메뉴 건너뛰기




Volumn 34, Issue 6, 2007, Pages 2220-2227

Characterization of a fiber-optic-coupled radioluminescent detector for application in the mammography energy range

Author keywords

[No Author keywords available]

Indexed keywords

BINARY ALLOYS; DATA ACQUISITION; FIBER OPTICS; MAMMOGRAPHY; MOLYBDENUM ALLOYS; OPTICAL FIBERS; RHODIUM ALLOYS;

EID: 34447338367     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.2736788     Document Type: Article
Times cited : (40)

References (14)
  • 1
    • 2642588045 scopus 로고    scopus 로고
    • Towards in vivo TLD dosimetry in mammography
    • H. M. Warren-Forward and L. Duggan, " Towards in vivo TLD dosimetry in mammography., " Br. J. Radiol. 77, 426-432 (2004).
    • (2004) Br. J. Radiol. , vol.77 , pp. 426-432
    • Warren-Forward, H.M.1    Duggan, L.2
  • 2
    • 0035073371 scopus 로고    scopus 로고
    • OPERATIONAL TOPICS-Comparison of angular free-in-air and tissue-equivalent phantom response measurements in p-MOSFET dosimeters
    • B. D. Pomije, C. H. Huh, M. A. Tressler, D. E. Hintenlang, and W. E. Bolch, " OPERATIONAL TOPICS-Comparison of angular free-in-air and tissue-equivalent phantom response measurements in p-MOSFET dosimeters., " Health Phys. 80, 497-505 (2001).
    • (2001) Health Phys. , vol.80 , pp. 497-505
    • Pomije, B.D.1    Huh, C.H.2    Tressler, M.A.3    Hintenlang, D.E.4    Bolch, W.E.5
  • 3
    • 0031868395 scopus 로고    scopus 로고
    • The characterization of a commercial MOSFET dosimeter system for use in diagnostic X-ray
    • M. W. Bower and D. E. Hintenlang, " The characterization of a commercial MOSFET dosimeter system for use in diagnostic X-ray., " Health Phys. 75, 197-204 (1998).
    • (1998) Health Phys. , vol.75 , pp. 197-204
    • Bower, M.W.1    Hintenlang, D.E.2
  • 4
    • 0036888310 scopus 로고    scopus 로고
    • Estimation of mean-glandular dose from monitoring breast entrance skin air kerma using a high sensitivity metal oxide semiconductor field effect transistor (MOSFET) dosimeter system in mammography
    • S. L. Dong, T. C. Chu, J. S. Lee, G. Y. Lan, T. H. Wu, Y. H. Yeh, and J. J. Hwang, " Estimation of mean-glandular dose from monitoring breast entrance skin air kerma using a high sensitivity metal oxide semiconductor field effect transistor (MOSFET) dosimeter system in mammography., " Applied Radiation and Isotopes 57, 791-799 (2002).
    • (2002) Applied Radiation and Isotopes , vol.57 , pp. 791-799
    • Dong, S.L.1    Chu, T.C.2    Lee, J.S.3    Lan, G.Y.4    Wu, T.H.5    Yeh, Y.H.6    Hwang, J.J.7
  • 5
    • 34447320275 scopus 로고    scopus 로고
    • Results of an optical fiber based dosimetry system for use in computed tomography characterization
    • D. Klein, D. Peakheart, R. Gaza, X. Rong, and W. McKeever, " Results of an optical fiber based dosimetry system for use in computed tomography characterization., " Med. Phys. 33, 1998 (2006).
    • (2006) Med. Phys. , vol.33 , pp. 1998
    • Klein, D.1    Peakheart, D.2    Gaza, R.3    Rong, X.4    McKeever, W.5
  • 6
    • 2542466969 scopus 로고    scopus 로고
    • Real-time optical-fibre luminescence dosimetry for radiotherapy: Physical characteristics and applications in photon beams
    • M. C. Aznar, C. E. Andersen, L. Botter-Jensen, S. A. Back, S. Mattsson, F. Kjaer-Kristoffersen, and J. Medin, " Real-time optical-fibre luminescence dosimetry for radiotherapy: Physical characteristics and applications in photon beams., " Phys. Med. Biol. 49, 1655-1669 (2004).
    • (2004) Phys. Med. Biol. , vol.49 , pp. 1655-1669
    • Aznar, M.C.1    Andersen, C.E.2    Botter-Jensen, L.3    Back, S.A.4    Mattsson, S.5    Kjaer-Kristoffersen, F.6    Medin, J.7
  • 9
    • 34447338126 scopus 로고    scopus 로고
    • Radiation characteristics of a gated fiber-optic-coupled detector
    • C. Reft, " Radiation characteristics of a gated fiber-optic-coupled detector., " Med. Phys. 33, 2194-2195 (2006).
    • (2006) Med. Phys. , vol.33 , pp. 2194-2195
    • Reft, C.1
  • 10
    • 1842534250 scopus 로고    scopus 로고
    • Gated fiber-optic-coupled detector for in vivo real-time radiation dosimetry
    • B. L. Justus, P. Falkenstein, A. L. Huston, M. C. Plazas, H. Ning, and R. W. Miller, " Gated fiber-optic-coupled detector for in vivo real-time radiation dosimetry., " Appl. Opt. 43, 1663-1668 (2004).
    • (2004) Appl. Opt. , vol.43 , pp. 1663-1668
    • Justus, B.L.1    Falkenstein, P.2    Huston, A.L.3    Plazas, M.C.4    Ning, H.5    Miller, R.W.6
  • 12
    • 31844434014 scopus 로고    scopus 로고
    • Characterization of metal oxide semiconductor field effect transistor dosimeters for application in clinical mammography
    • L. A. Benevides and D. E. Hintenlang, " Characterization of metal oxide semiconductor field effect transistor dosimeters for application in clinical mammography., " Med. Phys. 33, 514-520 (2006).
    • (2006) Med. Phys. , vol.33 , pp. 514-520
    • Benevides, L.A.1    Hintenlang, D.E.2
  • 13
    • 85024990348 scopus 로고    scopus 로고
    • A tissue-equivalent phantom series for mammography dosimetry
    • W. P. Argo, K. Hintenlang, and D. E. Hintenlang, " A tissue-equivalent phantom series for mammography dosimetry., " J. Appl. Clin. Med. Phys. 5, 112-119 (2004).
    • (2004) J. Appl. Clin. Med. Phys. , vol.5 , pp. 112-119
    • Argo, W.P.1    Hintenlang, K.2    Hintenlang, D.E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.