-
1
-
-
0023121862
-
Multichannel intrachochlear electrodes: Mechanism of insertion trauma
-
Kennedy DW. Multichannel intrachochlear electrodes: mechanism of insertion trauma. Laryngoscope 1987; 97: 42-9.
-
(1987)
Laryngoscope
, vol.97
, pp. 42-49
-
-
Kennedy, D.W.1
-
3
-
-
0028961694
-
Cochlear pathology following reimplantation of multichannel scala tympani electrode array in the macaque
-
Shepherd RK, Clark GM, Xu S, Pyman BC. Cochlear pathology following reimplantation of multichannel scala tympani electrode array in the macaque. Am J Otol 1995; 16: 186-99.
-
(1995)
Am J Otol
, vol.16
, pp. 186-199
-
-
Shepherd, R.K.1
Clark, G.M.2
Xu, S.3
Pyman, B.C.4
-
4
-
-
0028267135
-
Otopathology in a case of multichannel cochlear implantation
-
Nadol JB, Ketten DR, Burgess BJ. Otopathology in a case of multichannel cochlear implantation. Laryngoscope 1994; 104: 299-303.
-
(1994)
Laryngoscope
, vol.104
, pp. 299-303
-
-
Nadol, J.B.1
Ketten, D.R.2
Burgess, B.J.3
-
5
-
-
0025719371
-
Evaluation of the temporal bones of a multichannel cochlear implant patient
-
Zappia JJ, Niparko JK, Oviatt DL, Kemink JL, Altschuler RA. Evaluation of the temporal bones of a multichannel cochlear implant patient. Ann Otol Rhinol Laryngol 1991; 100: 914-21.
-
(1991)
Ann Otol Rhinol Laryngol
, vol.100
, pp. 914-921
-
-
Zappia, J.J.1
Niparko, J.K.2
Oviatt, D.L.3
Kemink, J.L.4
Altschuler, R.A.5
-
7
-
-
0026002712
-
Cochlear implants: Histopathologic findings related to performance in 16 human temporal bones
-
Fayad J, Linthicum FH, Otto SR, Galey FR, House WF. Cochlear implants: histopathologic findings related to performance in 16 human temporal bones. Ann Otol Rhinol Laryngol 1991; 100: 807-11.
-
(1991)
Ann Otol Rhinol Laryngol
, vol.100
, pp. 807-811
-
-
Fayad, J.1
Linthicum, F.H.2
Otto, S.R.3
Galey, F.R.4
House, W.F.5
-
8
-
-
0026481346
-
Temporal bone histopathology of a patient with a Nucleus 22-channel cochlear implant
-
Marsh MA, Coker NJ, Jenkins HA. Temporal bone histopathology of a patient with a Nucleus 22-channel cochlear implant. Am J Otol 1992; 13 (3): 241-8.
-
(1992)
Am J Otol
, vol.13
, Issue.3
, pp. 241-248
-
-
Marsh, M.A.1
Coker, N.J.2
Jenkins, H.A.3
-
9
-
-
0030980713
-
Cochlear implant deep electrode insertion: Extent of insertional trauma
-
Stockh
-
Gstoettner W, Plenk H, Franz P, et al. Cochlear implant deep electrode insertion: extent of insertional trauma. Acta Otolaryngol (Stockh) 1997; 117: 274-7.
-
(1997)
Acta Otolaryngol
, vol.117
, pp. 274-277
-
-
Gstoettner, W.1
Plenk, H.2
Franz, P.3
-
13
-
-
0031305160
-
Postoperative radiographic assessment of the Combi 40 cochlear implant
-
Cerny C, Steiner E, Gstoettner W, Baumgartner W, Imhof H. Postoperative radiographic assessment of the Combi 40 cochlear implant. Am J Roentgenol 1997; 169: 1689-94.
-
(1997)
Am J Roentgenol
, vol.169
, pp. 1689-1694
-
-
Cerny, C.1
Steiner, E.2
Gstoettner, W.3
Baumgartner, W.4
Imhof, H.5
-
14
-
-
0002291192
-
The microscopic evaluation of hard tissue implants
-
Williams DF, ed. Boca Raton, FL: CRC Press
-
Plenk H. The microscopic evaluation of hard tissue implants. In: Williams DF, ed. Techniques of biocompatibility testing. Vol. 1. Boca Raton, FL: CRC Press, 1986: 35-81.
-
(1986)
Techniques of Biocompatibility Testing
, vol.1
, pp. 35-81
-
-
Plenk, H.1
|