메뉴 건너뛰기




Volumn 20, Issue 4, 2007, Pages 352-358

Offsite anesthesiology in the cardiac catheterization lab

Author keywords

Cardiac catheterization lab; Cardiac electrophysiology lab; Offsite anesthesia

Indexed keywords

ANESTHESIOLOGY; ANESTHESIST; CARDIAC RESYNCHRONIZATION THERAPY; CORONARY STENT; DEFIBRILLATOR; DRUG ELUTING STENT; ECHOCARDIOGRAPHY; FLUOROSCOPY; GENERAL ANESTHESIA; HEART ASSIST DEVICE; HEART ATRIUM SEPTUM DEFECT; HEART CATHETERIZATION; HEART VALVE REPLACEMENT; HUMAN; PATIENT CARE; PATIENT SAFETY; PERCUTANEOUS CORONARY INTERVENTION; PRACTICE GUIDELINE; PRIORITY JOURNAL; RADIATION EXPOSURE; REVIEW; SEDATION;

EID: 34447342848     PISSN: 09527907     EISSN: None     Source Type: Journal    
DOI: 10.1097/ACO.0b013e32827ab47b     Document Type: Review
Times cited : (28)

References (43)
  • 1
    • 0036204179 scopus 로고    scopus 로고
    • American Society of Anesthesiologists Task Force on Sedation and Analgesia by Non-Anesthesiologists. Practice guidelines for sedation and analgesia by non-anesthesiologists. Anesthesiology 2002; 96: 1004-1017
    • American Society of Anesthesiologists Task Force on Sedation and Analgesia by Non-Anesthesiologists. Practice guidelines for sedation and analgesia by non-anesthesiologists. Anesthesiology 2002; 96: 1004-1017.
  • 2
    • 32044431845 scopus 로고    scopus 로고
    • Coronary-artery stents
    • Excellent review of the history of coronary stenting, including current indications and future perspectives
    • Serruys PW, Kutryk MJ, Ong AT. Coronary-artery stents. N Engl J Med 2006; 354:483-495. Excellent review of the history of coronary stenting, including current indications and future perspectives.
    • (2006) N Engl J Med , vol.354 , pp. 483-495
    • Serruys, P.W.1    Kutryk, M.J.2    Ong, A.T.3
  • 3
    • 0027934377 scopus 로고
    • A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators
    • Fischman DL, Leon MB, Baim DS, et al. A randomized comparison of coronary-stent placement and balloon angioplasty in the treatment of coronary artery disease. Stent Restenosis Study Investigators. N Engl J Med 1994; 331:496-501.
    • (1994) N Engl J Med , vol.331 , pp. 496-501
    • Fischman, D.L.1    Leon, M.B.2    Baim, D.S.3
  • 4
    • 0028123099 scopus 로고
    • A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group
    • Serruys PW, de Jaegere P, Kiemeneij F, et al. A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group. N Engl J Med 1994; 331:489-495.
    • (1994) N Engl J Med , vol.331 , pp. 489-495
    • Serruys, P.W.1    de Jaegere, P.2    Kiemeneij, F.3
  • 5
    • 33847723010 scopus 로고    scopus 로고
    • Unanswered questions - drug-eluting stents and the risk of late thrombosis
    • This is an informative editorial regarding the controversy of late thrombosis in drugeluting stents
    • Maisel WH. Unanswered questions - drug-eluting stents and the risk of late thrombosis. N Engl J Med 2007; 356:981-984. This is an informative editorial regarding the controversy of late thrombosis in drugeluting stents.
    • (2007) N Engl J Med , vol.356 , pp. 981-984
    • Maisel, W.H.1
  • 6
    • 0141765805 scopus 로고    scopus 로고
    • Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery
    • Moses JW, Leon MB, Popma JJ, et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003; 349:1315-1323.
