magn Reson Med 41 1 (1999) 132-136
    • (1999) Magn Reson Med , vol.41 , Issue.1 , pp. 132-136
    • Crelier, G.R.1    Hoge, R.D.2    Munger, P.3    Pike, G.B.4
  • 48
    • 0035016725 scopus 로고    scopus 로고
    • Changes in human regional cerebral blood flow and cerebral blood volume during visual stimulation measured by positron emission tomography
    • Ito H., Takahashi K., Hatazawa J., Kim S.G., and Kanno I. Changes in human regional cerebral blood flow and cerebral blood volume during visual stimulation measured by positron emission tomography. J Cereb Blood Flow Metab 21 5 (2001) 608-612
    • (2001) J Cereb Blood Flow Metab , vol.21 , Issue.5 , pp. 608-612
    • Ito, H.1    Takahashi, K.2    Hatazawa, J.3    Kim, S.G.4    Kanno, I.5
  • 49
    • 0033774123 scopus 로고    scopus 로고
    • Assessment of hemodynamic response during focal neural activity in human using bolus tracking, arterial spin labeling and BOLD techniques
    • Li T.Q., Haefelin T.N., Chan B., Kastrup A., Jonsson T., Glover G.H., et al. Assessment of hemodynamic response during focal neural activity in human using bolus tracking, arterial spin labeling and BOLD techniques. Neuroimage 12 4 (2000) 442-451
    • (2000) Neuroimage , vol.12 , Issue.4 , pp. 442-451
    • Li, T.Q.1    Haefelin, T.N.2    Chan, B.3    Kastrup, A.4    Jonsson, T.5    Glover, G.H.6
  • 50
    • 0021240859 scopus 로고
    • Stimulus rate dependence of regional cerebral blood flow in human striate cortex, demonstrated by positron emission tomography
    • Fox P.T., and Raichle M.E. Stimulus rate dependence of regional cerebral blood flow in human striate cortex, demonstrated by positron emission tomography. J Neurophysiol 51 5 (1984) 1109-1120
    • (1984) J Neurophysiol , vol.51 , Issue.5 , pp. 1109-1120
    • Fox, P.T.1    Raichle, M.E.2
  • 51
    • 16444370328 scopus 로고    scopus 로고
    • Input parameter sensitivity analysis and comparison of quantification models for continuous arterial spin labeling
    • Steger T.R., White R.A., and Jackson E.F. Input parameter sensitivity analysis and comparison of quantification models for continuous arterial spin labeling. Magn Reson Med 53 4 (2005) 895-903
    • (2005) Magn Reson Med , vol.53 , Issue.4 , pp. 895-903
    • Steger, T.R.1    White, R.A.2    Jackson, E.F.3
  • 53
    • 0031953755 scopus 로고    scopus 로고
    • Application of a beta microprobe for quantification of regional cerebral blood flow with (15)O-water and PET in rhesus monkeys
    • Seki C., Okada H., Mori S., Kakiuchi T., Yoshikawa E., Nishiyama S., et al. Application of a beta microprobe for quantification of regional cerebral blood flow with (15)O-water and PET in rhesus monkeys. Ann Nucl Med 12 1 (1998) 7-14
    • (1998) Ann Nucl Med , vol.12 , Issue.1 , pp. 7-14
    • Seki, C.1    Okada, H.2    Mori, S.3    Kakiuchi, T.4    Yoshikawa, E.5    Nishiyama, S.6
  • 54
    • 24944544834 scopus 로고    scopus 로고
    • Rapid quantitative measurement of CMRO(2) and CBF by dual administration of (15)O-labeled oxygen and water during a single PET scan - a validation study and error analysis in anesthetized monkeys
    • Kudomi N., Hayashi T., Teramoto N., Watabe H., Kawachi N., Ohta Y., et al. Rapid quantitative measurement of CMRO(2) and CBF by dual administration of (15)O-labeled oxygen and water during a single PET scan - a validation study and error analysis in anesthetized monkeys. J Cereb Blood Flow Metab 25 9 (2005) 1209-1224
    • (2005) J Cereb Blood Flow Metab , vol.25 , Issue.9 , pp. 1209-1224
    • Kudomi, N.1    Hayashi, T.2    Teramoto, N.3    Watabe, H.4    Kawachi, N.5    Ohta, Y.6
  • 55
    • 0014182632 scopus 로고
    • Measurement of total cerebral blood flow in the monkey by external monitoring of cesium-131
    • Weiner D.E. Measurement of total cerebral blood flow in the monkey by external monitoring of cesium-131. Circ Res 21 6 (1967) 805-816
    • (1967) Circ Res , vol.21 , Issue.6 , pp. 805-816
    • Weiner, D.E.1
  • 56
    • 33845256771 scopus 로고    scopus 로고
    • An account of the discrepancy between MRI and PET cerebral blood flow measures. A high-field MRI investigation
    • Donahue M.J., Lu H., Jones C.K., Pekar J.J., and van Zijl P.C. An account of the discrepancy between MRI and PET cerebral blood flow measures. A high-field MRI investigation. NMR Biomed 19 8 (2006) 1043-1054
    • (2006) NMR Biomed , vol.19 , Issue.8 , pp. 1043-1054
    • Donahue, M.J.1    Lu, H.2    Jones, C.K.3    Pekar, J.J.4    van Zijl, P.C.5
  • 57
    • 0033887897 scopus 로고    scopus 로고
    • Quantitation of regional cerebral blood flow corrected for partial volume effect using O-15 water and PET: I. Theory, error analysis, and stereologic comparison
    • Iida H., Law I., Pakkenberg B., Krarup-Hansen A., Eberl S., Holm S., et al. Quantitation of regional cerebral blood flow corrected for partial volume effect using O-15 water and PET: I. Theory, error analysis, and stereologic comparison. J Cereb Blood Flow Metab 20 8 (2000) 1237-1251
    • (2000) J Cereb Blood Flow Metab , vol.20 , Issue.8 , pp. 1237-1251
    • Iida, H.1    Law, I.2    Pakkenberg, B.3    Krarup-Hansen, A.4    Eberl, S.5    Holm, S.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.