메뉴 건너뛰기




Volumn 122, Issue 1-4, 2006, Pages 396-400

Two miniaturised TEPCS in a single detector for BNCT microdosimetry

Author keywords

[No Author keywords available]

Indexed keywords

ARTICLE; CALIBRATION; CONTROLLED STUDY; EQUIPMENT DESIGN; MICRODOSIMETRY; NEUTRON CAPTURE THERAPY; NEUTRON DOSIMETRY; PROPORTIONAL COUNTER; RADIATION FIELD; SIGNAL PROCESSING; COMPUTER AIDED DESIGN; COMPUTER ASSISTED RADIOTHERAPY; ELECTRONICS; EQUIPMENT; EVALUATION; INSTRUMENTATION; METHODOLOGY; NEUTRON; RADIOMETRY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; SYSTEM ANALYSIS; TRANSDUCER;

EID: 34347403694     PISSN: 01448420     EISSN: None     Source Type: Journal    
DOI: 10.1093/rpd/ncl484     Document Type: Article
Times cited : (15)

References (15)
  • 2
    • 0028938179 scopus 로고
    • Determination of dose components in phantoms irradiated with an epithermal neutron beam for boron neutrob capture therapy
    • Raaijmakers, C. P. J., Konijnenberg, M. W., Verhagen H. W. and Mijnheer, B. J. Determination of dose components in phantoms irradiated with an epithermal neutron beam for boron neutrob capture therapy. Med. Phys. 22, 321-329 (1995).
    • (1995) Med. Phys , vol.22 , pp. 321-329
    • Raaijmakers, C.P.J.1    Konijnenberg, M.W.2    Verhagen, H.W.3    Mijnheer, B.J.4
  • 4
    • 0034122435 scopus 로고    scopus 로고
    • Use of low pressure tissue equivalent proportional counters for dosimetry in BNCT and BNCEFNT
    • Kota, C. and Maughan, R. L. Use of low pressure tissue equivalent proportional counters for dosimetry in BNCT and BNCEFNT. Med. Phys. 27, 535-548 (2000).
    • (2000) Med. Phys , vol.27 , pp. 535-548
    • Kota, C.1    Maughan, R.L.2
  • 7
    • 0034806317 scopus 로고    scopus 로고
    • Miniature tissue-equivalent proportional counters for BNCT and BNCEFNT
    • Burmeister, J., Kota, C. and Maughan, R. L. Miniature tissue-equivalent proportional counters for BNCT and BNCEFNT. Med. Phys. 28, 1911-1925 (2001).
    • (2001) Med. Phys , vol.28 , pp. 1911-1925
    • Burmeister, J.1    Kota, C.2    Maughan, R.L.3
  • 8
    • 0029585797 scopus 로고
    • Practical considerations in the design and construction of tissue-equivalent proportional counters
    • Braby, L. A. Johnson, G. W. and Barthe, J. Practical considerations in the design and construction of tissue-equivalent proportional counters. Radiat. Prot. Dosim. 61, 351-379 (1995).
    • (1995) Radiat. Prot. Dosim , vol.61 , pp. 351-379
    • Braby, L.A.1    Johnson, G.W.2    Barthe, J.3
  • 12
    • 0017903733 scopus 로고
    • Microdosimetric measurements of ionisation by monoenergetic photons
    • Kliauga, P. and Dvorak, R. Microdosimetric measurements of ionisation by monoenergetic photons. Rad. Res. 73, 1-20 (1978).
    • (1978) Rad. Res , vol.73 , pp. 1-20
    • Kliauga, P.1    Dvorak, R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.