    • (2003) N Engl J Med , vol.349 , pp. 1315-1323
    • Moses, J.W.1    Leon, M.B.2    Popma, J.J.3
  • 7
    • 0037422604 scopus 로고    scopus 로고
    • TAXUS I: Six- and twelve-month results from a randomized, double-blind trial on a slow-release paclitaxel-eluting stent for de novo coronary lesions
    • Grube E, Silber S, Hauptmann KE, et al. TAXUS I: six- and twelve-month results from a randomized, double-blind trial on a slow-release paclitaxel-eluting stent for de novo coronary lesions. Circulation 2003; 107:38-42.
    • (2003) Circulation , vol.107 , pp. 38-42
    • Grube, E.1    Silber, S.2    Hauptmann, K.E.3
  • 8
    • 33646177081 scopus 로고    scopus 로고
    • On- versus off-label use of drug-eluting coronary stents in clinical practice (report from the American College of Cardiology National Cardiovascular Data Registry [NCDR])
    • Rao SV, Shaw RE, Brindis RG, et al. On- versus off-label use of drug-eluting coronary stents in clinical practice (report from the American College of Cardiology National Cardiovascular Data Registry [NCDR]). Am J Cardiol 2006; 97:1478-1481.
    • (2006) Am J Cardiol , vol.97 , pp. 1478-1481
    • Rao, S.V.1    Shaw, R.E.2    Brindis, R.G.3
  • 9
    • 32644434600 scopus 로고    scopus 로고
    • Comparison of coronary artery bypass surgery with percutaneous coronary intervention with drug-eluting stents for unprotected left main coronary artery disease
    • Lee MS, Kapoor N, Jamal F, et al. Comparison of coronary artery bypass surgery with percutaneous coronary intervention with drug-eluting stents for unprotected left main coronary artery disease. J Am Coll Cardiol 2006; 47:864-870.
    • (2006) J Am Coll Cardiol , vol.47 , pp. 864-870
    • Lee, M.S.1    Kapoor, N.2    Jamal, F.3
  • 10
    • 33751585973 scopus 로고    scopus 로고
    • Trends in percutaneous versus surgical revascularization of unprotected left main coronary stenosis in the drug-eluting stent era: A report from the American College of Cardiology-National Cardiovascular Data Registry (ACC-NCDR)
    • Huang HW, Brent BN, Shaw RE. Trends in percutaneous versus surgical revascularization of unprotected left main coronary stenosis in the drug-eluting stent era: a report from the American College of Cardiology-National Cardiovascular Data Registry (ACC-NCDR). Catheter Cardiovasc Interv 2006; 68:867-872.
    • (2006) Catheter Cardiovasc Interv , vol.68 , pp. 867-872
    • Huang, H.W.1    Brent, B.N.2    Shaw, R.E.3
  • 11
    • 33847707734 scopus 로고    scopus 로고
    • Stent thrombosis redux-the FDA perspective
    • This is another informative editorial in the same issue of the New England Journal of Medicine regarding stent thrombosis
    • Farb A, Boam AB. Stent thrombosis redux-the FDA perspective. N Engl JMed 2007; 356:984-987. This is another informative editorial in the same issue of the New England Journal of Medicine regarding stent thrombosis.
    • (2007) N Engl JMed , vol.356 , pp. 984-987
    • Farb, A.1    Boam, A.B.2
  • 12
    • 33645082957 scopus 로고    scopus 로고
    • Henriques JP, Remmelink M, Baan J Jr, et al. Safety and feasibility of elective high-risk percutaneous coronary intervention procedures with left ventricular support of the Impella Recover LP 2.5. Am J Cardiol 2006; 97:990-992. This is a good overview of the Impella LP 2.5 device including procedural implications of placement and complications to be anticipated.
    • Henriques JP, Remmelink M, Baan J Jr, et al. Safety and feasibility of elective high-risk percutaneous coronary intervention procedures with left ventricular support of the Impella Recover LP 2.5. Am J Cardiol 2006; 97:990-992. This is a good overview of the Impella LP 2.5 device including procedural implications of placement and complications to be anticipated.
  • 14
    • 33845633335 scopus 로고    scopus 로고
    • Placement of the TandemHeart percutaneous left ventricular assist device
    • Pretorius M, Hughes AK, Stahlman MB, et al. Placement of the TandemHeart percutaneous left ventricular assist device. Anesth Analg 2006; 103:1412-1413.
    • (2006) Anesth Analg , vol.103 , pp. 1412-1413
    • Pretorius, M.1    Hughes, A.K.2    Stahlman, M.B.3
  • 15
    • 33845606794 scopus 로고    scopus 로고
    • Percutaneous endocardial and epicardial ablation of hypotensive ventricular tachycardia with percutaneous left ventricular assist in the electrophysiology laboratory
    • Friedman PA, Munger TM, Torres N, Rihal C. Percutaneous endocardial and epicardial ablation of hypotensive ventricular tachycardia with percutaneous left ventricular assist in the electrophysiology laboratory. J Cardiovasc Electrophysiol 2007; 18:106-109.
    • (2007) J Cardiovasc Electrophysiol , vol.18 , pp. 106-109
    • Friedman, P.A.1    Munger, T.M.2    Torres, N.3    Rihal, C.4
  • 16
    • 0017300623 scopus 로고
    • Secundum atrial septal defect. Nonoperative closure during cardiac catheterization
    • King TD, Thompson SL, Steiner C, Mills NL. Secundum atrial septal defect. Nonoperative closure during cardiac catheterization. Jama 1976; 235:2506-2509.
    • (1976) Jama , vol.235 , pp. 2506-2509
    • King, T.D.1    Thompson, S.L.2    Steiner, C.3    Mills, N.L.4
  • 17
    • 33746192637 scopus 로고    scopus 로고
    • Device closure rates of simple atrial septal defects optimized by the STARFlex device
    • Nugent AW, Britt A, Gauvreau K, et al. Device closure rates of simple atrial septal defects optimized by the STARFlex device. J Am Coll Cardiol 2006; 48:538-544.
    • (2006) J Am Coll Cardiol , vol.48 , pp. 538-544
    • Nugent, A.W.1    Britt, A.2    Gauvreau, K.3
  • 18
    • 0037183552 scopus 로고    scopus 로고
    • Percutaneous transcatheter closure of patent foramen ovale in patients with paradoxical embolism
    • Martin F, Sanchez PL, Doherty E, et al. Percutaneous transcatheter closure of patent foramen ovale in patients with paradoxical embolism. Circulation 2002; 106:1121-1126.
    • (2002) Circulation , vol.106 , pp. 1121-1126
    • Martin, F.1    Sanchez, P.L.2    Doherty, E.3
  • 19
    • 13544253485 scopus 로고    scopus 로고
    • Long-term outcome of transcatheter secundum-type atrial septal defect closure using Amplatzer septal occluders
    • Masura J, Gavora P, Podnar T. Long-term outcome of transcatheter secundum-type atrial septal defect closure using Amplatzer septal occluders. J Am Coll Cardiol 2005; 45:505-507.
    • (2005) J Am Coll Cardiol , vol.45 , pp. 505-507
    • Masura, J.1    Gavora, P.2    Podnar, T.3
  • 20
    • 33750532961 scopus 로고    scopus 로고
    • BioSTAR Evaluation STudy (BEST): A prospective, multicenter, phase I clinical trial to evaluate the feasibility, efficacy, and safety of the BioSTAR bioabsorbable septal repair implant for the closure of atrial-level shunts
    • Mullen MJ, Hildick-Smith D, De Giovanni JV, et al. BioSTAR Evaluation STudy (BEST): a prospective, multicenter, phase I clinical trial to evaluate the feasibility, efficacy, and safety of the BioSTAR bioabsorbable septal repair implant for the closure of atrial-level shunts. Circulation 2006; 114:1962-1967.
    • (2006) Circulation , vol.114 , pp. 1962-1967
    • Mullen, M.J.1    Hildick-Smith, D.2    De Giovanni, J.V.3
  • 21
    • 33748995373 scopus 로고    scopus 로고
    • Percutaneous closure of postmyocardial infarction ventricular septal defect
    • Garay F, Cao QL, Hijazi ZM. Percutaneous closure of postmyocardial infarction ventricular septal defect. J Interv Cardiol 2006; 19:S67-72.
    • (2006) J Interv Cardiol , vol.19
    • Garay, F.1    Cao, Q.L.2    Hijazi, Z.M.3
  • 22
    • 21044456170 scopus 로고    scopus 로고
    • The clinical development of percutaneous heart valve technology: A position statement of the Society of Thoracic Surgeons (STS), the American Association for Thoracic Surgery (AATS), and the Society for Cardiovascular Angiography and Interventions (SCAI) Endorsed by the American College of Cardiology Foundation (ACCF) and the American Heart Association (AHA)
    • Vassiliades TA Jr, Block PC, Cohn LH, et al. The clinical development of percutaneous heart valve technology: a position statement of the Society of Thoracic Surgeons (STS), the American Association for Thoracic Surgery (AATS), and the Society for Cardiovascular Angiography and Interventions (SCAI) Endorsed by the American College of Cardiology Foundation (ACCF) and the American Heart Association (AHA). J Am Coll Cardiol 2005; 45:1554-1560.
    • (2005) J Am Coll Cardiol , vol.45 , pp. 1554-1560
    • Vassiliades Jr, T.A.1    Block, P.C.2    Cohn, L.H.3
  • 23
    • 0037058854 scopus 로고    scopus 로고
    • Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: First human case description
    • Cribier A, Eltchaninoff H, Bash A, et al. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation 2002; 106:3006-3008.
    • (2002) Circulation , vol.106 , pp. 3006-3008
    • Cribier, A.1    Eltchaninoff, H.2    Bash, A.3
  • 24
    • 33748987365 scopus 로고    scopus 로고
    • Percutaneous implantation of aortic valve prosthesis in patients with calcific aortic stenosis: Technical advances, clinical results and future strategies
    • Cribier A, Eltchaninoff H, Tron C, et al. Percutaneous implantation of aortic valve prosthesis in patients with calcific aortic stenosis: technical advances, clinical results and future strategies. J Interv Cardiol 2006; 19:S87-S96.
    • (2006) J Interv Cardiol , vol.19
    • Cribier, A.1    Eltchaninoff, H.2    Tron, C.3
  • 25
    • 33750862415 scopus 로고    scopus 로고
    • Percutaneous transcatheter repair for mitral regurgitation
    • This is an excellent review of current percutaneous approaches to mitral regurgitation
    • Block PC. Percutaneous transcatheter repair for mitral regurgitation. J Interv Cardiol 2006; 19:547-551. This is an excellent review of current percutaneous approaches to mitral regurgitation.
    • (2006) J Interv Cardiol , vol.19 , pp. 547-551
    • Block, P.C.1
  • 26
    • 33644863185 scopus 로고    scopus 로고
    • Future of transcatheter repair of the mitral valve
    • Alfieri O, Maisano F, Colombo A. Future of transcatheter repair of the mitral valve. Am J Cardiol 2005; 96:71L-75L.
    • (2005) Am J Cardiol , vol.96
    • Alfieri, O.1    Maisano, F.2    Colombo, A.3
  • 27
    • 28244463519 scopus 로고    scopus 로고
    • Percutaneous mitral valve repair using the edge-to-edge technique: Six-month results of the EVEREST Phase I Clinical Trial
    • Feldman T, Wasserman HS, Herrmann HC, et al. Percutaneous mitral valve repair using the edge-to-edge technique: six-month results of the EVEREST Phase I Clinical Trial. J Am Coll Cardiol 2005; 46:2134-2140.
    • (2005) J Am Coll Cardiol , vol.46 , pp. 2134-2140
    • Feldman, T.1    Wasserman, H.S.2    Herrmann, H.C.3
  • 28
    • 33644852948 scopus 로고    scopus 로고
    • Percutaneous transvenous mitral annuloplasty: Initial human experience with device implantation in the coronary sinus
    • Webb JG, Harnek J, Munt BI, et al. Percutaneous transvenous mitral annuloplasty: initial human experience with device implantation in the coronary sinus. Circulation 2006; 113:851-855.
    • (2006) Circulation , vol.113 , pp. 851-855
    • Webb, J.G.1    Harnek, J.2    Munt, B.I.3
  • 29
    • 33749017334 scopus 로고    scopus 로고
    • Percutaneous closure of paravalvular leaks
    • A review of percutaneous closure techniques for paravalvular leaks
    • Hein R, Lang K, Wunderlich N, et al. Percutaneous closure of paravalvular leaks. J Interv Cardiol 2006; 19:S73-S77. A review of percutaneous closure techniques for paravalvular leaks.
    • (2006) J Interv Cardiol , vol.19
    • Hein, R.1    Lang, K.2    Wunderlich, N.3
  • 30
    • 33749603907 scopus 로고    scopus 로고
    • Percutaneous closure of prosthetic paravalvular leaks: Case series and review
    • Pate GE, Al Zubaidi A, Chandavimol M, et al. Percutaneous closure of prosthetic paravalvular leaks: case series and review. Catheter Cardiovasc Interv 2006; 68:528-533.
    • (2006) Catheter Cardiovasc Interv , vol.68 , pp. 528-533
    • Pate, G.E.1    Al Zubaidi, A.2    Chandavimol, M.3
  • 31
    • 33644919118 scopus 로고    scopus 로고
    • The year in clinical electrophysiology
    • This is a good yearly publication that reviews the recent advances in clinical electrophysiology
    • Scheinman MM, Keung E. The year in clinical electrophysiology. J Am Coll Cardiol 2006; 47:1207-1213. This is a good yearly publication that reviews the recent advances in clinical electrophysiology.
    • (2006) J Am Coll Cardiol , vol.47 , pp. 1207-1213
    • Scheinman, M.M.1    Keung, E.2
  • 32
    • 31144470452 scopus 로고    scopus 로고
    • Catheter and surgical ablation of atrial fibrillation
    • Earley MJ, Schilling RJ. Catheter and surgical ablation of atrial fibrillation. Heart 2006; 92:266-274.
    • (2006) Heart , vol.92 , pp. 266-274
    • Earley, M.J.1    Schilling, R.J.2
  • 33
    • 0037149716 scopus 로고    scopus 로고
    • Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction
    • Moss AJ, Zareba W, Hall WJ, et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med 2002; 346:877-883.
    • (2002) N Engl J Med , vol.346 , pp. 877-883
    • Moss, A.J.1    Zareba, W.2    Hall, W.J.3
  • 34
    • 0037109150 scopus 로고    scopus 로고
    • ACC/AHA/NASPE 2002 guideline update for implantation of cardiac pacemakers and antiarrhythmia devices: Summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines)
    • Gregoratos G, Abrams J, Epstein AE, et al. ACC/AHA/NASPE 2002 guideline update for implantation of cardiac pacemakers and antiarrhythmia devices: summary article: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee to Update the 1998 Pacemaker Guidelines). Circulation 2002; 106:2145-2161.
    • (2002) Circulation , vol.106 , pp. 2145-2161
    • Gregoratos, G.1    Abrams, J.2    Epstein, A.E.3
  • 35
    • 0006918490 scopus 로고    scopus 로고
    • Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators
    • Moss AJ, Hall WJ, Cannom DS, et al. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators. N Engl J Med 1996; 335:1933-1940.
    • (1996) N Engl J Med , vol.335 , pp. 1933-1940
    • Moss, A.J.1    Hall, W.J.2    Cannom, D.S.3
  • 36
    • 2442572117 scopus 로고    scopus 로고
    • Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy
    • Kadish A, Dyer A, Daubert JP, et al. Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy. N Engl J Med 2004; 350:2151-2158.
    • (2004) N Engl J Med , vol.350 , pp. 2151-2158
    • Kadish, A.1    Dyer, A.2    Daubert, J.P.3
  • 37
    • 19944429413 scopus 로고    scopus 로고
    • Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure
    • Bardy GH, Lee KL, Mark DB, et al. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med 2005; 352:225-237.
    • (2005) N Engl J Med , vol.352 , pp. 225-237
    • Bardy, G.H.1    Lee, K.L.2    Mark, D.B.3
  • 38
    • 0036257058 scopus 로고    scopus 로고
    • Cardiovascular responses to repetitive defibrillation during implantable cardioverter-defibrillator testing
    • Gilbert TB, Gold MR, Shorofsky SR, et al. Cardiovascular responses to repetitive defibrillation during implantable cardioverter-defibrillator testing. J Cardiothorac Vasc Anesth 2002; 16:180-185.
    • (2002) J Cardiothorac Vasc Anesth , vol.16 , pp. 180-185
    • Gilbert, T.B.1    Gold, M.R.2    Shorofsky, S.R.3
  • 39
    • 0029968908 scopus 로고    scopus 로고
    • Cardiac output is not affected during intraoperative testing of the automatic implantable cardioverter defibrillator
    • Meyer J, Mollhoff T, Seifert T, et al. Cardiac output is not affected during intraoperative testing of the automatic implantable cardioverter defibrillator. J Cardiovasc Electrophysiol 1996; 7:211-216.
    • (1996) J Cardiovasc Electrophysiol , vol.7 , pp. 211-216
    • Meyer, J.1    Mollhoff, T.2    Seifert, T.3
  • 40
    • 2542474634 scopus 로고    scopus 로고
    • Pacemaker and defibrillator lead extraction
    • Kutalek SP. Pacemaker and defibrillator lead extraction. Curr Opin Cardiol 2004; 19:19-22.
    • (2004) Curr Opin Cardiol , vol.19 , pp. 19-22
    • Kutalek, S.P.1
  • 41
    • 0036854491 scopus 로고    scopus 로고
    • Transesophageal echocardiographic evaluation of tricuspid valve regurgitation during pacemaker and implantable cardioverter defibrillator lead extraction
    • Roeffel S, Bracke F, Meijer A, et al. Transesophageal echocardiographic evaluation of tricuspid valve regurgitation during pacemaker and implantable cardioverter defibrillator lead extraction. Pacing Clin Electrophysiol 2002; 25:1583-1586.
    • (2002) Pacing Clin Electrophysiol , vol.25 , pp. 1583-1586
    • Roeffel, S.1    Bracke, F.2    Meijer, A.3
  • 42
    • 0035876392 scopus 로고    scopus 로고
    • American College of Cardiology/Society for Cardiac Angiography and Interventions Clinical Expert Consensus Document on cardiac catheterization laboratory standards. A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents
    • Bashore TM, Bates ER, Berger PB, et al. American College of Cardiology/Society for Cardiac Angiography and Interventions Clinical Expert Consensus Document on cardiac catheterization laboratory standards. A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents. J Am Coll Cardiol 2001; 37:2170-2214.
    • (2001) J Am Coll Cardiol , vol.37 , pp. 2170-2214
    • Bashore, T.M.1    Bates, E.R.2    Berger, P.B.3
  • 43
    • 28344448203 scopus 로고    scopus 로고
    • Radiation exposure to anesthesia personnel: The impact of an electrophysiology laboratory
    • Katz JD. Radiation exposure to anesthesia personnel: the impact of an electrophysiology laboratory. Anesth Analg 2005; 101:1725-1726.
    • (2005) Anesth Analg , vol.101 , pp. 1725-1726
    • Katz, J.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.